Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

MAXIMUM LIKELIHOOD FITTING OF X-RAY POWER DENSITY SPECTRA: APPLICATION TO HIGH-FREQUENCY QUASI-PERIODIC OSCILLATIONS FROM THE NEUTRON STAR X-RAY BINARY 4U1608-522

High-frequency quasi-periodic oscillations (QPOs) from weakly magnetized neutron stars display rapid frequency variability (second timescales) and high coherence with quality factors up to at least 200 at frequencies about 800-850 Hz. Their parameters have been estimated so far from standard min({chi}{sup 2}) fitting techniques, after combining a large number of power density spectra (PDS), to have the powers normally distributed (the so-called Gaussian regime). Before combining PDS, different methods to minimize the effects of the frequency drift to the estimates of the QPO parameters have been proposed, but none of them relied on fitting the individual PDS. Accounting for the statistical properties of PDS, we apply a maximum likelihood method to derive the QPO parameters in the non-Gaussian regime. The method presented is general, easy to implement, and can be applied to fitting individual PDS, several PDS simultaneously, or their average, and is obviously not specific to the analysis of kHz QPO data. It applies to the analysis of any PDS optimized in frequency resolution and for low-frequency variability or PDS containing features whose parameters vary on short timescales, as is the case for kHz QPOs. It is equivalent to the standard {chi}{sup 2} minimization fitting when the number of PDS fitted is large. The accuracy, reliability, and superiority of the method is demonstrated with simulations of synthetic PDS, containing Lorentzian QPOs of known parameters. Accounting for the broadening of the QPO profile, due to the leakage of power inherent to windowed Fourier transforms, the maximum likelihood estimates of the QPO parameters are asymptotically unbiased and have negligible bias when the QPO is reasonably well detected. By contrast, we show that the standard min({chi}{sup 2}) fitting method gives biased parameters with larger uncertainties. The maximum likelihood fitting method is applied to a subset of archival Rossi X-ray Timing Explorer data of the neutron star X-ray binary 4U1608-522, for which we show that the lower kHz QPO parameters can be measured on timescales as short as 8 s. To demonstrate the potential use of the results of the maximum likelihood method, we show that in the observation analyzed the time evolution of the frequency is consistent with a random walk. We then show that the broadening of the QPO due to the frequency drift scales as {radical}T, as expected from a random walk (T is the integration time of the PDS). This enables us to estimate the intrinsic quality factor of the QPO to be {approx}260, whereas previous analysis indicated a maximum value around 200.

79 ASTRONOMY AND ASTROPHYSICS↗

ELM frequency enhancement and discharge modification through lithium granule injection into EAST H-modes

The injection of impurity granules into fusion research discharges can serve as a catalyst for ELM events. For sufficiently low ELM frequencies, and granule sizes above a threshold, this can result in full control of the ELM cycle, referred to as ELM pacing. For this research, we extend the investigation to conditions where the natural ELM frequency is too high for ELM pacing to be realized. Utilizing multiple sizes of lithium granules and classifying their effects by granule size, we demonstrate that ELM mitigation through frequency multiplication can be used at ELM triggering rates that nominally make ELM pacing unrealizable. We find that above a size threshold, injected granules promptly trigger ELMs and commensurately enhance the ELM frequency. Below this threshold size, injection of an individual granule does not always lead to the prompt triggering of an ELM; however, collective ablation in the edge pedestal region does enhance the ELM frequency. Furthermore, Li granules too small to individually trigger ELMs were injected into EAST H-mode discharges at frequencies up to 2.3 kHz; collectively the granules were observed to enhance the natural ELM frequency up to 620 Hz, resulting in a ~2.4 × multiplication of the natural ELM frequency and a 50% decrease of the ELM size.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cause and impact of low-frequency chirping modes in DIII-D hybrid discharges

Significant variations in MHD activity and fast-ion transport are observed in the DIIID high-beta, steady-state hybrid discharges with a mixture of Electron Cyclotron (EC) waves and Neutral Beam Injection (NBI). When Electron Cyclotron Heating (ECH) or Current Drive (ECCD) is applied, Alfven Eigenmodes (AEs) are usually suppressed and replaced by low-frequency bursting modes. The analysis of a recently compiled database of hybrid discharges suggests that the change of the fast-ion pressure especially the perpendicular pressure is the main factor responsible for the instability transition. The lower ratio of fast-ion injection speed v inj to Alfven speed v alfven and slight drop of safety factor q min during ECCD may also facilitate the transition. The database shows that AEs mainly occur when the fast-ion fraction P f /P total is less than 0.53 and v inj /v alfven is greater than 0.50, while low-frequency bursting modes appear in the opposite regime. In this research, P f and P total are the central fast-ion pressure from classical prediction and total plasma pressure, respectively. The reason why the instability transition correlates with P f /P total and v inj /v alfven is that they can significantly modify the drive of low-frequency bursting modes and AEs. The explanation is supported by the observation that low-frequency bursting modes are rarely seen in the hybrids with NBI only, with EC waves and counter-NBI, or with high plasma density. A careful check of the low-frequency bursting modes suggests that they are mainly chirping (neoclassical) tearing modes [referred to as chirping (N)TM], i.e. the mode frequency firstly jumps up from the steady (N)TM frequency, then chirps down, and finally returns to the steady (N)TM frequency. Sometimes, the (N)TMs are fully stabilized and replaced with pure fishbones. Lastly, the resonance condition calculation and ’Kick’ model simulations suggest that (N)TMs and fishbones can interact through modification of the fast ion distribution in phase space, which influences the drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Global mean frequency increases of daily and sub-daily heavy precipitation in ERA5

Abstract Changes in heavy precipitation frequency can be viewed as a change in the event return period, a common metric of risk. Compared with intensity, frequency changes are less well-studied and past work has largely been constrained to analysis of well-instrumented regions. We exploit the latest ERA5 reanalysis and its global hourly accumulations at 1/4° spatial resolution and apply a metric that captures frequency changes across both wet and dry regions. According to ERA5 and in a global average sense, during 1989–2018, hourly events that occurred once per year in 1979–1988 increased in frequency by 71 (53–93, 95% range) %, while the one day per year heavy event frequency increased by 44 (37–54) %. Thus, hourly events that occurred once per year in the baseline decade are on track to double in frequency by 2021–2030, and the daily events by 2047–2056. Furthermore, our results replicate prior findings that relative frequency increases are larger for increasingly rare events, and for the first time we quantify that mean frequency increases have been greater over ocean than land. Ocean increases are larger by factors of 3.0 and 2.1 for the hourly and daily events that occurred once per year in 1979–1988, respectively.

Environmental Sciences & Ecology↗

Improved Controller Design of Grid Friendly™ Appliances for Primary Frequency Response

The Grid Friendly$^\textrm{TM}$ Appliance~(GFA) controller, developed at Pacific Northwest National Laboratory, can autonomously switch off the appliances by detecting the under-frequency events. In this paper, the impacts of curtailing frequency threshold on the performance of frequency responsive GFAs are carefully analyzed first. The current method of selecting curtailing frequency thresholds for GFAs is found to be insufficient to guarantee the desired performance especially when the frequency deviation is shallow. In addition, the power reduction of online GFAs could be so excessive that it can even impact the system response negatively. As a remedy to the deficiency of the current controller design, a different way of selecting curtailing frequency thresholds is proposed to ensure the effectiveness of GFAs in frequency protection. Moreover, it is also proposed to introduce a supervisor at each distribution feeder to monitor the curtailing frequency thresholds of online GFAs and take corrective actions if necessary.

Lian, Jianming↗

Hierarchical Decentralized Control Strategy for Demand-Side Primary Frequency Response

The Grid Friendly$^\textrm{TM}$ Appliance~(GFA) controller, developed at Pacific Northwest National Laboratory, was designed for the purpose of autonomously switching off appliances by detecting under-frequency events. In this paper, a new frequency responsive load~(FRL) controller is first proposed by extending the functionality of the original GFA controller. The proposed FRL controller can autonomously switch on (or off) end-use loads by detecting over-frequency (or under-frequency) events through local frequency measurement. Then, a hierarchical decentralized control framework is developed for engaging the end-use loads to provide primary frequency response with the proposed FRL controller. The developed framework has several important features that are desirable in terms of providing primary frequency control. It not only exclusively maintains the autonomous operation of the end-use loads, but also effectively overcomes the stability issue associated with high penetration of FRLs. The simulation results illustrate the effectiveness of the developed hierarchical control framework for providing primary frequency response with the proposed FRL controller.

Lian, Jianming↗

Model-Based Reconstruction for Multi-Frequency Collimated Beam Ultrasound Systems

Collimated beam ultrasound systems are a technology for imaging inside multi-layered structures such as geothermal wells. These systems work by using a collimated narrow-band ultrasound transmitter that can penetrate through multiple layers of heterogeneous material. A series of measurements can then be made at multiple transmit frequencies. However, commonly used reconstruction algorithms such as Synthetic Aperture Focusing Technique (SAFT) tend to produce poor quality reconstructions for these systems both because they do not model collimated beam systems and they do not jointly reconstruct the multiple frequencies. Here, in this article, we propose a multi-frequency ultrasound model-based iterative reconstruction (UMBIR) algorithm designed for multi-frequency collimated beam ultrasound systems. The combined system targets reflective imaging of heterogeneous, multi-layered structures. For each transmitted frequency band, we introduce a physics-based forward model to accurately account for the propagation of the collimated narrow-band ultrasonic beam through the multi-layered media. We then show how the joint multi-frequency UMBIR reconstruction can be computed by modeling the direct arrival signals, detector noise, and incorporating a spatially varying image prior. Results using both simulated and experimental data indicate that multi-frequency UMBIR reconstruction yields much higher reconstruction quality than either single frequency UMBIR or SAFT.

47 OTHER INSTRUMENTATION↗

Structure of Magnetic Plasma Fluctuations in the Uragan-3M Torsatron at Rare Collision Frequencies

Fluctuations of the poloidal component of the plasma magnetic field in the frequency range of 0.5–50 kHz are studied in the Uragan-3M (U-3M) torsatron. Hydrogen plasma is produced and heated by RF fields at frequencies close to that of the ion cyclotron. The studies are carried out using a set of 15 magnetic sensors installed in one of the torus cross sections. RF heating provided the plasma with rare collision frequencies and the presence of the bootstrap current. The study is carried out when the maximum amplitude of magnetic fluctuations is observed and their connection with the plasma energy content is noticeable. Two types of vibrations are observed. In the first type, the current structure rotates with a certain frequency mainly in the direction of the rotation of electrons in the magnetic field, and the amplitude varies slowly with time (the rotating structure). For the second type, the spatial structure does not rotate, but its amplitude changes with a certain frequency (the standing structure). The frequencies of fluctuations and rotations are close for structures with a given poloidal wave number. The standing vibration structures with different poloidal wave numbers in this frequency range are correlated. The maximum amplitude of the rotating structures is observed with m = 2, and for the standing structures with m = 3 and reaches the values of B-tilde ≤ 0.3 G in the confinement region. The vibration frequency does not depend on poloidal wave number m for the studied cases; m = 0, 1, 2, 3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELM frequency enhancement and discharge modification through lithium granule injection into EAST H-modes

The injection of impurity granules into fusion research discharges can serve as a catalyst for ELM events. For sufficiently low ELM frequencies, and granule sizes above a threshold, this can result in full control of the ELM cycle, referred to as ELM pacing. For this research, we extend the investigation to conditions where the natural ELM frequency is too high for ELM pacing to be realized. Utilizing multiple sizes of lithium granules and classifying their effects by granule size, we demonstrate that ELM mitigation through frequency multiplication can be used at ELM triggering rates that nominally make ELM pacing unrealizable. We find that above a size threshold, injected granules promptly trigger ELMs and commensurately enhance the ELM frequency . Below this threshold size, injection of an individual granule does not always lead to the prompt triggering of an ELM; however, collective ablation in the edge pedestal region does enhance the ELM frequency. Specifically, Li granules too small to individually trigger ELMs were injected into EAST H-mode discharges at frequencies up to 2.3 kHz; collectively the granules were observed to enhance the natural ELM frequency up to 620 Hz, resulting in a ~2.4x multiplication of the natural ELM frequency and a 50% decrease of the ELM size.

Granules↗

Integrated reference cavity with dual-mode optical thermometry for frequency correction

Photonic integrated resonators have advantages over traditional benchtop cavities in terms of size, weight, and cost with the potential to enable applications that require spectrally pure light. However, integrated resonators suffer from temperature-dependent frequency variations and are sensitive to external environmental perturbations, which hinders their usage in precision frequency applications. One solution is to use interrogation of the cavity temperature through dual-mode optical thermometry (DMOT) by measuring the shift of the resonance frequency difference between two polarization or optical frequency modes. Yet this approach has only been demonstrated in bulk-optic whispering gallery mode and fiber resonators. In this paper, we implement dual-mode optical thermometry in an ultra-high Q integrated silicon nitride resonator. A dual-mode resonance frequency difference temperature sensitivity of 188 ± <#comment/> 15 M H z / K is measured. We demonstrate feedforward DMOT frequency correction that, under an applied external temperature ramp, is able to reduce the optical frequency change to 0.31 kHz/s as compared to an uncorrected 10.03 kHz/s, a factor of 30 × <#comment/> reduction. These results show promise for on-chip frequency correction solutions for quantum, metrology, atomic, and coherent optical communications applications.

Zhao, Qiancheng (ORCID:0000000206968667)↗

Quantitative Assessment of Detection Frequency for the INL Ambient Air Monitoring Network

A quantitative assessment of the Idaho National Laboratory (INL) air monitoring network was performed using frequency of detection as the performance metric. The INL air monitoring network consists of 37 low-volume air samplers in 31 different locations. Twenty of the samplers are located on INL (onsite) and 17 are located off INL (offsite). Detection frequencies were calculated using both BEA and ESER laboratory minimum detectable activity (MDA) levels. The CALPUFF Lagrangian puff dispersion model, coupled with 1 year of meteorological data, was used to calculate time-integrated concentrations at sampler locations for a 1-hour release of unit activity (1 Ci) for every hour of the year. The unit-activity time-integrated concentration (TICu) values were calculated at all samplers for releases from eight INL facilities. The TICu values were then scaled and integrated for a given release quantity and release duration. All facilities modeled a ground-level release emanating either from the center of the facility or at a point where significant emissions are possible. In addition to ground-level releases, three existing stacks at the Advanced Test Reactor Complex, Idaho Nuclear Technology and Engineering Center, and Material and Fuels Complex were also modeled. Meteorological data from the 35 stations comprising the INL Mesonet network, data from the Idaho Falls Regional airport, upper air data from the Boise airport, and three-dimensional gridded data from the weather research forecasting model were used for modeling. Three representative radionuclides identified as key radionuclides in INL’s annual National Emission Standards for Hazardous Air Pollutants evaluations were considered for the frequency of detection analysis: Cs-137 (beta-gamma emitter), Pu-239 (alpha emitter), and Sr-90 (beta emitter). Source-specific release quantities were calculated for each radionuclide, such that the maximum inhalation dose at any publicly accessible sampler or the National Emission Standards for Hazardous Air Pollutants maximum exposed individual location (i.e., Frenchman’s Cabin) was no more than 0.1 mrem yr–1 (i.e., 1% of the 10 mrem yr–1 standard). Detection frequencies were calculated separately for the onsite and offsite monitoring network. As expected, detection frequencies were generally less for the offsite sampling network compared to the onsite network. Overall, the monitoring network is very effective at detecting the potential releases of Cs-137 or Sr-90 from all sources/facilities using either the ESER or BEA MDAs. The network was less effective at detecting releases of Pu-239. Maximum detection frequencies for Pu-239 using ESER MDAs ranged from 27.4 to 100% for onsite samplers and 3 to 80% for offsite samplers. Using BEA MDAs, the maximum detection frequencies for Pu-239 ranged from 2.1 to 100% for onsite samplers and 0 to 5.9% for offsite samplers. The only release that was not detected by any of the samplers under any conditions was a release of Pu-239 from the Idaho Nuclear Technology and Engineering Center main stack (CPP-708). The methodology described in this report could be used to improve sampler placement and detection frequency, provided clear performance objectives are defined.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report on Depth-Dependent Q from Frequency-Dependent Lg Q

As a phase that travels through the crustal waveguide, Lg samples the velocity and attenuation structure of the crust. We have developed methods (Pasyanos et al., 2009a; Pasyanos et al., 2009b) to estimate Qp and Qs of the crust and upper mantle from the amplitudes of regional phases, and have applied it to a number of regions around the world, and over a broad frequency band (0.5 - 10 Hz). In prior attenuation modeling, Lg phase amplitudes are able to effectively distinguish the high Q (low attenuation) of old stable cratonic crust from the low Q (high attenuation) of more recently active tectonic regions. For a variety of purposes (e.g. waveform modeling, seismic hazard, etc.), it is useful to have more information on the depth-dependence of the Q structure in the crust. One obvious candidate for doing this is using the frequency-dependence information of Lg Q, in the manner of surface waves. Unfortunately, however, Lg samples the whole of the crust without much differentiation with respect to frequency that is characteristic of fundamental mode surface waves. Lg is generally thought to be the sum of supercritically reflected S-waves trapped in the crustal waveguide (e.g. Xie and Lay, 1994). The phase can also be modeled as a superposition of surface waves. At lower frequencies, it is primarily composed of fundamental and low-order surface waves, while at higher frequencies, it is comprised purely of many high-order surface waves. The low-order surface waves that comprise Lg in low frequency bands (< 1 Hz) are preferentially sensitive to shallow earth structure, such as sedimentary basins and upper crust, while high-order surface waves have a more homogenized sensitivity to the whole crust. Furthermore, at the lower frequencies, we might expect to see some differentiation in the sensitivity between early Lg (herein referred to as Lg1) and late Lg (referred to as Lg2) where the latter is comprised of lower-order surface waves and, hence, shallower structure. Therefore, we might expect to see the signature of shallow features, primarily the lower Q of sediments as compared to crystalline crust, at lower frequencies and in later arriving Lg amplitudes.

58 GEOSCIENCES↗

Online Monitoring of Medium Voltage Cable Systems with Spread Spectrum Time Domain and Frequency Domain Reflectometry

In-service failures of wave energy convertor (WEC) cable systems can have a significant cost and power availability impact. Close parallel research 2019 data showed > 1B£ and 9 Terra-Watt-Hours associated with global off-shore wind (OSW) cable failures (Strang-Moran 2020). OSW is a closely related technology but currently is significantly cheaper than WEC technology. For wave energy to compete, the problem of reliable cable transmission must be mitigated. This project develops isolation technology to allow online high frequency reflectometry testing of medium voltage cables (1 to 10 kV and higher) without arcing or damage to the test instrument. Online spread spectrum time domain reflectometry (SSTDR) testing has been established for low voltage cable systems in the aircraft and rail industry and the ability to detect and locate cable flaws of interest is well understood. Extending reflectometry testing to medium voltage systems could enable detection of cable damage before failures occur thereby allowing repair and replacement of damaged cable segments to be scheduled and managed. The seedling project succeeded to pass and receive high frequency SSTDR signals onto a cable up to 1 kV using a parallel trace isolation circuit board that can be connected onto the test cable. The approach used a novel circuit design for which an invention disclosure has been filed. A proposed sapling project would extend the technology toward the higher operating voltages used by WEC systems, thereby enabling online SSTDR cable monitoring. The goal of the seedling project was to extend the capability of the ARENA cable/motor test bed to address medium voltages and to develop a high pass filter isolation architecture to protect the reflectometry instrument from the low frequency (DC – 60 Hz) line voltage while allowing the high frequency diagnostic signal to pass to and from the test instrument to the live line. Initial efforts focused on passive LCR filter circuits to reduce 60 Hz levels below 10 volts from a 10 kV line while allowing the MHz high frequency chirps to pass onto the cables and for mV signals to be detected. We discovered that the parasitic loss behavior of real high voltage components precluded this approach from working. An alternate approach was adapted for the electric field to couple between two parallel traces on a printed circuit board much like a radio-frequency coupler. The challenge here was and is to have the parallel traces close enough to each other to effectively pass the high frequency chirp onto the live line and receive any reflected signal from any encountered impedance change along the cable. This reflected signal will be in the mV range. The traces however must be far enough apart to not allow arcing on the board. A design with 3 mm spacing was determined to allow the high frequency signal to pass onto the live line and receive the mV signal back into the instrument while reducing the 60 Hz voltage amplitude by >80 dB (more than a factor of 10,000) without allowing arcing from across the parallel traces. This was confirmed by simulation and test.

16 TIDAL AND WAVE POWER↗

Response of a store with tunable natural frequencies in compressible cavity flow

Fluid–structure interactions that occur during aircraft internal store carriage were experimentally explored at Mach 0.58–1.47 using a generic, aerodynamic store installed in a rectangular cavity having a length-to-depth ratio of seven. The store vibrated in response to the cavity flow at its natural structural frequencies, and it exhibited a directionally dependent response to cavity resonance frequencies. Cavity tones excited the store in the streamwise and wall-normal directions consistently, whereas the spanwise response to cavity tones was much more limited. Increased surface area associated with tail fins raised vibration levels. The store had interchangeable components to vary its natural frequencies by about 10–300 Hz. By tuning natural frequencies, mode-matched cases were explored where a prominent cavity tone frequency matched a structural natural frequency of the store. Mode matching in the streamwise and wall-normal directions produced substantial increases in peak store vibrations, though the response of the store remained linear with dynamic pressure. Near mode-matched frequencies, changes in cavity tone frequencies of only 1% altered store peak vibrations by as much as a factor of two. In conclusion, mode matching in the spanwise direction did little to increase vibrations.

42 ENGINEERING↗

Effects of Nonzero-frequency Fluctuations on Turbulence Spectral Observations

In situ observations of turbulence spectra in space plasmas are usually interpreted as wavenumber spectra, assuming that the fluctuation frequency is negligible in the plasma flow frame. We explore the effects of nonzero frequency in the plasma flow frame on turbulence spectral observations. The finite frequency can be caused by either propagating waves or nonlinear broadening of nonpropagating structures. We show that the observed frequency spectrum can be modified by the nonzero frequency of turbulent fluctuations in several ways. Specifically, (i) frequency broadening results in a minor modification to the observed spectrum, primarily acting as a smoothing kernel of the spectrum near the spectral break, while the asymptotic spectral index remains unchanged; (ii) wave propagation can affect the observed spectral index for anisotropic turbulence. The effect is significant at low frequencies and weaker at high frequencies, leading to a "concave" shape of the observed perpendicular spectrum; (iii) the Doppler shift for forward- and backward-propagating Elsasser modes can result in a nonzero cross helicity for critical-balanced turbulence since the effect of the Doppler shift favors outward-propagating waves systematically, resulting in an observed imbalance. These results may have important implications for the interpretation of solar wind flows observed by Parker Solar Probe.

79 ASTRONOMY AND ASTROPHYSICS↗

Substructure coupling in the frequency domain

Frequency domain analysis was found to be a suitable method for determining the transient response of systems subjected to a wide variety of loads. However, since a large number of calculations are performed within the discrete frequency loop, the method loses it computational efficiency if the loads must be represented by a large number of discrete frequencies. It was also discovered that substructure coupling in the frequency domain work particularly well for analyzing structural system with a small number of interface and loaded degrees of freedom. It was discovered that substructure coupling in the frequency domain can lead to an efficient method of obtaining natural frequencies of undamped structures. It was also found that the damped natural frequencies of a system may be determined using frequency domain techniques.

Source record↗

Local time distribution of the SSC-associated HF-Doppler frequency shifts

The HF-Doppler frequency shift observed at the storm's sudden commencement is composed of a frequency increase (+) and decrease (-), and classified into four types, SCF(+ -), SCF(- +), SCF(+) and SCF(-). Since the latter two types are special cases of the former two types, two different kinds of electrical field exist in the F region and cause the ExB drift motion of plasma. HUANG (1976) interpreted the frequency increase of SCF(+ -) as due to the westward induction electric field proportional to delta H/ delta t and the succeeding frequency decrease due to the eastward conduction electric field which produces ionospheric currents responsible for the magnetic increase on the ground. In spite of his success in interpreting the SCF(+ -), some other interpretations are needed for the explanation of the whole set of SCF's, particularly SCF(- +). Local time distributions of the SCF's are derived from 41 SCF's which are observed on the HF standard signal (JJY) as received in Okinawa (path length =1600 km) and Kokubunji (60 km). It is shown that the SCF(+ -) appears mainly during the day, whereas the SCF(- +) is observed during the night. The results indicate that the preliminary frequency shift (+) of SCF(+ -) and (-) of SCF(- +) is caused by a westward electric field in the dayside hemisphere, while by an eastward electric field in the nightside hemisphere. The main frequency shift (-) of SCF(+ -) and (+) of SCF(- +) is caused by the reversed electric field. Consequently, the preliminary frequency shift is caused by the dusk-to-dawn electric field, while the main frequency shift by the dawn-to-dusk electric field.

Kikuchi, T.↗

Hydrogen masers with cavity frequency switching servos

The stability of the free-running hydrogen maser is limited by pulling of the unperturbed hydrogen transition frequency due to instability of the cavity resonance frequency. While automatic spin-exchange tuning is in principle the more basic and accurate method, the required beam intensity switching and the long servo time constant result in reduced stability for measuring intervals up to 10(exp 6) seconds. More importantly, the spin-exchange tuning method requires a second stable frequency source as a reference, ideally a second hydrogen maser, to get the best results. The cavity frequency switching servo, on the other hand, has very little effect on the maser short term stability, and is fast enough to correct for cavity drift while maintaining the cavity at the spin-exchange tuned offset required to minimize instability due to beam intensity fluctuations. Not only does the cavity frequency switching servo not require a second stable frequency source, but the frequency reference is the atomic hydrogen radiated beam signal, so that no extra RF connections need be made to the cavity, and externally generated signals that would perturb the hydrogen atom need not be transmitted through the cavity. The operation of the cavity frequency switching stabilization method is discussed and the transient response of the servo and certain other aspects of the technique that have potential for achieving improved basic accuracy are illustrated.

Peters, Harry E.↗