Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Vertical Drop Testing and Analysis of the Wasp Helicopter Skid Gear

This report describes an experimental program to assess the impact performance of a skid gear for use on the Wasp kit-built helicopter, which is marketed by HeloWerks, Inc. of Hampton, Virginia. In total, five vertical drop tests were performed. The test article consisted of a skid gear mounted beneath a steel plate. A seating platform was attached to the upper surface of the steel plate, and two 95th percentile Hybrid III male Anthropomorphic Test Devices (ATDs) were seated on the platform and secured using a four-point restraint system. The test article also included ballast weights to ensure the correct position of the Center-of-Gravity (CG). Twenty-six channels of acceleration data were collected per test at 50,000 samples per second. The five drop tests were conducted on two different gear configurations. The details of these test programs are presented, as well as an occupant injury assessment. Finally, a finite element model of the skid gear test article was developed for execution in LS-DYNA, an explicit nonlinear transient dynamic code, for predicting the skid gear and occupant dynamic responses due to impact.

Jackson, Karen E.↗

Air Flow and Pressure Drop Measurements Across Porous Oxides

This report summarizes the results of air flow tests across eight porous, open cell ceramic oxide samples. During ceramic specimen processing, the porosity was formed using the sacrificial template technique, with two different sizes of polystyrene beads used for the template. The samples were initially supplied with thicknesses ranging from 0.14 to 0.20 in. (0.35 to 0.50 cm) and nonuniform backside morphology (some areas dense, some porous). Samples were therefore ground to a thickness of 0.12 to 0.14 in. (0.30 to 0.35 cm) using dry 120 grit SiC paper. Pressure drop versus air flow is reported. Comparisons of samples with thickness variations are made, as are pressure drop estimates. As the density of the ceramic material increases the maximum corrected flow decreases rapidly. Future sample sets should be supplied with samples of similar thickness and having uniform surface morphology. This would allow a more consistent determination of air flow versus processing parameters and the resulting porosity size and distribution.

Fox, Dennis S.↗

Statistical Model of Evaporating Multicomponent Fuel Drops

An improved statistical model has been developed to describe the chemical composition of an evaporating multicomponent- liquid drop and of the mixture of gases surrounding the drop. The model is intended for use in computational simulations of the evaporation and combustion of sprayed liquid fuels, which are typically mixtures of as many as hundreds of different hydrocarbon compounds. The present statistical model is an approximation designed to afford results that are accurate enough to contribute to understanding of the simulated physical and chemical phenomena, without imposing an unduly large computational burden.

Harstad, Kenneth↗

Optical Characterization of a Multipoint Lean Direct Injector for Gas Turbine Combustors: Velocity and Fuel Drop Size Measurements

Performance of a multipoint, lean direct injection (MP-LDI) strategy for low emission aero-propulsion systems has been tested in a Jet-A fueled, lean flame tube combustion rig. Operating conditions for the series of tests included inlet air temperatures between 672 and 828 K, pressures between 1034 and 1379 kPa and total equivalence ratios between 0.41 and 0.45, resulting in equilibrium flame temperatures approaching 1800 K. Ranges of operation were selected to represent the spectrum of subsonic and supersonic flight conditions projected for the next-generation of commercial aircraft. This document reports laser-based measurements of in situ fuel velocities and fuel drop sizes for the NASA 9-point LDI hardware arranged in a 3 3 square grid configuration. Data obtained represent a region of the flame tube combustor with optical access that extends 38.1-mm downstream of the fuel injection site. All data were obtained within reacting flows, without particle seeding. Two diagnostic methods were employed to evaluate the resulting flow path. Three-component velocity fields have been captured using phase Doppler interferometry (PDI), and two-component velocity distributions using planar particle image velocimetry (PIV). Data from these techniques have also offered insight into fuel drop size and distribution, fuel injector spray angle and pattern, turbulence intensity, degree of vaporization and extent of reaction. This research serves to characterize operation of the baseline NASA 9- point LDI strategy for potential use in future gas-turbine combustor applications. An additional motive is the compilation of a comprehensive database to facilitate understanding of combustor fuel injector aerodynamics and fuel vaporization processes, which in turn may be used to validate computational fluid dynamics codes, such as the National Combustor Code (NCC), among others.

Heath, Christopher M.↗

A Framework for the Generation and Dissemination of Drop Size Distribution (DSD) Characteristics Using Multiple Platforms

Proper characterization of the precipitation drop size distribution (DSD) is integral to providing realistic and accurate space- and ground-based precipitation retrievals. Current technology allows for the development of DSD products from a variety of platforms, including disdrometers, vertical profilers and dual-polarization radars. Up to now, however, the dissemination or availability of such products has been limited to individual sites and/or field campaigns, in a variety of formats, often using inconsistent algorithms for computing the integral DSD parameters, such as the median- and mass-weighted drop diameter, total number concentration, liquid water content, rain rate, etc. We propose to develop a framework for the generation and dissemination of DSD characteristic products using a unified structure, capable of handling the myriad collection of disdrometers, profilers, and dual-polarization radar data currently available and to be collected during several upcoming GPM Ground Validation field campaigns. This DSD super-structure paradigm is an adaptation of the radar super-structure developed for NASA s Radar Software Library (RSL) and RSL_in_IDL. The goal is to provide the DSD products in a well-documented format, most likely NetCDF, along with tools to ingest and analyze the products. In so doing, we can develop a robust archive of DSD products from multiple sites and platforms, which should greatly benefit the development and validation of precipitation retrieval algorithms for GPM and other precipitation missions. An outline of this proposed framework will be provided as well as a discussion of the algorithms used to calculate the DSD parameters.

Wolf, David B.↗

Drop Size Distribution Measurements Supporting the NASA Global Precipitation Measurement Mission: Infrastructure and Preliminary Results

Global Precipitation Measurement Mission (GPM) retrieval algorithm validation requires datasets that characterize the 4-D structure, variability, and correlation properties of hydrometeor particle size distributions (PSD) and accumulations over satellite fields of view (5 -- 50 km). Key to this process is the combined use of disdrometer and polarimetric radar platforms. Here the disdrometer measurements serve as a reference for up-scaling dual-polarimetric radar observations of the PSD to the much larger volumetric sampling domain of the radar. The PSD observations thus derived provide a much larger data set for assessing DSD variability, and satellite-based precipitation retrieval algorithm assumptions, in all three spatial dimensions for a range of storm types and seasons. As one component of this effort, the GPM Ground Validation program recently acquired five 3rd generation 2D Video disdrometers as part of its Disdrometer and Radar Observations of Precipitation Facility (DROP), currently hosted in northern Alabama by the NASA Marshall Space Flight Center and the University of Alabama in Huntsville. These next-generation 2DVDs were operated and evaluated in different phases of data collection under the scanning domain of the UAH ARMOR C-band dual-polarimetric radar. During this period approximately 7500 minutes of PSD data were collected and processed to create gamma size distribution parameters using a truncated method of moments approach. After creating the gamma parameter datasets the DSDs were then used as input to T-matrix code for computation of polarimetric radar moments at C-band. The combined dataset was then analyzed with two basic objectives in mind: 1) the investigation of seasonal variability in the rain PSD parameters as observed by the 2DVDs; 2) the use of combined polarimetric moments and observed gamma distribution parameters in a functional form to retrieve PSD parameters in 4-D using the ARMOR radar for precipitation occurring in different seasons and for different rain system types. Preliminary results suggest that seasonal variations in the DSD parameters do occur, but are most pronounced when comparing tropical PSDs to either winter or summer convective precipitation. For example the previously documented shift to relatively smaller drop diameters in higher number concentrations for equivalent rain rate bins was observed in tropical storm rainbands occurring over Huntsville. On a more inter seasonal basis empirical fits between parameters such as D0 and ZDR do not appear to exhibit robust seasonal biases- i.e., one fit seems to work for all seasons within acceptable standard error (O[10%]) for estimates of D0. In polarimetric retrievals of the vertical variability in PSD (rain layer) for a tropical rainband we find that the Do varies with height when partitioned by specified precipitation categories (e.g., convective or stratiform, heavy and light stratiform etc.) but this variation is of order 10-20% and is smaller than the difference in D0 observed between the basic delineation of convective and stratiform precipitation types. Currently we are expanding our analysis of the vertical structure of the PSD to include several seasonally and/or dynamically-different storm system types (e.g., winter convection and stratiform events; summer mid-latitude convective etc.) sampled by ARMOR. The study will present the results of our combined analyses.

Petersen, Walter A.↗

DROP: Durable Reconnaissance and Observation Platform

Robots have been a valuable tool for providing a remote presence in areas that are either inaccessible or too dangerous for humans. Having a robot with a high degree of adaptability becomes crucial during such events. The adaptability that comes from high mobility and high durability greatly increases the potential uses of a robot in these situations, and therefore greatly increases its usefulness to humans. DROP is a lightweight robot that addresses these challenges with the capability to survive large impacts, carry a usable payload, and traverse a variety of surfaces, including climbing vertical surfaces like wood, stone, and concrete. The platform is crash-proof, allowing it to be deployed in ways including being dropped from an unmanned aerial vehicle or thrown from a large MSL-class (Mars Science Laboratory) rover.

Parness, Aaron↗

Structure and Dynamics of Interfaces: Drops and Films

We aim to acquire measurements of the structure and dynamics of certain liquid-fluid interfaces using an ensemble of techniques in collaboration: (1) Total internal reflection (TIR) Surface light scattering spectroscopy (SLSS), (2) Brewster angle microscopy (BAM), and (3) Drop-shape analysis. SLSS and BAM can be done on a shared interfacial footprint. Results using a 50-50 mixture of pentane-isohexane, which extends the range of NASA's Confined Vapor Bubble (CVB) experiment, yield surface tension results that differ from the expected Langmuir Fit. These results were confirmed using both the SLSS and drop-shape analysis approaches.

pentane-isohexane mixture↗

Electric Mars: A Large Trans-Terminator Electric Potential Drop on Closed Magnetic Field Lines Above Utopia Planitia

Abstract Parallel electric fields and their associated electric potential structures play a crucial role inionospheric-magnetospheric interactions at any planet. Although there is abundant evidence that parallel electric fields play key roles in Martian ionospheric outflow and auroral electron acceleration, the fields themselves are challenging to directly measure due to their relatively weak nature. Using measurements by the Solar Wind Electron Analyzer instrument aboard the NASA Mars Atmosphere and Volatile EvolutioN(MAVEN) Mars Scout, we present the discovery and measurement of a substantial (Phi) Mars 7.7 +/-0.6 V) parallel electric potential drop on closed magnetic field lines spanning the terminator from day to night above the great impact basin of Utopia Planitia, a region largely free of crustal magnetic fields. A survey of the previous 26 orbits passing over a range of longitudes revealed similar signatures on seven orbits, with a mean potential drop (Phi) Mars of 10.9 +/- 0.8 V, suggestive that although trans-terminator electric fields of comparable strength are not ubiquitous, they may be common, at least at these northerly latitudes.

Magnetic↗

International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Drop Testing of Returned Units

The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality↗

Full-Scale Drop Test of a Fokker F28 Wingbox Fuselage Section

During the summer of 2017, a vertical drop test was conducted on a partial section of a Fokker F28 MK4000 aircraft as a part of a joint NASA/FAA effort to investigate the performance of transport category aircraft under realistic crash conditions. Ten Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) ranging from 5th to 95th percentile sizes were used for the collection and comparison of occupant loads. Additionally, overhead bin mass simulators were added to achieve a realistic fuselage configuration. The section was dropped with a downward facing pitch angle onto a sloping soil surface in order to simulate a local horizontal velocity in the airframe. Instrumentation consisting of accelerometers was installed to measure floor, seat track, ATD, and overhead bin acceleration responses. Self-contained data recorders logging accelerations and rotational rates were also used on the seat tracks and lower structure as evaluations for crash recording devices in potential future use cases. The right side of the section was painted with a stochastic black and white speckle pattern for use in full field photogrammetric imaging techniques. Results collected from the airframe accelerometers will be presented, and deformation and failures of the test article structure will be discussed. Finally, an examination of the test article motion will be presented using derived components of local velocities with their effect on the impact acceleration and airframe response.

Littell, J. D.↗

Vertical Drop Test and Simulation of a Fokker F-28 Fuselage Section

In March 2017, a vertical drop test of a 3.048-m(10-ft) section of a Fokker F-28 aircraft was conducted as a part of a joint NASA/FAA effort to investigate the performance of transport aircraft under realistic crash conditions. The section was configured with two rows of aircraft seats, in a triple-double configuration. A total of ten Anthropomorphic Test Devices (ATDs) were secured in the seats using standard seat belt restraints. The section was also configured with luggage in the cargo hold. Two hat racks were added, each with mass loading of 37.2-kg per linear meter (25-lb/ft). The drop test was performed at the Landing and Impact Research facility located at NASA Langley Research Center in Hampton, Virginia. The planned impact velocity was 9.144-m/s (360-in/s) onto soil. A second objective was to assess the capabilities of finite element simulations to predict the test response. A finite element model was developed for execution in LS-DYNA, a commercial explicit nonlinear transient dynamic code. The model contained accurate representations of the airframe structure, the hat racks and hat rack masses, the floor and seat tracks, and the luggage in the cargo hold. Concentrated masses were used to represent the inertial properties of the seats, restraints, and ATD occupants. The model was executed to generate analytical predictions of airframe responses, which were compared with test data to validate the model.

Jackson, K. E.↗

Microgravity Liquid-Gas Two-Phase Flow: Review of Pressure Drop and Heat Transfer Correlations and Guidelines for Equipment Operability

In this report we have catalogued the flow regimes observed in microgravity, summarized correlations for the pressure drop and rate of heat transfer that are commonly used, and discuss the validation of a few correlations from available experimental results. Two-phase flow through some specific components such as bends, tees, filters and pumps are discussed from a physical perspective to guide the designer on how reduced gravity might affect their performance. Phase separation in zero gravity is addressed through the behavior and basic design concepts for devices based on passive centrifugal action, capillary forces, gas extraction through a membrane installed in a channel wall and the use of a syringe with a perforated piston to remove bubbles from small liquid volumes. We address the common instabilities that develop in flow loops owing exclusively to the two-phase nature of the flow, e.g., Ledinegg instability and concentration waves. Finally we briefly review flow metering and gauging; two-phase flow through porous media, where pressure drop and flow regime map correlations in zero-g are a current research topic; and basic operation principles of heat pipes and capillary pumped loops.

liquid-gas↗

CFD Modeling of Phase Change and Pressure Drop during Violent Sloshing of Cryogenic Fluid in a Small-Scale Tank

This paper presents the development of a two-phase CFD model that is used to study sloshing of a cryogenic fluid (LN2) undergoing phase change generated by lateral acceleration and its effects on the ensuing heat and mass transfer and pressure drop in a small-scale tank. In this model the interface is captured using the volume-of-fluid (VOF) method [1]. Kinetic-theory based Schrage relation [2] is used for calculating phase change mass transfer at the liquid-vapor interface. Computational results are compared to the data provided by a non-isothermal sloshing experiment with phase change conducted by the University of Tokyo and JAXA in 2018 using liquid Nitrogen in a transparent tank. The effect of different thicknesses of a liquid temperature stratification layer created at the interface on the pressure drop during sloshing was studied experimentally. CFD results for interface movement and tank pressure are presented and compared in this paper to experimental data for the cases with the smallest and largest liquid temperature stratification thickness.

phase change↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15µm to 460 µm. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

Icing cloud instruments↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15m to 460 m. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15um to 460 um. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗