Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “feasibility analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Transverse mode analysis for free-space laser beams using Bayesian analysis

Reliable and rapid assessment of the transverse mode quality of a free-space laser beam has a wide range of applications in laser development, research, and utilization. It has become even more important with recent advances in developing orbital angular momentum photon beams across a broad spectral region. In this work, a general modal analysis method for a free-space multimode laser beam has been developed based on Bayesian analysis. After transforming mode decomposition into a linear system problem, a Gaussian probabilistic model is used to find a closed-form solution. The method is found to be robust with the presence of Gaussian noise. Prior knowledge about the mode content can be incorporated into the method to improve the solution for situations when coherent disturbances or contamination are present in the laser beam. This method can be used to analyze the mode content for laser beams in different bases, such as Hermite–Gaussian (HG) modes and Laguerre–Gaussian (LG) modes. Three applications of this method are presented: a detailed modal analysis of the beam image from the incoherent intensity addition of HG modes and two examples of mode decomposition using the complex wavefront from the coherent superposition of HG and LG modes. The feasibility of this method is demonstrated using various simulation results. Based on digital images of a laser beam recorded without complex wavelength-limiting optics, in principle, this method can be used in a wide wavelength range from infrared to ultraviolet, and possibly x ray.

Liu, Peifan (ORCID:0000000273816153)↗

Study of Additive Manufacturing Applications to Geothermal Technologies Final Project Report

This report summarizes work performed to assess the potential for utilizing additive manufacturing (AM) to substantially improve either the availability, performance or cost basis for tools and components that are required for geothermal energy production. A systematic cataloging of geothermal activities, associated technologies, and current manufacturing methods was first undertaken. This included literature reviews as well as interviews with subject matter experts, service companies and OEMs. An industry workshop was held as part of this portion of the project to obtain input and concerns from a broad range of OEMs, service providers and end users. This workshop was also used to gage the current level of AM activity in industry, receptiveness to the use of AM manufactured parts, and any up front concerns that may exist. A summary of the workshop is presented in this report. Representative components and assemblies and their current manufacturing methods were then analyzed by additive manufacturing experts at a company called Senvol to determine the feasibility and required steps for producing parts by additive manufacturing. A step by step description of conventional manufacturing of the parts was also performed to establish a manufacturing baseline for comparison purposes. This analysis also considered and described the benefits of additively manufacturing the parts in terms of specific AM systems, material availability for AM, dimensional requirements and potential economic advantages. Details of the manufacturability assessment were summarized in a report which is included as a chapter in this document. The analysis of the AM subject matter experts was then be used by techno-economic analysts to perform a comparative economic evaluation of the manufacturing of select technologies by AM and conventional approaches. This activity leveraged ORNL expertise and prior experience in other applications. A framework based on assessing cost, volume production considerations, and time to manufacture was created to more easily discern the advantages or disadvantages of additive versus conventional manufacturing methods. The report concludes with a general assessment of the current applicability of AM for geothermal technologies, AM gaps and needs related to typical geothermal hardware, and the potential benefits and impacts of AM to geothermal energy production.

15 GEOTHERMAL ENERGY↗

Study of Storage Requirements and Costs for Shaping Renewables and Nuclear Energy (FY23 Summary Report)

To decarbonize electricity generation primarily by using wind and solar resources, it is likely that additional low (or zero) carbon dioxide (CO 2 ) alternatives will be required for ensuring a reliable electricity supply. This study extends the work and modeling framework that we consolidated in FY 2022, by assessing the zero-CO 2 pathways of a Texas power system in which the availability of variable renewable energy (VRE), nuclear energy, and energy storage types (i.e., battery and thermal energy storage [TES]) are considered the sole resources available for expansion. Using the Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON) frameworks, this study investigates the market of two nuclear energy technologies (i.e., large light-water reactors [LWRs] and LWR-type small modular reactors [SMRs]) under two plausible storage coupling scenarios (i.e., electric coupling and direct thermal coupling). We also explore optimal environments for nuclear energy deployment, and identify key performance characteristics that make nuclear energy economically viable in areas with significant intermittent energy sources. Our analysis encompasses 24 cases. We model the least-cost grid systems, highlight the potential for a coupled LWR-TES approach, and utilize SMRs to achieve deep decarbonization in an affordable, technically feasible manner. We also examine seasonal variations in balancing electricity supply and demand, and account for varying performance, costs, and grid constraints. Overall, the findings of our modeling afford valuable insights for supporting future technology investment decisions in the energy sector.

25 ENERGY STORAGE↗

Feasibility and Qualitative Risk Assessment of Fuel Cell Electric Bus Use for Emergency Backup Power for Airport Applications

Airports rely on robust backup power systems to maintain critical operations during emergencies. This paper investigates the feasibility of using hydrogen fuel cell electric buses (FCEBs) as emergency backup power sources, focusing on their technical specifications, operational challenges, and associated risks. Using Portland International Airport as a case study, the analysis evaluates the power output and hydrogen consumption of New Flyer’s 40’ Xcelsior Charge fuel cell buses, to provide power for key airport systems. Additionally, the paper explores the design and layout of how FCEBs can be connected to airport facilities, and addresses safety considerations, hydrogen supply logistics, and electrical compatibility. While FCEBs present significant advantages in terms of sustainability and resilience, their implementation requires careful planning, infrastructure investment, and adherence to safety standards. This research provides actionable insights for airport stakeholders seeking to transition to hydrogen-based backup power system.

08 HYDROGEN↗

UN-SiC TRISO Post Irradiation Examination Developmental Work

As part of efforts to strengthen INL?s post irradiation analysis capabilities with non-Advanced Gas Reactor (AGR) tristructural isotropic (TRISO) fuels, two developmental activities were conducted. The first activity was to determine how best to analyze uranium nitride TRISO fuel kernels using electron probe microanalysis, while the second activity focused on developing a method to deconsolidate TRISO fuel particles that have been encased in a silicon carbide matrix. Because these two activities were unrelated, they have been presented separately in this report. Initial EPMA analyses showed nitrogen contents that far exceeded the concentration expected for UN--a line compound. Further examination showed that current literature values for the mass absorption coefficient (MAC) for the N ka X-ray absorbed by U ranged from approximately 1600 to 9500, with most values tending toward 9500. Measuring UN with five different progressively increasing accelerating voltages followed by using the modeling program xMAC suggests the actual MAC is approximately 2115. Additional MAC modifications were required to produce reasonable analytical results. Because of the inaccuracies of necessary MAC coefficients, UN analysis via scanning electron microscopy (SEM) is likely to produce inaccurate results. This is because SEM software does not typically allow the user to alter MACs. Tests have been performed to examine the feasibility of an electrochemical technique to liberate irradiated TRISO fuel from a SiC matrix without damaging the outer pyrolytic carbon layer of the fuel particle. The method is performed by electrochemically exposing the SiC to magnesium metal forming Mg2Si and C. Following exposure, the small SiC samples showed slight mass increases with no evidence of conversion to Mg2Si and C nor obvious degradation of the SiC samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid measurement of soluble xylo-oligomers using near-infrared spectroscopy (NIRS) and multivariate statistics: calibration model development and practical approaches to model optimization

Rapid monitoring of biomass conversion processes using techniques such as near-infrared (NIR) spectroscopy can be substantially quicker and less labor-, resource-, and energy-intensive than conventional measurement techniques such as gas or liquid chromatography (GC or LC) due to the lack of solvents and preparation methods, as well as removing the need to transfer samples to an external lab for analytical evaluation. The purpose of this study was to determine the feasibility of rapid monitoring of a biomass conversion process using NIR spectroscopy combined with multivariate statistical modeling, and to examine the impact of (1) subsetting the samples in the original dataset by process location and (2) reducing the spectral range used in the calibration model on model performance. We develop multivariate calibration models for the concentrations of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids at multiple points in a biomass conversion process which produces and then purifies XOS compounds from sugar cane bagasse. A single model using samples from multiple locations in the process stream showed acceptable performance as measured by standard statistical measures. However, compared to the single model, we show that separate models built by segregating the calibration samples according to process location show improved performance. We also show that combining an understanding of the sample spectra with simple multivariate analysis tools can result in a calibration model with a substantially smaller spectral range that provides essentially equal performance to the full-range model. We demonstrate that real-time monitoring of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids concentration at multiple points in a process stream using NIR spectroscopy coupled with multivariate statistics is feasible. Segregation of sample populations by process location improves model performance. Models using a reduced spectral range containing the most relevant spectral signatures show very similar performance to the full-range model, reinforcing the importance of performing robust exploratory data analysis before beginning multivariate modeling.

09 BIOMASS FUELS↗

A techno-economic framework for comparing conventionally and additively manufactured parts for geothermal applications

Geothermal reservoir characterization, construction, and operations are technology-intensive activities that contribute significantly to the cost of delivering renewable electricity. The technologies involved, such as downhole tools and drilling equipment, are similar to those used in oil and gas exploration and production must often be adapted for use in the corrosive, high-temperature geothermal reservoir environment. Low production volume of geothermal tools presents a major challenge in meeting the industry's technology needs. Production of specialized tools for geothermal subsurface applications is often cost-prohibitive. Reduced inventory of subsurface well construction, characterization, and production tools causes geothermal reservoir development efficiency and sophistication to lag behind that of the oil and gas industry. Advances in additive manufacturing provide opportunities to advance geothermal technology while reducing lead time and costs associated with production of low-volume, complex parts. Additionally, this paper performs an initial techno-economic analysis comparing the cost of conventional production techniques and additive manufacturing for geothermal downhole applications. An analysis of representative downhole tools is used to create a framework for estimating fabrication costs of subtractive and additive techniques, including post-print machining required to meet final tolerances. The framework is used to explore several manufacturing scenarios and identify the dominant factors driving manufacturing time and cost. The current feasibility of additive manufacturing for geothermal downhole tool applications is assessed and issues for future development to better meet the needs of the geothermal industry are identified.

36 MATERIALS SCIENCE↗

Mapathons versus automated feature extraction: a comparative analysis for strengthening immunization microplanning

Background: Social instability and logistical factors like the displacement of vulnerable populations, the difficulty of accessing these populations, and the lack of geographic information for hard-to-reach areas continue to serve as barriers to global essential immunizations (EI). Microplanning, a population-based, healthcare intervention planning method has begun to leverage geographic information system (GIS) technology and geospatial methods to improve the remote identification and mapping of vulnerable populations to ensure inclusion in outreach and immunization services, when feasible. We compare two methods of accomplishing a remote inventory of building locations to assess their accuracy and similarity to currently employed microplan line-lists in the study area. Methods: The outputs of a crowd-sourced digitization effort, or mapathon, were compared to those of a machine-learning algorithm for digitization, referred to as automatic feature extraction (AFE). The following accuracy assessments were employed to determine the performance of each feature generation method: (1) an agreement analysis of the two methods assessed the occurrence of matches across the two outputs, where agreements were labeled as “befriended” and disagreements as “lonely”; (2) true and false positive percentages of each method were calculated in comparison to satellite imagery; (3) counts of features generated from both the mapathon and AFE were statistically compared to the number of features listed in the microplan line-list for the study area; and (4) population estimates for both feature generation method were determined for every structure identified assuming a total of three households per compound, with each household averaging two adults and 5 children. Results: The mapathon and AFE outputs detected 92,713 and 53,150 features, respectively. A higher proportion (30%) of AFE features were befriended compared with befriended mapathon points (28%). The AFE had a higher true positive rate (90.5%) of identifying structures than the mapathon (84.5%). The difference in the average number of features identified per area between the microplan and mapathon points was larger (t = 3.56) than the microplan and AFE (t = -2.09) (alpha = 0.05). Conclusions: Our findings indicate AFE outputs had higher agreement (i.e., befriended), slightly higher likelihood of correctly identifying a structure, and were more similar to the local microplan line-lists than the mapathon outputs. These findings suggest AFE may be more accurate for identifying structures in high-resolution satellite imagery than mapathons. However, they both had their advantages and the ideal method would utilize both methods in tandem.

59 BASIC BIOLOGICAL SCIENCES↗

Autonomous monitoring of algal biomass: Success stories and lessons learned from long-term field deployment

Autonomous, high-frequency monitoring of outdoor algal ponds is needed to quantify biomass productivity and detect culture decline in environments prone to contamination, grazers, and variable operating conditions. We report successes and lessons learned in translating a laboratory spectroradiometric monitoring approach to a multi-year autonomous field deployment at the Arizona Center for Algae Technology and Innovation (AzCATI). The system measures spectrally resolved pond reflectance by ratioing upwelling radiance from each raceway to simultaneous downwelling sky irradiance using fiber-coupled spectrometers. A physics-based reflectance model (ASHARP) is fit to each spectrum pair to estimate optical parameters, including a biomass-proxy coefficient (C a ) which enables near-real-time tracking of biomass accumulation and culture state at 2–5 min intervals. From May 2022 through September 2025 the platform operated continuously while scaling from two to six raceway ponds. Several strains of algae were monitored successfully, including the high productivity Tetraselmis striata and Picochlorum celeri. Transitioning data acquisition from a Windows laptop to a Raspberry Pi improved uptime from 57% (2022) to ~89% (2024–2025) and enabled routine real-time analysis. Further, we converted relative biomass estimates to absolute ash-free dry weight (AFDW) using experimentally-derived calibrations, providing field-relevant biomass predictions with conservative confidence bounds. These results demonstrate the feasibility of long-term, autonomous optical monitoring for well-mixed open-raceway algal cultivation and provide practical guidance for reliable field operation and scaling.

Katinas, Christopher Michael [Sandia National Labo↗

Thermal Stability of Au Rhombic Dodecahedral Nanocrystals Can Be Greatly Enhanced by Coating Their Surface with an Ultrathin Shell of Pt

Rhombic dodecahedral nanocrystals have been considered particularly difficult to synthesize because they are enclosed by {110}, a low-index facet with the greatest surface energy. Recently, we demonstrated the use of seed-mediated growth for the facile and robust synthesis of Au rhombic dodecahedral nanocrystals (AuRD). While the unique shape and surface structure of AuRD are desirable for potential applications in plasmonics and catalysis, respectively, their high surface energy makes them highly susceptible to thermal degradation. Here we demonstrate that it is feasible to greatly improve the thermal stability with some sacrifice to the plasmonic properties of the original AuRD by coating their surface with an ultrathin shell made of Pt. Our in situ electron microscopy analysis indicates that the ultrathin Pt coating can increase the thermal stability from 60 up to 450 °C, a trend that is also supported by the results from a computational study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How Accurate Are Simulations and Experiments for the Lattice Energies of Molecular Crystals?

Molecular crystals play a central role in a wide range of scientific fields, including pharmaceuticals and organic semiconductor devices. However, they are challenging systems to model accurately with computational approaches because of a delicate interplay of intermolecular interactions such as hydrogen bonding and Van der Waals dispersion forces. Here, by exploiting recent algorithmic developments, we report the first set of diffusion Monte Carlo lattice energies for all 23 molecular crystals in the popular and widely used X23 dataset. Comparisons with previous state-of-the-art lattice energy predictions (on a subset of the dataset) and a careful analysis of experimental sublimation enthalpies reveals that high-accuracy computational methods are now at least as reliable as (computationally derived) experiments for the lattice energies of molecular crystals. Overall, this work demonstrates the feasibility of high-level explicitly correlated electronic structure methods for broad benchmarking studies in complex condensed phase systems, and signposts a route towards closer agreement between experiment and simulation. Published by the American Physical Society 2024

Physics↗

The Los Angeles 100% Renewable Energy Study (LA100): Executive Summary

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download.

100% renewable↗

The Los Angeles 100% Renewable Energy Study (LA100): Chapter 1. Introduction

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download. This chapter introduces the study.

100% Renewable↗

The Los Angeles 100% Renewable Energy Study (LA100): Chapter 2. Study Approach

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download. This chapter describes the LA100 study approach, including the modeling framework and scenarios.

100% Renewable↗

The Los Angeles 100% Renewable Energy Study (LA100): Chapter 3. Electricity Demand Projections

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download. This chapter explores how electricity is consumed by customers now, how that might change through 2045, and potential opportunities to better align electricity demand and supply.

100% Renewable↗

The Los Angeles 100% Renewable Energy Study (LA100): Chapter 4. Customer-Adopted Rooftop Solar and Storage

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download. This chapter explores the technical and economic potential for rooftop solar in LA, and how much solar and storage might be adopted by customers.

100% Renewable↗

The Los Angeles 100% Renewable Energy Study (LA100): Chapter 5. Utility Options for Local Solar and Storage

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download. This chapter identifies and ranks locations for utility-scale solar (ground-mount, parking canopy, and floating) and storage, and associated costs for integrating these assets into the distribution system.

100% Renewable↗

The Los Angeles 100% Renewable Energy Study (LA100): Chapter 6. Renewable Energy Investments and Operations

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download. This chapter explores pathways to 100% renewable electricity, describing the types of generation resources added, their costs, and how the systems maintain sufficient resources to serve customer demand, including resource adequacy and transmission reliability.

100% Renewable↗