Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Efficient Multiblock Method for Aerodynamic Analysis and Design on Distributed Memory Systems

The work presented in this paper describes the application of a multiblock gridding strategy to the solution of aerodynamic design optimization problems involving complex configurations. The design process is parallelized using the MPI (Message Passing Interface) Standard such that it can be efficiently run on a variety of distributed memory systems ranging from traditional parallel computers to networks of workstations. Substantial improvements to the parallel performance of the baseline method are presented, with particular attention to their impact on the scalability of the program as a function of the mesh size. Drag minimization calculations at a fixed coefficient of lift are presented for a business jet configuration that includes the wing, body, pylon, aft-mounted nacelle, and vertical and horizontal tails. An aerodynamic design optimization is performed with both the Euler and Reynolds Averaged Navier-Stokes (RANS) equations governing the flow solution and the results are compared. These sample calculations establish the feasibility of efficient aerodynamic optimization of complete aircraft configurations using the RANS equations as the flow model. There still exists, however, the need for detailed studies of the importance of a true viscous adjoint method which holds the promise of tackling the minimization of not only the wave and induced components of drag, but also the viscous drag.

Reuther, James↗

Coaxial charged particle energy analyzer

A non-dispersive electrostatic energy analyzer for electrons and other charged particles having a generally coaxial structure of a sequentially arranged sections of an electrostatic lens to focus the beam through an iris and preferably including an ellipsoidally shaped input grid for collimating a wide acceptance beam from a charged-particle source, an electrostatic high-pass filter including a planar exit grid, and an electrostatic low-pass filter. The low-pass filter is configured to reflect low-energy particles back towards a charged particle detector located within the low-pass filter. Each section comprises multiple tubular or conical electrodes arranged about the central axis. The voltages on the lens are scanned to place a selected energy band of the accepted beam at a selected energy at the iris. Voltages on the high-pass and low-pass filters remain substantially fixed during the scan.

Kelly, Michael A.↗

The spectral green's function nodal method for multigroup slab-geometry fixed-source S{sub N} problems with anisotropic scattering

A generalization of the spectral Green's function (SGF) method is developed for multigroup, fixed-source, slab-geometry discrete ordinates (S{sub N}) problems with anisotropic scattering. The offered SGF method with the one-node block inversion (NBI) iterative scheme converges numerical solutions that are completely free from spatial truncation errors for multigroup slab-geometry S{sub N} problems with scattering anisotropy of order L, provided L < N. As a coarse-mesh numerical method, the SGF method generates numerical solutions that generally do not give detailed information on the problem solution profile, as the grid points can be located considerably away from each other. Therefore, presented here is a technique for the spatial reconstruction of the coarse-mesh solution generated by the multigroup SGF method. Numerical results are given to illustrate the method's accuracy. (authors)

97 MATHEMATICS AND COMPUTING↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Rate Design Alternatives on Residential Solar Customer Bills. Increased Fixed Charges, Minimum Bills and Demand-based Rates

With rapid growth in energy efficiency and distributed generation, electric utilities are anticipating stagnant or decreasing electricity sales, particularly in the residential sector. Utilities are increasingly considering alternative rates structures that are designed to recover fixed costs from residential solar photovoltaic (PV) customers with low net electricity consumption. Proposed structures have included fixed charge increases, minimum bills, and increasingly, demand rates - for net metered customers and all customers. This study examines the electricity bill implications of various residential rate alternatives for multiple locations within the United States. For the locations analyzed, the results suggest that residential PV customers offset, on average, between 60% and 99% of their annual load. However, roughly 65% of a typical customer's electricity demand is non-coincidental with PV generation, so the typical PV customer is generally highly reliant on the grid for pooling services.

14 SOLAR ENERGY↗

Technoeconomic Design Optimization for Fast Reactors. Part II: Impact of Technoeconomic Constraints on Optimal Design

There is a current drive toward optimizing reactors, particularly small/micro reactors to minimize cost and maximize performance. Previous work has investigated the development of technoeconomic workflows for the design optimization of pool-type fast reactors that aim to deploy into district energy grids. Initial scoping studies verified that the workflow was capable of capturing design trends throughout a variety of design configurations and problem formulations while remaining sufficiently flexible. In this paper, this methodology is applied to understand how cost functions and technoeconomic constraints can drive optimal reactor design. Specifically, the UPu10Zr-fueled fast reactor model from Part I is adapted to include changes in the fissile content limits, control rod worth limits, control rod drive cost, and assumed fuel form. In the case of constraint relaxation at fixed power (fissile content and control rod worth limits), cost sensitivities of 5% to 10% were uncovered. Multi-objective optimization at varying reactor power levels with individualized control rod drives for each assembly (as opposed to one operational and one safety drive) increased cost by $\$10$ to $\$25$ million and substantially altered the optimal core geometry, favoring geometries with substantially fewer control rod placements relative to baseline optimization. Finally, a multi-objective optimization was performed at varying power levels with the fuel form overhauled to metallic, high-assay low-enriched uranium–based U10Zr with more refined fuel cost models. In the case of uranium fueling, the costs increased by at least $50 million relative to the baseline case. Furthermore, economic fuel zoning and lower reactivity swing cores were recovered. Each case serves to demonstrate the value of applying technoeconomic workflows to initial reactor design scoping studies to better understand the trade-off for a proposed concept between different design options.

Argonne Reactor Computation (ARC) codes↗

Estimating the impacts of natural gas power generation growth on solar electricity development: PJM's evolving resource mix and ramping capability

Abstract Expansion of distributed solar photovoltaic (PV) and natural gas‐fired generation capacity in the United States has put a renewed spotlight on methods and tools for power system planning and grid modernization. This article investigates the impact of increasing natural gas‐fired electricity generation assets on installed distributed solar PV systems in the Pennsylvania–New Jersey–Maryland (PJM) Interconnection in the United States over the period 2008–2018. We developed an empirical dynamic panel data model using the system‐generalized method of moments (system‐GMM) estimation approach. The model accounts for the impact of past and current technical, market and policy changes over time, forecasting errors, and business cycles by controlling for PJM jurisdictions‐level effects and year fixed effects. Using an instrumental variable to control for endogeneity, we concluded that natural gas does not crowd out renewables like solar PV in the PJM capacity market; however, we also found considerable heterogeneity. Such heterogeneity was displayed in the relationship between solar PV systems and electricity prices. More interestingly, we found no evidence suggesting any relationship between distributed solar PV development and nuclear, coal, hydro, or electricity consumption. In addition, considering policy effects of state renewable portfolio standards, net energy metering, differences in the PJM market structure, and other demand and cost‐related factors proved important in assessing their impacts on solar PV generation capacity, including energy storage as a non‐wire alternative policy technique. This article is categorized under: Photovoltaics > Economics and Policy Fossil Fuels > Climate and Environment Energy Systems Economics > Economics and Policy

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Extended-Term Dynamic Simulations with High Penetrations of Photovoltaic Generation.

The uncontrolled intermittent availability of renewable energy sources makes integration of such devices into today's grid a challenge. Thus, it is imperative that dynamic simulation tools used to analyze power system performance are able to support systems with high amounts of photovoltaic (PV) generation. Additionally, simulation durations expanding beyond minutes into hours must be supported. This report aims to identify the path forward for dynamic simulation tools to accom- modate these needs by characterizing the properties of power systems (with high PV penetration), analyzing how these properties affect dynamic simulation software, and offering solutions for po- tential problems. We present a study of fixed time step, explicit numerical integration schemes that may be more suitable for these goals, based on identified requirements for simulating high PV penetration systems. We also present the alternative of variable time step integration. To help determine the characteristics of systems with high PV generation, we performed small signal sta- bility studies and time domain simulations of two representative systems. Along with feedback from stakeholders and vendors, we identify the current gaps in power system modeling including fast and slow dynamics and propose a new simulation framework to improve our ability to model and simulate longer-term dynamics.

14 SOLAR ENERGY↗

Adaptive cold-load pickup considerations in 2-stage microgrid unit commitment for enhancing microgrid resilience

In an extended main grid outage spanning multiple days, load shedding serves as a critical mechanism for islanded microgrids to maintain essential power and energy reserves that are indispensable for fulfilling reliability and resiliency mandates. However, using load shedding for such purposes leads to increasing occurrence of cold load pickup (CLPU) events. Here, this study presents an innovative adaptive CLPU model that introduces a method for determining and incorporating parameters related to CLPU power and energy requirements into a two-stage microgrid unit commitment (MGUC) algorithm. In contrast to the traditional fixed-CLPU-curve approach, this model calculates CLPU duration, power, and energy demands by considering outage durations and ambient temperature variations within the MGUC process. By integrating the adaptive CLPU model into the MGUC problem formulation, it allows for the optimal allocation of energy resources throughout the entire scheduling horizon to fulfill the CLPU requirements when scheduling multiple CLPU events. The performance of the enhanced MGUC algorithm considering CLPU needs is assessed using actual load and photovoltaic (PV) data. Simulation results demonstrate significant improvements in dispatch optimality evaluated by the amount of load served, customer comfort, energy storage operation, and adherence to energy schedules. These enhancements collectively contribute to reliable and resilient microgrid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Active Distribution Systems Resilience by Fully Distributed Self-Healing Strategy

Distributed restoration can exploit smart grid technologies to enhance the resilience of active distribution networks toward a self-healing smart grid. However, the large number of decision variables, especially the binary ones for reconfiguration, bring challenges to developing scalable distributed distribution service restoration (DDSR) strategies. This paper proposes a fully distributed solution procedure based on the alternating direction method of multipliers (ADMM) for mixed-integer programming problems and applies to develop the DDSR framework. The method consists of relax-drive-polish phases, 1) relaxing binary variables, and applying the convex ADMM as a warm start; 2) driving the solutions toward Boolean values through a proximal operator; 3) fixing the obtained binding binary variables and solving the rest of the problem to polish results and achieve a high-quality suboptimal solution. Then, an autonomous clustering strategy and consensus ADMM are integrated with the proposed method to realize the fully distributed cluster-based framework of DDSR. This framework can first determine DER scheduling and switch status for reconfiguration to energize the out-of-service areas from local faults, and then provide the load restoration solution in a distributed manner for total blackouts in large-scale distribution networks. Furthermore, the effectiveness and scalability of the proposed DDSR framework are demonstrated through testing on the IEEE 123-node, IEEE 8500-node, and synthetic 100k-node test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sparsity-Promoting Optimal Wide-Area Control of Power Networks

Inter-area oscillations in bulk power systems are typically poorly controllable by means of local decentralized control. Recent research efforts have been aimed at developing wide-area control strategies that involve communication of remote signals. In conventional wide-area control, the control structure is fixed a priori typically based on modal criteria. In contrast, here we employ the recently-introduced paradigm of sparsity-promoting optimal control to simultaneously identify the optimal control structure and optimize the closed-loop performance. To induce a sparse control architecture, we regularize the standard quadratic performance index with an ℓ 1 -penalty on the feedback matrix. The quadratic objective functions are inspired by the classic slow coherency theory and are aimed at imitating homogeneous networks without inter-area oscillations. We use the New England power grid model to demonstrate that the proposed combination of the sparsity-promoting control design with the slow coherency objectives performs almost as well as the optimal centralized control while only making use of a single wide-area communication link. In addition to this nominal performance, we also demonstrate that our control strategy yields favorable robustness margins and that it can be used to identify a sparse control architecture for control design via alternative means.

25 ENERGY STORAGE↗

Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗

Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events

Danovo Energy Solution's presented its paper named: Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events at the 2026 Georgia Tech Fault & Disturbance Analysis Conference. The full paper can be found at OSTI ID# 3169150 Paper Abstract—Phasor Measurement Units (PMUs) stream time synchronized, high-resolution measurements from the grid, enabling data-driven techniques for event detection and classification. Accurate event classification improves grid reliability and stability. Events can be detected by varying numbers of PMUs and exhibit different durations depending on the event type. This variability challenges standard classifiers that require uniform input sizes. Moreover, multiple events may coincide, which increases classification complexity. Standard classifiers assign each instance to the class with the highest predicted probability, whereas overlapping events may exhibit comparable probabilities across multiple classes. In this study, to handle data size variability, we extract a wide range of time–frequency domain features from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, LightGBM, Support Vector Machine, and Multilayer Perceptron. To account for overlapping events, a probabilistic post-processing step is applied. For a given data instance, if multiple predicted class probabilities exceed 30% and the differences between them are less than 10%, the event is assigned to multiple classes. Experiments using real-world PMU data demonstrate that the Random Forest and XGBoost models achieve the highest accuracy, while the proposed post-processing method yields perfect classification performance on external unseen test sets.

Nematirad, Reza [Danova Energy Solutions]↗

Cloud/climate sensitivity experiments

A study of the relationships between large-scale cloud fields and large scale circulation patterns is presented. The basic tool is a multi-level numerical model comprising conservation equations for temperature, water vapor and cloud water and appropriate parameterizations for evaporation, condensation, precipitation and radiative feedbacks. Incorporating an equation for cloud water in a large-scale model is somewhat novel and allows the formation and advection of clouds to be treated explicitly. The model is run on a two-dimensional, vertical-horizontal grid with constant winds. It is shown that cloud cover increases with decreased eddy vertical velocity, decreased horizontal advection, decreased atmospheric temperature, increased surface temperature, and decreased precipitation efficiency. The cloud field is found to be well correlated with the relative humidity field except at the highest levels. When radiative feedbacks are incorporated and the temperature increased by increasing CO2 content, cloud amounts decrease at upper-levels or equivalently cloud top height falls. This reduces the temperature response, especially at upper levels, compared with an experiment in which cloud cover is fixed.

Roads, J. O.↗

Numerical Study of Outlet Boundary Conditions for Unsteady Turbulent Internal Flows Using the NCC

This paper presents the results of studies on the outlet boundary conditions for turbulent internal flow simulations. Several outlet boundary conditions have been investigated by applying the National Combustion Code (NCC) to the configuration of a LM6000 single injector flame tube. First of all, very large eddy simulations (VLES) have been performed using the partially resolved numerical simulation (PRNS) approach, in which both the nonlinear and linear dynamic subscale models were employed. Secondly, unsteady Reynolds averaged Navier- Stokes (URANS) simulations have also been performed for the same configuration to investigate the effects of different outlet boundary conditions in the context of URANS. Thirdly, the possible role of the initial condition is inspected by using three different initial flow fields for both the PRNS/VLES simulation and the URANS simulation. The same grid is used for all the simulations and the number of mesh element is about 0.5 million. The main purpose of this study is to examine the long-time behavior of the solution as determined by the imposed outlet boundary conditions. For a particular simulation to be considered as successful under the given initial and boundary conditions, the solution must be sustainable in a physically meaningful manner over a sufficiently long period of time. The commonly used outlet boundary condition for steady Reynolds averaged Navier-Stokes (RANS) simulation is a fixed pressure at the outlet with all the other dependent variables being extrapolated from the interior. The results of the present study suggest that this is also workable for the URANS simulation of the LM6000 injector flame tube. However, it does not work for the PRNS/VLES simulation due to the unphysical reflections of the pressure disturbances at the outlet boundary. This undesirable situation can be practically alleviated by applying a simple unsteady convection equation for the pressure disturbances at the outlet boundary. The numerical results presented in this paper suggest that this unsteady convection of pressure disturbances at the outlet works very well for all the unsteady simulations (both PRNS/VLES and URANS) of the LM6000 single injector flame tube.

Liu, Nan-Suey↗

Distributional properties of stochastic shortest paths for smuggled nuclear material

The shortest path problem on a network with fixed weights is a well studied problem with applications to many diverse areas such as transportation and telecommunications. We are particularly interested in the scenario where a nuclear material smuggler tries to succesfully reach herlhis target by identifying the most likely path to the target. The identification of the path relies on reliabilities (weights) associated with each link and node in a multi-modal transportation network. In order to account for the adversary's uncertainty and to perform sensitivity analysis we introduce random reliabilities. We perform some controlled experiments on the grid and present the distributional properties of the resulting stochastic shortest paths.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events

This paper is the basis for a presentation help at the 2026 Georgia Tech Fault & Disturbance Analysis Conference, which can be found at OSTI # 3168287 Paper Abstract—Phasor Measurement Units (PMUs) stream time synchronized, high-resolution measurements from the grid, enabling data-driven techniques for event detection and classification. Accurate event classification improves grid reliability and stability. Events can be detected by varying numbers of PMUs and exhibit different durations depending on the event type. This variability challenges standard classifiers that require uniform input sizes. Moreover, multiple events may coincide, which increases classification complexity. Standard classifiers assign each instance to the class with the highest predicted probability, whereas overlapping events may exhibit comparable probabilities across multiple classes. In this study, to handle data size variability, we extract a wide range of time–frequency domain features from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, LightGBM, Support Vector Machine, and Multilayer Perceptron. To account for overlapping events, a probabilistic post-processing step is applied. For a given data instance, if multiple predicted class probabilities exceed 30% and the differences between them are less than 10%, the event is assigned to multiple classes. Experiments using real-world PMU data demonstrate that the Random Forest and XGBoost models achieve the highest accuracy, while the proposed post-processing method yields perfect classification performance on external unseen test sets.

Nematirad, Reza [Danovo Energy Solutions]↗