Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A preliminary investigation of bird classification by Doppler radar

A preliminary study of the application of Doppler radar to the classification of birds is reported. The desirability for improvements in bird classification stems primarily from the hazards they present to jet aircraft in flight and in the vicinity of airports. A secondary need exists in the study of bird migration. The wing body and tail motion of a bird in flight reflect signals which, when analyzed properly present a signature of wing beat pattern which is unique for each bird species. Although the results of this investigation did not validate the feasibility of classifying bird species, they do indicate that a more thorough investigation is warranted. Certain gross characteristics such as wing beat rates, multiple bird patterns, and bird maneuverability, were indicated clearly in the results. Large birds with slow wing beat rates appear to be the most optimum subject for further study with the X-band Doppler radar used in this investigation.

Martinson, L. W.↗

Doppler shift system

A system is described for measuring velocities of radiating particles based on Doppler shift. Light from the particles is directed through a narrow band optical filter to a Fabry-Perot interferometer initially tuned to a selected center line corresponding to zero particle Doppler shift. The movable mirror of the interferometer is made to sweep about the center line by the output of a modulation oscillator. The fringe pattern output is imaged onto a pin hole through which light is directed to a photomultiplier. The output of the photomultiplier is supplied to a phase sensitive detector with the oscillator output as a reference signal and which operates in the quadrature mode. The detector's output is gain controlled and is combined with the oscillator's output to adjust the interferometer's movable mirror to acquire the line center.

Aisenberg, S.↗

Laser Doppler velocimeter measurements in a turbine stator cascade facility

A laser Doppler velocimeter (LDV) developed for mapping the flow velocity downstream from a 32-inch diameter annular cascade of turbine stator vanes in described. The LDV measurements were taken in a plane located approximately 0.5 inch downstream of the trailing edges of the vanes. Two components of the mean velocity (axial and circumferential) were measured. The flow velocities were in the high subsonic range. The LDV optics are of the dual scatter type with off-axis collection of the scattered light. The electronics system is based on the measurement of the time interval corresponding to eight periods of the Doppler signal and has a range of 10 to 80 MHz. The LDV measurements are compared with previous measurements made with a pressure probe.

Seasholtz, R. G.↗

Fluid dynamic studies on scattering aerosol and its generation for application as tracer particles in supersonic flow measurements utilizing laser Doppler velocimeter

An experimental study on the particle-fluid interactions of scattering aerosols was performed using monodisperse aerosols of different particle sizes for the application of laser Doppler velocimeters in subsonic turbulence measurements. Particle response was measured by subjecting the particles to an acoustically excited oscillatory fluid velocity field and by comparing the ratio of particle velocity amplitude to the fluid velocity amplitude as a function of particle size and the frequency of oscillation. Particle velocity was measured by using a differential laser Doppler velocimeter. The test aerosols were fairly monodisperse with a mean diameter that could be controlled over the size range from 0.1 to 1.0 micron. Experimental results on the generation of a fairly monodisperse aerosol of solid particles and liquid droplets and on the aerosol response in the frequency range 100 Hz to 100 kHz are presented. It is indicated that a unit density spherical scatterer of 0.3 micron-diameter would be an optimum choice as tracer particles for subsonic air turbulence measurements.

Mazumder, M. K.↗

Ultrasonic Doppler measurement of renal artery blood flow

Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

Source record↗

Development and testing of laser Doppler system components for wake vortex monitoring. Volume 1: Scanner development, laboratory and field testing and system modeling

A servo-controlled range/elevation scanner for the laser Doppler velocimeter (LDV) was developed and tested in the field to assess its performance in detecting and monitoring aircraft trailing vortices in an airport environment. The elevation scanner provides a capability to manually point the LDV telescope at operator chosen angles from 3.2 deg. to 89.6 deg within 0.2 deg, or to automatically scan the units between operator chosen limits at operator chosen rates of 0.1 Hz to 0.5 Hz. The range scanner provides a capability to manually adjust the focal point of the system from a range of 32 meters to a range of 896 meters under operator control, or to scan between operator chosen limits and at rates from 0.1 Hz to 6.9 Hz. The scanner controls are designed to allow simulataneous range and elevation scanning so as to provide finger scan patterns, arc scan patterns, and vertical line scan patterns. The development and testing of the unit is discussed, along with a fluid dynamic model of the wake vortex developed in a laser Doppler vortex sensor simulation program.

Wilson, D. J.↗

Pipe flow measurements of turbulence and ambiguity using laser-Doppler velocimetry

The laser-Doppler ambiguities predicted by George and Lumley (1973) have been verified experimentally for turbulent pipe flows. Experiments were performed at Reynolds numbers from 5000 to 15,000 at the center line and near the wall. Ambiguity levels were measured from power spectral densities of FM demodulated laser signals and were compared with calculations based on the theory. The turbulent spectra for these water flows after accounting for the ambiguity were equivalent to hot-film measurements at similar Reynolds numbers. The feasibility of laser-Doppler measurements very close to the wall in shear flows is demonstrated.

Berman, N. S.↗

Doppler broadening effect on collision cross section functions - Deconvolution of the thermal averaging

The surprising feature of the Doppler problem in threshold determination is the 'amplification effect' of the target's thermal energy spread. The small thermal energy spread of the target molecules results in a large dispersion in relative kinetic energy. The Doppler broadening effect in connection with thermal energy beam experiments is discussed, and a procedure is recommended for the deconvolution of molecular scattering cross-section functions whose dominant dependence upon relative velocity is approximately that of the standard low-energy form.

Bernstein, R. B.↗

Laser Doppler velocimeter measurements in a turbine stator cascade facility

A laser Doppler velocimeter (LDV) developed for mapping the flow velocity downstream from a 32-inch diameter annular cascade of turbine stator vanes is described. The LDV measurements were taken in a plane located approximately 0.5 inch downstream of the trailing edges of the vanes. Two components of the mean velocity (axial and circumferential) were measured. The flow velocities were in the high subsonic range. The LDV optics are of the dual scatter type with off-axis collection of the scattered light. The electronics system is based on the measurement of the time interval corresponding to eight periods of the Doppler signal and has a range of 10 to 80 MHz. The LDV measurements are compared with previous measurements made with a pressure probe.

Seasholtz, R. G.↗

Laser Doppler velocimeter system simulation for sensing aircraft wake vortices

A hydrodynamic model of aircraft vortex wakes in an irregular wind shear field near the ground is developed and used as a basis for modeling the characteristics of a laser Doppler detection and vortex location system. The trailing vortex sheet and the wind shear are represented by discrete free vortices distributed over a two-dimensional grid. The time dependent hydrodynamic equations are solved by direct numerical integration in the Boussinesq approximation. The ground boundary is simulated by images, and fast Fourier Transform techniques are used to evaluate the vorticity stream function. The atmospheric turbulence was simulated by constructing specific realizations at time equal to zero, assuming that Kolmogoroff's law applies, and that the dissipation rate is constant throughout the flow field. The response of a simulated laser Doppler velocimeter is analyzed by simulating the signal return from the flow field as sensed by a simulation of the optical/electronic system.

Thomson, J. A. L.↗

Investigations of atmospheric dynamics using a CW Doppler sounder array

A three-dimensional CW Doppler sounding system currently under operation at the NASA-Marshall Space Flight Center, Alabama is described. The properties of the neutral atmosphere are discussed along with the theory of Doppler sounding technique. Methods of data analyses used to investigate the dynamical phenomena at the ionospheric heights are presented and suggestions for future investigations provided.

Rao, G. L.↗

Laser and acoustic Doppler techniques for the measurement of fluid velocities

An overview of current laser and acoustic Doppler techniques is presented. Results obtained by Doppler anemometry and conventional sensors are compared. Comparisons include simultaneous velocity measurements by hot wire and a three-dimensional laser anemometer made in a gaseous pipe flow as well as direct comparisons of atmospheric velocities measured with propeller and cup anemometry. Scanning techniques are also discussed. Conclusions and recommendations for future work are presented.

Cliff, W. C.↗

Multi-slit spectrograph and H alpha Doppler system

Description of the design and operation of a multiple-entrance-slit spectrograph, built for time-lapse photography of the spectra of flares and other transient solar phenomena. This spectrograph employs narrow-band filters to limit the wavelength range of the spectrograph to a few angstroms centered at H-alpha or other spectral lines. A polarizing beamsplitter, prior to the slits, provides a prefiltered second solar image to a narrow band H-alpha Doppler filter for simultaneous photography in the wings of the H-alpha line. The spectrograph and the H-alpha Doppler system constitute a flexible instrument in which components may be substituted to achieve different passband widths, image scales, dispersions, and corresponding numbers and spacings of adjacent spectra at a selected wavelength.

Martin, S. F.↗

Mars physical parameters as determined from Mariner 9 observations of the natural satellites and Doppler tracking

Mariner 9 Doppler tracking data and television photographs of Deimos and Phobos were analyzed to determine the gravity field, mass, and spin-axis direction of Mars and the natural satellite orbits. The solutions agree with previously published results. Radio data consisted of an apoapsis state vector for each of revolutions 5-195 obtained from one-revolution fits of Doppler data. Optical data consisted of TV photographs of Phobos and Deimos taken between revolutions 25 and 221. A first-order analytical theory, extended to include dominant second-order resonance effects on the Mariner 9 orbit, was used to calculate the motion of the spacecraft, Deimos, and Phobos. The feasibility of combining radio and optical data in long-arc solutions for accurate determination of orbits and physical parameters is demonstrated. The analytical theory developed for the evolution of a highly eccentric orbit in shallow resonance is accurate to plus or minus 1 km in the apoapsis state vector of Mariner 9 over a period of 200 revolutions.

Born, G. H.↗

Ionospheric S-shaped Doppler fluctuations produced by the tornadoes

A three-dimensional nine element HF-CW Doppler sounder array has been used to detect ionospheric disturbances which may be due to tornadoes. The typical events chosen in the present study occurred on November 20 and 27, 1973. Both events are apparently associated with tornadoes sighted in the Huntsville, Alabama area. The Doppler records show S-shaped waves rather than the quasi-sinusoidal waves observed in conjunction with and apparently due to thunderstorms. The wave-periods are in the range of 6 to 8 minutes instead of the 3 to 5 minute periods associated with thunderstorms. Dissipation of waves is mostly due to the evanescent effect and they cannot propagate very far from the path of the tornado center. A theory is presented which is in good agreement with the observations.

Hung, R. J.↗

CO2 laser doppler systems for the measurement of atmospheric winds and turbulence

Two CO2 laser doppler systems developed by NASA and some results obtained with them are discussed. A continuous wave, monostatic system for short-range wind measurement is described, and direct comparisons between the data obtained with it and with a cup-anemometer/wind vane system and a hot-wire anemometer show excellent agreement between the systems. Improvements being made in three CW, CO2 laser doppler systems, including a filter bank for optimized signal processing and a versatile scanning system, are noted. A pulsed CO2 system for measuring clear air turbulence is described, and results of test performance on board a Convair 990 are presented. It is noted that while the system was able to measure air speed and turbulence, the range of its transmitter-atmosphere-receiver was lower than predicted, and a difference of about 20 to 30 dB existed between the actual and theoretical turbulence measurements. Factors that may account for this loss are listed.

Huffaker, R. M.↗

Conceptual design of an airborne laser Doppler velocimeter system for studying wind fields associated with severe local storms

An airborne laser Doppler velocimeter was evaluated for diagnostics of the wind field associated with an isolated severe thunderstorm. Two scanning configurations were identified, one a long-range (out to 10-20 km) roughly horizontal plane mode intended to allow probing of the velocity field around the storm at the higher altitudes (4-10 km). The other is a shorter range (out to 1-3 km) mode in which a vertical or horizontal plane is scanned for velocity (and possibly turbulence), and is intended for diagnostics of the lower altitude region below the storm and in the out-flow region. It was concluded that aircraft flight velocities are high enough and severe storm lifetimes are long enough that a single airborne Doppler system, operating at a range of less than about 20 km, can view the storm area from two or more different aspects before the storm characteristics change appreciably.

Thomson, J. A. L.↗

Remote intensity fluctuation measurements with a laser Doppler radar

A coaxial focused CW scanning laser Doppler velocimeter (SLDV) radar equipment applying heterodyne detection at 10.6 microns can measure intensity fluctuations under field conditions. The set includes a 20 W CO2 laser, a coaxial Cassegrainian telescope, standard heterodyne equipment, and a SAW spectrum analyzer with 100 kHz signal resolution. Operation of the equipment and techniques for taking remote measurements are described briefly. Applications to remote measurements of transverse component of wind speed, as a complement to the traditional Doppler method of determining axial velocity, are under study. SLDV equipment has been used in detection, tracking, and measurements of atmospheric turbulence associated with aircraft wing-tip vortices or with dust devils, and in measurement of general atmospheric wind profiles.

Kennedy, L. Z.↗