Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Experimental Investigation of a Novel Membrane-Based Condensing Heat Exchanger for High Efficiency Furnaces

Building space heating consumes approximately one-third of all global natural gas end use. Higher-efficiency (i.e., condensing) furnaces constitute only about 30% of the annual furnace shipments in the United States because the condensing heat exchangers must use highly expensive, corrosion-resistant materials to be protected from acidic components in the furnace flue gas stream. Increasing the market share of high-efficiency furnaces will reduce greenhouse gas emissions. This study developed and tested a benchtop prototype of a novel membrane-based heat exchanger (MHX) for high-efficiency furnaces to achieve nonacidic condensation via nanoporous membranes. Test results show that both sensible and latent heat were recovered by the MHX, and the fraction of latent heat recovery ranged from about 25% to 45% over the range of operating conditions evaluated. The amount of water condensed through the MHX increased with the increase of flue gas flow rate and decreased with increasing coolant temperature. The fraction of latent heat recovery decreased with the increase of flue gas flow rate and coolant temperature. The pH value of condensed water from the MHX was only mildly acidic, varying from 5.3 to 5.6 without any additional treatment, about 2.0 to 2.3 pH points higher (i.e., less acidic) than typical values for the condensate from conventional condensing furnaces. Therefore, feasibility of the MHX was experimentally verified, and the MHX could enable wider market penetration of highly energy-efficient condensing furnaces by reducing costs associated with managing the acid condensation compared with conventional condensing furnaces, possibly enabling the use of existing vent systems when replacing noncondensing furnaces (due to higher flue gas exit temperatures), and possibly reducing furnace first costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Orthogonal Recursive Bisection (ORB) Based Time Advancement Algorithm for CFD-DEM Solvers

The time integration of the granular phase in coupled computational fluid dynamics (CFD) – discrete element method (DEM) simulations presents a unique computational challenge brought about by the large variations in particle collisional time scales. Particles in the dilute regions of the computational domain can be advanced with large time steps while dense regions require much smaller time increments. However, the time step size in most solvers is globally set as the limit for accuracy and stability imposed by the collisions and is typically orders of magnitude less than that required away from collisions. This work addresses this precise issue and provides a strategy to avoid the use of a global conservative small time step size for the entire set of particles.A novel time stepping algorithm for CFD-DEM solvers using a partitioning approach using orthogonal recursive bisection (ORB) that allows for variable time steps among particles is described and its computational performance is compared against baseline explicit methods, typically used in several CFD-DEM solvers. ORB has advantages of being relatively quick and easy to update incrementally and has the required heuristic behavior (i.e., it will split the region in half with a cluster on each side) when groups of particles are well separated (clustered). The algorithm presented in this work uses a local time stepping approach to resolve collisional time scales for subsets of particles that are present at the leaves of the ORB, thereby resulting in substantial reduction of computational cost. The parallel implementation of this method where a ``knapsack” algorithm is used in tandem with ORB for effective load-balancing is also presented, where a best possible partitioning is obtained based on number of particles and local time-stepping costs. The algorithm is tested against benchmark problems with varying particle distributions that include fluidized bed and riser flow scenarios. Preliminary results indicate that the approach is 2-3X faster than traditional explicit methods for problems that involve both dense and dilute regions, while maintaining the same level of accuracy.

adaptive timestepping↗

Thermally anisotropic building envelope for thermal management: finite element model calibration using field evaluation data

The thermally anisotropic building envelope (TABE) is an active building envelope that redistributes thermal loads in response to weather conditions and building energy demand. Conductive layers throughout the TABE distribute low-grade heat among hydronic loops, altering heat flow direction and intensity. Finite element models of TABE roof and wall panels were developed and calibrated using field evaluation data. The calibration results showed that heat flux differences between the experimental data and finite element models averaged –0.42% and 3.57%, with a maximum mean square error of 1.78 and 3.96 for roof and wall panels, respectively. A reduction in heat flux from the environment to the building living space over the entire testing period (weeks in July/August) was found to be 85% for roof panels and 335% (load reversed) for wall panels. Finally, these results indicate TABE can effectively harness low-grade thermal energy sources to achieve high energy efficiency and promote demand-side management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermally Anisotropic Composites for Heat Redirection and Thermal Management in Building Envelopes

In building envelope systems, thermal management is important from energy conservation and thermal comfort perspectives, and is typically done via insulation, thermal mass, solar control and shading, etc. Thermal anisotropy is commonly utilized in electronics for heat dissipation. This article investigates the feasibility of utilizing thermally anisotropic composites (TACs) to reduce unwanted heat gains and losses through the building envelope by redirecting the heat transfer to or from appropriate heat sinks and sources.Numerical simulations of building envelope components using COMSOL Multiphysics and whole building simulations using EnergyPlus (E+) were performed to estimate the energy savings potential of TACs used in external walls of residential buildings. Application of TACs was compared with baseline walls with cavity insulation as well as with and without exterior continuous insulation (CI). The COMSOL simulations indicated 75% or higher reductions in heat gains when using a TAC coupled with a heat sink compared to an exterior CI case. In terms of energy savings in a hot climate, E+ models estimated cooling energy savings of 19% with a "TAC + heat sink" compared to a baseline wall with only cavity insulation. Further, a small-scale test sample with a TAC-heat sink system was built and tested in a multi-transducer heat flow meter (HFM). The heat sink was a copper tube circulating cold water. The experiments verified the re-direction of heat to a sink and significant reduction in heat transfer through the test specimen. The experiments showed that the heat redirection only occurred in the presence of both thermal anisotropy and water circulation; if either element was missing, the system behaved like a traditional envelope component.

Biswas, Kaushik↗

Influence of Reservoir Convection on Heat Extraction with Closed-Loop Geothermal Systems

Over the past few years, advancements in closed-loop geothermal systems (CLGS), also called advanced geothermal systems (AGS), have sparked a renewed interest in these types of designs. CLGS have certain advantages over traditional and enhanced geothermal systems (EGS), including not requiring in-situ reservoir permeability, conservation of the circulating fluid, and allowing for different fluids, including working fluids directly driving a turbine at the surface. CLGS may be attractive in environments where water resources are limited, rock contaminants must be avoided, and stimulation treatments are not available (e.g., due to regulatory or technical reasons). Despite these advantages, CLGS have some challenges, including limited surface area for heat transfer and requiring long wellbores and laterals to obtain multi-MW output in conduction-only reservoirs. CLGS have been investigated in conduction-only systems. In this paper, we explore the impact of both forced and natural convection on the levels of heat extraction with a CLGS deployed in a hot wet rock reservoir. We bound potential benefits of convection by investigating liquid reservoirs over a range of natural and forced convective coefficients. Additionally, we investigate the effects of permeability, porosity, and geothermal temperature gradient in the reservoir on CLGS outputs. Reservoir simulations indicate that reservoir permeabilities of at least ~100 mD are required for natural convection to increase the heat output with respect to a conduction-only scenario. The impact increases with increasing reservoir temperature. When subject to a forced convection flow field, Darcy velocities of at least 10-7 m/s are required to obtain an increase in heat output.

advanced geothermal systems↗

Analytical model for balling defects in laser melting using rivulet theory and solidification

In laser welding and additive manufacturing communities, the balling (humping) defect is primarily attributed to the Plateau–Rayleigh fluid instability (PRI) with a few authors suggesting fluid jetting and volume conservation as alternative mechanisms. As analytical descriptions of these mechanisms are unavailable, combining them into a single formalism is unfeasible. We present a new model of PRI with higher accuracy, accounting for competition with solidification, to compare the expected behavior with known experimental trends when fluid jetting is neglected. We adapt a rivulet instability model from fluid physics to account for the stabilizing effects of the substrate, which the traditional cylindrical-jet geometry does not account for and estimate the instability growth rate. Our model yields a continuous transition from non-balling to balling hitherto lacking in current literature and predicts instability growth at higher wavelengths with strong sensitivity to the solidification front curvature. While the fluid surface is most unstable for shallow melt pools, the absolute magnitude of balling relevant to printing defects scales with melt pool depth and has a maximum for a given melt pool geometry. Synchrotron-based x-ray radiography of thin samples indicates that PRI growth rates and solidification can be comparable in magnitude and thus compete, as we find in this work. We predict that deviations between model predictions and our experimental results demonstrate the importance of fluid flows and heat transport in the balling process. Our experiments further demonstrate at least one mechanism by which the melt pool length and the balling wavelength are not equivalent, as commonly claimed.

Taylor, Z. [Stanford Univ., CA (United States); SL↗

A dynamic protein interactome drives energy conservation and electron flux in Thermococcus kodakarensis

ABSTRACT Life is supported by energy gains fueled by catabolism of a wide range of substrates, each reliant on the selective partitioning of electrons through redox ( red uction and ox idation) reactions. Electron flux through tunable and regulated protein interactions provides dynamic routes for energy conservation, but how electron flux is regulated in vivo , particularly for archaeal metabolisms that support rapid growth at the thermodynamic limits of life, is poorly understood. Identification of bona fide in vivo protein assemblies and how such assemblies dictate the totality of electron flux is critical to our understanding of the regulation imposed on metabolism, energy production, and energy conservation. Here, 25 key proteins in central metabolic redox pathways in the model, genetically accessible, hyperthermophilic archaeon Thermococcus kodakarensis , were purified to reveal an extensive, dynamic, and tightly interconnected network of protein interactions that responds to environmental cues (such as the availability of various reductive sinks) to direct electron flux to maximize energetic gains. Interactions connecting disparate functions suggest many catabolic and anabolic activities occur in spatial proximity in vivo , and while protein complexes have been historically defined under optimal conditions, many of these complexes appear to maintain alternative partnerships in changing conditions. The totality of the results obtained redefines our understanding of in vivo assemblies driving ancient metabolic strategies supporting the growth of modern Archaea. IMPORTANCE Given the potential for rational genetic manipulations of biofuel- and biotech-promising archaea to yield transformative results for major markets, it is a priority to define how the metabolisms of such species are controlled, at least in part, by in vivo protein assemblies, and from such, define routes of energy flux that can be most efficiently altered toward biofuel or biotechnological gains. Proteinaceous electron carriers (PECs, such as ferredoxins) offer the potential for specific protein–protein interactions to coordinate selective reductive flow. Employing the model, genetically accessible, hyperthermophilic archaeon, Thermococcus kodakarensis , we establish the metabolic protein interactome of 25 key redox proteins, revealing that each redox active protein has a dynamic partnership profile, suggesting catabolic and anabolic activities may occur in concert and in temporal and spatial proximity in vivo . These results reveal critical importance in evaluating the newly identified partnerships and their role and utility in providing regulated redox flux in T. kodakarensis .

Williams, Sere A. (ORCID:0000000235509590)↗

Guidelines and Specifications for Enhanced Durability Evaluation of Insulating Glass and Vacuum Insulating Glass Units

The National Renewable Energy Laboratory (NREL) has conducted research into durability of advanced fenestration technologies for almost thirty years. NREL has recently begun to research potential methods to enhance durability evaluation of present market insulating glass units (IGU). This document outlines a proposed process flow for adoption of these methods by interested parties. The proposed evaluation process flow described below is still a topic of active research at NREL as well as with industry partners. NREL will periodically update this document based on research results, both internal and external to NREL that may inform development of improved durability evaluation. This document is also meant to serve as a guideline for interested parties who may wish to engage in enhanced durability evaluation of IGU's both internally or with external testing laboratories. NREL will work to support adoption of the suggestions in this guideline by interested partners in the hope that these practices are more broadly adopted by the industry. Further research into this area will continue to inform both adaptations of this guideline as well as development of improved durability evaluation standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effectiveness and outcomes of invasive species removal in Hawaiian streams

Despite aquatic invasive species (AIS) being a widely recognized threat to native biodiversity in streams on subtropical and tropical oceanic islands across the Pacific, AIS management has been constrained by concerns that methods of removal could result in more harm than good. In this study, we assessed the effectiveness and outcomes of combining hand-netting and streamside sequestration of native species with AIS removal via three-pass electrofishing tailored for Hawaiian Island watersheds. Removals were conducted in 13 watersheds on the island of O‘ahu following a before-after, control-impact design to assess how AIS removal and post-removal community reassembly varied by surface flow and target species of interest. We found that removals resulted in a sharp reduction in AIS densities without altering native species densities. Removal efficacy was greatest in streams with intermediate mean discharge irrespective of target group or pre-removal AIS densities. Long-term monitoring demonstrated that removals led to persistent shifts in community composition reflecting sustained reductions in AIS densities. These findings indicate that electrofishing can be a valuable tool for AIS management in Hawaiian and other subtropical Pacific island streams, so long as steps are taken to minimize potential harm to at-risk and culturally important native species.

59 BASIC BIOLOGICAL SCIENCES↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Review and Analysis of Heat Transfer Correlations For Horizontal Pseudocritical CO 2 Heat Exchanger Applications

There is significant interest in the development of supercritical carbon dioxide (sCO 2 ) power cycles because of the potential for smaller and more energy efficient systems than a steam Rankine cycle. Heat exchanger designs typically use empirical correlations, but the applicability of these correlations near the CO 2 critical point is a potential issue. Though numerous correlations have been proposed in the literature, there are some disagreements when it comes to the accuracy. The current work recognizes the role of thermophysical properties, and its impacts on the heat transfer correlations and cycle efficiency. Heat transfer correlations proposed for horizontal flow inside circular pipes were analyzed with the help of numerical simulations. Steady state RANS simulations were performed using SST k-w turbulence model to evaluate the Nusselt number empirical correlations. It was found that the most of correlations (except Yoon) produced a Nusselt number that differed significantly with the one predicted numerically. Some of the correlations were developed for pure forced convection regime and as mentioned in Lin et al. do not account for mixed convection or free convection effects. Based on the limited observation, it appears that Yoon et al. predictions match well with the numerically predicted Nusselt Numbers. However, further analysis is required understand the applicability of various correlations and is contingent on accurate measurements or predictions of wall temperature profiles in the axial and the circumferential directions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parallel diffusion operator for magnetized plasmas with improved spectral fidelity

Diffusive transport processes in magnetized plasmas are highly anisotropic, with fast parallel transport along the magnetic field lines sometimes faster than perpendicular transport by orders of magnitude. This constitutes a major challenge for describing non-grid-aligned magnetic structures in Eulerian (grid-based) simulations. Here, the present paper describes and validates a new method for parallel diffusion in magnetized plasmas based on the anti-symmetry representation [Halpern and Waltz, Phys. Plasmas 25, 060703 (2018)]. In the anti-symmetry formalism, diffusion manifests as a flow operator involving the logarithmic derivative of the transported quantity. Qualitative plane wave analysis shows that the new operator naturally yields better discrete spectral resolution compared to its conventional counterpart. Numerical simulations comparing the new method against existing finite difference methods are carried out, showing significant improvement. In particular, we find that combining anti-symmetry with finite differences in diagonally staggered grids essentially eliminates the so-called “artificial numerical diffusion” that affects conventional finite difference and finite volume methods.

Anisotropic diffusion↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemically driven carbon dioxide separation

This project explored the viability of a Ni(OH) 2 based hydroxide exchange membrane carbon capture (HEMCC) device for direct air capture. It is built off an H 2 fuel cell based HEMCC previously developed in the Yushan Yan group at University of Delaware. Taking the same membrane-based, electrochemically driven pH gradient concept, similar flux performance was able to be seen in the Ni(OH) 2 system as the H 2 system when using comparable current densities. The project produced two types of membrane electrode assemblies (MEA). The first was a traditional MEA with two electrodes and a membrane, the second was a flow-through membrane MEA. Consistent performance was achieved with the traditional MEA with an energy cost of 1.1 MWh∙ton -1 and flux of 82 kg∙m -2 ∙yr -1 . This was the most stable of the two designs. This project investigated strategies to improve performance with a flow-through membrane design. Two designs were made, one with a cast phase inversion membrane, and one with powdered membrane layer. The template phase inversion membrane achieved low pressure drop but had performance limitations due to a skin layer of membrane limiting CO 2 gas transport. The powdered membrane layer had better performance but higher pressure drop. Finally, using the powdered membrane, commercial battery materials were able to be used in order to achieve higher flux. This showed that the flow through membrane design does have the capability to overcome flux inefficiencies in the traditional MEA. Moreover, the process design of the system is proposed and given in this project. The process mass and energy balances were calculated for a reference plant of 1000 t/yr CO 2 capture, which contains several subsystems, e.g. air processing subsystem, electrical subsystem, and CO 2 purification and compression subsystem is designed and evaluated. Based on our calculation, When the power consumption for stack is 1 MWh t -1 CO 2 , Additional 382 kWh t -1 CO 2 will be consumed by other subsystem of the plant, i.e. The total power consumption of 1.38 MWh t -1 CO 2 , lower than the final milestone of 1.5 MWh t -1 CO 2 in this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vacuum-assisted carbon molecular sieve membrane reactor for non-oxidative ethane dehydrogenation

Non-oxidative ethane dehydrogenation (EDH) is equilibrium-limited and endothermic. Selective hydrogen removal using a gas-permeable membrane within the EDH reaction zone can overcome the thermodynamic equilibrium, enabling higher ethane conversions. Employing vacuum as the permeation driving force, rather than a sweep gas, enhances the industrial viability of membrane reactors by eliminating additional post-reaction separation units. This study presents a membrane reactor that integrates H 2 -permeable carbon molecular sieve (CMS) hollow fiber membranes embedded in a fixed bed of cobalt in a dealuminated beta zeolite (Co@DeAl-BEA) catalyst, utilizing a vacuum to remove hydrogen efficiently. The CMS membrane exhibits high hydrogen permeance and an excellent H 2 /C 2 H 6 separation factor. The membrane reactor significantly enhanced the ethane conversion under reaction conditions comparable to those reported in the literature. A Langmuir-Hinshelwood kinetic rate expression was developed and incorporated into a one-dimensional steady-state reactor model. The experimentally validated model indicates that increasing the number of hollow fibers improves ethane conversion, although ethane loss to the permeate limits the benefit. The contact area between the catalyst and the membrane limits the reactor performance more than the catalytic throughput. Furthermore, we find that the location of the catalyst packing relative to the hollow fiber membranes influences ethane loss and conversion. Higher reactor pressures and inlet ethane flow rates improve space-time yield at the expense of lower ethane conversion. Increasing reactor temperature or packing length promotes both performance metrics. The EDH membrane reactor demonstrated durability over 200 h of continuous operation, maintaining record-low deactivation rates and high ethylene selectivity. Protocols for catalyst regeneration were developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steam generator model design parameter sensitivity study for small modular reactor system

Here, this study focuses on design parameter sensitivity studies pertaining to several Once-Through Steam Generator (OTSG) model cases both with and without a riser using python and advanced risk assessment and optimization tool, i.e. Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), to support a Small Modular Reactor (SMR) system. The presented Steam Generator (SG) python-based model is a mathematical representation of a steam-generating unit for a Pressurized Water Reactor (PWR)-type SMR system, including fluid flow and heat transfer equations, models, and correlations. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system, such as the Heat Transfer Coefficient (HTC), Reynolds number, Nusselt number, and heat transfer performance. Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in the input parameters. By using RAVEN, detailed design parametric sensitivity studies. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10 % relative changes) for 600 samples. The analysis results give valuable insights into SG system performance, and provide justification for further research and development such as optimized sensor placement, design verification, validation, and optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Open Circuit Switch Fault Management Method of a Multi-Phase Synchronous Buck Converter for EV Charging Application

Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗