Morphological Processing of Ultraviolet Emissions of Electrical Corona Discharge for Analysis and Diagnostic Use

Electron cascades from electrical discharge produce secondary emissions from atmospheric plasma in the ultraviolet band. For a single point of discharge, these emissions exhibit a stereotypical discharge morphology, with latent information about the discharge location. Morphological processing can uncover the location and therefore can have diagnostic utility.

Schubert, Matthew R.↗

Surface analysis of anodized aluminum clamps from NASA-LDEF satellite

Surface analysis results of selected anodized aluminum clamps containing black (Z306) and white (A276) paints which received nearly six years of Low Earth Orbit (LEO) exposure on the Long Duration Exposure Facility are reported. Surface analytical techniques, including x-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and scanning electron microscopy/energy dispersive analysis by x-ray (SEM/EDAX), showed significant differences in the surface composition of these materials depending upon the position on the LDEF. Differences in the surface composition are attributed to varying amounts of atomic oxygen and vacuum ultraviolet radiation (VUV). Silicon containing compounds were the primary contaminant detected on the materials.

Grammer, H. L.↗

The room-temperature dissociation of the compound Au3Si

Three gold-18.6 at.% silicon specimens which were solidified by quenching from above the liquidus temperature have been reexamined after being stored at room temperature for about 8 years. It was found that the 'metastable' compound Au3Si formed on quenching had begun to dissociate by a surface nucleated, solid-state reaction. The reaction front had advanced about 0.2 mm from the surface, leaving a rim of dissociation products. These dissociation products were studied using optical and scanning electron microscopy, electron beam microprobe analysis and an X-ray micro-diffraction technique. It was concluded that the reaction produces elemental gold and silicon, as at higher reaction temperatures, but that the scale of dispersion is so extremely fine that the resulting microstructure cannot be resolved by scanning electron microscopy.

Bhattacharya, D.↗

Analysis of Particulate and Fiber Debris Samples Returned from the International Space Station

During the period of International Space Station (ISS) Increments 30 and 31, crewmember reports cited differences in the cabin environment relating to particulate matter and fiber debris compared to earlier experience as well as allergic responses to the cabin environment. It was hypothesized that a change in the cabin atmosphere's suspended particulate matter load may be responsible for the reported situation. Samples were collected and returned to ground-based laboratories for assessment. Assessments included physical classification, optical microscopy and photographic analysis, and scanning electron microscopy (SEM) evaluation using energy dispersive X-ray spectrometry (EDS) methods. Particular points of interest for assessing the samples were for the presence of allergens, carbon dioxide removal assembly (CDRA) zeolite dust, and FGB panel fibers. The results from the physical classification, optical microscopy and photographic analysis, and SEM EDS analysis are presented and discussed.

Perry, Jay L.↗

Transmission Electron Microscopy of Magnetite Plaquettes in Orgueil

Magnetite sometimes takes the form of a plaquette - barrel-shaped stack of magnetite disks - in carbonaceous chondrites (CC) that show evidence of aqueous alteration. The asymmetric nature of the plaquettes caused Pizzarello and Groy to propose magnetite plaquettes as a naturally asymmetric mineral that can indroduce symmetry-breaking in organic molecules. Our previous synchrotron X-ray computed microtomography (SXRCT) and electron backscatter diffraction (EBSD) analyses of the magnetite plaquettes in fifteen CCs indicate that magnetite plaquettes are composed of nearly parallel discs, and the crystallographic orientations of the discs change around a rotational axis normal to the discs surfaces. In order to further investigate the nanostructures of magnetite plaquettes, we made two focused ion beam (FIB) sections of nine magnetite plaquettes from a thin section of CI Orgueil for transmission electron microscope (TEM) analysis. The X-ray spectrum imaging shows that the magnetite discs are purely iron oxide Fe3O4 (42.9 at% Fe and 57.1 at% O), which suggest that the plaquettes are of aqueous origin as it is difficult to form pure magnetite as a nebular condensate. The selected area electron diffraction (SAED) patterns acquired across the plaquettes show that the magnetite discs are single crystals. SEM and EBSD analyses suggest that the planar surfaces of the magnetite discs belong to the {100} planes of the cubic inverse spinel structure, which are supported by our TEM observations. Kerridge et al. suggested that the epitaxial relationship between magnetite plaquette and carbonate determines the magnetite face. However, according to our TEM observation, the association of magnetite with porous networks of phyllosilicate indicates that the epitaxial relationship with carbonate is not essential to the formation of magnetite plaquettes. It was difficult to determine the preferred rotational orientation of the plaquettes due to the symmetry of the cubic structure, however, we are able to observe small but consistent rotational orientation across several discs within a plaquette.

Chan, Q. H. S.↗

ESIAC: A data products system for ERTS imagery (time-lapse viewing and measuring)

An Electronic Satellite Image Analysis Console (ESIAC) has been developed for visual analysis and objective measurement of earth resources imagery. The system is being employed to process imagery for use by USGS investigators in several different disciplines studying dynamic hydrologic conditions. The ESIAC provides facilities for storing registered image sequences in a magnetic video disc memory for subsequent recall, enhancement, and animated display in monochrome or color. The unique feature of the system is the capability to time-lapse the ERTS imagery and/or analytic displays of the imagery. Data products have included quantitative measurements of distances and areas, brightness profiles, and movie loops of selected themes. The applications of these data products are identified and include such diverse problem areas as measurement of snowfield extent, sediment plumes from estuary dicharge, playa inventory, phreatophyte and other vegetation changes. A comparative ranking of the electronic system in terms of accuracy, cost effectiveness and data output shows it to be a viable means of data analysis.

Evans, W. E.↗

Zirconium, hafnium, and rare earth element partition coefficients for ilmenite and other minerals in high-Ti lunar mare basalts - An experimental study

Partition coefficients were determined for Gd, Lu, Hf and Zr among ilmenite, armalcolite, and synthetic high-Ti mare basaltic melts at temperatures from 1122 deg to 1150 deg, and at oxygen fugacities of IW x 10 exp 0.5, by in situ analysis with an electron microprobe, using samples doped to present concentration levels. Coefficients for Zr were also measured for samples containing 600-1600 ppm Zr using this microprobe. In addition, coefficients were determined for Hf and Zr between chromian ulvospinel and melt, for Hf between pigeonite and melt, and for Lu between olivine and melt by microprobe analysis of samples doped to present levels. Values measured using the microprobe were in agreement with the values measured by analyzing mineral separates from the same run products by isotope dilution. Coefficient values for ilmenite are less than 0.01 for the LREE, are around 0.1 for the HREE, and are several times greater than this for Zr and Hf.

Mckay, G.↗

Electron trapping in rad-hard RCA IC's irradiated with electrons and gamma rays

Enhanced electron trapping has been observed in n-channels of rad-hard CMOS devices due to electron and gamma-ray irradiation. Room-temperature annealing results in a positive shift in the threshold potential far beyond its initial value. The slope of the annealing curve immediately after irradiation was found to depend strongly on the gate bias applied during irradiation. Some dependence was also observed on the electron dose rate. No clear dependence on energy and shielding over a delidded device was observed. The threshold shift is probably due to electron trapping at the radiation-induced interface states and tunneling of electrons through the oxide-silicon energy barrier to fill the radiation-induced electron traps. A mathematical analysis, based on two parallel annealing kinetics, hole annealing and electron trapping, is applied to the data for various electron dose rates.

Danchenko, V.↗

Flight control electronics reliability/maintenance study

Collection and analysis of data are reported that concern the reliability and maintenance experience of flight control system electronics currently in use on passenger carrying jet aircraft. Two airlines B-747 airplane fleets were analyzed to assess the component reliability, system functional reliability, and achieved availability of the CAT II configuration flight control system. Also assessed were the costs generated by this system in the categories of spare equipment, schedule irregularity, and line and shop maintenance. The results indicate that although there is a marked difference in the geographic location and route pattern between the airlines studied, there is a close similarity in the reliability and the maintenance costs associated with the flight control electronics.

Dade, W. W.↗

Photodetachment of electrons from phosphide ion - The electron affinity of PH2.

Measurement of the relative cross section for photodetachment of electrons from PH2(-) in the wavelength region 725 to 1020 nm (1.71 to 1.22 eV). An ion cyclotron resonance spectrometer was used to generate, trap, and detect the negative ions, and two light sources were employed to study photodetachment: a 1000-W xenon arc lamp with a grating monochromator and a continuously tunable laser. A single sharp threshold in the cross-section curve was observed, and a detailed analysis yielded an electron affinity value of 1.25 plus or minus 0.03 eV.

Smyth, K. C.↗

Integrated material-surface analyzer

These 10 surface-analysis tests can be run without breaking vacuum: secondary-ion mass spectroscopy, ion-scattering spectroscopy, electron-stimulated desorption, residual-gas analysis, auger electron spectroscopy, x-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, characteristic-electron energy-loss spectroscopy, scanning electron microscope, scanning low-energy electron probe. Quadruple mass spectrometer, used in first 4 tests, serves as electron transfer lens in last 6 tests.

Grunthaner, F. J.↗

Two devices for analysis of nystagmus

Electromechanical Slope Computer /ESC/ and Electronic Summation Device /ESD/ facilitates rapid analysis of nystagmus records. The ESC reads out the slope and time of each nystagmus wave form. The ESD provides much faster analysis than the ESC. It provides an immediate analog display and digital display of analyzed nystagmus.

Guedry, F. E., Jr.↗

A Predictive Bubble Point Pressure Model for Porous Liquid Acquisition Device Screens

This article presents a simplified model for porous screen channel liquid acquisition devices based on a maximum bubble point pressure method from Adamson and Gast (1997). To validate the model, three 304 stainless steel (325 × 2300, 450 × 2750, and 510 × 3600) mesh samples were tested in methanol, acetone, isopropyl alcohol, and water. Screen pores are estimated based on analysis from scanning electron microscopy, historical data, and current test data. Results show that the bubble point pressure is proportional to the surface tension of the fluid only when accounting for nonzero contact angles. The previous assumption that bubble point pressure scales inversely with effective pore diameter is shown to be invalid, as the second finest 450 × 2750 produced the highest bubble point of the three screens. The simplified bubble point model can be used to make predictions for any pure fluid when pore diameters are based on bubble point tests and not SEM analysis.

Liquid Acquisition Device↗

Research of Magnetospheric Physics Phenomena Using Sounding Rockets

A bibliography of approximately 25 papers is presented on the Electron Echo Experiments. The data analysis included an extensive study of the electron accelerator beam, detector data correlations with the electron beam injections, and the study of about 30 onboard detected echoes.

Steffen, J. E.↗