Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

How reduced vacuum pumping capability in a coating chamber affects the laser damage resistance of HfO 2 /SiO 2 antireflection and high reflection coatings.

Optical coatings with the highest laser damage thresholds rely on clean conditions in the vacuum chamber during the coating deposition process. A low base pressure in the coating chamber, as well as the ability of the vacuum system to maintain the required pressure during deposition, are important aspects of limiting the amount of defects in an optical coating that could induce laser damage. Our large optics coating chamber at Sandia National Laboratories normally relies on three cryo pumps to maintain low pressures for e-beam coating processes. However, on occasion, one or more of the cryo pumps have been out of commission. In light of this circumstance, we explored how deposition under compromised vacuum conditions resulting from the use of only one or two cryo pumps affects the laser-induced damage thresholds of optical coatings. Finally, the coatings of this study consist of HfO 2 and SiO 2 layer materials and include antireflection coatings for 527 nm at normal incidence, and high reflection coatings for 527 nm, 45⁰ angle of incidence (AOI), in P-polarization (P-pol).

Field, Ella Suzanne↗

Planar 2D wireframe DNA origami

Two-dimensional (2D) DNA origami is widely used for applications ranging from excitonics to single-molecule biophysics. Conventional, single-layer 2D DNA origami exhibits flexibility and curvature in solution; however, that may limit its suitability as a 2D structural template. In contrast, 2D wireframe DNA origami rendered with six-helix bundle edges offers local control over duplex orientations with enhanced in-plane rigidity. Here, we investigate the 3D structure of these assemblies using cryo–electron microscopy (cryo-EM). 3D reconstructions reveal a high degree of planarity and homogeneity in solution for polygonal objects with and without internal mesh, enabling 10-Å resolution for a triangle. Coarse-grained simulations were in agreement with cryo-EM data, offering molecular structural insight into this class of 2D DNA origami. Our results suggest that these assemblies may be valuable for 2D material applications and geometries that require high structural fidelity together with local control over duplex orientations, rather than parallel duplex assembly.

59 BASIC BIOLOGICAL SCIENCES↗

A viral RNA hijacks host machinery using dynamic conformational changes of a tRNA-like structure

Viruses require multifunctional structured RNAs to hijack their host’s biochemistry, but their mechanisms can be obscured by the difficulty of solving conformationally dynamic RNA structures. Using cryo–electron microscopy (cryo-EM), we visualized the structure of the mysterious viral transfer RNA (tRNA)–like structure (TLS) from the brome mosaic virus, which affects replication, translation, and genome encapsidation. Structures in isolation and those bound to tyrosyl-tRNA synthetase (TyrRS) show that this ~55-kilodalton purported tRNA mimic undergoes large conformational rearrangements to bind TyrRS in a form that differs substantially from that of tRNA. Our study reveals how viral RNAs can use a combination of static and dynamic RNA structures to bind host machinery through highly noncanonical interactions, and we highlight the utility of cryo-EM for visualizing small, conformationally dynamic structured RNAs.

Science & Technology - Other Topics↗

The 2.3-Angstrom Structure of Porcine Circovirus 2

Porcine circovirus 2 (PCV2) is a T = 1 nonenveloped icosahedral virus that has had severe impact on the swine industry. Here we report the crystal structure of an N-terminally truncated PCV2 virus-like particle at 2.3-{angstrom} resolution, and the cryo-electron microscopy (cryo-EM) image reconstruction of a full-length PCV2 virus-like particle at 9.6-{angstrom} resolution. This is the first atomic structure of a circovirus. The crystal structure revealed that the capsid protein fold is a canonical viral jelly roll. The loops connecting the strands of the jelly roll define the limited features of the surface. Sulfate ions interacting with the surface and electrostatic potential calculations strongly suggest a heparan sulfate binding site that allows PCV2 to gain entry into the cell. The crystal structure also allowed previously determined epitopes of the capsid to be visualized. The cryo-EM image reconstruction showed that the location of the N terminus, absent in the crystal structure, is inside the capsid. As the N terminus was previously shown to be antigenic, it may externalize through viral 'breathing'.

59 BASIC BIOLOGICAL SCIENCES↗

SAXS studies of X-ray induced disulfide bond damage: Engineering high-resolution insight from a low-resolution technique

A significant problem in biological X-ray crystallography is the radiation chemistry caused by the incident X-ray beam. This produces both global and site-specific damage. Site specific damage can misdirect the biological interpretation of the structural models produced. Cryo-cooling crystals has been successful in mitigating damage but not eliminating it altogether; however, cryo-cooling can be difficult in some cases and has also been shown to limit functionally relevant protein conformations. The doses used for X-ray crystallography are typically in the kilo-gray to mega-gray range. While disulfide bonds are among the most significantly affected species in proteins in the crystalline state at both cryogenic and higher temperatures, there is limited information on their response to low X-ray doses in solution, the details of which might inform biomedical applications of X-rays. In this work we engineered a protein that dimerizes through a susceptible disulfide bond to relate the radiation damage processes seen in cryo-cooled crystals to those closer to physiologic conditions. This approach enables a low-resolution technique, small angle X-ray scattering (SAXS), to detect and monitor a residue specific process. A dose dependent fragmentation of the engineered protein was seen that can be explained by a dimer to monomer transition through disulfide bond cleavage. This supports the crystallographically derived mechanism and demonstrates that results obtained crystallographically can be usefully extrapolated to physiologic conditions. Fragmentation was influenced by pH and the conformation of the dimer, providing information on mechanism and pointing to future routes for investigation and potential mitigation. The novel engineered protein approach to generate a large-scale change through a site-specific interaction represents a promising tool for advancing radiation damage studies under solution conditions.

59 BASIC BIOLOGICAL SCIENCES↗

General Motors: Final Report for Hydrogen Storage Engineering Center of Excellence

As part of the HSECoE team, the GM team built system models and detailed transport models for on-board hydrogen storage systems using metal hydrides and adsorbent materials. Detailed transport models have been developed for both the metal hydride and adsorbent systems with a focus on optimization of heat exchanger designs with the objective of minimizing the heat exchanger mass. We also performed work in collaboration with our partners on storage media structuring and enhancement studies for the metal hydride and adsorbent materials. Since the hydrogen storage materials are generally characterized by low density and low thermal conductivity, we conducted experiments to form pellets and add thermal conductivity enhancers to the storage material, and to improve cycling stability and durability of the metal hydride and adsorbent materials. Refueling of a MOF-5 pellet with cryogenic hydrogen was studied by developing a detailed two-dimensional axisymmetric COMSOL® model of the process. The effects of pellet permeability, thermal conductivity, and thermal conductivity enhancers were investigated. Our key area of focus has been on designing and building a cryo-adsorption vessel for validation of cryo-adsorption models. The 3-L cryogenic tank was used to study the fast fill and discharge dynamics of a cryo-adsorbent storage system, both experimentally and numerically.

08 HYDROGEN↗

Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents

This report summarizes the work performed under the Department of Energy’s National Energy Technology Laboratory (DOE-NETL) Advanced Energy Systems Program award number DE-FE0026163 Improving Energy Efficiency of Air Separation via Hollow Fiber Sorbents. The overall objective of the project was to develop technology to produce oxygen for use in coal gasification processes at a significantly lower cost than that of the commercial state-of-the-art technology. The focus of the project was development and optimization of hollow fiber sorbents for use in a pressure swing adsorption (PSA) process for producing oxygen from air. The key technical advancement under this program was the development of a hollow fiber sorbent capable of producing oxygen in a PSA process. PSAs produce oxygen by using a beaded zeolite material (typically lithium exchanged zeolites or LiX) that selectively adsorb nitrogen over oxygen. For a fiber to adsorb nitrogen, LiX needed to be integrated into a polymer fiber and then activated at over 350C to remove residual moisture. After screening multiple materials and process techniques, Matrimid/LiX hollow fibers were produced that were able to withstand the activation and had crystalline nitrogen capacity close to pure LiX crystals. The fibers were dual layer fibers with a barrier layer isolating the hollow bore from the LiX embedded layer. The barrier layer was formed from an Ultem® based solution. The hollow bore was intended for encapsulating phase change materials to ensure isothermal PSA operation. Modeling work from the project suggested that the benefits of this additional complexity were marginal, thus the team fabricated non-hollow fibers comprised of Matrimid and LiX. The Matrimid/LiX fibers were loaded into a module and tested on a bench scale PSA unit. The fibers were able to separate oxygen from air, but the purity and recovery were lower than expected and lower than traditional beaded LiX zeolites, although modeling results suggested that the bed sizes for fiber sorbents could be half the size of a beaded LiX bed. Additional work will be needed to understand the shortfall and to produce fiber sorbent modules with performance equal to the targets set for this program. In addition to producing fibers, modeling work was carried out at both the fiber level and process level to guide both fiber sorbent development and to determine the optimal process conditions for a PSA using fiber sorbents. A 2D hollow fiber model was developed in gPROMS Model Builder. This model was based on literature data for mass transfer and other parameters. This model used a basic single bed PSA process to determine important fiber properties and process conditions for achieving high oxygen recovery. The preliminary 2D fiber model was a valuable tool, however, for step-out technologies, such as a PSA process with fiber sorbents, intelligent optimization and plant control was needed to effectively determine minimum power designs. Therefore, a gPROMS Process Builder-based optimization tool was developed with an “Automated Cycle Optimizer” model that was able to determine optimal cycle conditions for a fiber sorbent PSA. The results from the optimizer were used in the final power analysis. Flow sheet analysis and techno-economic analysis (TEA) was carried out to determine a lower power solution versus the baseline case. The original project scope suggested that the fiber sorbent PSA could be used to debottleneck a cryogenic air separation plant (cryo-ASU) with the combined plant having lower power than a standalone cryo-ASU. However, early flowsheet analysis showed that the PSA/cryo-ASU concept would not lead to a lower power solution. However, further flowsheet analysis suggested that an oxygen PSA combined with a nitrogen PSA could have lower power versus state-of-the-art air separation technology. Work concluded with the TEA showing a fiber sorbent oxygen PSA combined with an advanced nitrogen PSA could be up to 8% lower power versus the base case cryo-ASU. Overall, there is significant potential remaining for the zeolite hollow fiber sorbent concept, and this project successfully identified -- and ultimately remedied -- many technical challenges associated with scale-up.

01 COAL, LIGNITE, AND PEAT↗

Streptavidin Affinity Grids for the Preparation of Biological Samples for Cryogenic Electron Microscopy (CRADA Final Report)

Currently, cryo-EM is the most powerful tool for structural analysis of large biomacromolecules, but there are still problems in that biomacromolecules are denatured at the air-interface and their orientations are limited in a specific orientation. We solved this problem at LBL by developing a streptavidin-coated EM grid. Use of such affinity-binding grids can minimize exposure to air-interface by keeping biomacromolecules bound to streptavidin. It is urgently needed to make such grids readily available to the cryo-EM community, but they are somewhat difficult to make. The goal of the CRADA with Hummingbird company was to mass-produce the streptavidin grids so that they would become readily available to the cryo-EM community. Our contribution to the CRADA was to first help Hummingbird to replicate the manual process that we use, and this was completed successfully.

59 BASIC BIOLOGICAL SCIENCES↗

Optimized Negative Staining: a High-throughput Protocol for Examining Small and Asymmetric Protein Structure by Electron Microscopy

Structural determination of proteins is rather challenging for proteins with molecular masses between 40 - 200 kDa. Considering that more than half of natural proteins have a molecular mass between 40 - 200 kDa, a robust and high-throughput method with a nanometer resolution capability is needed. Negative staining (NS) electron microscopy (EM) is an easy, rapid, and qualitative approach which has frequently been used in research laboratories to examine protein structure and protein-protein interactions. Unfortunately, conventional NS protocols often generate structural artifacts on proteins, especially with lipoproteins that usually form presenting rouleaux artifacts. By using images of lipoproteins from cryo-electron microscopy (cryo-EM) as a standard, the key parameters in NS specimen preparation conditions were recently screened and reported as the optimized NS protocol (OpNS), a modified conventional NS protocol. Artifacts like rouleaux can be greatly limited by OpNS, additionally providing high contrast along with reasonably high-resolution (near 1 nm) images of small and asymmetric proteins. These high-resolution and high contrast images are even favorable for an individual protein (a single object, no average) 3D reconstruction, such as a 160 kDa antibody, through the method of electron tomography. Moreover, OpNS can be a high-throughput tool to examine hundreds of samples of small proteins. For example, the previously published mechanism of 53 kDa cholesteryl ester transfer protein (CETP) involved the screening and imaging of hundreds of samples. Considering cryo-EM rarely successfully images proteins less than 200 kDa has yet to publish any study involving screening over one hundred sample conditions, it is fair to call OpNS a high-throughput method for studying small proteins. Hopefully the OpNS protocol presented here can be a useful tool to push the boundaries of EM and accelerate EM studies into small protein structure, dynamics and mechanisms.

47 OTHER INSTRUMENTATION↗

Structural and biophysical analysis of a Haemophilus influenzae tripartite ATP-independent periplasmic (TRAP) transporter

Tripartite ATP-independent periplasmic (TRAP) transporters are secondary-active transporters that receive their substrates via a soluble-binding protein to move bioorganic acids across bacterial or archaeal cell membranes. Recent cryo-electron microscopy (cryo-EM) structures of TRAP transporters provide a broad framework to understand how they work, but the mechanistic details of transport are not yet defined. Here we report the cryo-EM structure of the Haemophilus influenzae N-acetylneuraminate TRAP transporter (HiSiaQM) at 2.99 Å resolution (extending to 2.2 Å at the core), revealing new features. The improved resolution (the previous HiSiaQM structure is 4.7 Å resolution) permits accurate assignment of two Na + sites and the architecture of the substrate-binding site, consistent with mutagenic and functional data. Moreover, rather than a monomer, the HiSiaQM structure is a homodimer. We observe lipids at the dimer interface, as well as a lipid trapped within the fusion that links the SiaQ and SiaM subunits. We show that the affinity (K D ) for the complex between the soluble HiSiaP protein and HiSiaQM is in the micromolar range and that a related SiaP can bind HiSiaQM. This work provides key data that enhances our understanding of the ‘elevator-with-an-operator’ mechanism of TRAP transporters.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of a combined refrigerator-generator space power system

Compatibility of the Brayton power and refrigeration cycles is considered. Performance of the power- and cryo-loop is plotted against compressor pressure ratio. The power- and cryo-loop performance is determined by dividing the compressor work between the two loops in proportion to mass flow rate. Cycle efficiency is defined as the ratio of shaft power available in the power loop to the net thermal input from the heat source. The available shaft power is the excess of the power turbine work over the compressor work needed in the power loop. The best power loop efficiency occurred at a compressor pressure ratio of 1.8, and the best cryo-loop performance was at a compressor pressure ratio of 2.1. Good individual cycle performance occurred over a fairly large range in compressor pressure ratio.

Klann, J. L.↗

Cryogenic Propellant Long-Term Storage With Zero Boil-Off

Significant boil-off losses from cryogenic propellant storage systems in long-duration space mission applications result in additional propellant and larger tanks. The potential propellant mass loss reductions with the Zero Boil-off (ZBO) concept are substantial; therefore, further exploration through technology programs has been initiated within NASA. A large-scale demonstration of the ZBO concept has been devised utilizing the Marshall Space Flight Center (MSFC) Multipurpose Hydrogen Test Bed (MHTB) along with a cryo-cooler unit. The ZBO concept consists of an active cryo-cooling system integrated with traditional passive thermal insulation. The cryo-cooler is interfaced with the MHTB and spraybar recirculation/mixer system in a manner that enables thermal energy removal at a rate that equals the total tank heat leak. The liquid hydrogen (LH2) is withdrawn from the tank, passed through a heat exchanger, and then the chilled liquid is sprayed back into the tank through a spraybar. The test series will be performed over a 20-30 day period. Tests will be conducted at multiple fill levels to demonstrate concept viability and to provide benchmark data to be used in analytical model development. In this paper the test set-up and test procedures are presented.

Hedayat, Ali↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryocrystallography

In the past we have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. From these images it was clear that a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. During these studies we used large volume crystals, which were clearly distinguished from the loop holding them. These large crystals, originally grown for neutron diffraction studies, were chosen deliberately to enhance the imaging. As an extension to this work, we used thermal imaging to study small crystals, held in a cryo- loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryo-cooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied .

Snell, Eddie H.↗

Minimizing Uncertainty in Cryogenic Surface Figure Measurement

A new facility at the Goddard Space Flight Center is designed to measure with unusual accuracy the surface figure of mirrors at cryogenic temperatures down to 12 K. The facility is currently configured for spherical mirrors with a radius of curvature (ROC) of 600 mm, and apertures of about 150 mm or less. The goals of the current experiment were to 1) Obtain the best possible estimate of test mirror surface figure, S(x,y) at 87 K and 20 K; 2) Obtain the best estimate of the cryo-change, Delta (x,y): the change in surface figure between room temperature and the two cryo-temperatures; and 3) Determine the uncertainty of these measurements, using the definitions and guidelines of the ISO Guide to the Expression of Uncertainty in Measurement. A silicon mirror was tested, and the cry-change from room temperature to 20K was found to be 3.7 nm rms, with a standard uncertainty of 0.23 nm in the rms statistic. Both the cryo-change figure and the uncertainty are among the lowest such figures yet published. This report describes the facilities, experimental methods, and uncertainty analysis of the measurements.

Blake, Peter↗

Launch-Off-Need Shuttle Hubble Rescue Mission: Medical Issues

The Space Shuttle Hubble repair mission (STS-125) is unique in that a rescue mission (STS-400) has to be ready to launch before STS-125 life support runs out should the vehicle become stranded. The shuttle uses electrical power derived from fuel cells that use cryogenic oxygen and hydrogen (CRYO) to run all subsystems including the Environmental Control System. If the STS-125 crew cannot return to Earth due to failure of a critical subsystem, they must power down all nonessential systems and wait to be rescued by STS-400. This power down will cause the cabin temperature to be 60 F or less and freeze the rest of the vehicle, preventing it from attempting a reentry. After an emergency has been declared, STS-125 must wait at least 7 days to power down since that is the earliest that STS-400 can be launched. Problem The delayed power down of STS-125 causes CYRO to be consumed at high rates and limits the survival time after STS-400 launches to 10 days or less. CRYO will run out sooner every day that the STS-400 launch is delayed (weather at launch, technical issues etc.). To preserve CRYO and lithium hydroxide (LiOH - carbon dioxide removal) the crew will perform no exercise to reduce their metabolic rates, yet each deconditioned STS-125 crewmember must perform an EVA to rescue himself. The cabin may be cold for 10 days, which may cause shivering, increasing the metabolic rate of the STS-125 crew. Solution To preserve LiOH, the STS-125 manifest includes nutrition bars with low carbohydrate content to maintain crew respiratory quotient (RQ) below 0.85 as opposed to the usual shuttle galley food which is rich in carbohydrates and keeps the RQ at approximately 0.95. To keep the crew more comfortable in the cold vehicle warm clothing also has been included. However, with no exercise and limited diet, the deconditioned STS-125 crew returning on STS-400 may not be able to egress the vehicle autonomously requiring a supplemented crash-and-rescue capability.

Hamilton, Douglas↗

The Integration and Test Program of the James Webb Space Telescope

The James Webb Space Telescope (JWST) project has entered into a comprehensive integration and test (I&T) program that over the coming years will assemble the various elements of the observatory (the Optical Telescope Element [OTE], the Integrated Science Instrument Module [ISIM], and the Spacecraft) and verify the readiness of the integrated system for launch. The I&T program as replanned for a 2018 launch readiness date has a number of interesting features. These include a streamlined ISIM cryo-vacuum test program at Goddard Space Flight Center, a streamlined OTIS (OTE + ISIM) test program at Johnson Space Center (JSC), the addition of a second Core cryo-vacuum thermal test, the enhancement of the Pathfinder program at JSC, and enhancement of the subsystem-level testing program for the MIRI cryo-cooler. These latter activities all serve to reduce the risk heading into the end-to-end optical and thermal testing of the telescope at JSC, leading to reduced cost and schedule risk for that critical activity. We report here on the overall I&T program for JWST and on the status of the hardware and plans that support it.

Kimble, Randy↗

The Crystal Structure of Coxsackievirus A21 and Its Interaction with ICAM-1

CVA21 and polioviruses both belong to the Enterovirus genus in the family of Picornaviridae, whereas rhinoviruses form a distinct picornavirus genus. Nevertheless, CVA21 and the major group of human rhinoviruses recognize intercellular adhesion molecule-1 (ICAM-1) as their cellular receptor, whereas polioviruses use poliovirus receptor. The crystal structure of CVA21 has been determined to 3.2 {angstrom} resolution. Its structure has greater similarity to poliovirus structures than to other known picornavirus structures. Cryo-electron microscopy (cryo-EM) was used to determine an 8.0 {angstrom} resolution structure of CVA21 complexed with an ICAM-1 variant, ICAM-1{sup Kilifi}. The cryo-EM map was fitted with the crystal structures of ICAM-1 and CVA21. Significant differences in the structure of CVA21 with respect to the poliovirus structures account for the inability of ICAM-1 to bind polioviruses. The interface between CVA21 and ICAM-1 has shape and electrostatic complementarity with many residues being conserved among those CVAs that bind ICAM-1.

36 MATERIALS SCIENCE↗