Analysis of Tank 38H (HTF-38-22-91, -92) and Tank 43H (HTF-43-22-93, -94) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased slightly from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains more sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank. The Tank 43H surface and sub-surface samples are similar in composition to the previous samples. The similar solution compositions measured in the Tank 43H surface and sub-surface samples indicate a minimal stratification within the tank. The total uranium and plutonium in the current Tank 38H surface sample remains similar to the previous analysis. The Tank 38H sub-surface sample shows an increase in uranium and plutonium concentrations compared to the previous sample likely because of an increase in sludge solids in the current sample. The total uranium concentration in the two Tank 43H samples is essentially unchanged from previous sample results. The plutonium concentration in the Tank 43H surface sample is similar to the previous sample results while the plutonium in the Tank 43H sub-surface sample increased relative to the previous analysis. The sum of the major cations versus the sum of the major anions shows a difference of <10% for both samples from Tank 38H and for both samples from Tank 43H providing an indication of good data quality for the non-radioactive analytes in the samples. The silicon concentrations measured in the Tank 38H sub-surface sample increased compared with the previous sample results likely due to the presence of more sludge solids in the current sample. The Tank 38H surface sample silicon concentrations is similar to the previous sample results. The Tank 43H surface and sub-surface sample silicon concentrations both increased compared to the previous sample results. The samples analyzed from Tanks 38H and 43H show silicon concentrations ranging from 61.5 to 97.3 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38h (HTF-38-23-19, -20) and Tank 43H (HTF-43-23-21, -22) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample decreased significantly from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Thank 38H sub-surface sample contains visible sludge solids similar to the previous sample, i.e., less than 1%, based on visual appearance. The significant differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species between these two locations within the tank. Savannah River Mission Completion personnel indicate that ~ 150,000 gallons of Tank 22 supernate were received in Tank 38H since its last analysis during which time the 2H evaporator was not operated, so the observed stratification is expected. The Tank 43H surface and sub-surface samples are similar in composition to the previous samples. The similar solution compositions measured in the Tank 43H surface and sub-surface samples indicate a minimal stratification within the tank. The total uranium and plutonium in the current Tank 38H surface sample remains similar to the previous analysis. The Tank 38H sub-surface sample shows an increase in uranium and plutonium concentrations compared to the previous sample likely because of an increase in sludge solids in the current sample. The total uranium concentration in the Tank 43H surface sample is similar to the previous sample results while the plutonium in the Tank 43H sub-surface sample increased relative to the previous analysis. The sum of the major cations versus the sum of the major anions shows a difference of <10% for both samples from Tank 38H sub-surface sample (174 mg/L) increased compared with the previous sample. The Tank 38H surface sample silicon concentrations (27.5 mg/L) is one-half of the previous sample results. The Tank 43H surface sample silicon concentrations compared to the previous sample results indicate Si in the concentration range of 60 to 83 mg/L. Thus, these current samples analyzed from Tanks 38H and 43H show overall silicon concentrations ranging from 27.5 to 174 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enrichment of H2 to CO2 ratio using formic acid as a hydrogen carrier - CRADA 581 (Abstract)

The collaboration between PNNL and OCOchem will investigate approaches to enhance the hydrogen (H2) content from a stream of H2 and carbon dioxide (CO2) gases produced in the catalytic decomposition of aqueous formic acid (FA85). OCOchem uses an electrochemical process to generate FA85 from captured CO2 using electricity from renewable resources. The FA85 is a liquid organic hydrogen carrier (LOHC) that provides the opportunity to transport and store hydrogen, in liquid form, at volumetric densities significantly greater than compressed H2 gas, i.e., 50 grams H2/liter FA. PNNL has developed and tested catalytic reactors to release H2 from LOHCs like FA and aqueous formate salts (FS). The H2 released from the LOHC can be oxidized in a proton-exchange membrane fuel cell (PEM-FC) to generate electricity with water as the only by-product. The purpose of the proposed project is to increase the purity of the hydrogen released from the LOHC to enhance the operation efficiency of the PEM FC. The PEM FC in combination with the LOHC provides an approach to demonstrate a portable generator that utilizes hydrogen as the energy carrier instead of conventional diesel generator. The ‘hydrogen generator’ can be used to supply emergency backup power and significantly reduce CO2 emissions relative to a diesel generator.

30 DIRECT ENERGY CONVERSION↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site

Alternate Actinide Calibration is beneficial for calibration using lower activity standards • ICP-MS and ICP-OES are valid complementary methods for U analysis • Recently procured Agilent 8900 ICP-QQQ-MS in radiological buffer area –installation in progress • Helium (kinetic energy discrimination) can be used for reducing polyatomic interferences • Installing hydrogen and oxygen (reaction gases) on 8900 ICP-MS systems to improve LODs of several challenging analytes

Jones, Mark A.↗

Preliminary Design of Critical Experiments Involving Commercially Available B 4 C Neutron Absorber Plates with Low-Enriched UO 2 Fuel [Slides]

Conclusions of this presentation conclude that the experiment is feasible with at least 10 critical configurations, and low expected benchmark uncertainty. Potential high impact for the understanding of commercially used neutron absorber plates. Next steps are to think about other configurations: rod pitch, other rods – Finalize plate support, uncertainty study. Additionally, the potential use of IER-441 central test region to safely place the plate in the core. Next steps include the Determination of the neutron absorber plate characterization path and the Potential SINBAD benchmark of neutron transmission measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safety Analysis of Chromium-Coated Accident-Tolerant Fuels with Increased Enrichment and Extended Burnup [Slides]

This report documents research and development conducted in support of deployment of accident-tolerant fuels. Specifically, the performance of chromium coating during a beyond design basis accident was investigated. An 18m reference core was considered, and the performance of cases with and without chromium coating compared. An extended cycle length of 24m was then considered with the chromium coating, to determine if the benefit of using the chromium coating was more or less significant than the increased fission product inventory when considering fission product release. The chromium coating model utilized here is a preliminary implementation and further work is recommended on a more detailed model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recovery of Enriched Mo-100 from Low Specific Activity Mo-99/Tc-99m Generator Waste Streams

This study assessed two potential techniques for the extraction of pure Mo-100 target material from Mo-99/Tc-99m waste streams: 1) an established solvent-extraction method tailored for Mo-99 spent solution recycling, and 2) a low-temperature molten salt electrochemical process. By making minor modifications to the conventional solvent extraction method, particularly to accommodate the altered solubility limits arising from elevated Na+ concentrations in the waste, we achieved quantitative Mo recoveries. Although the electrochemical technique offers advantages in scalability and processing simplicity, it proved ineffective in recovering Mo from a NaOH-KOH salt melt.

07 ISOTOPE AND RADIATION SOURCES↗

Flashback Measurements in Hydrogen Enriched Low Swirl Flames Using High Speed OH-PLIF

The fundamentals of stabilized flame dynamics and flashback events in a premixed low swirl burner (LSB) configuration are visualized experimentally using nanosecond (ns)-based high-speed hydroxyl radical planar laser-induced fluorescence (OH-PLIF). Swirlers with two different turning angles, 〖26〗^o and 〖33〗^o and three different center-body hole diameters, 1.08, 1.12 and 1.16 mm with measured swirl numbers varying from 0.43 to 0.49 are tested in this study at atmospheric temperature and pressure inlet conditions. An increase in flashback propensity is observed with increasing ϕ, X_(H_2 ) and decreasing V via detailed investigation of flame lift-off length (L) above the burner rim. Flashback ϕ (ϕ_FB) investigations show an expected linearly increasing trend with decreasing X_(H_2 ) and increasing V for each swirler studied and the results agree well with detailed L investigations in a stable flame configuration. ϕ_FB studies for different swirlers show an increase in flashback resistance with the increase in center-body hole diameter and swirl angle. Spatiotemporally resolved kHz-rate OH-PLIF is a promising technique to observe rapidly occurring flashback events and it can be applied for turbulence-chemistry interaction model validation.

Parajuli, Pradeep↗

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7 Li (CRADA 626) Final Report

The intent of this project was to determine appropriate methodologies for analysis of lithium isotopes for 1) quasi-online monitoring of isotope separations, and 2) high-precision characterization of end-products, including lithium fluoride and lithium-beryllium fluoride (FLiBe). Traditionally, isotopic analysis requires the use of expensive, sophisticated instrumentation with often relatively long analytical timelines. We determined that the use of cheaper, smaller, and easier-to-operate instruments are sufficient for rapid analysis of lithium isotopes to monitor isotope separation efficiencies. In addition, we found that the analytical precision afforded by these lower-cost instruments is comparable to the more sophisticated (i.e., more expensive) instrumentation when the isotopic composition of lithium becomes highly depleted in 6Li. This finding will ultimately help lower costs of manufacturing of depleted lithium that is required for operation of certain designs of Generation IV nuclear reactors.

07 ISOTOPE AND RADIATION SOURCES↗