Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Asperity generation and its relationship to seismicity on a planar fault: A laboratory simulation

Earthquake faults, and all frictional surfaces, establish contact through asperities. A detailed knowledge of how asperities form will enable a better understanding of the manner in which they communicate during foreshock failure sequences that are observed, leading to the larger main shock. We present results of experiments where a pressure sensitive film was used to map, size and measure the magnitudes of the normal stresses at asperities along a seismogenic section of a laboratory simulated fault. We measured seismicity acoustically and foreshocks were found to be the result of localized asperity failure during the nucleation phase of gross fault rupture. Since surface roughness plays an important role in how asperities are formed, two Hurst exponents were measured to characterize a highly worn interface using roughness profiles: (i) long wavelength estimates (H ~ 0.45) and (ii) short wavelength estimates (H ~ 0.8-1.2). The short wavelength roughness estimates were computed at the scale of single asperity junction points. Macroscopically, the number of asperities and real contact area increased with additional application of normal force while the mean normal stress remained constant. The ratio of real to nominal contact area was low - ranging from 0.02 < A r /A 0 < 0.05-predicting that the asperities should be elastically independent of each other. Results from the pressure sensitive film showed that asperities were closely spaced and could not be treated as mechanically independent. Larger asperities carried both higher levels of average normal stress and higher levels of normal stress heterogeneity than smaller ones. Using linear stability theorem, the critical slip distance on foreshocking asperities was estimated to be d 0 ~ 0.65-3 μm. The critical slip distance d 0 was ~1.8-11.5 per cent of the premonitory slip needed to initiate gross fault rupture of the interface (20-40 μm) and the overall slip necessary to initiate gross fault rupture was on the order of the average asperity diameter (52 μm). In conclusion, foreshocks may be due to a change in the critical slip distance, at localized sections of the fault, caused by the two distinct roughness profiles measured at short and long length scales.

58 GEOSCIENCES↗

Distributed Ledger Technology for Fault Tolerant Distribution Grid Operations

This paper explores the potential of distributed ledger technology (DLT) to improve fault-tolerant grid operations by leveraging its core features as an immutable, decentralized ledger, a distributed, consensus-based agreement process, and a distributed state-replication engine. Distribution power systems deliver electricity to millions of customers; however, they are susceptible to various threats that can result in customer interruptions. These include faults caused by adverse weather conditions, natural disasters, vegetation growth, equipment failure, and malicious attacks. To minimize the effects of these faults, fault-handling approaches rely on network knowledge to isolate affected areas and reconnect unaffected areas, reducing the number of affected customers while maintaining safety. Here, we present a trusted data-sharing architecture that enables independent, distributed actors to reconstruct the pre-fault system state by enabling distributed resources to make appropriate decisions with limited network/system information. Although the process requires some data sharing between switch-delimited areas, the approach limits the amount of private information shared, preserving customers' privacy and business-sensitive information. We include three use cases that form a foundation for third parties to develop functional solutions that can eventually be deployed in the field. The gross error detection method used within switch-delimited areas can identify sensor errors and accurately detect circuit breaker states. The evaluation of possible reconnection while preserving data ownership resulted in a voltage magnitude difference smaller than 0.001% from the OpenDSS power flow solution that has full system knowledge, which is below the expected power flow tolerance. The approach offers a promising opportunity for improving fault-tolerant distribution grid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detecting and Diagnosing Incipient Building Faults Using Uncertainty Information from Deep Neural Networks

Early detection of incipient faults is of significant importance to reducing maintenance costs, saving energy, and enhancing occupant comfort in buildings. Popular supervised learning models such as deep neural networks are considered promising due to their ability to directly learn from labeled fault data; however, it is known that the performance of supervised learning approaches highly relies on the availability and quality of labeled training data. In Fault Detection and Diagnosis (FDD) applications, the lack of labeled incipient fault data has posed a major challenge to applying these supervised learning techniques to commercial buildings. To address this concern, this paper proposes using Monte Carlo dropout (MC-dropout) to enhance the supervised learning pipeline, so that the resulting neural network is able to detect and diagnose unseen incipient fault examples. We also examine the proposed MC-dropout method on the RP-1043 dataset to demonstrate its effectiveness in indicating the most likely incipient fault types.

42 ENGINEERING↗

Fault-tolerant dynamic task graph scheduling

In this paper, we present an approach to fault tolerant execution of dynamic task graphs scheduled using work stealing. In particular, we focus on selective and localized recovery of tasks in the presence of soft faults. We elicit from the user the basic task graph structure in terms of successor and predecessor relationships. The work stealing-based algorithm to schedule such a task graph is augmented to enable recovery when the data and meta-data associated with a task get corrupted. We use this redundancy, and the knowledge of the task graph structure, to selectively recover from faults with low space and time overheads. We show that the fault tolerant design retains the essential properties of the underlying work stealing-based task scheduling algorithm, and that the fault tolerant execution is asymptotically optimal when task re-execution is taken into account. Experimental evaluation demonstrates the low cost of recovery under various fault scenarios.

fault tolerance↗

Validation techniques for fault emulation of SRAM-based FPGAs

A variety of fault emulation systems have been created to study the effect of single-event effects (SEEs) in static random access memory (SRAM) based field-programmable gate arrays (FPGAs). These systems are useful for augmenting radiation-hardness assurance (RHA) methodologies for verifying the effectiveness for mitigation techniques; understanding error signatures and failure modes in FPGAs; and failure rate estimation. For radiation effects researchers, it is important that these systems properly emulate how SEEs manifest in FPGAs. If the fault emulation systems does not mimic the radiation environment, the system will generate erroneous data and incorrect predictions of behavior of the FPGA in a radiation environment. Validation determines whether the emulated faults are reasonable analogs to the radiation-induced faults. In this study we present methods for validating fault emulation systems and provide several examples of validated FPGA fault emulation systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Towards Automated/Semiautomated Extraction of Faults from Lidar Data

The Pajarito fault system is a complex zone of deformation and a seismically active region nestled within the Rio Grande rift in north-central New Mexico. Numerous laterally discontinuous faults and associated folds and fractures interact in a manner that has important implications for seismic hazards and risk mitigation. Previous efforts have established a foundation for the location of lineaments and structures in the Pajarito fault system; however, ensuring the completeness of the current lineament mapping is required for identifying areas for field validation, evaluating the potential for future seismic activity, and better understanding fault interaction. Assistance with this fault-mapping task via automated or semiautomated techniques as applied to lidar data over a large area of interest is highly desirable. A proof-of-concept processing flow which transforms lidar point-cloud data into a raster of surficial fault candidates is described and illustrated herein. We report these initial results hold great promise toward achieving our ultimate goal.

58 GEOSCIENCES↗

Utah FORGE: Fault Reactivation Through Fluid Injection Induced Seismicity Laboratory Experiments

Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite. All experiments are conducted at ambient temperature and follow a similar protocol: (i) application of confining stresses (3MPa) on the fault fully saturated with DI water, (ii) shear-mobilization through the increase of axial loading at a constant displacement rate until a post-peak steady-state condition is reached, (iii) reduction of axial loading and related shear stress to a prescribed fraction of the peak steady-state frictional strength (typically 60% to 90%, representing intermediate to high magnitudes) and (iv), fault reactivation triggered by a stepwise increase of pore pressure on the fault in 0.1 MPa increments held constant for 1-5 minutes. Mechanical data from three ISCO pumps connected to a Temco pressure vessel measure axial, confining, and fault-related parameters, including fluid pressure (kPa), fluid flow rate (mL/min), and axial displacement (mm). See included code for initial data analysis and visualization for select experiments. Resource names represent experiment numbers found in the "Read Me" file, which describes each experimental setup and parameters.

15 GEOTHERMAL ENERGY↗

Is the Multigrid Method Fault Tolerant? The Two-Grid Case

The predicted reduced resiliency of next-generation high performance computers means that it will become necessary to take into account the effects of randomly occurring faults on numerical methods. Further, in the event of a hard fault occurring, a decision has to be made as to what remedial action should be taken in order to resume the execution of the algorithm. The action that is chosen can have a dramatic effect on the performance and characteristics of the scheme. Ideally, the resulting algorithm should be subjected to the same kind of mathematical analysis that was applied to the original, deterministic variant. The purpose of this work is to provide an analysis of the behaviour of the multigrid algorithm in the presence of faults. Multigrid is arguably the method of choice for the solution of large-scale linear algebra problems arising from discretization of partial differential equations and it is of considerable importance to anticipate its behaviour on an exascale machine. The analysis of resilience of algorithms is in its infancy and the current work is perhaps the first to provide a mathematical model for faults and analyse the behaviour of a state-of-the-art algorithm under the model. It is shown that the Two Grid Method fails to be resilient to faults. Attention is then turned to identifying the minimal necessary remedial action required to restore the rate of convergence to that enjoyed by the ideal fault-free method.

97 MATHEMATICS AND COMPUTING↗

Fault Mitigation Schemes for Future Spaceflight Multicore Processors

Future planetary exploration missions demand significant advances in on-board computing capabilities over current avionics architectures based on a single-core processing element. The state-of-the-art multi-core processor provides much promise in meeting such challenges while introducing new fault tolerance problems when applied to space missions. Software-based schemes are being presented in this paper that can achieve system-level fault mitigation beyond that provided by radiation-hard-by-design (RHBD). For mission and time critical applications such as the Terrain Relative Navigation (TRN) for planetary or small body navigation, and landing, a range of fault tolerance methods can be adapted by the application. The software methods being investigated include Error Correction Code (ECC) for data packet routing between cores, virtual network routing, Triple Modular Redundancy (TMR), and Algorithm-Based Fault Tolerance (ABFT). A robust fault tolerance framework that provides fail-operational behavior under hard real-time constraints and graceful degradation will be demonstrated using TRN executing on a commercial Tilera(R) processor with simulated fault injections.

software based↗

Analyzing and Predicting Effort Associated with Finding and Fixing Software Faults

Context: Software developers spend a significant amount of time fixing faults. However, not many papers have addressed the actual effort needed to fix software faults. Objective: The objective of this paper is twofold: (1) analysis of the effort needed to fix software faults and how it was affected by several factors and (2) prediction of the level of fix implementation effort based on the information provided in software change requests. Method: The work is based on data related to 1200 failures, extracted from the change tracking system of a large NASA mission. The analysis includes descriptive and inferential statistics. Predictions are made using three supervised machine learning algorithms and three sampling techniques aimed at addressing the imbalanced data problem. Results: Our results show that (1) 83% of the total fix implementation effort was associated with only 20% of failures. (2) Both safety critical failures and post-release failures required three times more effort to fix compared to non-critical and pre-release counterparts, respectively. (3) Failures with fixes spread across multiple components or across multiple types of software artifacts required more effort. The spread across artifacts was more costly than spread across components. (4) Surprisingly, some types of faults associated with later life-cycle activities did not require significant effort. (5) The level of fix implementation effort was predicted with 73% overall accuracy using the original, imbalanced data. Using oversampling techniques improved the overall accuracy up to 77%. More importantly, oversampling significantly improved the prediction of the high level effort, from 31% to around 85%. Conclusions: This paper shows the importance of tying software failures to changes made to fix all associated faults, in one or more software components and/or in one or more software artifacts, and the benefit of studying how the spread of faults and other factors affect the fix implementation effort.

software fix implementation effort↗

Hybrid Model-Based and Data-Driven Fault Detection and Diagnostics for Commercial Buildings: Preprint

Commercial buildings often experience faults that produce undesirable behavior in building systems. Building faults waste energy, decrease occupants' comfort, and increase operating costs. Automated fault detection and diagnosis (FDD) tools for buildings help building owners discover and identify the root causes of faults in building systems, equipment, and controls. Proper implementation of FDD has the potential to simultaneously improve comfort, reduce energy use, and narrow the gap between actual and optimal building performance. However, conventional rule-based FDD requires expensive instrumentation and valuable engineering labor, which limit deployment opportunities. This paper presents a hybrid, automated FDD approach that combines building energy models and statistical learning tools to detect and diagnose faults noninvasively, using minimal sensors, with little customization. We compare and contrast the performance of several hybrid FDD algorithms for a small security building. Our results indicate that the algorithms can detect and diagnose several common faults, but more work is required to reduce false positive rates and improve diagnosis accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Model-Based and Data-Driven Fault Detection and Diagnostics for Commercial Buildings

Commercial buildings often experience faults that produce undesirable behavior in building systems. Building faults waste energy, decrease occupants' comfort, and increase operating costs. Automated fault detection and diagnosis (FDD) tools for buildings help building owners discover and identify the root causes of faults in building systems, equipment, and controls. Proper implementation of FDD has the potential to simultaneously improve comfort, reduce energy use, and narrow the gap between actual and optimal building performance. However, conventional rule-based FDD requires expensive instrumentation and valuable engineering labor, which limit deployment opportunities. This paper presents a hybrid, automated FDD approach that combines building energy models and statistical learning tools to detect and diagnose faults noninvasively, using minimal sensors, with little customization. We compare and contrast the performance of several hybrid FDD algorithms for a small security building. Our results indicate that the algorithms can detect and diagnose several common faults, but more work is required to reduce false positive rates and improve diagnosis accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization NPIC presentation

The nuclear industry is beginning to see reactors shut down—even after their operating licenses have been extended—because they are not economically competitive with other energy sources. These early closures happen primarily due to economic reasons, despite excellent safety records. Therefore, it is imperative to reduce costs in order to prevent these early closures. One of the contributors to these economic reasons is the large operations and maintenance costs. This paper showcases recent research on advanced fault diagnostics techniques and preventative maintenance optimization (PMO) for reducing NPP maintenance costs. Specifically, it focuses on the feedwater and condensate system (FWCS) for both pressurized- and boiling-water reactor (BWR) systems. The computerized maintenance management system (CMMS), which contains the plant’s digital record of all corrective maintenance (CM) and preventative maintenance (PM) work orders, provided the ground truth for locating potential faults and labeling the process data as either healthy or faulted. Various feature extraction techniques were used to further differentiate the faulted data from the healthy data. Through a cross-validation procedure, support vectors machines were used to label other test sets of process data as either healthy or faulted. With relatively few faults identified in the BWR system, the potential for PMO opens up, since an unnecessary amount of PM leads to inflated maintenance costs. The steps for PMO are summarized, from component health determinations to recommendations for action. An example of PMO assessment is presented for condensate pumps, condensate booster pumps, and the respective motors that drive them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.

fault ride-through↗

Late Holocene Structural Style and Seismicity of Highly Transpressional Faults in Southern Haiti

The devastating 2010 Haiti earthquake ( M w 7.0) was caused by rupture of the Léogâne, blind, thrust fault located 5 km north of the 1,200-km-long, left-lateral, Enriquillo-Plantain Garden fault zone (EPGFZ). Unexpectedly, the EPGFZ remained largely quiescent or slightly reactivated during the 2010 earthquake. Nevertheless, the EPGFZ still formed a major, crustal boundary between a coseismically uplifted lowland north of the EPGFZ and a subsided area in the highlands south of the fault. Here we use high-resolution sonar data from two Haitian Lakes that straddle the EPGFZ to demonstrate the presence of a 10- to 15-km-wide, 120-km-long, late Holocene fold-thrust belt which deforms clastic, lowland basins along the northern edge of the EPGFZ. In the eastern part of the study area, sonar results from Lake Azuey show that the linear trace of the EPGFZ cutting the Holocene lake bed is more deeply buried and less active than the adjacent, newly discovered, northwest striking, northeast dipping Jimani thrust fault that is part of the adjacent, transpressional belt of en echelon thrusts and folds. This structural relationship between a less active EPGFZ and more recently active, transpression-related Jimani thrust is remarkably similar to the 2010 epicentral area 70 km to the west between the less active EPGFZ and seismogenic, northeast-dipping, Léogâne thrust during the 2010 Haiti earthquake. In this complex transpressional zone, we propose that coseismic deformation alternates at recurrence intervals of centuries between oblique, transpression-related structures (Léogâne, Jimani, and Trois Baies thrusts) and the main strike-slip, plate boundary fault zone (EPGFZ).

2010 Haiti earthquake↗

Fault geometry inversion and slip distribution of the 2010 M w 7.2 El Mayor-Cucapah earthquake from geodetic data

The 4 April 2010 M w 7.2 El Mayor-Cucapah (EMC) earthquake in Baja, California, and Sonora, Mexico, had primarily right-lateral strike-slip motion and a minor normal-slip component. The surface rupture extended about 120 km in a NW-SE direction, west of the Cerro Prieto fault. We use geodetic measurements including near- to far-field GPS, interferometric synthetic aperture radar (InSAR), and subpixel offset measurements of radar and optical images to characterize the fault slip during the EMC event. We use dislocation inversion methods and determine an optimal nine-segment fault geometry, as well as a subfault slip distribution from the geodetic measurements. With systematic perturbation of the fault dip angles, randomly removing one geodetic data constraint, or different data combinations, we are able to explore the robustness of the inferred slip distribution along fault strike and depth. The model fitting residuals imply contributions of early postseismic deformation to the InSAR measurements as well as lateral heterogeneity in the crustal elastic structure between the Peninsular Ranges and the Salton Trough. We also find that with incorporation of near-field geodetic data and finer fault patch size, the shallow slip deficit is reduced in the EMC event by reductions in the level of smoothing. Finally, these results show that the outcomes of coseismic inversions can vary greatly depending on model parameterization and methodology.

58 GEOSCIENCES↗

On the distribution of stacking faults at dissociated medium-angle grain boundaries: Crystallographic geometry and metastability

Grain boundaries in FCC metals with low stacking-fault energy can form in dissociated configurations of stacking faults. Perhaps the most studied example is 9R stacking at boundaries near Σ3{112}, where the distribution of stacking faults is related to the emission of Shockley partial dislocations. Here, we combine atomic-resolution electron microscopy, atomistic simulations, and dislocation theory to demonstrate that boundaries vicinal to Σ33a support the stabilization of dissociated 9R stacking within a narrow range of inclinations. This boundary is interesting since its misorientation (20.05°) lies in the medium-angle regime, just past the upper misorientation limit for low-angle boundaries, motivating questions for how best to describe it in terms of dislocations. Our HAADF-STEM observations of thin film bicrystals, supported by atomistic modeling, reveal that this inclination dependence arises from specific geometric constraints on the arrangement of Shockley partial dislocations at the interface. Quantification of stacking-fault distributions across multiple boundaries indicates that the density and spacing of faults closely follow the ideal 9R motif, with subtle variations reflecting the complex energy landscape of these boundaries. Through energetic analysis, we establish the presence of competing metastable states enabled by variations in stacking sequences, emphasizing the significant role of crystallographic geometry. We generalize our analysis as a function of misorientation, showing how 9R at the Σ33a boundary is related to previous observations and calculations of HCP at a 29.7° boundary. This study provides a crystallographically grounded framework connecting dislocation structures, stacking-fault distributions, and metastability at grain boundaries in FCC metals.

Atomistic modeling↗

Simulations of carbon dioxide push-pull into a conjugate fault system modeled after Dixie Valley—Sensitivity analysis of significant parameters and uncertainty prediction by data-worth analysis

Characterizing the faults and fractures that provide flow pathways for efficient geothermal energy production is critical for design of sustainable geothermal energy production. Both natural faults and stimulated fractures in enhanced geothermal systems (EGS) are difficult to image and map by seismic methods because hot brine filling the fractures and faults does not create a strong seismic property contrast relative to surrounding rock. We investigate here the technical feasibility of using supercritical CO 2 (scCO 2 ) injection into faults in a single-well push-pull scenario to characterize the hydraulic properties of the fault zone by emplacing scCO 2 that can serve as a contrast fluid for seismic monitoring. We develop a conceptual and numerical reservoir model of two intersecting faults based on the Dixie Valley geothermal system in Nevada, USA.

15 GEOTHERMAL ENERGY↗