Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric power grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Offshore wind and wave energy can reduce total installed capacity required in zero-emissions grids

Abstract As the world races to decarbonize power systems to mitigate climate change, the body of research analyzing paths to zero emissions electricity grids has substantially grown. Although studies typically include commercially available technologies, few of them consider offshore wind and wave energy as contenders in future zero-emissions grids. Here, we model with high geographic resolution both offshore wind and wave energy as independent technologies with the possibility of collocation in a power system capacity expansion model of the Western Interconnection with zero emissions by 2050. In this work, we identify cost targets for offshore wind and wave energy to become cost effective, calculate a 17% reduction in total installed capacity by 2050 when offshore wind and wave energy are fully deployed, and show how curtailment, generation, and transmission change as offshore wind and wave energy deployment increase.

16 TIDAL AND WAVE POWER↗

Sequence-to-sequence neural networks for short-term electrical load forecasting in commercial office buildings

The U.S. power grid is transforming to become smarter, cleaner, and more effi- cient. This is leading to the addition of significant distributed variable renew- able generation. Due to the variable nature of renewable generation, the short- and long-term supply-demand imbalances are less predictable, and conventional approaches to mitigating the imbalance will not be efficient or cost-effective. To address this challenge, transactive control technologies have been proposed which balance energy generation and consumption with market activity and in- frastructural limitations. Transactive control requires the ability of individual end-use loads to express flexibility as a function of a transactive signal (e.g., price). Empirical gray- and black-box models have been widely used to express flexibility, and although these approaches are generally easy to construct and simple to use, they do not capture the non-linear behavior that some end-use loads represent . Machine learning approaches have been proposed to address this limitation. Although deep learning approaches for forecasting end-use loads have been explored, certain aspects of the application of deep models to load forecasting are not well understood. These aspects include how much training data is required, and how models should be structured and trained. To that end, this work explores how to approach applying deep recurrent neural networks to short-term electrical load forecasting with a case study of four commercial office buildings. We identify data requirements for training accurate models of whole building electricity use conditioned on outdoor temperature, provide insight into model hyperparameter sensitivity, and demonstrate how readily models can be generalized to unseen buildings.

Skomski, Elliott↗

Modeling Electric Vehicle Charging Load Using Origin-Destination Data

The accelerating adoption of electric vehicles (EVs) poses challenges to the power grid, necessitating precise representation of mobility patterns for effective infrastructure upgrades. Traditional simulation-based charging demand estimation faces limitations in generating trip chains reflective of actual travel patterns without complex network modeling. Hence, an innovative agent-based trip chain generation model is introduced to overcome these challenges. Drawing from the National Household Travel Survey (NHTS) and the NextGen NHTS origin-destination add-on data for Clarke County, Georgia, this study proposes a simulation method capturing both temporal and spatial mobility patterns without relying on extensive network topology data. The resulting trip chains predict EV charging load at the Census Block Group level, validated with a 1.03 correlation to actual trip counts, affirming their reflective accuracy. Two charging scenarios, residential-only and charging-everywhere, reveal distinct demand profiles. The charging-everywhere scenario aligns closely with the trip profile, while the residential-only scenario exhibits an afternoon peak slightly surpassing the former. This study contributes a data-driven charging demand estimation methodology, offering critical insights for grid resiliency planning amid the evolving landscape of EV adoption.

Pan, Melrose↗

Expert Elicitation on Wind Farm Control

Wind farm control is an active and growing field of research in which the control actions of individual turbines in a farm are coordinated, accounting for inter-turbine aerodynamic interaction, to improve the overall performance of the wind farm and to reduce costs. The primary objectives of wind farm control include increasing power production, reducing turbine loads, and providing electricity grid support services. Additional objectives include improving reliability or reducing external impacts to the environment and communities. In 2019, a European research project (FarmConners) was started with the main goal of providing an overview of the state-of-the-art in wind farm control, identifying consensus of research findings, data sets, and best practices, providing a summary of the main research challenges, and establishing a roadmap on how to address these challenges. Complementary to the FarmConners project, an IEA Wind Topical Expert Meeting (TEM) and two rounds of surveys among experts were performed. From these events we can clearly identify an interest in more public validation campaigns. Additionally, a deeper understanding of the mechanical loads and the uncertainties concerning the effectiveness of wind farm control are considered two major research gaps.

17 WIND ENERGY↗

Regional Inertia Estimation Using Actual Event Measurements: Florida Case

As inverter-based resources’ integration in power grids increases, their uneven distribution across the electrical network leads to the formation of local regions that are weakly coupled to the larger interconnection. This signifies the necessity of regional frequency dynamics investigation and analyzing various inertia metrics. This paper presents a practical methodology for estimating regional rate-of-change of frequency (RoCoF) using actual event recordings, which is then used to evaluate regional inertia. Florida (FL) is selected as the region of interest due to its distinct regional frequency dynamics and the rising levels of solar generation. We identify and analyze confirmed events from 2017 to 2024 that occurred in FL. The results indicate that FL contributes about 14% to the total inertia of the US Eastern Interconnection, which approximately matches its share of generation capacity. Results also highlight seasonal fluctuations in energy generation, which play a significant role in influencing inertia and thus the RoCoF levels. This emphasizes the importance of estimating regional inertia to enhance grid operations for a future that focuses on distributed generation.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Deer Park Energy Center Natural Gas Combined Cycle Carbon Capture System Front-End Engineering Design Study (Final Scientific/Technical Report – Unlimited)

Calpine Texas CCUS Holdings, LLC (Calpine), Shell Catalysts & Technologies (SCT), Technip Energies (TEN), and Sargent & Lundy, LLC (S&L) have conducted a Front-End Engineering Design (FEED) Study to integrate a new carbon capture system at Calpine’s Deer Park Energy Center (DKEC). The DKEC facility is a nominal 1200 MW gas-fired co-generation power plant situated at the Shell Chemical Manufacturing (Shell) Facility located in Deer Park, Texas. Steam is produced for use by the adjacent Shell Chemical Manufacturing Facility as well as by the onsite steam turbine for electrical generation. The power output from DKEC is provided to the Electric Reliability Council of Texas (ERCOT) operated power grid. DKEC provides power to industrial and commercial customers via this interconnection.

03 NATURAL GAS↗

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2023

A summary of NREL's good stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, infrastructure and capability upgrades, and examples of R&D impact. In fiscal year 2023, ESIF installed its third-generation high-performance computer, expanded capabailities for validating building energy controls, and demonstrated a leap in scale through virtual networking with another national laboratory. ESIF researchers made breakthroughs in cybersecurity for energy systems, efficient high-powered electric vehicle charging, leveraging reinforcement learning for grid resilience, and more.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Evaluating Impacts of Sustainable Aviation Fuel Production with CO2-to-Fuels Technologies on High Renewable Share Power Grid: Preprint

This paper investigates the impact of Sustainable Aviation Fuel (SAF) production using CO2-to-Fuels technologies on a future power grid with a high share of renewable energy. We focus on understanding the implications of the 2050 SAF production goal on the U.S. power system's long-term planning, encompassing generation, transmission, and cost analysis. Via the Regional Energy Deployment System (ReEDS) model, we developed a detailed SAF electricity demand model based on a low-temperature electrolysis-syngas fermentation-ethanol pathway. Four SAF target scenarios which aimto meet 10%, 15%, 20%, and 27% of SAF demand by 2050. These scenarios are exhaustively simulated to assess their impact on the power grid. Our results reveal that increasing SAF demand will result in higher electricity requirements, as well as expanded generator and transmission capacities, leading to an overall rise in system costs. However, these impacts are manageable within the broader context of U.S. capacity expansion plans. This study provides valuable insights into incorporating the CO2-to-Fuels electricity demand model and other carbon capture technologies into power system planning, emphasizing their significance in shaping a sustainable energy future.

BIOMASS FUELS,ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancing Local Grid Resilience with Small Hydropower Hybrids: Proving the concept through demonstration, simulation, and analysis with Idaho Falls Power

Large hydropower, connected to the transmission system and typically possessing significant ability to balance grid frequency, has long been central to black start plans in regions where it is present. Small hydropower possesses most of the attributes required for black start but is often connected to distribution or sub-transmission systems and has less ability to balance grid frequency. Integrating energy storage such as batteries or ultracapacitors increases the combined asset’s ability to balance frequency. This asset integration enables a bottom-up grid restoration paradigm in which critical electric loads on the local distribution system can be powered even when the regional transmission system is down. This report presents a field demonstration conducted with Idaho Falls Power that proved this concept. The contribution of energy storage in restoring the small hydro-dominated distribution grid and its operational sensitivity across different control settings are further analyzed using high-fidelity simulations. Readers will learn about technical details on the field demonstration setup, energy storage contribution to black start, detailed simulation steps of islanded distribution grid restoration, and usage of field demonstration measurements for transient model refinements. Collectively this report points to a great opportunity for small hydropower to enhance resilience of local electric grids.

13 HYDRO ENERGY↗

Evaluating Impacts of Sustainable Aviation Fuel Production with CO2-to-Fuels Technologies on High Renewable Share Power Grids

This paper investigates the impact of Sustainable Aviation Fuel production using CO2-to-Fuels technologies on a future power grid with a high share of renewable energy. We focus on understanding the implications of the 2050 SAF production goal on the U.S. power system's long-term planning, encompassing generation, transmission, and cost analysis. Via the Regional Energy Deployment System (ReEDS) model, we developed a detailed SAF electricity demand model based on a low-temperature electrolysis-syngas fermentation-ethanol pathway. Four SAF target scenarios which aims to meet 10%, 15%, 20%, and 27% of SAF demand by 2050. These scenarios are exhaustively simulated to assess their impact on the power grid. Our results reveal that increasing SAF demand will result in higher electricity requirements, as well as expanded generator and transmission capacities, leading to an overall rise in system costs. However, these impacts are manageable within the broader context of U.S. capacity expansion plans. This study provides valuable insights into incorporating the CO2-to-Fuels electricity demand model and other carbon capture technologies in power system planning, emphasizing their significance in shaping a sustainable energy future.

BIOMASS FUELS,POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Impacts of Sustainable Aviation Fuel Production with CO2-to-Fuels Technologies on High Renewable Share Power Grid

This paper investigates the impact of Sustainable Aviation Fuel (SAF) production using CO 2 -to-Fuels technologies on a future power grid with a high share of renewable energy. We focus on understanding the implications of the 2050 SAF production goal on the U.S. power system's long-term planning, encompassing generation, transmission, and cost analysis. Via the Regional Energy Deployment System (ReEDS) model, we developed a detailed SAF electricity demand model based on a low-temperature electrolysis-syngas fermentation-ethanol pathway. Four SAF target scenarios which aim to meet 10%, 15%, 20%, and 27% of SAF demand by 2050. These scenarios are exhaustively simulated to assess their impact on the power grid. Our results reveal that increasing SAF demand will result in higher electricity requirements, as well as expanded generator and transmission capacities, leading to an overall rise in system costs. However, these impacts are manageable within the broader context of U.S. capacity expansion plans. This study provides valuable insights into incorporating the CO 2 -to-Fuels electricity demand model and other carbon capture technologies into power system planning, emphasizing their significance in shaping a sustainable energy future.

capacity expansion model↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Speed Medium Voltage CHP System with Advanced Grid Support

The project was a collaboration between Clemson University and TECO Westinghouse Motor Company. The goal of the project was to develop a medium voltage commercial grid-tied system with advanced grid support functions. Current state-of-the-art in medium voltage, multi-megawatt power electronic systems do not support advanced grid functions, traditionally due to power electronic limitations and required applications. The developed system is capable of interacting with the power system at the distribution level to efficiently integrate gas turbine generation systems or any other ac generation system with up to 20MWe of power production capacity. This project demonstrated a high level of technical readiness of the 1MW, 500Hz, 15000 RPM high frequency Combined Heat and Power (CHP) generator and electric machine system, utilizing advanced grid support functions required by IEEE Std. 1547-2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Cost Radiant Heater for Rapid Response, High-Temperature Heating

High-temperature processing has an irreplaceable role in many research and industrial applications. Despite remarkable development spanning over a century, the pursuit of even higher thermal flux density and more rapid thermal transients has not slowed down. As part of the ongoing energy evolution, many industrial applications are transitioning from direct combustion of fossil fuels as primary energy sources to increasing electrification, capable of adapting to renewable power grids. Thus, there is an emerging need for electrical heaters that can replace burners and supply the heat demand, especially at the highest temperatures. In this study, we report on a radiant heater design that can achieve cyclic heating/cooling rates of up to 400 K min –1 and a temperature range in excess of 1,800 K, comparable to those of commercial infrared gold image furnaces, at high surface and volumetric power densities. The heater consists of a modular unit of incandescent tungsten filament and is enclosed in an evacuated ceramic envelope, chemically inert, tolerant of thermal shock, and impervious to gasses. The material and manufacture cost of such heaters, which is estimated at ~$0.05/W, is less than 0.03% of that for infrared gold image furnaces, which is at >$2/W. Tests of more than 10,000 demanding cycles (high temperature and high heating/cooling rate) over 350 h of total operational time and in different temperature ranges confirm the robust performance of radiant heater prototypes. The design is widely applicable to high-temperature reactor and furnace designs. In thermochemistry research and practice, these radiant heaters could offer multiple benefits compared to solar simulators, lasers, infrared gold furnaces, ceramic heaters, or direct concentration of solar input.

99 GENERAL AND MISCELLANEOUS↗

Solar house system interfaced with the power utility grid

Photovoltaic cells may be used to convert sunlight directly into electrical energy and into low-grade heat to be used for large scale terrestrial solar energy conversion. Both forms of energy can be utilized if such cells are deployed in close proximity to the consumer (rooftop). CdS/Cu2S solar cells are an example of cells which may be produced inexpensively enough to become economically attractive. Cell parameters relevant for combined solar conversion are presented. Critical issues, such as production yield, life expectancy, stability of performance, are discussed. Systems design parameters related to operating temperatures are analyzed. First results obtained on Solar One, the experimental solar house of the University of Delaware, are given. Economic aspects are discussed.

Boeer, K. W.↗

Life cycle greenhouse gas emissions of different CO 2 supply options for an algal biorefinery

This paper characterizes the greenhouse gas (GHG) emissions from the provision of CO 2 for twelve hours of the day from a range of sources operating on a twenty-four-hour basis. Twelve CO 2 supply cases spanning from fossil fuel power plant stack gases to direct air capture (DAC) systems are modeled. The results are compared in a life cycle assessment (LCA) framework. The CO 2 supply from the combustion or gasification of biomass has GHG emissions of –1.62 gCO 2 eq./g CO 2 delivered and is the case with the lowest carbon footprint for supplied CO2. The emissions for all the CO 2 supply cases were found to be negative, either because of capturing more CO 2 from the atmosphere than is released from the CO 2 production process, or because of production of excess electricity that is exported to the grid (replacing emissions from grid electricity). A purpose-built Natural Gas Combined Cycle (NGCC) power plant CO 2 source has the highest GHG emissions of -0.40 gCO 2 eq./gCO 2 delivered of the cases considered because of nighttime emissions and natural gas supply chain losses. The impact of a diurnal cycle can be mitigated by using capture and refrigeration systems as part of the CO 2 management system. The results are sensitive to the GHG emissions of the grid electricity, which is imported or exported in different cases. The results provide a benchmark for the comparison of different CO 2 supply options for the establishment of a sustainable algal biorefinery.

42 ENGINEERING↗

Cybersecurity Lessons Learned from Vehicle to Grid Engagement

As the transportation industry continues to become electrified, introduction of additional digital devices within associated actions such as recharging bring additional potential for cybersecurity attacks. Devices that are designed, implemented, and operated with cybersecurity as a crucial consideration exacerbate these concerns by failing to provide strict boundaries on access to and use of the equipment. Emerging use cases such as Vehicle to Grid (V2G) charging may expand the potential physical effects of a cybersecurity attack by providing indirect access to electrical components of a building microgrid or portions of the larger power grid. This paper serves as an overview of findings and recommendations based on cybersecurity testing performed at a V2G implementation site operated by a member of the Memorandum of Understanding (MOU) to Establish the Vehicle-to-Everything (V2X) Collaboration [1]. The Department of Energy Office of Cybersecurity, Energy Security, and Emergency Response is a signatory of the MOU, and has funded this research paper and associated body of work regarding V2X cybersecurity. Sandia has a large background of previous research focused on Electric Vehicle (EV) cybersecurity, such as reference [2], which includes an overall survey of EV infrastructure cybersecurity and recommendations based on those findings. This report seeks to expand knowledge of EV cybersecurity status and needs by focusing on a specific implementation of V2G charging, and providing recommendations based on the relevant findings. This report serves as a publicly available, sanitized description of applied vulnerability testing on an operational V2G implementation. A more in-depth technical version of the report is provided to the MOU partner, but not available at the time of writing due to inclusion of proprietary information. V2G charging comes with many research problems that must be solved before the technology can securely implemented in sites with unrestricted public access or where cybersecurity attacks could have increased consequences, such as government offices. V2G charging requires many stakeholders such as end users, host sites, equipment vendors, and integrators, which all rely on operational safety and security as well as security and trustworthiness of any associated financial transactions.

33 ADVANCED PROPULSION SYSTEMS↗