Comparison of Analytical Shielding Calculations for NSLS-II Linac Lateral Wall with FLUKA Monte-Carlo Program

The bulk shielding for NSLS II accelerator enclosures has been designed to reduce the dose rates to less than 0.5 mrem/h at the occupied regions during normal operation. The lateral wall for Linac enclosure is designed to protect personnel from the transverse radiation. The current Linac lateral wall is composed of 1 m concrete, based on the analytical calculations using Swansons’ thick target approximation [1]. The dose rate calculations with current Linac lateral shielding (general area and penetrations) have been carried out by FLUKA. The FLUKA Monte Carlo results were compared with the analytical calculation [1]. The dose rates calculated by SHIELD11 [2] program for limited cases have also been included in this technical note.

36 MATERIALS SCIENCE↗

Beamline SRX (05-ID, IVU 21): 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline SRX (05-ID, In-Vacuum Undulator) was conducted on March 20, 2015 in accordance with the Beamline SRX (05-ID) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the 3, 05-ID beamline enclosures (05-ID-A, 05-ID-B and 05-ID-D) and the transport pipe in between 05-ID-A, 05-ID-B and 05-ID-D. Enclosure 05-ID-C currently has only a transport pipe connecting 05-ID-B and 05-ID-D, but will serve as the experimental end station as future branch line for the second IVU. During the surveys the stored beam current varied between 21.04 and 24.87 mA, the 05ID straight section vacuum was around 0.43 ntorr, andfront-end slits opened near their hard stop limits.

36 MATERIALS SCIENCE↗

Beamline XPD (28-ID, DW 100) 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline XPD (28-ID, Damping Wiggler) was conducted on March 16, March 30 and April 09, 2015 in accordance with the Beamline XPD (28-ID) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the two 28-ID beamline enclosures in use (28-ID-A, 28-ID-C) and the transport pipe in between 28-ID-A and 28-ID-C. Enclosure 28-ID-B currently has only a transport pipe connecting 28-ID-A and 28-ID-C, and is expected to be used as the experimental end station for future branch line.

36 MATERIALS SCIENCE↗

Proof Testing of Small-Scale HE Press Shielding

High explosives pressing activities at Los Alamos National Laboratory have played a critical role in meeting the core missions of the lab since its early days. Small scale pressing (25 grams of energetic material or less) constitutes a significant portion of current production and much of this occurs as an attended operation. Workers that are present during HE pressing operations are to be protected from blast and fragment dangers associated with the potential violent reaction of the energetic material being pressed. Safety is paramount in all HE operations, and the ongoing evolution of analysis and mitigation of hazards contributes strongly to the development of adequate protections for personnel. Attended pressing operations satisfying Class 1 Level Protection criteria, until recently, have been allowed for small scale pressing activities on the basis of an undocumented design of shielding enclosures used at LANL. Recent review of the shield design has determined the necessity of proof testing an adequate enclosure and thoroughly documenting the test results and fabrication specifications. This will provide a basis for continuing attended operations and guidance for future design iterations. The results of the testing described in this report provide sufficient assurance that the new shield design is adequate to protect attendant workers against injury from direct blast and fragments resulting from full detonation of the maximum allowable mass of explosives (less than 25 grams) confined in a uniaxial pressing configuration typical for Los Alamos National Laboratory.

42 ENGINEERING↗

Comparative Study of Techno-Economics of Lithium-Ion and Lead-Acid Batteries in Micro-Grids in Sub-Saharan Africa

Microgrids stand to play an important role in expanding electricity access in Sub-Saharan Africa. Batteries, which are often a core element of micro-grids, represent a substantial portion of the capital cost and are therefore an important component of developing sustainable business models for micro-grid deployment. As a result, understanding key considerations for selecting a battery type and operating it effectively are foundational for taking micro-grid growth to scale across the sub-continent. While batteries have been deployed in many systems worldwide over the past few decades, unanswered questions remain on how best to apply them to the context of off-grid micro-grids in Sub-Saharan Africa. Building on analytical work with developers in Sub-Saharan Africa and tools at NREL, this report investigates battery techno-economics and optimal operation in micro-grids, including evaluating criteria to decide between deploying lead acid or lithium-ion batteries, discussing key design considerations for the enclosures that house the batteries, and how to effectively condition the enclosure.

25 ENERGY STORAGE↗

Development and Validation of SAM Multi-dimensional Flow Model for Thermal Mixing and Stratification Modeling

Thermal mixing and stratification in large pools or enclosures are very important phenomena that are critical to nuclear reactor safety. Because of the wide ranges of time and length scales associated with such phenomena, accurate modeling and simulation of thermal mixing and stratification remain as the key unresolved, challenging problems for reactor transient analyses. In traditional system analysis codes, simplified zero-dimensional (0-D) models are widely used for their high numerical efficiency, but they generally suffer from very limited prediction accuracies or range of applicability. Like traditional system analysis codes, the current version of the SAM code has implemented such simplified 0-D and one-dimensional mixing models. On the other hand, high-resolution Computational Fluid Dynamics (CFD) tools are often used to model complex thermal mixing and stratification phenomena. They are, however, generally numerically expensive, and they require large amounts of computational resources. It is therefore desirable to implement advanced and efficient thermal mixing and stratification modeling capabilities embedded in a system analysis code. This approach will improve the accuracy of reactor safety analyses when thermal mixing and stratification are involved, and also avoid using the large computational resources needed for high-resolution CFD analysis. Currently, with the support of the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation program, an effort has been launched to develop and implement a multi-dimensional flow model in the system analysis code SAM, and demonstrate its applications to model thermal mixing and stratification phenomena in large enclosures. The main outcomes of this research and development activity are summarized in this report, which presents an attempt to include a built-in advanced multi-dimensional flow model in a system analysis code with the focus on overcoming the simulation challenges of thermal mixing and stratification phenomena. In this report, we start with the introduction of existing SAM code capabilities to simulate thermal mixing and stratification phenomena, which is followed by a short summary of the multi-dimensional model implemented in the SAM code, including both the physical model and the Finite Element Method code implementation. In this study, two options were implemented in the SAM code to model turbulent flows: a relatively simple built-in turbulence model and an interface to accept externally computed turbulent viscosities (e.g., from a high- resolution CFD simulation). Code validation studies on this newly added capability were then carried out to compare SAM simulation results with experimental data from the SUPERCAVNA facility, which was designed to study the complex flow recirculation and thermal stratification phenomena relevant to sodium fast reactor designs. In this study, one transient and two steady-state test cases were used for code validation. Different approaches have been used to model the complex turbulence flow fields in the SUPERCAVNA facility. A highly simplified zero-equation turbulence model was first used, but it was determined that it is too simple to capture the complex turbulence flow fields in these test cases. Subsequently, the code validation continued with the use of turbulent viscosity data from high-resolution STAR-CCM+ CFD simulations to improve the accuracy of the results. Using this approach, the SAM simulation results showed very good agreement with both the SUPERCAVNA experimental data and STAR-CCM+ simulation results. In this report, we demonstrate the development, implementation, and successful validation of a multi-dimensional flow model in the SAM code, which aims to improve the simulation accuracy for complex thermal mixing and stratification phenomena. Lessons have also been learned, including that in cases where the flow fields are not well predicted by the zero-equation model, the iinput of turbulent viscosities from an external source can enhance the overall predictive capabilities needed to accurately capture complex thermal-hydraulic phenomena. Therefore, future research will be needed to further improve the code’s capabilities, such as by developing a more efficient and robust approach to capture the turbulence effects in the SAM code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wireless Instrumented RB Experiment Preliminary Design and Analysis

The ability to deploy new nuclear fuels for current or future reactor concepts requires carefully designed experiments to generate data to support fuel qualification. Ideally these experiments would include state of-the-art sensing to maximize the amount of in situ data that can be collected during operation. Furthermore, advanced reactor systems can take advantage of integrated in-core sensing technologies to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator’s understanding of limiting peaking factors. Before any novel sensing technologies can be readily adopted for nuclear applications, they must first demonstrate acceptable performance in test reactors. This report summarizes the preliminary design and analysis of the most highly instrumented irradiation experiment ever performed in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The Wireless Instrumented RB Experiment 2021 (WIRE-21) will test a wide range of sensors including wireless sensors being developed by Westinghouse Electric Company (WEC) that could provide in situ measurements of peak fuel temperatures and fuel rod pressurization due to fission gas release. The ability to wirelessly transmit a signal through the fuel rod’s cladding is critical to improving fuel monitoring capabilities without requiring signal penetrations through the cladding pressure boundary, which would significantly impact fuel fabrication, handling, and operation. Other sensors that will be tested in WIRE-21 include an array of thermocouples, self-powered neutron detectors (SPNDs), and spatially distributed fiber-optic temperature sensors. More generally, WIRE-21 will establish a flexible irradiation vehicle design to allow accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. This report summarizes the mechanical design for WIRE-21, the experimental test matrix, initial neutronic and thermal design analyses, and the active monitoring and control system enhancements necessary to support testing of advanced sensor technologies. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) relevant to light water reactors (LWRs), but the flexible design of the experiment vehicle allows much higher operating temperatures (>1,100°C). Neutronic calculations determine the neutron flux conditions as well as the nuclear heating within the experiments. These results are used as inputs to detailed thermal finite element calculations, which are required to evaluate the complex, three-dimensional heat transfer that occurs within WEC’s wireless sensor enclosures. Initial results show that the temperatures of the sensors’ enclosures and the metal bellows can be operated near the temperature range of LWR coolants and cladding while simultaneously increasing the temperature of a surrogate fuel material to values in the range of 800–1200°C to simulate centerline fuel temperatures during LWR operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Residential Façade Upgrades: Market Assessment and Recommendations

In support of DOE’s move toward transformational whole-building upgrades and enclosure solutions, the Pacific Northwest National Laboratory (PNNL) and National Renewable Energy Laboratory (NREL) are partnering and collaborating with leading building science researchers and home-performance entities to identify and characterize technical and economic barriers to façade retrofits in an effort to identify market-viable façade solutions and opportunities for an actionable plan to transform the market. The project includes partnerships with Building Science Corporation (BSC) and a combination of strategic implementation partners with home-performance and retrofit expertise and industry contacts. The project will include expert advisory and review consultation from Lawrence Berkeley National Laboratory’s (LBNL’s) Residential Windows & Attachments team and Oak Ridge National Laboratory’s Building Envelope team. The project consists of three parts: 1. a market analysis that captures the current state of the façade retrofit market and includes housing characteristics and retrofit costs, façade retrofit approaches and materials, contractor business models and workforce requirements to support advanced façade approaches; 2. an economic analysis focused on the viability of advanced façade retrofit approaches and materials; and 3. field demonstration of façade retrofits that include enhanced insulation/air-sealing and window technologies in multiple climate zones. This report represents the market analysis, as outlined in item 1 above. The goal of this analysis is to provide a techno-economic study that supports comprehensive retrofits of residential enclosures that include traditional approaches, and integrated wall assemblies and windows that result in durable, energy efficient, and marketable strategies. This study will provide a better knowledge base regarding the viable market for façade retrofit strategies, identify the barriers to uptake, analyze economic opportunities, and develop documentation specifically aimed to overcome technical and market barriers associated with installation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Radiation Effects on Line Heat Detection Cable AP Hot Cells Fire Detection at Brookhaven National Laboratory

Hot cells are used to safely shield workers from high radiation environments while allowing a process to take place within the cell's shielded enclosure, often with the assistance of remote manipulators. The interior of a cell may not be accessible by personnel for years at a time, either due to the lingering radiation environment or due to the constant use of these specialized pieces of equipment. High radiation levels are known to cause undesirable effects and changes to different materials in varying degrees. Selecting equipment for a radiation environment requires an evaluation of materials used (preferably completed assembles), to ensure all interactions of materials are known and ensure that the equipment will have a high degree of reliability and functionality over the intended life of the facility. Hot cells contain systems to support the primary purpose of the enclosure. Fire detection is one such support system. Safety of hot cell operations often establish limits on the amounts of combustibles with the cells, but the presence of some combustible materials is unavoidable. Fire detection is provided to quickly detect a fire and summon manual intervention before damage is too great. Detection may also be used to initiate fire suppression systems. As a safety system, fire detection needs to remain functional to protect the facility throughout the facility's life. Equally important is that the false alarms from the fire detection are minimized to retain confidence in the alarm system and avoid unnecessary interruptions in the hot cell operations. There are many types of fire detection available with various pros and cons. Not all types of fire detection are suited for hot cell application.

36 MATERIALS SCIENCE↗

High-Temperature Linear Receiver Enabled by Multicomponent Aerogels

Concentrating solar thermal (CST) technology has significant potential mainly due to its dispatchability and low cost of storage. However, to compete with other sources, including utility-scale solar PV, its final cost (cents/kWh) still needs to be lowered. Cost reduction can be achieved by improving the system level efficiency of the CST plants through the deployment of advanced power cycles, which operate at high temperatures of ~700°C. However, optical, and thermal losses pose a major challenge to the efficiency of such CST systems. The overall aim of this project is to investigate and de-risk a linear solar receiver concept called an Aerogel Insulated Receiver (AIR) that generates high temperatures (up to 700°C) at a low solar concentration ratio (<100) and with a high collection efficiency (optical × receiver). Our prior work has demonstrated the thermal stability1 and optical and heat-insulating properties2,3 of transparent aerogel insulation at a one-inch scale. The focus of this work is on (1) co-optimization of the geometry of the aerogel tile and receiver enclosure to fit a standard parabolic collector (PTC), (2) scale-up of aerogels into 4-inch tiles while preserving key properties, (3) experimental measurement of receiver heat loss (W/m) in a >70-cm test stand and validation of anticipated receiver performance at high temperatures. Regarding (1), appropriate optical and thermal models for a parabolic trough receiver (PTR) are developed and validated. The geometry of the aerogels and the receiver enclosure are co-optimized to maximize the collection efficiency. The model predicts a 54% collection efficiency at 700°C for an AIR design based on flat aerogels. By combining the collection efficiency with the power block efficiency of supercritical CO 2 cycles, we predict >10% improvements in peak plant efficiency relative to existing line-focusing CST systems. The application of curved plasmonic aerogels is predicted to further increase the collection efficiency to 64%. Regarding (2), we demonstrate the successful development of 6-inch-long refractory aerogel tiles with optical, thermal, and stability characteristics consistent with our prior work. This scale-up requires a transition to a larger ALD station and modifying the ALD process variables such as exposure time and the number of precursor doses. Regarding (3), we design and develop an AIR test stand measuring 3 feet in length. Heat loss performance analysis is carried out using the test stand. The results indicate that aerogel insulation can significantly reduce receiver thermal losses at the high operating temperatures required for next-generation PTRs. The experimental results agree with the heat loss performance predicted by our receiver model. Lastly, we conducted preliminary failure mode and effects (FMEA) and techno-economic (TEA) analyses to identify failure mitigation strategies and commercial opportunities, respectively. Overall, this project identifies key opportunities and challenges in deploying aerogel insulating receivers in next-generation line-focusing CST technologies.

14 SOLAR ENERGY↗

Assessing Methodologies for Detecting Water Intrusion in Wall Systems: Phase 2

Studies by the University of Florida, the Environmental Protection Agency (EPA) and the U.S. Department of Housing (HUD) have revealed that there is a substantial fraction of commercial and residential buildings that have been exposed to moisture resulting in damage or durability problems. Water intrusion into building envelope components leads to a variety of undesirable conditions such as mold, wood rot, corrosion, and aesthetic damage. Tests methods that are presently used to evaluate the amount of water intrusion into a building envelope component are usually qualitative in nature. For example, ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference requires that you “observe and record points of water leakage, if any.” This test was originally developed to assess the performance of fenestration products but is commonly adapted to evaluate other enclosure assemblies. However, when it is typically used for walls, this procedure is limited to recognizing if the moisture is visually observable from the backside side of the sheathing. It does not address moisture that is absorbed in the layers of the building envelope component, which could impact the durability of the assembly. Clearly a quantitative means of determining water penetration would improve the quality of this type of test and assist with better understanding the resultant impact on enclosure assemblies. In 2018-20, Oak Ridge National Laboratory, in conjunction with the Air Barrier Association of America, initiated a research project to address this issue. The purpose of that study was to evaluate nine different methods of detecting moisture intrusion through a wall assembly. air and water barrier. The wall assemblies included metal frame construction faced with gypsum sheathing and both self-adhered and fluid applied air and water barriers (AWB) were evaluated for this exercise. This project did not test the efficacy of the different AWBs, rather, fasteners were purposely installed in various ways to foster water penetration and activate the different methods of detection. Each detection method was evaluated for five features that included simplicity of use, cost of implementation, whether the method was quantitative or subjective, accuracy, and applicability. A scale of green/yellow/red was used to assess each feature where green was acceptable, yellow was borderline, and red was not to be pursued at this time. This report covers additional research that has been undertaken to extend the activities initiated in this earlier project with refinements for specific detection methods and considerations for expansion related to field versus laboratory testing standards.

42 ENGINEERING↗

Bench-Scale Development of a Novel Direct Air Capture Technology Using High-Capacity Structured Sorbents

The work performed under this project has resulted into development of a DAC technology utilizing a structured sorbent to capture CO 2 from ambient air with a key innovation of direct Joule heating of the sorbent for CO 2 desorption. A working SMA, fully integrated with an electrically resistive heating layer, high surface area support, and high CO 2 capacity sorbent coated onto a commercial ceramic monolithic substrate, was successfully developed and demonstrated over >200 adsorption-desorption cycles in a high-fidelity bench test unit directly using ambient air. A cordierite-based monolith was selected as a substrate owing to its high surface area, low bulk density, low heat capacity, and commercial availability. Reaction kinetics study conducted during this project led to development of a promoter for the base Na 2 CO 3 sorbent that could be incorporated into the sorbent to enhance to achieve higher CO 2 adsorption/desorption rates, greater working capacity, and reduced regeneration temperature. An accelerated aging study was conducted in a TGA to determine sorbent stability and no degradation in the sorbent performance was observed even after 250 adsorption-desorption cycles. An electrically resistive heating layer was developed with tunable electrical properties. The heating layer was coated onto the selected cordierite substrate. Aging studies performed showed the electrical properties and heating performance was stable after 500 heating and cooling cycles. The collective findings on the selected cordierite substrate, robust heating layer, promoter and sorbent selection were used to synthesize a full, 6”x6” SMA for bench-scale testing. The bench-scale DAC system was constructed to test full size SMAs using real ambient air for adsorption and joule heating for regeneration. After completing shakedown and commissioning of the 1 kg/day of CO 2 capacity DAC bench unit, an extended operation was performed to complete over 230 cycles with the full size SMA. This testing showed no observable degradation in sorbent performance. A detailed process model, TEA and LCA were developed for a conceptual 100,000 TPY CO 2 removal DAC facility. The LCA results show the net CO 2 e emissions from the DAC system are highly dependent on the electricity source. All other factors, including SMA manufacturing, materials for facility enclosure, etc., are minor cost contributors compared to the energy consumption required for CO 2 removal. With the successful development and validation of the SMA for the sustained performance for CO 2 removal from ambient air with joule heated regeneration in this project, a fully integrated 1 TPY bench-scale DAC system is currently in development with the support of DOE/FECM (DE-FE0032243). The project objective is to demonstrate the engineering design of the DAC system to produce a continuous, high purity CO 2 stream from ambient air. This project will address and validate key engineering features of the DAC system including the gas sealing mechanism and panels, enclosure and air contactor design, and automation sequence to achieve continuous CO 2 production.

42 ENGINEERING↗

Infrared Thermometer Instrument Handbook

The infrared thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the brightness temperature of the scene in its field of view. The ground IRT (sometimes referred to as the upwelling instrument) lens has a wide field of view for measuring the radiating temperature of the ground surface. It measures in a narrow range of the infrared band, details of which can be found in Table 2. It provides data to the user averaged to 1-minute resolution. The infrared thermometer for sea-surface temperature (IRTSST) is a ship-based radiation pyrometer that provides measurements of the temperature of the sea surface. The upwelling infrared emission is determined with two different IRTs for over-ocean field campaigns and the data is at 1-second temporal resolution. The IRTs are mounted at heights varying between 2 and 42 m above the ground, oriented so the mounting platform and other human made objects are not in the field of view, and also to ensure that the ground and vegetation cover are representative of the local area. The Heitronics IRT is generally mounted inside a small enclosure, and the Apogee IRT is shielded by a cylindrical enclosure that is part of the design from the manufacturer.

47 OTHER INSTRUMENTATION↗

Status of initial testing of the H2SO4 section of the ILS experiment.

A sulfuric acid catalytic decomposer section was assembled and tested for the Integrated Laboratory Scale experiments of the Sulfur-Iodine Thermochemical Cycle. This cycle is being studied as part of the U. S. Department of Energy Nuclear Hydrogen Initiative. Tests confirmed that the 54-inch long silicon carbide bayonet could produce in excess of the design objective of 100 liters/hr of SO{sub 2} at 2 bar. Furthermore, at 3 bar the system produced 135 liters/hr of SO{sub 2} with only 31 mol% acid. The gas production rate was close to the theoretical maximum determined by equilibrium, which indicates that the design provides adequate catalyst contact and heat transfer. Several design improvements were also implemented to greatly minimize leakage of SO{sub 2} out of the apparatus. The primary modifications were a separate additional enclosure within the skid enclosure, and replacement of Teflon tubing with glass-lined steel pipes.

08 HYDROGEN↗

System Description for the K-25/K-27 D&D Project Polyurethane Foam Delivery System, East Tennessee Technology Park, Oak Ridge, Tennessee

The Foam Delivery System used in the decontamination and decommissioning (D&D) project for the K-25/K-27 Buildings at the East Tennessee Technology Park (ETTP) is comprised of a trailer-mounted Gusmer{reg_sign} H20/35 Pro-TEC Proportioning Unit and the associated equipment to convey electrical power, air, and foam component material to the unit. This high-pressure, plural-component polyurethane foam pouring system will be used to fill process gas and non-process equipment/piping (PGE/P) within the K-25/K-27 Buildings with polyurethane foam to immobilize contaminants prior to removal. The system creates foam by mixing isocyanate and polyol resin (Resin) component materials. Currently, the project plans to utilize up to six foaming units simultaneously during peak foaming activities. Also included in this system description are the foam component material storage containers that will be used for storage of the component material drums in a staging area outside of the K-25/K-27 Buildings. The Foam Delivery System and foam component material storage enclosures (i.e., Foaming Component Protective Enclosures) used to store polymeric methylene diphenyl diisocyanate (PMDI) component material are identified as Safety Significant (SS) Structures, Systems and Components (SSC) in the Documented Safety Analysis (DSA) for the project, Documented Safety Analysis for the K-25 and K-27 Facilities at the East Tennessee Technology Park, Oak Ridge, Tennessee, DSA-ET-K-25/K-27-0001.

54 ENVIRONMENTAL SCIENCES↗

TMAP7 User Manual

The TMAP Code was written at the Idaho National Engineering and Environmental Laboratory by Brad Merrill and James Jones in the late 1980s as a tool for safety analysis of systems involving tritium. Since then it was upgraded to TMAP4 and has been used in numerous applications including experiments supporting fusion safety, predictions for advanced systems such as the International Thermonuclear Experimental Reactor (ITER), and estimates involving tritium production technologies. Its further upgrade to TMAP2000 and now to TMAP7 was accomplished in response to several needs. TMAP and TMAP4 had the capacity to deal with only a single trap for diffusing gaseous species in solid structures. TMAP7 includes up to three separate traps and up to 10 diffusing species. The original code had difficulty dealing with heteronuclear molecule formation such as HD and DT under solution-law dependent diffusion boundary conditions. That difficulty has been overcome. TMAP7 automatically generates heteronuclear molecular partial pressures when solubilities and partial pressures of the homonuclear molecular species are provided for law-dependent diffusion boundary conditions. A further sophistication is the addition of non-diffusing surface species. Atoms such as oxygen or nitrogen or formation and decay or combination of hydroxyl radicals on metal surfaces are sometimes important in reactions with diffusing hydrogen isotopes but do not themselves diffuse appreciably in the material. TMAP7 will accommodate up to 30 such surface species, allowing the user to specify relationships between those surface concentrations and partial pressures of gaseous species above the surfaces or to form them dynamically by combining diffusion species or other surface species. Additionally, TMAP7 allows the user to include a surface binding energy and an adsorption barrier energy. The code includes asymmetrical diffusion between the surface sites and regular diffusion sites in the bulk. All of the previously existing features for heat transfer, flows between enclosures, and chemical reactions within the enclosures have been retained, but the allowed problem size and complexity have been increased to take advantage of the greater memory and speed available on modern computers. One additional feature unique to TMAP7 is the addition of radioactive decay for both trapped and mobile species. Whereas earlier versions required a separate FORTRAN compiler to operate, TMAP7 is based on a publiclicense compiler, distributed with the code.

08 HYDROGEN↗

beam loss scenarios for MuCool Test Area

The MuCool Test Area (MTA) is an intense primary beam facility derived directly from the Fermilab Linac to test heat deposition and other technical concerns associated with the liquid hydrogen targets, gas-filled RF cavities, and other apparatus being developed to cool intense, large-emittance muon beams. In this study the results of Monte Carlo modeling of several beam loss scenarios are presented. The MTA facility was designed to test targets and other muon cooling apparatus using the intense Fermilab Linac beam. The requested intensity of the proton beam for the MTA is essentially full Linac capability, or 1.6 x 10{sup 13} protons per pulse and an energy of 400 MeV. Two modes of operation will be supported in the MuCOOL beamline: one mode for emittance measurements (and beamline studies) and a second mode for MTA experiments. Maximum beam intensity for these two modes is: 9.6 x 10{sup 15} protons/hr - 600 beam pulses/hour of full Linac beam pulse intensity (1.6 x 10{sup 13} protons/pulse) to the emittance beam absorber and 9.6 x 10{sup 14} protons/hour - 60 beam pulses/hour of full Linac beam pulse intensity to experiments in the MTA experimental hall. This extremely high intensity implies careful investigation into and application of proper shielding materials and configuration in order to satisfy the following two requirements: (i) to reduce the instantaneous dose rate outside of the experimental enclosure to prescribed levels appropriate for the area considered; (ii) to ensure the civil construction of the hall is capable of additional shielding and, further, that the weight of the shielding is commensurate with the loading specifications of the enclosure, notably the ceiling. A number of scenarios for beam loss at different locations were studied in order to determine the maximum beam intensity which is in compliance with the existing shielding. The modeling was performed with the MARS15 code.

43 PARTICLE ACCELERATORS↗

Turbulent Natural Convection in a Square Cavity with a Circular Cylinder

In this paper, numerical simulations of high Rayleigh number flows (10 8 -10 10 ) were conducted to investigate the turbulent fluid flow and thermal characteristics of natural convection induced by a centrally placed hot cylinder in a cold square enclosure. The effect of the aspect ratio (radius of the cylinder to the side of the cavity) was investigated for three values (0.1, 0.2, and 0.3) for each Rayleigh number. Effects of turbulence induced by the high Rayleigh number (>10 7 ) were computed by using the unsteady k-ω model. A spectral-element method with high polynomial order (high resolution) was used to solve the system of unsteady time-averaged equations of continuity, momentum, and energy, along with the turbulence equations. Detailed comparison with other numerical work is presented. Contours of velocity, temperature, and turbulence quantities are presented for various high Rayleigh numbers. Also presented is the influence of the Rayleigh number on the local Nusselt number on the centrally placed hot cylinder and the cold enclosure walls. Time-marching results show that the steady-state solutions can be obtained even for high Rayleigh numbers considered in this study. The results also show that the average and peak Nusselt numbers roughly double for each order of magnitude increase of the Rayleigh number for all radii considered. Finally, a correlation for the average Nusselt number as a function of Rayleigh number and aspect ratio is also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗