Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr 3 Single‐Crystal Semiconductor Detector

Abstract Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr 3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 10 10 photons s −1 mm −2 is reported. High‐quality solution‐grown CsPbBr 3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr 3 /Au. A high reverse‐bias voltage of 1000 V (435 V mm − 1 ) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm − 2 ), which enables a high sensitivity larger than 10 000 µC Gy air −1 cm − 2 and a simultaneous low detection limit of 22 nGy air s − 1 . The CsPbBr 3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 10 6 to 10 10 photons s − 1 mm − 2 . Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr 3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr 3 .

Pan, Lei↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation characterization summary of the NETL beam port 1/5 free-field environment at the 128-inch core centerline adjacent location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields in the University of Texas at Austin Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor for the beam port (BP) 1/5 free-field environment at the 128-inch location adjacent to the core centerline has been accomplished. NETL is being explored as an auxiliary neutron test facility for the Sandia National Laboratories radiation effects sciences research and development campaigns. The NETL reactor is a TRIGA Mark-II pulse and steady-state, above-ground pool-type reactor. NETL is intended as a university research reactor typically used to perform irradiation experiments for students and customers, radioisotope production, as well as a training reactor. Initial criticality of the NETL TRIGA reactor was achieved on March 12, 1992, making it one of the newest test reactor facilities in the US. The neutron energy spectra, uncertainties, and covariance matrices are presented as well as a neutron fluence map of the experiment area of the cavity. For an unmoderated condition, the neutron fluence at the center of BP 1/5, at the adjacent core axial centerline, is about 8.2×10 12 n/cm 2 per MJ of reactor energy. About 67% of the neutron fluence is below 1 keV and 22% above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is roughly 1.6×10 12 n/cm 2 per MJ of reactor energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting RF Gun with High Current and the Capability to Generate Polarized Electron Beams

High-current low-emittance CW electron beams are indispensable for nuclear and high-energy physics fixed target and collider experiments, cooling high energy hadron beams, generating CW beams of monoenergetic X-rays (in FELs) and gamma-rays (in Compton sources). Polarization of electrons in these beams provides extra value by opening a new set of observables and frequently improving the data quality. We report on the upgrade of the unique and fully functional CW SRF 1.25 MeV SRF gun, built as part of the Coherent electron Cooling (CeC) project, which has demonstrated sustained CW operation with CsK2Sb photocathodes generating electron bunches with record-low transverse emittances and record-high bunch charge exceeding 10 nC. We propose to extend the capabilities of this system to high average current of 100 milliampere in two steps: increasing the current 30-fold at each step with the goal to demonstrate reliable long-term operation of the high-current low-emittance CW SRF guns. We also propose to test polarized GaAs photocathodes in the ultra-high vacuum (UHV) environment of the SRF gun, which has never been successfully demonstrated in RF accelerators.

43 PARTICLE ACCELERATORS↗

Synthesis and Single Crystals of Refractory Oxides of Lanthanides and Thorium

At the completion of this program, we can report that we developed a considerable degree of technical improvements in our ability to perform hydrothermal reactions at high temperatures and pressures. We can now routinely perform reactions at 700-750°C and 200 MPa. Currently we are in the process of exploiting this new technology synthesizing a range of exotic new materials investigating relatively poorly understood materials. Our initial efforts focused on the chemistry of rare earth oxides with tetravalent and pentavalent oxides. We recently published a study of the lanthanides with Nb 5+ and Ta 5+ ions, where we grew oxides such as RENdO 4 and RETaO 4 as high quality single crystals. These compounds were targeted as potential hosts for luminescent and scintillation materials, particularly given that they are among the densest oxide hosts and hence have good potential as absorbers for high energy radiation like X-rays and gamma rays. We also isolated a range of unusual new rare earth tantalates with very complex structures. indicating that the chemistry is very sensitive to conditions. We performed some fairly comprehensive examinations of the solid-state chemistry of rare earth ions with various tetravalent metal ions especially Si 4+ , Ge 4+ , Sn 4+ and Ti 4+ . Given the potential role of rare earth silicates in immobilizing radioactive waste elements in long-term storage, and the similarity of our hydrothermal fluids with known geological conditions, this chemistry continues to be relevant. We prepared an extensive series of new lanthanide germanates (e.g. RE 13 Ge 6 O 31 (OH), BaRE 10 (GeO 4 ) 4 O 8 ). and found that there is there is almost no overlap between the chemistry of the rare earth silicates. Stannic oxide (SnO 2 ) is much more refractory and requires higher temperatures and of mineralizer concentrations. One significant result is the growth of RE 2 Sn 2 O 7 pyrochlore single crystals. These are of interest because the rare earth stannate pyrochlores are known to display a wide range of magnetic frustration such as spin ice behavior. We grew high quality single crystals of rare earth germanate and stannate pyrochlores and this led to a collaboration with Professor Kate Ross at Colorado State. Preliminary measurements, indicate that the crystals contain no detectable defects or site disorder. Initial neutron diffraction on single crystals was performed at Oak Ridge, and more detailed experiments involving the Ross group are underway at both NIST and ORNL. This particular chemistry has turned out to be the most potentially significant work on this project and the collaborative effort with Prof. Ross is the topic of a DoE renewal project on quantum materials. Our initial foray into the hydrothermal chemistry of rare earth titanates has also been very promising and a range of cubic and polar ferroic phases of the light rare earths RE 2 Ti 2 O 7 (RE = La - Pr) in the P2 1 phase. We also discovered an interesting new phase Ce 2 Ti 4 O 11 that can have implications in heavy metal immobilization and storage. along with a series of new rare earth titanates (La 5 Ti 4 O 15 (OH) Sm 3 TiO 5 (OH) 3 and Lu 5 Ti 2 O 11 (OH) with exceptionally complex structures. One interesting sidelight has been high temperature hydrothermal chemistry terbium, including the growth of large crystals of TbO(OH). This is not a new compound but it is the first time it has been grown as large single crystals. The Tb atom density is almost as high as that in Tb 2 O 3 and has a very high Verdet constant (ca. 70), making it a very attractive candidate as a Faraday rotator. Unfortunately it is not in a cubic structure but he material is hard, stable, pure and inexpensive, so should still be an attractive Faraday oscillator. We recently received a patent on this material. We also synthesized K 2 Tb(Ge 2 O 7 ) containing stable octahedral Tb 4+ ions, which appears to be the first example of a well-characterized Tb 4+ complex. Given that Tb 4+ has been proposed as a benign surrogate for more treacherous tetravalent ions such as Cf 4+ and Bk 4+ , we think that Tb 4+ silicates can be a particularly useful study for actinide immobilization and related work. We also began reaction studies with rare earths and both ReO 2 and RuO 2 . These resulted in large single crystals of species like RE 5 Ru 2 O 12 , RE 4 Re 2 O 11 , REReO 4 and RE 2 ReO 5 . Several of these samples have already been sent to ORNL for magnetic and neutron diffraction studies.

36 MATERIALS SCIENCE↗

Structural Changes in Molten Salt Fuel and/or Waste Stream Compounds Cs 2 UCl 6 and Cs 2 UO 2 Cl 4 from Room Temperature to Melting and Related Materials [Slides]

Perovskite phases have been explored in recent literature as waste forms for long term storage of radioactive waste from molten salt reactors specifically. Synthesis of new halide perovskite phases can inform these efforts as well as molten salt reactor chemistry in general. Inorganic perovskites have also shown promise as new scintillating materials for detection of X-rays and gamma rays. Modifying the structure and chemistry of these compounds, perhaps with organic components, could be used to synthesize new scintillating compounds or modify the properties of existing ones. Both U 6+ and U 4+ readily form compounds with a striking similarity to vacancy ordered perovskites (Cs 2 UO 2 Cl 4 and Cs 2 UCl 6 ). Each of these compounds is relevant to molten salt reactor chemistry and/or waste streams. These phases could from in uranium chloride salt systems or waste streams: Cs being a fission product.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Relativistic Laser Plasma Interactions At The Highest Intensities

High energy density science (HEDS) explores the nature of matter under extreme conditions of temperature and pressure. It is of fundamental importance and has many applications such as facilitating imaging with ions, neutrons, x-rays, and gamma rays with new applications being developed, including materials processing and medical therapies. In this project, we used high power, ultrashort pulse lasers to reach HEDS conditions. We have shown that low-cost, liquid crystal film based, double plasma mirror systems can be used to greatly improve laser pulse contrast while still maintaining high power and excellent spatial mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum dot lightning detection and warning system and method

A quantum dot (QD) lightning detection and warning (LDW) system and method. This LDW system and method find broader applicability to spark and other transient optical event detection as well. The QDs are operable for receiving ultraviolet (UV), infrared (IR), visible, x-ray, and/or gamma ray radiation emanating from lightning or the like and generating visible radiation that may be detected and utilized to generate topological event information, such that property, human life, and the like may be safeguarded.

Bahritdinov, Farhod↗

Burst-mode chirped pulse amplification method

A method for increasing the MeV hot electron yield and secondary radiation produced by short-pulse laser-target interactions with an appropriately high or low atomic number (Z) target. Secondary radiation, such as MeV x-rays, gamma-rays, protons, ions, neutrons, positrons and electromagnetic radiation in the microwave to sub-mm region, can be used, e.g., for the flash radiography of dense objects.

Bude, Jeffrey D.↗

Inorganic ternary halide semiconductors for hard radiation detection

Methods and devices for detecting incident radiation, such as incident X-rays, gamma-rays, and/or alpha particle radiation are provided. The methods and devices use high purity, high quality single-crystals of inorganic semiconductor compounds, including solid solutions, having the formula AB2X5, where A represents Tl or In, B represents Sn or Pb, and X represents Br or I, as photoelectric materials.

Kanatzidis, Mercouri G.↗

Limits on Leptonic TeV Emission from the Cygnus Cocoon with Swift-XRT

$\gamma$-ray observations of the Cygnus Cocoon, an extended source surrounding the Cygnus X star-forming region, suggest the presence of a cosmic ray accelerator reaching energies up to a few PeV. The very-high-energy (VHE; 0.1-100~TeV) $\gamma$-ray emission may be explained by the interaction of cosmic-ray hadrons with matter inside the Cocoon, but an origin of inverse Compton radiation by relativistic electrons cannot be ruled out. Inverse Compton $\gamma$-rays at VHE are accompanied by synchrotron radiation peaked in X-rays. Hence, X-ray observations may probe the electron population and magnetic field of the source. We observed eleven fields in or near the Cygnus Cocoon with the Neil Gehrels Swift Observatory's X-Ray Telescope (Swift-XRT) totaling 110 ksec. We fit the fields to a Galactic and extra-galactic background model and performed a log-likelihood ratio test for an additional diffuse component. We found no significant additional emission and established upper limits in each field. By assuming that the X-ray intensity traces the TeV intensity and follows an dN/dE ∝ E -2.5 spectrum, we obtained a 90% upper limit of F X < 8.7 x 10 -11 erg cm -2 s -1 or 5.2 x10 -11 erg cm -2 s -1 on the X-ray flux of the entire Cygnus Cocoon between 2 and 10 keV depending on the choice of hydrogen column density model. This suggests that no more than one quarter of the $\gamma$-ray flux at 1 TeV is produced by inverse Compton scattering, when assuming an equipartition magnetic field of ~20 μG.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute efficiency response of the γ-ray spectrometer GRETINA for high-energy γ rays up to 6 MeV

GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array), a state-of-the-art γ-ray tracking spectrometer, has been instrumental in advancing nuclear structure studies, particularly in experiments using fast beams of rare isotopes where the γ rays emitted in flight are subject to large Doppler shifts. This work presents an experimental determination of the γ-ray detection efficiency of GRETINA at energies up to 6 MeV. The high-energy γ rays originated from states that were populated in nucleon-removal reactions from a projectile beam at an intermediate beam energy of about 85 MeV/nucleon. Utilizing γ-γ coincidences, efficiency values were extracted in-beam and translated into a source efficiency at rest employing GEANT4 Monte Carlo simulations. A systematic discrepancy in the efficiency of the forward-positioned detectors was identified which is attributed to specific dead-time effects caused by high-energy light-particle events prevalent at forward angles, generating signals in the Ge crystals that saturate the preamplifier’s first stage. Furthermore, this study provides refined efficiency benchmarks for in-beam experiments, improving the accuracy of quantitative γ-ray spectroscopy analyses with GRETINA and GRETA (Gamma Ray Energy Tracking Array) in the future.

GRETINA↗

Passive high explosive neutron inspection (PHENIX): a new method to confirm the presence or absence of high explosives for nuclear treaty verification

Advanced instruments and methods need to be developed now to create a technical basis to support the negotiation of future nuclear arms control treaties. One new capability that is anticipated is the ability to confirm either the declared presence or declared absence of high explosive (HE) material in the presence of special nuclear material (SNM). Towards this goal, Passive HE Neutron Inspection (PHENIX) has been developed and demonstrated as a method for confirming the presence or absence of HE in the presence of plutonium. The method exploits the inherent presence of neutrons associated with the decay of plutonium as an internal probe source for performing prompt gamma-ray neutron activation analysis (PGNAA), searching for the presence of HE as revealed by the emission of characteristic gamma rays following neutron absorption in hydrogen and nitrogen which are building blocks of present-day, military-grade HE. Tests using stoichiometrically-correct hemishells of mock HE with plutonium show that a system can be expected to positively confirm the presence or absence of these signatures, supporting determination of HE presence or absence with Pu, in a few hours. To protect other potentially sensitive gamma-ray signatures from a treaty accountable item, an analog information barrier has been conceptualized and tested which physically prevents the collection of gamma-ray spectral data outside of user selected energy windows strategically chosen to view only narrow spectral regions corresponding to the hydrogen (2223.2 keV) and nitrogen (9807.2 keV, 10,318.2 keV, and 10,829.2 keV) PGNAA signatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Genetic algorithm optimization of tin–copper graded shielding for improved plutonium safeguards measurements

Plutonium nuclear material safeguards is essential to ensure that states do not divert plutonium to clandestine nuclear weapons programs. Traditional safeguards methods rely on correlated neutron measurements. Detection systems based on organic scintillators, which are sensitive to fast neutrons and photons, are gaining support for use in safeguards applications due to increased capabilities and shorter measurement times compared to the current state-of-the-art. A drawback of organic scintillators in plutonium measurements is data throughput limitations; 241 Am builds up in plutonium samples and emits 60-keV gamma rays with a high specific activity. In this work, a genetic algorithm is used to design graded shielding made of tin and copper to attenuate the 60-keV gamma rays. The shield is designed to limit the attenuation of the higher-energy, fission photons, because fission photons can be used as a signature. The genetic algorithm optimization takes days to run, while a complete search space exploration would take years. The genetic algorithm was run for different levels of 60-keV gamma-ray attenuation, and the thickness of the required shielding layers was determined at each level. Tin–copper shielding was placed in front of an array of organic scintillation detectors for a measurement of approximately 4.5 kg of alpha-phase, weapons-grade plutonium, an AmLi source, and a 252 Cf source. We show that the shield successfully attenuated low-energy, non-fission gamma rays, which significantly improved the organic scintillator performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A Preliminary Investigation for the Use of Digital Gamma-Gamma Coincidence Spectrometry to Determine 239 Pu

Gamma-ray spectrometry is one of the most effective ways to determine the activity of 239 Pu, depending on activity levels. However, often high backgrounds in complex spectra with low amounts of 239 Pu can increase detection limits. The effectiveness of the use of gamma-gamma spectrometry in the characterization of 239 Pu was studied for the first time. Using the XIA Pixie-16 digital pulse processor, the gamma-gamma system was studied to establish unshielded background radiation, source to detector distances, Poisson statistics and gating of several gamma-rays from 239 Pu. The results clearly show that the distance between gamma ray spectrometers has a much bigger effort in counting statistics for the gamma-gamma coincidence detectors than a single detector. In addition, measurements demonstrated the background radiation to be virtually negligible, meaning gammagamma spectroscopy can still be very effective without requiring the usual lead shielding. Other measurements were taken to assure Poisson statistics were attained in the digital system. Preliminary measurements revealed 3 orders of magnitude background reduction for the measurement of 239 Pu using gated gamma-rays.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lung Cancer in the Mayak Workers Cohort: Risk Estimation and Uncertainty Analysis

The workers at the Mayak nuclear facility near Ozyorsk, Russia are a primary source of information about exposure to radiation at low-dose rates, since they were subject to protracted exposures to external gamma rays and to internal exposures from plutonium inhalation. Here we re-examine lung cancer mortality rates and assess the effects of external gamma and internal plutonium exposures using recently developed Monte Carlo dosimetry systems. Using individual lagged mean annual lung doses computed from the dose realizations, we fit excess relative risk (ERR) models to the lung cancer mortality data for the Mayak Workers Cohort using risk-modeling software. We then used the corrected information matrix (CIM) approach to widen the confidence intervals of ERR by taking into account the uncertainty in doses represented by multiple realizations from the Monte Carlo dosimetry systems. Findings of this work revealed that there were 930 lung cancer deaths during follow-up. Plutonium lung doses (but not gamma doses) were generally higher in the new dosimetry systems than those used in the previous analysis. This led to a reduction in the risk per unit dose compared to prior estimates. The estimated ERR/Gy for external gamma-ray exposure was 0.19 (95% CI: 0.07 to 0.31) for both sexes combined, while the ERR/Gy for internal exposures based on mean plutonium doses were 3.5 (95% CI: 2.3 to 4.6) and 8.9 (95% CI: 3.4 to 14) for males and females at attained age 60. Accounting for uncertainty in dose had little effect on the confidence intervals for the ERR associated with gamma-ray exposure, but had a marked impact on confidence intervals, particularly the upper bounds, for the effect of plutonium exposure [adjusted 95% CIs: 1.5 to 8.9 for males and 2.7 to 28 for females]. In conclusion, lung cancer rates increased significantly with both external gamma-ray and internal plutonium exposures. Accounting for the effects of dose uncertainty markedly increased the width of the confidence intervals for the plutonium dose response but had little impact on the external gamma dose effect estimate. Adjusting risk estimate confidence intervals using CIM provides a solution to the important problem of dose uncertainty. This work demonstrates, for the first time, that it is possible and practical to use our recently developed CIM method to make such adjustments in a large cohort study.

uncertainty, radiation risk estimation, Mayak Prod↗