Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Teflon FEP Analyzed After Retrieval From the Hubble Space Telescope

During the Hubble Space Telescope (HST) Second Servicing Mission, 6.8 years after the telescope was deployed in low Earth orbit, degradation of unsupported Teflon FEP (DuPont; fluorinated ethylene propylene), used as the outer layer of the multilayer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer (see the photograph) was retrieved during the second servicing mission and returned to Earth for ground testing and evaluation. Also retrieved was a Teflon FEP radiator surface from a cryogen vent cover that was exposed to the space environment on the aft bulkhead of the HST. NASA Goddard Space Flight Center directed the efforts of the Hubble Space Telescope MLI Failure Review Board, whose goals included determining the FEP degradation mechanisms. As part of the investigations into the degradation mechanisms, specimens retrieved from the first and second HST servicing missions, 3.6 and 6.8 years after launch, respectively, were characterized through exhaustive mechanical, optical, and chemical testing. Testing led by Goddard included scanning electron microscopy, optical microscopy, tensile testing, solar absorptance measurements, time-of-flight secondary ion mass spectroscopy (TOF-SIMS), Fourier transform infrared microscopy (m-FTIR), attenuated total reflectance infrared microscopy (ATR/FTIR), and x-ray diffraction (XRD). The NASA Lewis Research Center contributed significantly to the analysis of the retrieved HST materials by leading efforts and providing results of bend testing, surface microhardness measurements, x-ray photoelectron spectroscopy, solid-state nuclear magnetic resonance spectroscopy, and density measurements. Other testing was conducted by Nano Instruments, Inc., and the University of Akron.

Dever, Joyce A.↗

San Marco-C Explorer

On or about 24 April 1971, the San Marco-C spacecraft will be launched from the San Marco Range located off the coast of Kenya, Africa, by a Scout launch vehicle. The launch will be conducted by an Italian crew. The San Marco-C is the third cooperative satellite project between Italy and the United States. The first such cooperative project resulted in the San Marco-1 satellite which was launched into orbit from the Wallops Island Range with a Scout vehicle on 15 December 1964. The successful launch demonstrated the readiness of the Italian Centro Ricerche Aerospaziuli (CRA) launch crews to launch the Scout vehicle and qualified the basic spacecraft design. The second in the series of cooperative satellite launches was the San Marco-II which was successfully launched into orbit from the San Marco Range on 26 April 1967. This was the first Scout launch from the San Marco Range. The San Marco-II carried the same accelerometer as San Marco-1, but the orbit permitted the air drag to be studied in detail in the equatorial region. The successful launch also served to qualify the San Marco Range as a reliable facility for future satellite launches, and has since been used for the successful launch of SAS-A (Explorer 42). This cooperative project has been implemented jointly by the Italian Space Commission and NASA. The CRA provided the spacecraft, its subsystems, and an air drag balance; Goddard Space Flight Center (GSFC) provided an omegatron and a neutral mass spectrometer, technical consultation and support. In addition, NASA provided the Scout launch vehicle. The primary scientific objective of the San Marco-C is to obtain, by measurement, a description of the equatorial neutral-particle atmosphere in terms of its density, com- position, and temperature at altitudes of 200 km and above, and to obtain a description of variations that result from solar and geomagnetic activities. The secondary scientific objective is to investigate the interdependence of three neutral-density-measurement techniques from one spacecraft: direct particle detection, direct drag, and integrated drag.

Source record↗

Turbulence measurements in an equilibrium hypersonic boundary layer

New quantitative turbulence measurements were obtained in a constant pressure, nonadiabatic hypersonic boundary layer, including the first higher moment and probability density measurements of mass-flow and total temperature fluctuations in hypersonic flow. The mass-flow and total temperature fluctuations show that the hypersonic data do not follow the trends set by lower Mach number adiabatic results. Measured intermittency distributions indicate substantial intermittency in the viscous sublayer and in the outer flow; significant differences between the present data and incompressible results are apparent. The higher moment and probability density data show that the character of the mass-flow and total temperature fluctuation modes are significantly different across the entire boundary layer. These differences together with turbulence scale and lifetime data obtained from autocorrelation and space-time correlation measurements are also discussed.-

Owen, F. K.↗

Plume characteristics of MPD thrusters: A preliminary examination

A diagnostics facility for MPD thruster plume measurements was built and is currently undergoing testing. The facility includes electrostatic probes for electron temperature and density measurements, Hall probes for magnetic field and current distribution mapping, and an imaging system to establish the global distribution of plasma species. Preliminary results for MPD thrusters operated at power levels between 30 and 60 kW with solenoidal applied magnetic fields show that the electron density decreases exponentially from 1x10(2) to 2x10(18)/cu m over the first 30 cm of the expansion, while the electron temperature distribution is relatively uniform, decreasing from approximately 2.5 eV to 1.5 eV over the same distance. The radiant intensity of the ArII 4879 A line emission also decays exponentially. Current distribution measurements indicate that a significant fraction of the discharge current is blown into the plume region, and that its distribution depends on the magnitudes of both the discharge current and the applied magnetic field.

Myers, Roger M.↗

Measurement of electron density and temperature in plasmas

Application of two laser wavelengths passing through plasma measures electron density and temperature. Function depends on determining absorption of light at two wavelengths. Nature of reaction is explained and schematic diagram of equipment is included.

Billman, K. W.↗

The intercomparison of ozone measured from the SME and Nimbus-7 satellites on short and long time scales

The spatial and temporal characteristics of ozone density measured from the SBUV (Solar Backscatter Ultraviolet) spectrometer on Nimbus-7 and the UV and the UV and the IR spectrometers on SME (Solar Mesosphere Explorer) are compared in the altitude region near 50 km where the three data sets overlap. Their temporal characteristics, when averaged over the same longitude range, are remarkably similar with respect to seasonal variations and short term fluctuations induced by transient planetary waves. The long term trends in the three data sets, however, differ significantly with each other. Over the three year period after 1982 ozone mixing ratio at 1 mb decreased by about 10 percent based on SEUV measurements but increased by 12 and 30 percent respectively based on SME-IR and SME-UV measurements. None of these estimates are consistent with the predicted decrease of about 2 percent based on solar UV flux and temperature changes during this period.

Chandra, S.↗

High-throughput experimentation for microstructural design in additively manufactured 316L stainless steel

In the present study, a combination of high-throughput (HT) and low-throughput (LT) techniques was used to rapidly determine the processing window and generate processing maps for Selective Laser Melting (SLM) of 316L stainless steel. The HT method includes the fabrication of hundreds of hex nut-shaped specimens, each processed with a unique combination of laser power, scanning speed, and hatch spacing. An easily removable scaffolding permitted rapid sample extraction from the base plate, thus saving machining cost and time. Hardness and immersion density measurements were used for HT characterization to identify a processing window for maximum strength and density. Within the defined processing window, a low-throughput (LT) microstructural interrogation of specimens were performed. The microstructural analysis included quantification at various length scales (i.e., grains size and morphology, texture, primary dendrite arm spacing, and melt pool geometry analysis). Microstructure-based processing maps as a function of volumetric energy density were generated. The combination of HT and LT methods produced a predictive relationship between hardness and primary dendrite arm spacing using a Hall-Petch relationship. A model is proposed to explain the dependence of microstructure on the melt pool geometry. Here, the HT method can be applied for the microstructural design of SLM-fabricated components in other alloys.

316L stainless steel↗

Trebiskyite, the First Titanium-Decavanadate Mineral

Abstract Trebiskyite, Na3Mg2[TiV9O28]·22H2O, from the Pickett Corral mine, Bull Canyon, Montrose County, Colorado, USA, is the first mineral containing essential Ti as a component of a decavanadate polyanion. Crystals are thin prisms or needles up to ∼0.3 mm in length, occurring as individuals and in divergent sprays. Trebiskyite crystals are translucent yellow with vitreous luster and pale-yellow streak and are non-fluorescent under both longwave and shortwave ultraviolet illumination. The crystals exhibit elongation on [001] and are modified by several 0kl prism forms, possibly corresponding to {010}, {011}, and {012}. The Mohs hardness is ca. 2 based on scratch tests. Crystals have brittle tenacity with irregular fracture. No apparent cleavage, nor twinning, was evident, and the mineral is readily soluble in H2O. The density measured by flotation in methylene iodide-toluene mixture is 2.38(2) g/cm3. The calculated density is 2.352 g/cm3 for the empirical formula and 2.343 g/cm3 for the ideal formula. Electron microprobe analyses provided the empirical formula Na3.39Mg1.87V8.75Ti1.25O50H44.00, based on Ti + V = 10 apfu, O = 50 apfu, with the Na content having been determined from the refined crystal structure. Trebiskyite is monoclinic, space group P21/c, a = 9.478(4), b = 21.426(11), c = 11.267(5) Å, β = 114.572(7)°, V = 2080.8(13) Å3, Z = 2. The structure was refined from 6642 reflections to a final R1 = 0.0517 for reflections I > 2σ(I). The structural unit of trebiskyite, (TiV9O28)7−, is built from a Ti-substituted decavanadate polyanion, (V10O28)6−, found in other members of the pascoite family. Chemically, trebiskyite is closely related to lasalite, Na2Mg2[V10O28]·20H2O, and huemulite, Na4Mg[V10O28]·24H2O; however, trebiskyite contains a novel structural arrangement that is unique among the decavanadate minerals. The interstitial complex in trebiskyite has the ideal formula {[Na3Mg2(H2O)19](H2O)3} and consists of chains of distorted octahedrally coordinated Na+ and regular Mg[O(H2O)5] octahedra. The observed low incident bond valence to the V1 site (4.45 vu) and marked deviation in vanadyl and V–Oeq bond lengths indicate that this site is host to the essential Ti4+ identified during chemical analyses.

Mineralogy↗

Saturn's ionosphere: Inferred electron densities

During the two Voyager encounters with Saturn, radio bursts were detected which appear to have originated from atmospheric lightning storms. Although these bursts generally extended over frequencies from as low as 100 kHz to the upper detection limit of the instrument, 40 MHz, they often exhibited a sharp but variable low frequency cutoff below which bursts were not detected. We interpret the variable low-frequency extent of these bursts to be due to the reflection of the radio waves as they propagate through an ionosphere which varies with local time. We obtain estimates of electron densities at a variety of latitude and local time locations. These compare well with the dawn and dusk densitis measured by the Pioneer 11 Voyager Radio Science investigations, and with model predictions for dayside densities. However, we infer a two-order-of-magnitude diurnal variation of electron density, which had not been anticipated by theoretical models of Saturn's ionosphere, and an equally dramatic extinction of ionospheric electron density by Saturn's rings.

Kaiser, M. L.↗

Saturn's ionosphere - Inferred electron densities

During the two Voyager encounters with Saturn, radio bursts were detected which appear to have originated from atmospheric lightning storms. Although these bursts generally extended over frequencies from as low as 100 kHz to the upper detection limit of the instrument, 40 MHz, they often exhibited a sharp but variable low frequency cutoff below which bursts were not detected. We interpret the variable low-frequency extent of these bursts to be due to the reflection of the radio waves as they propagate through an ionosphere which varies with local time. We obtain estimates of electron densities at a variety of latitude and local time locations. These compare well with the dawn and dusk densities measured by the Pioneer 11 Voyager Radio Science investigations, and with model predictions for dayside densities. However, we infer a two-order-of-magnitude diurnal variation of electron density, which had not been anticipated by theoretical models of Saturn's ionosphere, and an equally dramatic extinction of ionospheric electron density by Saturn's rings. Previously announced in STAR as N84-17102

Kaiser, M. L.↗

Plume characteristics of MPD thrusters - A preliminary examination

A diagnostics facility for MPD thruster plume measurements has been built and is currently undergoing testing. The facility includes electrostatic probes for electron temperature and density measurements, Hall probes for magnetic field and current distribution mapping, and an imaging system to establish the global distribution of plasma species. Preliminary results for MPD thrusters operated at power levels between 30 and 60 kW with solenoidal applied magnetic fields show that the electron density decreases exponentially from 1 x 10 to the 20th/cu m to 2 x 10 to the 18th/cu m over the first 30 cm of the expansion, while the electron temperature distribution is relatively uniform, decreasing from approximately 2.5 eV to 1.5 eV over the same distance. The radiant intensity of the ArII 4879 A line emission follows similar patterns. Current distribution measurements indicate that significant fraction of the discharge current is blown into the plume region, and that its distribution depends on the magnitudes of both the discharge current and the applied magnetic field.

Myers, R. M.↗

Upper limits on argon isotope abundances in the Venus thermosphere

On December 9, 1978 the neutral gas mass spectrometer aboard the NASA Pioneer Venus multiprobe bus has measured density, composition, and temperature of the Venus dayside thermosphere. There was no positive identification of argon down to the lowest measuring altitude of 130 km. For the altitude level of 135 km the following upper limits for the number densities of argon isotopes were derived: n(Ar-36) less than 1.3 times 10 to the 6th power per cu cm and n(Ar-40) less than 2.8 times 10 to the 6th power per cu cm. From our upper atmosphere observations we infer for the troposphere of Venus the following upper limits for the mixing ratios: n(Ar-36)/total number density less than 9 times 10 to the minus 6th power and n(Ar-40)/total number density less than 20 times 10 to the minus 6th power.

Mauersberger, K.↗

RMS electron density fluctuation at 1 AU

Analytic expressions at 1 AU for the average RMS Electron Density Fluctuation and the ratio of RMS Electron Density Fluctuation to Electron Density, both as functions of the observational time scale, are constructed from average spacecraft in situ density measurements at approximately 1 AU and columnar phase fluctuation measurements over a wide variety of signal closet approach points. Additionally, the (one-dimensional) Electron Density Fluctuation spectrum and the Doppler phase fluctuation scale are derived, and various extrapolations to the region interior to 1 AU are made.

Berman, A. L.↗

Comparison of Landsat-7 Enhanced Thematic Mapper Plus (ETM+) and Earth Observing One (EO-1) Advanced Land Imager

We compare images from the Enhanced Thematic Mapper Plus (ETM+) sensor on Landsat-7 and the Advanced Land Imager (ALI) instrument on Earth Observing One (EO-1) over a test site in Rochester, New York. The site contains a variety of features, ranging from water of varying depths, deciduous/coniferous forest, and grass fields, to urban areas. Nearly coincident cloud-free images were collected one minute apart on 25 August 2001. We also compare images of a forest site near Howland, Maine, that were collected on 7 September, 2001. We atmospherically corrected each pair of images with the Second Simulation of the Satellite Signal in the Solar Spectrum (6S) atmosphere model, using aerosol optical thickness and water vapor column density measured by in situ Cimel sun photometers within the Aerosol Robotic Network (AERONET), along with ozone density derived from the Total Ozone Mapping Spectrometer (TOMS) on the Earth Probe satellite. We present true-color composites from each instrument that show excellent qualitative agreement between the multispectral sensors, along with grey-scale images that demonstrate a significantly improved ALI panchromatic band. We quantitatively compare ALI and ETM+ reflectance spectra of a grassy field in Rochester and find < or equal to 6% differences in the visible/near infrared and approx. 2% differences in the short wave infrared. Spectral comparisons of forest sites in Rochester and Howland yield similar percentage agreement except for band 1, which has very low reflectance. Principal component analyses and comparison of normalized difference vegetation index histograms for each sensor indicate that the ALI is able to reproduce the information content in the ETM+ but with superior signal-to-noise performance due to its increased 12-bit quantization.

Pedelty, Jeffrey A.↗

A Regional CO2 Observing System Simulation Experiment for the ASCENDS Satellite Mission

Top-down estimates of the spatiotemporal variations in emissions and uptake of CO2 will benefit from the increasing measurement density brought by recent and future additions to the suite of in situ and remote CO2 measurement platforms. In particular, the planned NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) satellite mission will provide greater coverage in cloudy regions, at high latitudes, and at night than passive satellite systems, as well as high precision and accuracy. In a novel approach to quantifying the ability of satellite column measurements to constrain CO2 fluxes, we use a portable library of footprints (surface influence functions) generated by the WRF-STILT Lagrangian transport model in a regional Bayesian synthesis inversion. The regional Lagrangian framework is well suited to make use of ASCENDS observations to constrain fluxes at high resolution, in this case at 1 degree latitude x 1 degree longitude and weekly for North America. We consider random measurement errors only, modeled as a function of mission and instrument design specifications along with realistic atmospheric and surface conditions. We find that the ASCENDS observations could potentially reduce flux uncertainties substantially at biome and finer scales. At the 1 degree x 1 degree, weekly scale, the largest uncertainty reductions, on the order of 50 percent, occur where and when there is good coverage by observations with low measurement errors and the a priori uncertainties are large. Uncertainty reductions are smaller for a 1.57 micron candidate wavelength than for a 2.05 micron wavelength, and are smaller for the higher of the two measurement error levels that we consider (1.0 ppm vs. 0.5 ppm clear-sky error at Railroad Valley, Nevada). Uncertainty reductions at the annual, biome scale range from 40 percent to 75 percent across our four instrument design cases, and from 65 percent to 85 percent for the continent as a whole. Our uncertainty reductions at various scales are substantially smaller than those from a global ASCENDS inversion on a coarser grid, demonstrating how quantitative results can depend on inversion methodology. The a posteriori flux uncertainties we obtain, ranging from 0.01 to 0.06 Pg C yr-1 across the biomes, would meet requirements for improved understanding of long-term carbon sinks suggested by a previous study.

remote sensing↗