Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conditional shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

High-Temperature Multi-Process Sensor Development and Demonstration at Coalfired Power Plants

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Full-scale Demonstration of Multi-process Sensor at a Cycling PC-fired Boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Slow Strain Rate Testing of A537 Tank Wall Material

At Savannah River Site (SRS), High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion and/or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate will increase, while the hydroxide and nitrite concentration of the interstitial liquid will deplete and become insufficient to prevent the onset of corrosion attack. Tank blending and the addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite. However, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processing. This testing program was designed to examine the risk of SCC associated with utilizing the pitting factor (PF) and nitrite/nitrate (NO 2 - /NO 3 - ) ratio limits for handling dissolved salt solutions at an elevated temperature in the carbon steel waste tanks. The previously identified limits are a PF of 1.2 and an NO 2 - /NO 3 - ratio of 0.15. The results indicate that as long as the NO 2 - /NO 3 - ratio exceeds 0.1 and the PF is above approximately 0.8, there is a discernible safety margin between the open circuit potential (OCP) and the critical cracking potential (CCP) observed during applied potential testing. However, this margin, defined by the difference between the OCP and CCP, is relatively narrow, ranging from 0.1 to 0.25 volts. This small margin raises concerns about potential shifts in OCP during waste retrieval operations, which could inadvertently increase the risk of SCC if the OCP approaches or exceeds the CCP. These results confirm that dissolved salt solutions provide a potent chemistry that, under certain conditions, makes carbon steel susceptible to SCC. The next question to consider is the influence these results have on decisions for storage and retrieval of waste from the tanks. For Type III/IIIA waste tanks, the risk of SCC remains very low. First, and most importantly, the post-weld stress relief of the tanks has reduced the residual stress near the welds. Thus, without the stress component, SCC risk is minimized. The material of construction (A537 Carbon steel) for the Type III/IIIA tanks is superior to the steel in its resistance to SCC than the steel that was utilized for the Type I, II, and IV tanks (A285 carbon steel). From a chemistry control standpoint for a Type III/IIIA tank directly involved with handling dissolved salt solutions, the PF and NO 2 - /NO 3 - ratio limits may be utilized wherein chemistry control provides an extra layer of defense against SCC. Chemistry control for a Type III/IIIA tank minimizes the risk for a tank that may receive the dissolved salt solution, particularly if that tank is a Type I, II, or IV waste tank. On the other hand, if the dissolved salt solution is handled by a Type I, II, or IV waste tank the risk of SCC is real. The potent chemistry, absence of stress relief, and inferior material result in a condition that is conducive to cracking. Efforts should be made to either avoid transferring waste that may not meet the PF and NO 2 - /NO 3 - ratio criteria to one of these tanks or if it is unavoidable, take measures to minimize the consequences of a leak. As shown by these tests, even if the PF and NO 2 - /NO 3 - ratio criteria are met, there is a risk that the tank potential may be disturbed in the positive direction and the risk of SCC increase.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two Large-Scale Meteorological Patterns are Associated with Short-Duration Dry Spells in the Northeastern United States

Large-scale meteorological pattern (LSMP)–based analysis is used in a novel way to understand meteorological conditions before and during short-duration dry spells over the northeastern United States. These LSMPs are useful to assess models and select better-performing models for future projections. Dry-spell events are identified from histograms of consecutive dry days below a daily precipitation threshold. Events lasting 12 days or longer, which correspond to ~10% of dry-spell events, are examined. The 500-hPa stream-function anomaly fields for the first 12 days of each event are time averaged, and k -means clustering is applied to isolate the dry-spell-related LSMPs. The first cluster has a strong low pressure anomaly over the Atlantic Ocean, southeast of the region, and is more common in winter and spring. The second cluster has strong high pressure over east-central North America and is most common during autumn. Over the region, both clusters have negative specific humidity anomalies, negative integrated vapor transport from the north, and subsidence associated with a midlatitude jet stream dipole structure that reinforces upper-level convergence. Subsidence is supported by cold-air advection in the first cluster and the location on the east side of the lower-level high pressure in the second cluster. Extratropical cyclone storm tracks are generally shifted southward of the region during the dry spells. Individual events lie on a continuum between two distinct clusters. These clusters have similar local, but different remote, properties. Although dry spells occur with greater frequency during drought months, most dry spells occur during nondrought months. Significance Statement: This study examines the large-scale weather patterns and meteorological conditions associated with dry-spell events lasting at least 2 weeks while affecting the northeastern United States. A statistical approach groups events together on the basis of similar atmospheric features. We find two distinct sets of patterns that we call large-scale meteorological patterns. These patterns reduce moisture, foster localized sinking, and shift the storm track southward along the Atlantic seaboard, all of which reduce precipitation. Besides greater understanding, knowing the meteorological patterns during short-term dryness in the region provides an important tool to assess how well atmospheric models reproduce these specific patterns. More dry spells occur in non-drought months than in drought months, which means that dry spells can occur without preexisting drought conditions.

58 GEOSCIENCES↗

Determination of oxidation rates and volatile oxidation products for HTGR graphite matrix material exposed to steam atmospheres

High-temperature gas-cooled reactors (HTGRs) in operation use tristructural isotropic (TRISO) particles embedded in graphite and carbonized resin matrix to form the fuel element. This graphite matrix material serves as a supportive structural element, heat transfer medium, and neutron moderator. In HTGR designs, fuel compacts are exposed to helium coolant, which facilitates high outlet temperatures (750°C 2 O, 800°C 2 , and H 2 , are quantified in varied oxidant atmospheres using a coupled thermogravimetric analyzer and mass spectrometer. Furthermore, oxidation rates reported here for varied steam (H 2 O [g]) atmospheres are predominantly linear and comparable with literature values in the range of tested temperatures (800–1200°C). Changes in dominant matrix oxidation products from primarily CO to a mixture of CO, CO 2 , and H 2 were observed at higher temperatures (≥1000°C) and steam atmospheres (≥5 kPa pH 2 O). Kinetic data indicates that there was no shift in oxidation regime with chemical oxidation occurring at all temperatures and H2O (g) atmospheres tested. These data provide insight into the oxidation behavior of graphite matrix material and will inform future testing conditions, notably mixed atmospheric conditions, of HTGR fuel elements.

36 MATERIALS SCIENCE↗

Electroluminescence from Single-Walled Carbon Nanotubes with Quantum Defects

Individual single-walled carbon nanotubes with covalent sidewall defects have emerged as a class of photon sources whose photoluminescence spectra can be tailored by the carbon nanotube chirality and the attached functional group/molecule. Here we present electroluminescence spectroscopy data from single-tube devices based on (7, 5) carbon nanotubes, functionalized with dichlorobenzene molecules, and wired to graphene electrodes. We observe electrically generated, defect-induced emissions that are controllable by electrostatic gating and strongly red-shifted compared to emissions from pristine nanotubes. The defect-induced emissions are assigned to excitonic and trionic recombination processes by correlating electroluminescence excitation maps with electrical transport and photoluminescence data. At cryogenic conditions, additional gate-dependent emission lines appear, which are assigned to phonon-assisted hot-exciton electroluminescence from quasi-levels. Similar results were obtained with functionalized (6, 5) nanotubes. We also compare functionalized (7, 5) electroluminescence data with photoluminescence of pristine and functionalized (7, 5) nanotubes redox-doped using gold(III) chloride solution. This work shows that electroluminescence excitation is selective toward neutral defect-state configurations with the lowest transition energy, which in combination with gate-control over neutral versus charged defect-state emission leads to high spectral purity.

36 MATERIALS SCIENCE↗

Activation and Conversion of Methane to Syngas over ZrO 2 /Cu(111) Catalysts near Room Temperature

Enzymatic systems achieve the catalytic conversion of methane at room temperature under mild conditions. Here, in this study, varying thermodynamic and kinetic parameters, we show that the reforming of methane by water (MWR, CH 4 + H 2 O → CO + 3H 2 ) and the water-gas shift reaction (WGS, CO + H 2 O → H 2 + CO 2 ), two essential processes to integrate fossil fuels toward a H2 energy loop, can be achieved on ZrO 2 /Cu(111) catalysts near room temperature. Measurements of ambient-pressure X-ray photoelectron spectroscopy and mass spectrometry, combined with density functional calculations and kinetic Monte Carlo simulations, were used to study the behavior of the inverse oxide/metal catalysts. The superior performance is associated with a unique zirconia-copper interface, where multifunctional sites involving zirconium, oxygen, and copper work coordinatively to dissociate methane and water at 300 K and move forward the MWR and WGS processes.

03 NATURAL GAS↗

Remote sensing of cytotype and its consequences for canopy damage in quaking aspen

Abstract Mapping geographic mosaics of genetic variation and their consequences via genotype x environment interactions at large extents and high resolution has been limited by the scalability of DNA sequencing. Here, we address this challenge for cytotype (chromosome copy number) variation in quaking aspen, a drought‐impacted foundation tree species. We integrate airborne imaging spectroscopy data with ground‐based DNA sequencing data and canopy damage data in 391 km 2 of southwestern Colorado. We show that (1) aspen cover and cytotype can be remotely sensed at 1 m spatial resolution, (2) the geographic mosaic of cytotypes is heterogeneous and interdigitated, (3) triploids have higher leaf nitrogen, canopy water content, and carbon isotope shifts (δ 13 C) than diploids, and (4) canopy damage varies among cytotypes and depends on interactions with topography, canopy height, and trait variables. Triploids are at higher risk in hotter and drier conditions.

Blonder, Benjamin↗

The Dynamics of the Wide-angle Tailed (WAT) Galaxy Cluster A562

We present the first in-depth dynamical analysis of the archetypal wide-angle tailed (WAT) cluster A562. We have combined Gemini observations with archival data from the literature to form a sample of 76 cluster members and derived a mean redshift of 0.1088 ± 0.0004 and a velocity dispersion of 919 ± 116 km s{sup −1}. This relatively large velocity dispersion suggests either a very massive cluster (M {sub dyn} > 6.9 × 10{sup 14} M {sub ☉}) and/or a merger system. The merger model is supported by a non-Gaussian galaxy velocity distribution, an elongated spatial distribution of likely cluster members, and an elongated X-ray emitting gas. This scenario would generate the bulk flow motion of the intracluster medium that can exert enough ram pressure to bend the radio jets. Thus, our observations support the model in which a recent off-axis merger event produced the cluster wide conditions needed to shape the WAT in A562.

79 ASTRONOMY AND ASTROPHYSICS↗

VERA neutronics high-fidelity benchmark for a modern PWR core design

Nearly 20 years since the origin of the infamous 'Kord Smith Challenge', and after 10 years and hundreds of millions of dollars invested by the US Department of Energy into the development of the Virtual Environment for Reactor Applications (VERA), the capability to accurately simulate a modern pressurized water reactor (PWR) fuel cycle at the fuel rod level with high-fidelity Monte Carlo (MC) stochastic transport methods still evades us. The deterministic methods in VERA make approximations that allow it to be successfully benchmarked against measured data from hundreds of PWR fuel cycles, but none of these benchmarks provided information at the local fuel rod level or allowed quantification of these approximations' impact for modern PWR reload designs. Using MPACT to establish the estimated isotopic distributions and thermal hydraulic conditions in a recent and challenging reactor design, a 2D quarter-core benchmark problem was established and solved consistently with both MPACT, the 51-energy group deterministic transport solver in VERA, and Shift, the continuous-energy MC transport solver in VERA. Impacts of energy groups, ray spacing, and scattering treatment were evaluated. Though MPACT has been previously shown to perform well compared to MC methods for initial Cycle 1 cores with only fresh fuel, this is the first benchmark of MPACT for a challenging modern reload core with depleted fuel and burnable absorbers. This work establishes additional credibility for the methods in MPACT and highlights the efficiency of these methods relative to those in use by MC-based tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of ceria-supported metal-oxide (MO x /CeO 2 ) catalysts via a one-pot chemical vapor deposition (OP-CVD) technique: Structure and reverse water gas shift reaction study

Current synthesis techniques for metal oxide (MO x )-supported catalysts have certain limitations of undesired target loading, ineffective dispersion of active species over the surface, uncontrolled particle size of active species, and complicated synthesis steps. Here, we developed a one-pot chemical vapor deposition (OP-CVD) methodology; by using which a solid metal precursor forms a vapor in a controlled condition and gets supported over the surrounding matrix. The theoretical stability followed by experimental validation using TGA is crucial for selecting the metal precursors. Three simple steps viz. premixing, dispersion, and rapid fixation by calcination are involved in the catalyst development via the OP-CVD approach. This study solely focused on the synthesis of 3d transition MO x over ceria support. The physicochemical characterizations of the prepared catalysts were performed by XRD, ICP-OES, SEM-EDX, CO pulse chemisorption, XANES, and EXAFS analyses to understand the crystal structure of involved species, target metal loading, dispersion, and particle size and prove the feasibility and viability of OP-CVD. The prepared catalysts were further tested for reverse water gas shift (RWGS) reaction to link their structural information with activity. The RWGS reaction data showed that the CO activity and CO selectivity were metal - and metal precursor-dependent. Higher CO activity of > 0.1 mol/h g-cat was observed for Cu and Co-based catalysts, with CO selectivity of ~100 %. This study provides an opportunity to produce efficient supported catalysts in a convenient way, providing effective catalytic activity.

36 MATERIALS SCIENCE↗

Studies of Low and Intermediate Temperature Oxidation of Propane up to 100 Atm in a Supercritical-Pressure Jet-Stirred Reactor

Here, the low and intermediate temperature oxidation of propane has been investigated by using a novel supercritical pressure jet stirred reactor (SP-JSR) with and without 20% CO 2 additions at fuel lean and rich conditions at 10 and 100 atm and 500–1000 K. The mole fractions of C 3 H 8 , O 2 , CO, CO 2 , CH 2 O, C 2 H 4 , CH 3 CHO, and C 3 H 6 were quantified by using a micro-gas chromatograph (µ-GC). The experiment showed that different from that of 10 atm, at 100 atm only a weak negative temperature coefficient (NTC) behavior was observed because of the significant shift of the intermediate temperature HO 2 chemistry to lower temperature. In addition, at 100 atm, existing models in literatures could successfully capture the onset temperatures of the low and intermediate chemistry, while under-predict the fuel oxidation quantitatively and fail to capture the NTC behavior between 650 and 780 K at both fuel lean and rich conditions. Similar discrepancy was observed in studies of n-butane and dimethyl ether (DME) oxidations in literatures, implying that there existed large uncertainties in hierarchy model development of fuels with low temperature chemistries at extremely high pressures. Reaction pathways and sensitivity analyses showed that RO 2 competing reactions through (P1) RO 2 = QOOH, (P2) RO 2 = C 3 H 6 + HO 2 , (P3) RO 2 + CH 2 O/HO 2 = RO 2 H + HCO / O 2 dominated the low and intermediate temperature chemistries, followed by HO 2 / H 2 O 2 chemistry at 100 atm, which differed from the dominant pathway through QOOH consumption reactions at lower pressures. Especially, P3 is a new pathway of RO 2 consumption at high pressures, which was not observed in importance at low pressures. Special attention should be paid to the accurate computations of n-C 3 H 7 O 2 / i-C 3 H 7 O 2 + CH 2 O and n-C 3 H 7 O 2 / i-C 3 H 7 O 2 + in the P3 pathway and n-C 3 H 7 O 2 / i-C 3 H 7 O 2 decomposition reactions in the P2 pathway at high pressures.

33 ADVANCED PROPULSION SYSTEMS↗

Ammonolysis Under NH 3 –Limiting Conditions as a Pathway to Improved LaTiO 2 N Water Splitting Photoanodes

LaTiO 2 N is a promising intermediate band gap semiconductor for the water splitting reaction, a pathway to hydrogen fuel from solar energy. However, the photoelectrochemical (PEC) activity of the material is hindered by defects, particularly Ti(III) species, which promote photocarrier recombination. These defects are formed during the high-temperature ammonolysis reaction. Here we show that improved LaTiO 2 N materials can be synthesized under NH 3 -limiting conditions by introducing N 2 to lower the NH 3 partial pressure to0.13atm.This reduces the Ti(III) defect density in the material from 6.06 × 10 16 to ∼4.61 × 10 15 cm −3 , by a factor of 13, based on electron paramagnetic resonance (EPR) spectroscopy. Any remaining Ti(III) defects are localized at the LaTiO 2 N surface, according to X-ray photoelectron spectroscopy (XPS), due to the formation of a depletion layer in the semico. Optical absorption spectra of the improved LaTiO 2 N reveal a blue-shifted band gap absorption edge and a suppressed sub-band gap absorption. Defect removal also reduces a sub-band gap surface photovoltage feature visible in the 1.0 atm reference material. The improved LaTiO 2 N supports a 1.57 mA cm −2 water oxidation photocurrent at 1.23 V RHE under simulated sunlight conditions, and an enhanced quantum efficiency of 4.5% (400 nm) for photocatalytic oxygen evolution from aqueous silver nitrate solution. Stable PEC operation is observed for over 55 min. This confirms that ammonolysis under NH 3 -limiting conditions improves the solar energy conversion properties of LaTiO 2 N. The ability to control metal ion defects in oxynitrides by varying the ammonia partial pressure during ammonolysis might be generally useful for the preparation of metal nitrides and oxynitrides.

defects↗

Deciphering the Dynamic Balance Between Solvation Strength and Polysulfides Reaction Heterogeneity in Practical Lithium‐Sulfur Batteries

Achieving stable interfacial chemistry in lithium–sulfur batteries under practical conditions remains a key barrier to commercialization. Here, we demonstrate that interfacial dynamics can be effectively regulated by coupling solvation-power control with intrinsic heterogeneity of sulfur redox chemistry through the introduction of a weakly solvating fluorinated cosolvent, LIB 1200ET (1200ET). Compared with conventional fluorinated ethers, 1200ET efficiently shifts Li + solvation environment toward a more non-coordinated configuration at low volume fractions, enabling substantial solvation modulation without significantly impairing sulfur redox kinetics. This solvation transition weakens Li + –solvent interactions while strengthening Li + –anion and Li + –lithium polysulfide (LPS) coordination, suppressing LPS solubility and promoting reconstruction of solid–electrolyte interphase (SEI). Regulated LPS chemistry, together with 1200ET, leads to formation of a S 4+ -rich, LiF-reinforced SEI with enhanced ionic conductivity and mechanical robustness. Spatially resolved sulfur K-edge X-ray absorption spectroscopy on pouch cells reveals pronounced current-density-dependent chemical heterogeneity, distinguishing kinetically dominated and solvation-controlled regions. Under practical conditions (3.7 mg cm −2 sulfur loading, E/S = 6 µL mg −1 ), a single-layer pouch cell delivers 527 mAh g −1 over 200 cycles at C/3, while an Ah-level multilayer pouch cell achieves an energy density of 358 Wh kg −1 . These results establish non-coordinating cosolvent-driven solvation engineering as a scalable strategy for practical Li–S batteries.

36 MATERIALS SCIENCE↗

Linking groundwater variability to ecosystem carbon and water use efficiencies across India

Carbon use efficiency (CUE) and water use efficiency (WUE) are important indicators of ecosystem health, reflecting the balance between carbon uptake and allocation, and the relationship between carbon assimilation and water loss. Although India shows large spatiotemporal variation in water table depth (WTD), and increasing groundwater stress, the influence of WTD on ecosystem functioning remains underexplored. This study uses satellite-based, modeled, and in-situ datasets to (1) quantify variations in CUE and WUE under shallow (SWTD) and deep (DWTD) WTD conditions across six homogeneous meteorological regions (HMRs), (2) evaluate temporal roles of gross primary productivity (GPP), net primary productivity (NPP), and evapotranspiration (ET) in driving these efficiencies, and (3) examine temporal responses to WTD shifts. SWTD regions generally showed 12 to 18 % higher GPP, 10 to 15 % higher NPP, and 10 to 20 % higher ET than DWTD zones, especially in semi-arid croplands and forests, leading to 8 to 12 % higher CUE and WUE. However, in humid and heavily irrigated regions such as northeastern and hilly India, CUE was up to 10 % higher in DWTD zones, possibly due to reduced respiration and better soil aeration compared to SWTD areas affected by waterlogging. During the Kharif (wet) season, DWTD croplands in humid zones had higher efficiencies, while in the Rabi (dry) season, SWTD croplands in northern India benefited from irrigation and cooler temperatures. These results highlight strong influence of WTD on carbon and water use processes and support the need for region-specific groundwater strategies.

Carbon use efficiency↗