Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryocoolers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Beam combining of high-power terahertz lasers with semiconductor metasurface gratings

Spectral beam combining (SBC) of an array of single-mode lasers has the potential for realizing a chip-scale electrically tunable multispectral laser source without any moving parts and with emission at closely spaced discrete frequencies. Here, we demonstrate SBC of an array of single-mode THz quantum-cascade lasers (QCLs) with small frequency spacing. Semiconductor-based metasurface THz blazed gratings are developed for integration with QCLs in a compact cryocooler setup. Single-lobed beams of four QCLs emitting around 3.2 THz and spectrally separated by ~14 GHz are combined to achieve collinear propagation of spatially overlapped and collimated beams in the far field with ≲ 0.1° of pointing error. Peak optical power in the range 50–100 mW is detected from each of the QCLs after combining. The dense frequency spacing in our method provides a pathway to incorporate tens of QCLs on a chip to realize a high-power discretely tunable THz laser source for applications in THz spectroscopy.

Jia, Fei [Lehigh Univ., Bethlehem, PA (United Stat↗

Ion Generation Using Frozen Xenon Target for Laser Ion Source

A frozen laser target that is in the gaseous phase at room temperature is advantageous for a laser ion source because it can avoid the accumulation of damage from laser irradiation by regeneration of the target surface by additional gas freezing. In this study, the possibility of forming a xenon ion beam with a current sufficient for heavy-ion inertial fusion (HIF) was investigated. The relationship between the frozen target growth and resulting ion current was analyzed to determine the optimal condition of laser irradiation that ensures stable supply of ion beams for a long time. A frozen target of xenon was formed on a mount cooled to 20 K using a Gifford McMahon cryocooler, and plasma was generated using a Nd:YAG laser. Here, the results showed that it is possible to supply a sufficient ion current for application of singly charged ions as a driver for HIF. Additionally, it was indicated that the xenon responsible for forming the plasma existed only at a certain depth from the target surface. The results imply that it is possible to obtain a stable ion supply for a long time by irradiating the target with a laser after the frozen xenon grows to a sufficient thickness.

43 PARTICLE ACCELERATORS↗

Niobium-tin as a transformative technology for low-beta linacs

Niobium-tin has been identified as the most promising next-generation superconducting material for accelerator cavities. This is due to the higher critical temperature (Tc = 18 K) of Nb3Sn compared to niobium (TC = 9.2 K), which leads to greatly reduced RF losses in the cavity during 4.5 K operation. This allows two important changes during cavity and cryomodule design. First, the higher Tc leads to negligible BCS losses when operated at 4.5 K, which allows for a higher frequency to be used, translating to significantly smaller cavities and cryomodules. Second, the reduced dissipated power lowers the required cryogenic cooling capacity, meaning that cavities can feasibly be operated on 5-10 W cryocoolers instead of a centralized helium refrigeration plant. These plants and distribution systems are costly and complex, requiring skilled technicians for operation and maintenance. These fundamental changes present an opportunity for a paradigm shift in how low-beta linacs are designed and operated. Fabrication challenges and first coated cavity test results are discussed.

43 PARTICLE ACCELERATORS↗

Nb$^{3}$Sn Technology for Low-beta linacs

Nb3Sn is the most advanced potential successor for niobium in superconducting RF accelerator cavities. Nb3Sn has a significantly higher critical temperature (18.3 K) compared to that of niobium (9.2 K). This has a large effect on the BCS surface resistance, and therefore, on the dynamic RF losses at 4.5 K. The higher critical temperature allows two important changes for cavity and cryomodule design. First, the lower BCS losses allow the designer to use a higher frequency, translating to physically smaller cavities and cryomodules. Second, the low dynamic losses allow the use of stand-alone cryocoolers instead of complex helium refrigerators and distribution systems. Fabrication of a prototype 218 MHz cavity, test results, and continuing challenges are discussed.

43 PARTICLE ACCELERATORS↗

Thermal Modeling and Cryogenic Design of a Helical Superconducting Undulator Cryostat

A conceptual design for a helical superconducting undulator (HSCU) for the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) has been completed. The device differs sufficiently from the existing APS planar superconducting undulator (SCU) design to warrant development of a new cryostat based on value engineering and lessons learned from the existing planar SCU. Changes include optimization of the existing cryocooler-based refrigeration system and thermal shield as well as cost reduction through the use of standard vacuum hardware. The end result is a design that provides significantly larger 4.2 K refrigeration margin in a smaller package for greater installation flexibility in the APS storage ring. This paper presents ANSYS-based thermal analysis of the cryostat, including estimated static and dynamic

Shiroyanagi, Y.↗

Compact, High-Power Superconducting Electron Linear Accelerators for MW Industrial Applications

Fermilab has developed a novel concept for an industrial electron linac using Nb₃Sn coating technology and conduction cooling. We will show the range of multi-cavity linac designs targeted toward various applications. We will also discuss technology development status with results on conduction cooling of SRF cavities based on cryocoolers, which removes the need for liquid Helium, thus making SRF technology accessible to industrial applications. These conduction-cooled linacs can generate electron beam energies up to 10 MeV in continuous-wave operation and can reach higher power (>=1 MW) by combing several modules. Compact and light enough to mount on mobile platforms, our machine is anticipated to enable new in-situ environmental remediation applications such as waste-water treatment for urban areas, X-ray medical device sterilization, and innovative pavement applications. We also show cost-economics and key R&D areas that much be addressed for a practical machine.

43 PARTICLE ACCELERATORS↗

First High-Gradient Results of UED/UEM SRF Gun at Cryogenic Temperatures

Benefiting from the rapid progress on RF photogun technologies in the past two decades, the development of MeV range ultrafast electron diffraction/microscopy (UED and UEM) has been identified as an enabling instrumentation. UEM or UED use low power electron beams with modest energies of a few MeV to study ultrafast phenomena in a variety of novel and exotic materials. SRF photoguns become a promising candidate to produce highly stable electrons for UEM/UED applications because of the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb₃Sn and conduction cooling. The use of Nb₃Sn allows to operate SRF cavities at higher temperatures (4K) with low power dissipation which is within the reach of commercially available closed-cycle cryocoolers. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. In this paper, we present first high gradient results of the gun conducted in liquid helium.

43 PARTICLE ACCELERATORS↗

Simulation of the thermoelectric effect in a multi-metallic superconducting cavity

Superconducting radio-frequency accelerating cavities made with different material layers, such as copper, Nb or Nb₃Sn, are susceptible to thermoelectric effects due to differences in Seebeck coefficients between the metals. A temperature gradient across the surfaces can drive thermoelectric currents, which may impact the cavity performance. A layered Cu/Nb/Nb3Sn single-cell cavity was tested with cryocoolers in 2022. Three heaters were mounted on the cavity surface at different locations and three single-axis cryogenic fluxgate magnetometers were attached close to the cavity equator. A linear increase in the magnetic field was measured while increasing the heaters' power. The cavity setup was analyzed with COMSOL and the results showed a trend similar to that observed in the experiment. This contribution details the approach chosen for the simulation and some of the challenges encountered.

Accelerator Physics↗

ON THE WAY TO A 10MEV, CONDUCTION-COOLED COMPACT SRF ACCELERATOR

After the success of designing a compact 1MeV, 1MW accelerator based on conduction-cooled SRF, Jefferson Lab is now pursuing a concept to provide a tenfold increase of the beam energy. The obvious challenge for SRF is to move from a single-cell to a multicell cavity while maintaining high efficiency and the ability to operate the machine without a complex cryogenic plant. This paper summarizes the current state of this effort with respect to the design of a Nb3Sn coated five-cell cavity and the corresponding RF components, especially the fundamental power coupler (FPC), as well as first thermal analysis of the cryocooler-based cooling setup.

Ciovati, G.↗

Design of a 915 MHz conduction-cooled cryomodule

High-power, compact, continuous-wave (CW) linear electron accelerators with beam energies of up to 10 MeV are being considered for possible industrial applications. Conduction-cooled, superconducting radio-frequency (SRF) technology allows operating such machines at high electrical efficiency, thereby reducing the operating cost significantly. A prototype conduction-cooled SRF cryomodule has been designed and components are currently being manufactured. The cryomodule features a two-cell, 915 MHz SRF cavity, two cryocoolers, a fundamental power coupler, two magnetic shields, a thermal shield and warm-to-cold transitions. The cryomodule has been designed to be able to provide an energy gain of 3.5 MeV to a CW electron beam with a current of 5 mA. This contribution focusses on thermal and mechanical design aspects of the cryomodule.

Ciovati, G. [Old Dominion Univ., Norfolk, VA (Unit↗

Nonlinear Signal Processing for Removing Microphonic Noise from Nuclear Spectrometer Measurements: Sparse Linear Modeling via L1 Norm Regularization [Slides]

The focus of this initial work is to apply recent breakthroughs in sparse linear modeling and nonlinear signal processing to the problem of removing microphonic noise from nuclear spectrum measurements. The resolution of nuclear spectrum measurements is commonly degraded by microphonic noise caused by the vibration of supporting equipment (i.e. cryocoolers) as well as motion of the detector itself in mobile applications. Current signal processing techniques cannot remove microphonic noise without modifying the desired characteristics of the spikes induced by nuclear detection events. The LANL Engineering Institute has been working with NEN‐1 to remedy this problem. Initial work focused on developing active control systems to cancel the vibrations experienced by nuclear detectors. As work on progressed along these lines the team realized that a more robust, lower‐energy, lower‐cost solution to the microphonic noise problem could be realized using recent breakthroughs in nonlinear signal processing. Over the course of the last decade significant advances have been made in the field of sparse linear modeling using L1 norm minimization to find linear representations of sparse signals. The problem of removing microphonic noise from nuclear detection measurements appears to be well suited to the L1 minimization approach because these measurements tend to be inherently sparse in two different domains. The nuclear detections are sparse in a spike domain, and the microphonic noise is sparse in the Fourier basis. L1 minimization allows us to decompose the measurements into these two domains. The result is that we can potentially separate the spikes from the microphonic noise. Initial investigations into this technique look very promising. In this work microphonic noise is induced in an HE‐3 detector by a wrench impact. A pulser is used to generate uniform, synthetic, nuclear events and is fed into the detector front end electronics. Nearly all the microphonic noise is separated from the spike measurements. The histograms in Figure 2 illustrate that spectrum widening caused by noise is significantly reduced. The goal of future work to further develop this technique to account for variations in spike characteristics, as well as to use adaptive signal processing and modern Graphical Processing Unit (GPU) technology to speed up the signal decompositions.

42 ENGINEERING↗

Multi-Column Experimental Test Bed Using CaSDB MOF for Xe/Kr Separation

Processing of spent nuclear fuel produces off-gas from which several volatile radioactive components must be separated for further treatment or storage. As part of the Off-gas Sigma Team, parallel research at INL and PNNL has produced several promising sorbents for the selective capture of xenon and krypton from these off-gas streams. In order to design full-scale treatment systems, sorbents that are promising on a laboratory scale must be proven under process conditions to be considered for pilot and then full-scale use. To that end, a bench-scale multi-column system with capability to test multiple sorbents was designed and constructed at INL. This report details bench-scale testing of CaSDB MOF, produced at PNNL, and compares the results to those reported last year using INL engineered sorbents. Two multi-column tests were performed with the CaSDB MOF installed in the first column, followed with HZ-PAN installed in the second column. The CaSDB MOF column was placed in a Stirling cryocooler while the cryostat was employed for the HZ-PAN column. Test temperatures of 253 K and 191 K were selected for the first column while the second column was held at 191 K for both tests. Calibrated volume sample bombs were utilized for gas stream analyses. At the conclusion of each test, samples were collected from each column and analyzed for gas composition. While CaSDB MOF does appear to have good capacity for Xe, the short time to initial breakthrough would make design of a continuous adsorption/desorption cycle difficult, requiring either very large columns or a large number of smaller columns. Because of the tenacity with which Xe and Kr adhere to the material once adsorbed, this CaSDB MOF may be more suitable for use as a long-term storage solution. Further testing is recommended to determine if CaSDB MOF is suitable for this purpose.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reliable, Practical Kilowatt-class Cryogenics for Superconducting Devices

Following the successful development of a Flexibly-Attached Remote cryocooler for ~200W at 80K under a Phase II DOE grant, Clever Fellows Innovation Consortium, Inc. (dba CFIC-Qdrive; acquired by Chart Industries in 2012) was invited by the DOE to scale up this technology to ~1000W/80K in a Phase III program. This target is responsive to the “Cryogenics Roadmap” developed by the DOE to accelerate the development of cryogenic cooling necessary to support the emerging superconducting power applications. Mirroring the Roadmap, our proposal included a capacity target (1000W at 80K) and a cost target (<$40/watt, at 80K), but unlike the Roadmap, we did not formally propose to meet a specific efficiency target. We achieved 75% of the capacity target, with a record-size coaxial “pulse-tube” coldfinger, but only by working on the project well beyond the original “period of performance” on unfunded extension. We believe 100% of the capacity target was within reach, but our own budget and time constraints forbade additional effort. We were less successful in meeting the cost targets. Ultimately, the specific configuration that was the subject of Phase III was not commercialized, largely because the market for superconducting devices has not been nearly as robust as was expected at the advent of the Roadmap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Magnesium Diboride thin Films, multilayers, and coatings for SRF cavities

Superconducting radio frequency (SRF) cavities currently use low-temperature superconductor niobium, and the Nb SRF cavities have approached the performance levels predicted theoretically. Compared to Nb, MgB 2 becomes superconducting at a much higher temperature and promises a better RF performance in terms of higher quality factor Q and higher acceleration capability. An MgB 2 SRF technology can significantly reduce the operating costs of particle accelerators when these potentials are realized. This project aimed to advance the development of an MgB 2 SRF technology. It had two main objectives: (1) materials issues of MgB 2 thin films and multilayers related to their applications in SRF cavities; and (2) coating single-cell cavities for testing at RF frequencies. The key technical thrust of the project is the deposition of high quality clean MgB 2 films and coatings by the hybrid physical-chemical vapor deposition (HPCVD) technique, which was developed in my group. We have achieved technical progress in each of the two areas. For the first objective, we have confirmed that MgB 2 thin film coatings can be used to effectively enhance the vortex penetration field of an SRF cavity. A vortex is a normal region in the shape of spaghetti that threads through a superconductor. Its existence is due to an applied magnetic field that is greater than a so-called lower critical field, H c1 . Once a vortex enters the superconductor, its movement leads to loss. This has been shown to be the reason for an SRF cavity to break down. Thus, enhancing the magnetic field for a vortex to enter the superconductor that forms the SRF cavity has be a goal of intense research. To this end, Gurevich proposed that a coating of thin superconductor layer can impede the vortex entrance. In this project, we have done two important experiment to test this concept. One, we showed that the enhancement of H c1 can be achieved by using in both epitaxial and polycrystalline MgB 2 films. Although H c1 is low for bulk MgB 2 samples, about 600 Oe at 5 K, it increases with decreasing film thickness, reaching 1880 Oe when the film thickness is 100 nm. Two, we coated Nb ellipsoids with MgB 2 films to achieve an “inverse cavity” configuration, mimicking the coating of an actual RF cavity. Our results demonstrate that it is indeed possible to increase the vortex penetration field of a cavity by a substantial amount (~600 Oe) by coating it with a thin MgB 2 film. For the second objective, we modified the existing HPCVD system to be able to coat a 3.9 GHz SRF cavity, and using a stainless steel mock cavity showed that a uniform film with good superconducting property can be grown across the cavity interior. Further, we successfully deposited MgB 2 on Cu disc. The two results combined demonstrate that it is possible to coat Cu cavities with high quality MgB 2 films using HPCVD. MgB 2 coated Cu could open up a possibility of using SRF cavities at 20–25 K with cryocoolers.

36 MATERIALS SCIENCE↗

Heat Treatment of Iron-Carbon Alloys in a Magnetic Field (Phase 2)

Thermomagnetic processing was shown to shift the phase transformation temperatures and therefore microstructural evolution in the high performance engine valve spring 9254 steel alloy by applying a high magnetic field during cooling. These effects would be anticipated to improve performance such as high cycle fatigue as demonstrated in prior projects. Thermomagnetic processing of gears and crank shafts was constrained by the size of the prototype equipment currently available at ORNL. However, the commercial procurement viability of production scale 9-Tesla, 16-inch diameter bore thermomagnetic processing equipment for truck idler gears up to ~11-inch diameter and potential crank shaft applications was shown, as multiple superconducting magnet manufacturing companies (in conjunction with an induction heat treating company, AjaxTOCCO Magnethermic) offered cryogen-free or cryocooler equipment designs to Cummins.

36 MATERIALS SCIENCE↗

NA22 Ge-140 FY17 end of year report [Ge-140 Spectrometer]

The goal of this three-year project is to build a hand-held, high-resolution, germanium-based, gamma-ray spectrometer of 140% relative efficiency that is mechanically cooled. The final instrument should be light enough to be easily carried by one person, and the power consumption should be low enough for battery operation. We completed the Ge-140 design and demonstrated a cryostat with excellent thermal isolation. We performed tests to compare and verify the performance of viable cryocooler candidates, and developed a suspension system that will protect the crystal against shock and vibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Conduction Cooled SRF Cavity

SRF cavities are used heavily in high energy physics research, and simplifying operation of SRF cavities could enable their use in many fields of industry. Liquid helium coolant systems are a notable complexity of operating SRF cavities, and replacing liquid helium with cryocooler conduction cooling is an important research and development interest. As part of this effort, a system consisting of a 650 MHz single cell cavity, a commercial grade pulse tube refrigerator, and an aluminum thermal link was simulated through finite element analysis. The electromagnetic fields inside the cavity, heat flow through the system, and temperature distribution of the thermal link and cavity were calculated. Based on the simulations, the pulse tube refrigerator is capable of supplying adequate cooling power to a cavity with \ce{Nb3Sn} coating operating with an accelerating gradient between 6 and 12 MV/m. The maximum simulated temperature of the cavity was below 7 K, and the oscilla tions in temperature introduced by the pulse tube refrigerator were shown to dampen in amplitude before reaching the cavity surface.

43 PARTICLE ACCELERATORS↗

Deposit high purity Alumnium on Nb in support of conduction cooled SRF cavities

The project will demonstrate a potential manufacturing method that could result in a means to operate superconducting radio frequency (SRF) cavities without liquid cryogens. The technical approach sought to apply high-purity (99.999%) aluminum to cavity-grade niobium components via a new and proprietary electron-beam additive manufacturing technique contributed by PAVAC. High thermal conductivity of the aluminum could enable a cryocooler, which is a compact electrically powered refrigeration device, to extract sufficient heat for operating the cavity for a variety of applications. Trial coatings of niobium components were to be evaluated for metallurgy, mechanical bonding, and thermal and electrical conductivity using superconducting materials characterization facilities at Fermilab. The results of the characterization were intended to provide process feedback and optimization to PAVAC. During the project, PAVAC completed one set of samples. However, due to a business reorganization, PAVAC choose not to proceed toward a second set of samples using their proprietary approach. The PAVAC technical goal was replaced by a Fermilab goal to determine whether high-purity aluminum could be attached to niobium by a system of welded stud anchors and fasteners. The project pivoted to evaluations of trial stud welded anchors using infrastructure and expertise similar to that applied to the PAVAC applied coatings.

43 PARTICLE ACCELERATORS↗