Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Testing Low-Loss Microstrip Materials with MKIDs for Microwave Applications

Future measurements of the millimeter-wavelength sky require a low-loss superconducting microstrip, typically made from niobium and silicon-nitride, coupling the antenna to detectors. Here, we propose a simple device for characterizing these low-loss microstrips at 150 GHz. In our device we illuminate an antenna with a thermal source and compare the measured power at 150 GHz transmitted down microstrips of different lengths. The power measurement is made using Microwave Kinetic Inductance Detectors (MKIDs) fabricated directly onto the microstrip dielectric, and comparing the measured response provides a direct measurement of the microstrip loss. Our proposed structure provides a simple device (4 layers and a DRIE etch) for characterizing the dielectric loss of various microstrip materials and substrates. We present initial results using these devices. We demonstrate that the millimeter wavelength loss of microstrip lines, a few tens of millimeters long, can be measured using a practical aluminum MKID with a black body source at a few tens of Kelvin.

47 OTHER INSTRUMENTATION↗

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Engineering of Lead Selenide Quantum Dot Based Devices and Core/Shell Heterostructures

Near infrared (NIR) emitting colloidal quantum dots (QDs) such as PbSe are interesting materials for implementation in various optoelectronic devices such as solar cells, photodetectors, and radiation detectors. Material properties like size tunable emission wavelengths, facile solution processability, the possibility of carrier multiplication and Auger assisted up-conversion, and high Z number provide PbSe QDs with unique advantages over many currently available commercial materials used in these devices. In this dissertation, after an introduction to QDs in general, we first focus on synthesis of PbSe-based heterostructured QDs for study via optical spectroscopy. PbSe/CdSe QDs synthesized via cation exchange reaction were used as seeds to study the proper conditions for further CdSe or CdS shell growth. Optical spectroscopy studies show that growth of thicker CdSe shells leads to tunable visible emission, while growth of thick CdS shells can greatly increase the photoluminescence quantum yield (PLQY) observed from the intermediate CdSe shell. NIR PL lifetimes can be greatly enhanced by the growth of CdS shells, due to strong delocalization of the hole wavefunction within the PbSe core, while the electron is delocalized throughout the QD including in the CdS shell, resulting in radiative lifetimes in the tens of microseconds. Two pulse delay measurements show that Auger assisted up conversion is also taking place in these engineered QD dot heterostructures. In the sections that follow, we look at QD devices, first with a focus on novel devices fabricated from PbSe QDs, using an amine synthesis method that allows for facile in-solution ligand exchange. QD film mobilities are measured for PbSe QDs capped with various short ionic ligands. Carrier densities in PbSe QD films are calculated from C-V measurements, showing for the first time that carrier densities can be modulated by simply changing the capping ligand. vii Radiation detectors utilizing PbSe QDs capped with KI and NH4I ligands show tangible response to incident alpha radiation. Current output response to alpha radiation is dependent on strength of radiation source and amount of bias voltage applied. In the final section a critical review of hybrid layered 2D-QD photodetectors is presented. In a typical example, PbSe and PbS QDs act as the absorbing layer in phototransistor devices which utilize layered 2D materials such as graphene and transition metal dichalcogenides as transport layers. Resulting devices display high gains and improved directivities compared to QD only and 2D only devices.

36 MATERIALS SCIENCE↗

TP89 - SIRZ Decomposition Spectral Estimation (V.1.0)

The purpose of this test plan is to generate and evaluate calibrated system spectral response models for a dual-energy x-ray computed tomography (DECT) scanner. These spectral response models, which represent the energy distribution of photons observed by the detector with no test articles in the beam path, are necessary for spectral decomposition reconstruction techniques such as SIRZ, which are used for precise material characterization.

42 ENGINEERING↗

European Contributions to Fermilab Accelerator Upgrades and Facilities for the DUNE Experiment

The Proton Improvement Plan (PIP-II) to the FNAL accelerator chain and the Long-Baseline Neutrino Facility (LBNF) will provide the world's most intense neutrino beam to the Deep Underground Neutrino Experiment (DUNE) enabling a wide-ranging physics program. This document outlines the significant contributions made by European national laboratories and institutes towards realizing the first phase of the project with a 1.2 MW neutrino beam. Construction of this first phase is well underway. For DUNE Phase II, this will be closely followed by an upgrade of the beam power to > 2 MW, for which the European groups again have a key role and which will require the continued support of the European community for machine aspects of neutrino physics. Beyond the neutrino beam aspects, LBNF is also responsible for providing unique infrastructure to install and operate the DUNE neutrino detectors at FNAL and at the Sanford Underground Research Facility (SURF). The cryostats for the first two Liquid Argon Time Projection Chamber detector modules at SURF, a contribution of CERN to LBNF, are central to the success of the ongoing execution of DUNE Phase I. Likewise, successful and timely procurement of cryostats for two additional detector modules at SURF will be critical to the success of DUNE Phase II and the overall physics program. The DUNE Collaboration is submitting four main contributions to the 2026 Update of the European Strategy for Particle Physics process. This paper is being submitted to the 'Accelerator technologies' and 'Projects and Large Experiments' streams. Additional inputs related to the DUNE science program, DUNE detector technologies and R&D, and DUNE software and computing, are also being submitted to other streams.

43 PARTICLE ACCELERATORS↗

3D Source Reconstruction Using Coded Aperture Gamma-Ray Imaging

Recent measurements with coded-aperture imagers demonstrate material mass determination in a holdup setting to an accuracy within a few percent. This capability is of particular interest to the Surplus Plutonium Disposition (SPD) project, which aims to dilute and dispose of surplus plutonium oxide. Gamma-ray imagers can be used to determine holdup without interrupting normal operations. In this work, we examine techniques for 3D source localization and mass determination using gamma-ray imagers. Coded-aperture imagers provide excellent source localization within the 2D image plane; however, multiple imagers operating in tandem are necessary to identify source location in 3D space. A Maximum Likelihood Expectation-Maximization (MLEM) method for fitting detector mappings is a powerful tool for accomplishing this task. MLEM allows 3D source localization to be simultaneously constrained using multiple gamma-ray imagers by constructing the basis for the MLEM fit using detector mappings from different detector locations stitched together. Each of these basis points represents a singular response from a source in 3D space and is generated using Monte Carlo simulations of sources placed individually at different locations throughout the imager’s field of view. Additionally, implementing knowledge of the physical equipment in the simulations of the glovebox used for the SPD project incorporates attenuation effects that are needed to calculate material holdup.

Laminack, Alex↗

Improving Detector Systematic Uncertainties Through Data-Driven Machine Learning

Detector simulation in liquid argon time projection chambers (LArTPCs) is a constant challenge. In particular the modeling of electrons response on wires is highly nontrivial. However, new machine learning techniques exist which can be leveraged to ameliorate these concerns. We present a novel methodology to attempt to learn from cosmic muon data in the ICARUS detector how reconstructed wire signals are influenced by features of the hits such as location, particle direction, angle relative to the wire plane, etc. A model can then be generated which can apply the learned mapping to Monte Carlo events to create a more data-like simulation sample. By creating such a sample we expect to reduce the systematic uncertainties at ICARUS due to our detector modeling.

Hausner, Harry [Fermilab] (ORCID:0000000188932280)↗

Improving Detector Systematic Uncertainties Through Data-Driven Machine Learning

Detector simulation in liquid argon time projection chambers (LArTPCs) is a constant challenge. In particular the modeling of electrons response on wires is highly nontrivial. However, new machine learning techniques exist which can be leveraged to ameliorate these concerns. We present a novel methodology to attempt to learn from cosmic muon data in the ICARUS detector how reconstructed wire signals are influenced by features of the hits such as location, particle direction, angle relative to the wire plane, etc. A model can then be generated which can apply the learned mapping to Monte Carlo events to create a more data-like simulation sample. By creating such a sample we expect to reduce the systematic uncertainties at ICARUS due to our detector modeling.

Hausner, Harry [Fermilab] (ORCID:0000000188932280)↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Modeling and Design of Photon Energy Attenuation Layers for >10× Quantum Yield Enhancement in Si-Based Hard X-ray Detectors

High-energy (>20 keV) X-ray photon detection at high quantum yield, high spatial resolution, and short response time has long been an important area of study in physics. Scintillation is a prevalent method but limited in various ways. Directly detecting high-energy X-ray photons has been a challenge to this day, mainly due to low photon-to-photoelectron conversion efficiencies. Commercially available state-of-the-art Si direct detection products such as the Si charge-coupled device (CCD) are inefficient for >10 keV photons. Here, we present Monte Carlo simulation results and analyses to introduce a highly effective yet simple high-energy X-ray detection concept with significantly enhanced photon-to-electron conversion efficiencies composed of two layers: a top high-Z photon energy attenuation layer (PAL) and a bottom Si detector. We use the principle of photon energy down conversion, where high-energy X-ray photon energies are attenuated down to ≤10 keV via inelastic scattering suitable for efficient photoelectric absorption by Si. Our Monte Carlo simulation results demonstrate that a 10–30× increase in quantum yield can be achieved using PbTe PAL on Si, potentially advancing high-resolution, high-efficiency X-ray detection using PAL-enhanced Si CMOS image sensors.

47 OTHER INSTRUMENTATION↗

Measurements of beam backgrounds in SuperKEKB Phase 2

The high design luminosity of the SuperKEKB electron-positron collider will result in challenging levels of beam-induced backgrounds in the interaction region. Understanding and mitigating these backgrounds is critical to the success of the Belle II experiment. We report on the first background measurements performed after roll-in of the Belle II detector, utilizing both the BEAST II system of dedicated background sensors and the Belle II detector itself. Here we also report on first revisions to the background simulation made in response to our findings. Backgrounds measured include contributions from synchrotron radiation, beam-gas, Touschek, and injection backgrounds. At the end of Phase 2, single-beam backgrounds originating from the 4 GeV positron Low Energy Ring (LER) agree reasonably well with simulation, while backgrounds from the 7 GeV electron High Energy Ring (HER) are approximately one order of magnitude higher than simulation. We extrapolate these backgrounds forward and conclude it is safe to proceed to installation of the Belle II vertex detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino Hunting: Looking through a UV Lens Scintillation Photon Detection in a Large-Volume Liquid Argon Time Projection Chamber, Exposed to a Multi-GeV Charged Particle Beam

The Deep Underground Neutrino Experiment (DUNE) will be a world-class neutrino observatory and nucleon decay detector designed to answer fundamental questions about elementary particles and their role in the universe. The DUNE experiment will consist of a a Near Detector, located at Fermilab, and a Far Detector, approximately 1.5~km underground at the Sanford Underground Research Facility in South Dakota, located $\sim$1300~km away. The accelerator complex at Fermilab will host an intense beam of neutrinos directed toward the two detectors. My dissertation centers on the implementation of technologies used to detect scintillation photon signals in liquid argon in the context of the DUNE's Far Detector Single-Phase (SP) module design, and features direct contributions to the Photon Detection System (PDS) deployed in the ProtoDUNE-SP Large-Volume Liquid Argon Time Projection Chamber (LArTPC) prototype. The PDS is needed for non-beam event timing, such as atmospheric neutrinos, proton d ecay, and supernova detection. The PDS provides a prompt signal ($t_{0}$ information) for micro-second event time determination, which improves the TPC's spatial localization along drift direction, enables accurate ionization-signal-attenuation determination, and even provides calorimetry. My dissertation will discuss an overview of the DUNE and ProtoDUNE-SP experiment and how we detect neutrinos in LAr, via charge and scintillation light. It will discuss my core experimental and analysis work, in regards to the Photon Detection System; including my contributions in establishing procedures for the commissioning and integration for the Photon Detector System that will be valuable during the construction, installation, commissioning, and operations of the DUNE Far Detector. In addition, it will comprehensively discuss the capability of three different photon detection technologies, and their characteristics and responses to muon and electron beam particles over a range of beam momenta , from 0.3~GeV/$c$ - 7~GeV/$c$. Further, the overall progress detailed in this thesis will help pave the way toward understanding the physical properties of these detectors, which will contribute to the success of the sensitivity measurements required for determining the neutrino mass hierarchy and $\delta_{CP}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{cos θ}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio-Frequency Resonances and Damping in Metallic Magnetic Calorimeter Sensors

Metallic magnetic calorimeters (MMCs) are particle detectors that combine ultra-high energy resolution with a predictable and smooth response based on the physics of paramagnetism. For best energy resolution, MMCs are read out with dc SQUID preamplifiers. Since the ac Josephson effect also makes dc SQUIDs broadband RF sources in the 1–100 GHz range, the SQUID can potentially excite RF modes of the MMC sensor, with negative consequences. Further, the importance of this possibility is magnified in direct-coupled MMCs, where the MMC sensor is part of the SQUID loop to maximize performance. For these reasons, the RF behavior of MMC sensors must be investigated. In this report, we present the results of exploratory RF simulations of MMC sensor modes and damping, and we assess three approaches to damp the parallel-meander direct-coupled MMC without excessive noise increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An extended moments model of quantum efficiency for metals and semiconductors

The complexity of photocathode designs and detector materials, and the need to model their performance for short pulse durations, response to high frequency photons, presence of coatings and/or thinness of the absorptive layer, necessitates modifications to three-step and moments models of photoemission that are used in simulation codes. Here, methods to include input from computationally intensive approaches, such as density functional theory to model optical properties and transfer matrix approaches to treat emission from the surface or transport past coatings, by means of parametric models are demonstrated. First, a technique to accurately represent optical behavior so as to model reflectivity and penetration depth is given. Second, modifications to bulk models arising from the usage of thin film architectures, and a means to rapidly calculate them, is provided. Third, a parameterization to model the impact of wells associated with coatings and surface layers on the transmission probably is given. In all cases, the methods are computationally efficient and designed to allow for including input from numerically intensive approaches that would otherwise be unavailable for simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of high energy ionizing radiation using deeply depleted graphene–oxide–semiconductor junctions

Graphene’s linear band structure and two-dimensional density of states provide an implicit advantage for sensing charge. Here, these advantages are leveraged in a deeply depleted graphene–oxide–semiconductor (D2GOS) junction detector architecture to sense carriers created by ionizing radiation. Specifically, the room temperature response of a silicon-based D2GOS junction is analyzed during irradiation with 20 MeV Si4+ ions. Detection was demonstrated for doses ranging from 12 to 1200 ions with device functionality maintained with no substantive degradation. To understand the device response, D2GOS pixels were characterized post-irradiation via a combination of electrical characterization, Raman spectroscopy, and photocurrent mapping. This combined characterization methodology underscores the lack of discernible damage caused by irradiation to the graphene while highlighting the nature of interactions between the incident ions and the silicon absorber.

Ruiz, Isaac↗