Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

HYPSTAT (Hydrogen Production, Storage, and Transmission Analysis Tool) [SWR-23-04]

The Hydrogen Production, Storage, and Transmission Analysis Tool (HYPSTAT) is a modeling framework developed by the National Renewable Energy Laboratory (NREL) to support the analysis of hydrogen systems. HYPSTAT focuses on key components of hydrogen infrastructure, particularly electrolytic hydrogen production, hydrogen storage, and hydrogen transmission, as part of the transition to decarbonized energy systems HYPSTAT operates as a supply-to-demand model, taking a fixed exogenous demand as input and optimizing the design and operation of the hydrogen system to meet that demand. It determines cost-optimal configurations based on specified technology options and system constraints.

Brauch, Joseph [National Renewable Energy Laborato↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ASEAN Technical Exchange Workshop for System Operators, Regulators, and Policymakers

This presentation provides an in-depth exploration of power system planning, cross-border electricity trading, and battery energy storage systems (BESS), offering actionable insights for system operators, regulators, and policymakers. The first section delves into power system planning and analysis, focusing on capacity expansion models and resource adequacy studies, including their role in optimizing system efficiency, managing emissions, and addressing system reliability risks. Key considerations, such as integration of transmission into generation planning and the forecasting versus optimization of customer distributed energy resources (DER) technologies, are explored. The session highlights critical trade-offs in spatial granularity and model runtimes, as well as the feasibility of aligning distribution investments with capacity expansion efforts. The second section examines cross-border electricity trading, with an emphasis on resource adequacy concepts such as reliability targets, loss of load expectation (LOLE), and planning reserve margins (PRM). Case studies on reserve market design and coordination across US regions provide insights into improving reserve deliverability and managing interregional power balance and congestion. This section also addresses market-to-market congestion management, including advanced strategies for high-voltage direct current (HVDC) optimization and ancillary service delivery. Finally, the presentation covers the rapid evolution of Battery Energy Storage Systems (BESS), highlighting their operational growth, regulatory frameworks, and use cases in grid flexibility, energy storage, and reliability. The discussion focuses on the benefits of BESS for system stability, resilience, and integration of renewable energy, offering insights into its role as a vital component in the transition toward a more sustainable and flexible grid. Key performance parameters, such as throughput, round-trip efficiency, and state of charge, are also examined.

25 ENERGY STORAGE↗

Life-Cycle Assessment Integration into Scalable Open-Source Numerical Models (LiAISON) for Prospective Impact Analysis of Novel Technologies

Decarbonizing the industrial sector is a significant challenge in achieving a net-zero greenhouse gas (GHG) emissions economy by 2050 and the Paris Agreement, i.e., a global climate change mitigation target of achieving a maximum average temperature change potential of 1.5 Degrees Celsius or less by 2100 with respect to pre-industrial levels. In the United States (US), the industrial sector accounts for 23% of total GHG emissions and is home to a number of hard-to-electrify activities. The chemicals subsector has the single largest subsector emissions profile after direct emissions from fossil fuel combustion and leakage from fossil fuel distribution systems. Within the chemicals subsector, many processes depend on hydrogen or ammonia precursors. Decarbonizing these two commodities would contribute significantly to decarbonizing the industrial sector as hydrogen could also be used for low carbon steel production (e.g., hydrogen-based direct reduction of iron) and other industrial applications. Emerging technologies require the application of prospective life cycle assessment (LCA), which can account for technology (foreground) scaling and process improvements via learning-by-doing, among others. In many cases, the future system context (background) in which the technologies are assumed to operate in is equally relevant. Background scenarios generated by integrated assessment models (IAM) can coherently incorporate potential future dynamics of the energy-climate-human-land system. Further, IAM scenarios are harmonized across socioeconomic and climate change mitigation pathways, which facilitates the comparability of prospective LCAs using different IAMs. We introduce an open source prospective LCA framework, the Life-cycle Assessment Integration into Scalable Open-source Numerical models (LiAISON), to analyze the non-linear relationships between technology foreground and the future energy system background across a series of midpoint and resource use metrics. The integration of LCA and IAM data is achieved using prospective environmental Impact assessment (PREMISE). We showcase it by assessing two Power-to-Hydrogen (PtH2) processes, namely Solid Oxide Electrolysis (SOE) and Polymer Electrolyte Membrane Electrolysis (PEME). We compare the technologies to a baseline of hydrogen production via natural gas-based Steam Methane Reforming (SMR) in a US context of multiple energy system and climate change mitigation futures. Besides providing an analysis that specifies the LCA results ranges with temporal and geospatial explicitness across the two technologies, metrics, and impact assessment methods, this research also aims to establish a base framework that can be expanded to use other IAM generated scenarios and US open-source life cycle inventory (LCI) databases. We find that the temporal environmental performance of either technology or their difference to SMR is directly influenced by the underlying background dynamics. Additionally we compare our results by linking two other prospective models with LiAISON - GCAM (Global Change Assessment Model) and ReEDS (Regional Energy Deployment System) to analyze the effect of changing background scenarios using varying predictions in life cycle analysis.

decarbonizing↗

Automated model generation and parameter estimation of building energy models using an ontology-based framework

This study presents a methodology for automated model generation and parameter estimation of building energy models using semantic modeling and Bayesian estimation. Semantic modeling techniques are used to represent the system components and their interactions, facilitating the automatic generation of a simulation model from dynamic component models. The proposed approach is applied to a case study of a ventilation system where a simulation model is generated, calibrated, and assessed through different performance metrics. These metrics demonstrate the accuracy and reliability of both model point estimates and probabilistic prediction intervals across all model outputs. Overall, the proposed methodology offers a systematic and automated approach to model development and calibration in building energy systems, with potential applications in building performance analysis, monitoring, and optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium-Ion Battery Design for Grid-Scale Energy Storage App

A software that delivers parameters from energy storage system (ESS) to container, rack, module and single cell design, as well as data analysis on arbitrage energy and frequency regulation of ESS in different regions, has been developed. The Lithium-ion Battery Design for Grid-scale Energy Storage App V1.0 has the capability to output the system, module and cell design with the energy, power, capacity, group method, cost of single cell, and single cell test protocol which break down from input energy storage system data in different regions. The default chemistry of the battery is LiFePO4 and graphite. The energy density of the graphite/LiFePO 4 pouch cell ranges from 100 Wh/kg to 200 Wh/Kg in the software. Graphite/LiFePO 4 pouch cell (up to 1Ah in lab) manufacturing line is also built and can be used to evaluate the test protocol, moreover, for electrolyte evaluation in other ESMI seedling projects. The software enables rapid prototyping to accelerate energy storage research, development, and manufacturing.

Liu, Dianying↗

National Park Service: Spotlight on Partnerships

This presentation covers the National Park Service net zero vision and related technical analysis. The NPS/NREL/FEMP partnership include: (1) Partnership spanning more than a decade; (2) Technical support encompasses renewable energy analysis, audit support, fleet technical analysis, resilience assessments, and more.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Policy and Regulatory Environment for Utility-Scale Energy Storage: India

This report is part of a series investigating the potential for utility-scale energy storage in South Asia. The first part of the work is focused on opportunities and barriers for energy storage within existing policy and regulatory frameworks in the region. This report applies the previously-developed Energy Storage Readiness Assessment to evaluate the policy and regulatory environment for energy storage in India. Forthcoming reports will expand this analysis to other countries in South Asia. These evaluations are designed to provide insights on the opportunities and barriers for energy storage growth and deployment in each country. The second part of this work consists of techno-economic analysis to understand the drivers of energy storage investments in South Asia. Using NREL’s power system planning and operational models of South Asia, this analysis will identify potential storage applications and growth under various cost, policy, and demand growth scenarios. In addition, the regulatory and policy barriers and incentive mechanisms identified in the first task will be incorporated into the modeling task to understand their impact on energy storage deployment and operation. Together these studies will inform the applications and value of energy storage on South Asia power systems and policy and regulatory pathways to realize this value.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Using Co-Simulation to Model Interconnect-Scale Power Systems from Loads to Generators

Co-simulation is a modeling technique that allows analysts to combine simulation tools and their corresponding models to exchange data during run-time, allowing the creation of larger and more complex models across heterogeneous domains. HELICS is a co-simulation platform developed over the past six years that has been shown to be effective for these multi-domain analysis. Recently, a HELICS-based analysis was completed where the ERCOT electrical interconnect in the United States was modeled in high detail from bulk power system generation to individual customer loads. This model was used to evaluate a flat-rate and transactive energy tariff with integrated wholesale and retail real-time and day-ahead energy markets. This modeling allows detailed analysis showing how the operations of the power system under these tariffs impact all actors in the power system, from individual customers to bulk power system operators.

co-simulation, HELICS, transactive energy system, ↗

Frequency-dependent hydrodynamic inductance and the determination of the thermal and quantum noise of a superfluid gyroscope

We reexamine mass flow in a superfluid gyroscope containing a superfluid Josephson weak link. We introduce a frequency-dependent hydrodynamic inductance to account for an oscillatory flow of the normal fluid component in the sensing loop. With this hydrodynamic inductance, we derive the thermal phase noise, and hence the thermal rotational noise of the gyroscope. We examine the thermodynamic stability of the system based on an analysis of the free energy. We derive a quantum phase noise, which is analogous to the zero-point motion of a simple harmonic oscillator. The configuration of the studied gyroscope is analogous to a conventional superconducting RF SQUID. We show that the gyroscope has very low intrinsic noise (1.9x10(-13) rad s(-1)/root Hz), and it can potentially be applied to study general relativity, Earth science, and to improve global positioning systems (GPS).

Penanen, Konstantin↗

Analysis of a general circulation model. II - Distribution of kinetic energy in the South Atlantic and Kuroshio/Oyashio systems

It was found (Garzoli et al., 1992) that the general circulation model of Semtner and Chervin (1992) provides accurate descriptions of the Brazil-Malvinas and the Kuroshio/Oyashio confluence systems, except for the fact that the model prediction shows less variability than that present in observations. This paper investigates the problem of model variability by analyzing the mean and the eddy kinetic energy from the model and comparing the values with the Geosat altimeter observations for the South Atlantic Ocean and for the Kuroshio system. It is found that, while the model shows transient eddy activity in the areas that overlap the Geosat observations, the energy level of the model transient motions is considerably smaller following an arch along the bottom topography. The same was found from the comparisons made with values obtained from FGGE and surface drifters. It is suggested that the model is poorly resolving instabilities in the confluence front, and is not resolving other transients appearing in regions of marked topography.

Garraffo, Zulema↗

Mauka Energy FEVER Tool Dataset

Mauka Energy’s dataset, developed under the Forestry Electric Vehicle Energy Routing (FEVER) project and funded by the U.S. Department of Energy’s Small Business Innovation Research program, is a high-resolution geospatial resource designed to support energy modeling for electric log trucks in complex forestry environments. The dataset integrates detailed spatial and road network data to enable accurate simulation of vehicle performance across varied terrain. At its core, the dataset incorporates lidar-derived elevation models, road alignments, and surface classifications from Oregon State University’s McDonald-Dunn Research Forest. These data capture fine-scale variations in slope, curvature, and surface conditions across forest road systems, allowing for vehicle-level analysis of energy consumption and recovery. The dataset also includes data collected on the surrounding public and private road networks in Benton County, Oregon, used in real-world haul routes. These connecting segments provide critical context for modeling transitions between forest operations and regional transportation infrastructure, incorporating attributes such as grade profiles, elevation change, and speed constraints. This combined dataset underpins the development of Mauka Energy’s rolldown tool, which quantifies energy use and regenerative braking potential on downhill and variable-grade segments. By leveraging high-resolution terrain and road data, the FEVER project enables more accurate assessment of electric vehicle feasibility and performance in forestry applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards Prospective LCA Using Life-Cycle Assessment Integration into Scalable Open-Source Numerical Models (LiAISON) Framework for Analyzing Emerging Low-Carbon Technologies

Decarbonizing the industrial sector is a significant challenge in achieving a net-zero greenhouse gas (GHG) emissions economy by 2050 and the Paris Agreement, i.e., a global climate change mitigation target of achieving a maximum average temperature change potential of 1.5 Degrees Celsius or less by 2100 with respect to pre-industrial levels. In the United States (US), the industrial sector accounts for 23% of total GHG emissions and is home to a number of hard-to-electrify activities. The chemicals subsector has the single largest subsector emissions profile after direct emissions from fossil fuel combustion and leakage from fossil fuel distribution systems. Within the chemicals subsector, many processes depend on hydrogen or ammonia precursors. Decarbonizing these two commodities would contribute significantly to decarbonizing the industrial sector as hydrogen could also be used for low carbon steel production (e.g., hydrogen-based direct reduction of iron) and other industrial applications. Emerging technologies require the application of prospective life cycle assessment (LCA), which can account for technology (foreground) scaling and process improvements via learning-by-doing, among others. In many cases, the future system context (background) in which the technologies are assumed to operate in is equally relevant. Background scenarios generated by integrated assessment models (IAM) can coherently incorporate potential future dynamics of the energy-climate-human-land system. Further, IAM scenarios are harmonized across socioeconomic and climate change mitigation pathways, which facilitates the comparability of prospective LCAs using different IAMs. We introduce an open source prospective LCA framework, the Life-cycle Assessment Integration into Scalable Open-source Numerical models (LiAISON), to analyze the non-linear relationships between technology foreground and the future energy system background across a series of midpoint and resource use metrics The integration of LCA and IAM data is achieved using prospective environmental Impact assessment (PREMISE). We showcase it by assessing two Power-to-Hydrogen (PtH2) processes, namely Solid Oxide Electrolysis (SOE) and Polymer Electrolyte Membrane Electrolysis (PEME). We compare the technologies to a baseline of hydrogen production via natural gas-based Steam Methane Reforming (SMR) in a US context of multiple energy system and climate change mitigation futures. Besides providing an analysis that specifies the LCA results ranges with temporal and geospatial explicitness across the two technologies, metrics, and impact assessment methods, this research also aims to establish a base framework that can be expanded to use other IAM generated scenarios and US open-source life cycle inventory (LCI) databases. We find that the temporal environmental performance of either technology or their difference to SMR is directly influenced by the underlying background dynamics. Additionally we compare our results by linking two other prospective models with LiAISON - GCAM(Global Change Assessment Model) and ReEDS (Regional Energy Deployment System) to analyze the effect of changing background scenarios using varying predictions in life cycle analysis.

emissions↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Dynamic Linking of Upstream Energy and Freight Demands for Bio and Fossil Energy Pathways in the Global Change Analysis Model

Comprehensive study of the environmental impacts associated with demand for an energy resource or carrier in any one sector requires a full consideration of the direct and indirect impacts on the rest of the regional and global energy system. It is important to consider the energy that is consumed in producing primary energy resources and energy consumed in transporting these energy resources internationally and domestically in order to produce a complete picture of these impacts. Biofuels are especially complex since they have feedbacks not just to the energy system but also to regional and global crop markets. Different modeling and analysis strategies have been applied to consider these impacts, which occur “upstream” of final energy consumption, with some success. Traditional life cycle models allow for rich technological detail in linking upstream impacts of energy demand with downstream final consumption; however, they cannot by themselves represent dynamic economic feedbacks across multiple sectors and regions over time. Computable general equilibrium (CGE) modeling does account for economic feedback among all sectors and regions; however, CGE modeling does not lend itself to physical representation of technological detail. Partial equilibrium (PE) modeling is a heterogeneous category describing economic models that focus on a subset of the economy, and they differ in coverage and ease in incorporating more sectors and economic links. In this study, we present a strategy for dynamically including the direct and indirect impacts of energy demand with physical and technology detail by explicitly adding these upstream energy and transportation links to GCAM, a PE model of global energy, land use, and emissions. We incorporate the following inter-sectoral linkages: energy inputs to crop production, energy inputs to fossil resource production, and freight transport requirements of energy and agricultural commodities. We assess the implications of explicitly including these links by measuring the global impacts of increased corn ethanol demand in the United States with and without these links included. Although the net global impact of the upstream links on energy and emissions are relatively modest in the scenarios we studied, the inclusion of these links illustrates interesting trade-offs in energy and transportation demand among fossil fuel and agriculture sectors. These sectoral interactions suggest that this level of modeling detail could be important in evaluating future analytical questions.

Sampedro Martinez de Estivariz, Jon↗