Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Evaluation of biliary anatomy in the caudate lobe using drip infusion cholangiography-computed tomography

Purpose: This study aimed to retrospectively evaluate the caudate branches (CBs), which are bile ducts originating from the caudate lobe (CL), using drip infusion cholangiography with computed tomography (DIC-CT). Methods: The confluence patterns of CBs were evaluated in 185 adult patients undergoing DIC-CT. The following bile duct features were evaluated: (a) number of depicted CBs; (b) identification of the caudate portion from which the CBs were derived; (c) identification of the confluence site of a CB; and (d) whether there was a difference in the confluence site of the CBs depending on the position of the right posterior hepatic duct (RPHD) and the portal vein (PV). Results: DIC-CT enabled detection of a total of 640 bile ducts from the CL in 185 patients, and the total number of CBs from the Spiegel lobe (SP), the paracaval portion, and the caudate process (CP) were 347 (54.2%), 112 (17.5%), and 181 (28.2%), respectively. In the SP, over 60% of CBs joined the left hepatic duct system (LHDS). The positional relationship between the RPHD and the PV was divided into a supra-portal course (n = 168) and an infra-portal course (n = 17). The number of CBs joining the LHDS was significantly different between a supra-portal course and an infra-portal course (p = 0.0484). Conclusion: CBs were depicted by DIC-CT in 98.9% of the subjects, and a detailed evaluation was possible. The number of CBs joining the LHDS was associated with the position of the RPHD and the PV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Direct Computed Tomography Venography in Predicting Inflow for Venous Reconstruction in Chronic Post-thrombotic Syndrome

Purpose: The purpose of this paper is to assess the applicability of direct computed tomography venography (DCTV) in assessing dominant inflow vein in the femoral confluence in extensive chronic iliofemoral venous obstruction, using venography as the gold standard. Methods: All DCTVs performed in symptomatic patients with previous iliofemoral deep vein thrombosis subsequently submitted to venography in the period from January 2014 to August 2018 were retrospectively reviewed. Two groups were defined depending on whether the femoral vein (FV) or the deep femoral vein (DFV) was the dominant inflow on venography in order to identify predictors of DFV as dominant inflow in DCTV. Statistical analysis was performed with SPSS V25. Results: A total of 30 DCTVs and subsequent venographies were reviewed. Venography identified the FV as the dominant inflow in 18 (60%) and the DFV in 12 (40%) patients. Predictors for DFV as dominant inflow were identified as follows: larger DFV diameter 50 mm and 250 mm below lesser trochanter (8.73 ± 4.34 mm vs. 11.9 ± 3.52 mm; p = 0.043 and 5.4 ± 3.90 mm vs. 8.90 ± 2.70 mm; p = 0.011); lower FV/DFV ratio 150 mm below lesser trochanter (11.39 ± 20.01 mm vs. 1.05 ± 0.47 mm; p = 0.043); and presence of FV scarring/synechiae, collaterals and abnormal wall thickness (p = 0.003, p = 0.003 and p < 0.0001). Conclusion: In cases of extensive chronic iliofemoral venous obstruction, especially when stent deployment into the DFV is entertained, the key to success is thorough pre-procedure planning focusing on choosing the access site. This study suggests DCTV is valuable in defining the dominant iliac vein inflow, but additional findings are necessary to validate these preliminary data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Ultrasound-Based (BAT) Prostate-Repositioning: A Three-Dimensional On-Line Fiducial-Based Assessment With Cone-Beam Computed Tomography

Purpose: To assess the accuracy of ultrasound-based repositioning (BAT) before prostate radiation with fiducial-based three-dimensional matching with cone-beam computed tomography (CBCT). Patients and Methods: Fifty-four positionings in 8 patients with {sup 125}I seeds/intraprostatic calcifications as fiducials were evaluated. Patients were initially positioned according to skin marks and after this according to bony structures based on CBCT. Prostate position correction was then performed with BAT. Residual error after repositioning based on skin marks, bony anatomy, and BAT was estimated by a second CBCT based on user-independent automatic fiducial registration. Results: Overall mean value (MV {+-} SD) residual error after BAT based on fiducial registration by CBCT was 0.7 {+-} 1.7 mm in x (group systematic error [M] = 0.5 mm; SD of systematic error [{sigma}] = 0.8 mm; SD of random error [{sigma}] = 1.4 mm), 0.9 {+-} 3.3 mm in y (M = 0.5 mm, {sigma} = 2.2 mm, {sigma} = 2.8 mm), and -1.7 {+-} 3.4 mm in z (M = -1.7 mm, {sigma} = 2.3 mm, {sigma} = 3.0 mm) directions, whereas residual error relative to positioning based on skin marks was 2.1 {+-} 4.6 mm in x (M = 2.6 mm, {sigma} = 3.3 mm, {sigma} = 3.9 mm), -4.8 {+-} 8.5 mm in y (M = -4.4 mm, {sigma} = 3.7 mm, {sigma} = 6.7 mm), and -5.2 {+-} 3.6 mm in z (M = -4.8 mm, {sigma} = 1.7 mm, {sigma} = 3.5mm) directions and relative to positioning based on bony anatomy was 0 {+-} 1.8 mm in x (M = 0.2 mm, {sigma} = 0.9 mm, {sigma} = 1.1 mm), -3.5 {+-} 6.8 mm in y (M = -3.0 mm, {sigma} = 1.8 mm, {sigma} = 3.7 mm), and -1.9 {+-} 5.2 mm in z (M = -2.0 mm, {sigma} = 1.3 mm, {sigma} = 4.0 mm) directions. Conclusions: BAT improved the daily repositioning accuracy over skin marks or even bony anatomy. The results obtained with BAT are within the precision of extracranial stereotactic procedures and represent values that can be achieved with several users with different education levels. If sonographic visibility is insufficient, CBCT or kV/MV portal imaging with implanted fiducials are recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mid-Ventilation Concept for Mobile Pulmonary Tumors: Internal Tumor Trajectory Versus Selective Reconstruction of Four-Dimensional Computed Tomography Frames Based on External Breathing Motion

Purpose: To evaluate the accuracy of direct reconstruction of mid-ventilation and peak-phase four-dimensional (4D) computed tomography (CT) frames based on the external breathing signal. Methods and Materials: For 11 patients with 15 pulmonary targets, a respiration-correlated CT study (4D CT) was acquired for treatment planning. After retrospective time-based sorting of raw projection data and reconstruction of eight CT frames equally distributed over the breathing cycle, mean tumor position (P{sub mean}), mid-ventilation frame, and breathing motion were evaluated based on the internal tumor trajectory. Analysis of the external breathing signal (pressure sensor around abdomen) with amplitude-based sorting of projections was performed for direct reconstruction of the mid-ventilation frame and frames at peak phases of the breathing cycle. Results: On the basis of the eight 4D CT frames equally spaced in time, tumor motion was largest in the craniocaudal direction, with 12 {+-} 7 mm on average. Tumor motion between the two frames reconstructed at peak phases was not different in the craniocaudal and anterior-posterior directions but was systematically smaller in the left-right direction by 1 mm on average. The 3-dimensional distance between P{sub mean} and the tumor position in the mid-ventilation frame based on the internal tumor trajectory was 1.2 {+-} 1 mm. Reconstruction of the mid-ventilation frame at the mean amplitude position of the external breathing signal resulted in tumor positions 2.0 {+-} 1.1 mm distant from P{sub mean}. Breathing-induced motion artifacts in mid-ventilation frames caused negligible changes in tumor volume and shape. Conclusions: Direct reconstruction of the mid-ventilation frame and frames at peak phases based on the external breathing signal was reliable. This makes the reconstruction of only three 4D CT frames sufficient for application of the mid-ventilation technique in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Internal Target Volume for Radiation Treatment Planning of Esophageal Cancer by Using 4-Dimensional Computed Tomography (4DCT)

Purpose: To determine an efficient strategy for the generation of the internal target volume (ITV) for radiation treatment planning for esophageal cancer using 4-dimensional computed tomography (4DCT). Methods and Materials: 4DCT sets acquired for 20 patients with esophageal carcinoma were analyzed. Each of the 4DCT sets was binned into 10 respiratory phases. For each patient, the gross tumor volume (GTV) was delineated on the 4DCT set at each phase. Various strategies to derive ITV were explored, including the volume from the maximum intensity projection (MIP; ITV{sub M}IP), unions of the GTVs from selected multiple phases ITV2 (0% and 50% phases), ITV3 (ITV2 plus 80%), and ITV4 (ITV3 plus 60%), as well as the volumes expanded from ITV2 and ITV3 with a uniform margin. These ITVs were compared to ITV10 (the union of the GTVs for all 10 phases) and the differences were measured with the overlap ratio (OR) and relative volume ratio (RVR) relative to ITV10 (ITVx/ITV10). Results: For all patients studied, the average GTV from a single phase was 84.9% of ITV10. The average ORs were 91.2%, 91.3%, 94.5%, and 96.4% for ITV{sub M}IP, ITV2, ITV3, and ITV4, respectively. Low ORs were associated with irregular breathing patterns. ITV3s plus 1 mm uniform margins (ITV3+1) led to an average OR of 98.1% and an average RVR of 106.4%. Conclusions: The ITV generated directly from MIP underestimates the range of the respiration motion for esophageal cancer. The ITV generated from 3 phases (ITV3) may be used for regular breathers, whereas the ITV generated from 4 phases (ITV4) or ITV3 plus a 1-mm uniform margin may be applied for irregular breathers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling pure methane hydrate dissociation using a numerical simulator from a novel combination of X-ray computed tomography and macroscopic data

The numerical simulator TOUGH+HYDRATE (T+H) was used to predict the transient pure methane hydrate (no sediment) dissociation data. X-ray computed tomography (CT) was used to visualize the methane hydrate formation and dissociation processes. A methane hydrate sample was formed from granular ice in a cylindrical vessel, and slow depressurization combined with thermal stimulation was applied to dissociate the hydrate sample. CT images showed that the water produced from the hydrate dissociation accumulated at the bottom of the vessel and increased the hydrate dissociation rate there. CT images were obtained during hydrate dissociation to confirm the radial dissociation of the hydrate sample. This radial dissociation process has implications for dissociation of hydrates in pipelines, suggesting lower dissociation times than for longitudinal dissociation. These observations were also confirmed by the numerical simulator predictions, which were in good agreement with the measured thermal data during hydrate dissociation. System pressure and sample temperature measured at the sample center followed the CH{sub 4} hydrate L{sub w}+H+V equilibrium line during hydrate dissociation. The predicted cumulative methane gas production was within 5% of the measured data. Thus, this study validated our simulation approach and assumptions, which include stationary pure methane hydrate-skeleton, equilibrium hydrate-dissociation and heat- and mass-transfer in predicting hydrate dissociation in the absence of sediments. It should be noted that the application of T+H for the pure methane hydrate system (no sediment) is outside the general applicability limits of T+H.

54 ENVIRONMENTAL SCIENCES↗

Anniversary Paper: Development of x-ray computed tomography: The role of Medical Physics and AAPM from the 1970s to present

The AAPM, through its members, meetings, and its flagship journal Medical Physics, has played an important role in the development and growth of x-ray tomography in the last 50 years. From a spate of early articles in the 1970s characterizing the first commercial computed tomography (CT) scanners through the ''slice wars'' of the 1990s and 2000s, the history of CT and related techniques such as tomosynthesis can readily be traced through the pages of Medical Physics and the annals of the AAPM and RSNA/AAPM Annual Meetings. In this article, the authors intend to give a brief review of the role of Medical Physics and the AAPM in CT and tomosynthesis imaging over the last few decades.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Dose Verification for Intensity-Modulated Radiation Therapy in the Radiological Physics Centre Head-and-Neck Phantom Using Optical Computed Tomography Scans of Ferrous Xylenol-Orange Gel Dosimeters

Purpose: To extend the Radiological Physics Centre (RPC) intensity-modulated radiation therapy dose verification protocol to three dimensions using optical computed tomography (CT) scans of ferrous xylenol-orange (FX) gels. Methods and Materials: The dosimetry insert in the RPC head-and-neck phantom was replaced with an FX cylindrical gel dosimeter. Two gels were calibrated, independently irradiated with 6-MV X-ray beams and scanned using laser and cone-beam (Vista{sup TM}) optical CT, respectively. For matching dose slices, measured dose distributions were compared with Pinnacle{sup 3} computed distributions. Results: Within high-dose regions and low gradients, doses measured using laser CT were 2% to 3% less than the computed dose, whereas with cone-beam CT they were 4% to 5% less. Inside the central 90% of the gel cylinder diameter, the fraction of voxels satisfying the two-dimensional gamma analysis (5% dose difference, 3-mm distance to agreement) with laser-beam- and cone-beam-measured dose distributions were 98.4% and 99.0%, respectively. A three-dimensional gamma analysis with cone-beam data revealed that 96.7% of voxels within the central 90% gel volume satisfied the above criteria. Within the axial and sagittal planes through the primary planning target volume (PTV), computed and measured doses using GAFChromic EBT film (RPC measured) and cone-beam scanned FX gel generally agreed. At equivalent points in the planning target volumes, computed, thermoluminescent dosimeter (RPC-measured), and gel point doses agreed to within 5.1% in absolute dose. Conclusions: Laser and cone-beam CT yield comparable dose distributions in high-dose regions. The RPC head phantom and optical CT-scanned FX gels can be used for accurate intensity-modulated radiation therapy dose verification in three dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography (CBCT) Hepatic Arteriography in Chemoembolization for Hepatocellular Carcinoma: Performance Depicting Tumors and Tumor Feeders

PurposeThis study was designed to analyze retrospectively the performance of cone-beam computed tomography (CBCT) hepatic arteriography in depicting tumors and their feeders and to investigate the related determining factors in chemoembolization for hepatocellular carcinoma (HCC).MethodsEighty-six patients with 142 tumors satisfying the imaging diagnosis criteria of HCC were included in this study. The performance of CBCT hepatic arteriography for chemoembolization per tumor and per patient was evaluated using maximum intensity projection images alone (MIP analysis) or MIP combined with multiplanar reformation images (MIP + MPR analysis) regarding the following three aspects: tumor depiction, confidence of tumor feeder detection, and trackability of tumor feeders. Tumor size, tumor enhancement, tumor location, number of feeders, diaphragmatic motion, portal vein enhancement, and hepatic artery to parenchyma enhancement ratio were regarded as potential determining factors.ResultsTumors were depicted in 125 (88.0 %) and 142 tumors (100 %) on MIP and MIP + MPR analysis, respectively. Imaging performances on MIP and MIP + MPR analysis were good enough to perform subsegmental chemoembolization without additional angiographic investigation in 88 (62.0 %) and 128 tumors (90.1 %) on per-tumor basis and in 43 (50 %) and 73 (84.9 %) on per-patient basis, respectively. Significant determining factors for performance in MIP + MPR analysis on per tumor basis were tumor size (p = 0.030), tumor enhancement (0.005), tumor location (p = 0.001), and diaphragmatic motion (p < 0.001).ConclusionsCBCT hepatic arteriography provided sufficient information for subsegmental chemoembolization by depicting tumors and their feeders in the vast majority of patients. Combined analysis of MIP and MPR images was essential to enhance the performance of CBCT hepatic arteriography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiotherapy for Prostate Cancer Using Kilovoltage Cone-Beam Computed Tomography: First Clinical Results

Purpose: To evaluate the first clinical results of an off-line adaptive radiotherapy (ART) protocol for prostate cancer using kilovoltage cone-beam computed tomography (CBCT) in combination with a diet and mild laxatives. Methods and Materials: Twenty-three patients began treatment with a planning target volume (PTV) margin of 10 mm. The CBCT scans acquired during the first six fractions were used to generate an average prostate clinical target volume (AV-CTV), and average rectum (AV-Rect). Using these structures, a new treatment plan was generated with a 7-mm PTV margin. Weekly CBCT scans were used to monitor the CTV coverage. A diet and mild laxatives were introduced to improve image quality and reduce prostate motion. Results: Twenty patients were treated with conform ART protocol. For these patients, 91% of the CBCT scans could be used to calculate the AV-CTV and AV-Rect. In 96% of the follow-up CBCT scans, the CTV was located within the average PTV. In the remaining 4%, the prostate extended the PTV by a maximum of 1 mm. Systematic and random errors for organ motion were reduced by a factor of two compared with historical data without diet and laxatives. An average PTV reduction of 29% was achieved. The volume of the AV-Rect that received >65 Gy was reduced by 19%. The mean dose to the anal wall was reduced on average by 4.8 Gy. Conclusions: We safely reduced the high-dose region by 29%. The reduction in irradiated volume led to a significant reduction in the dose to the rectum. The diet and laxatives improved the image quality and tended to reduce prostate motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sparsity Prior Computed Tomography Reconstruction Using a Nonstandard Simultaneous X-ray Acquisition Model

In this article we systematically evaluate the performance of several state-of-the-art, sparsity prior computed tomography (CT) reconstruction algorithms, using a nonstandard simultaneous x-ray acquisition method. Sparsity prior is an efficient strategy in CT reconstruction, relying on iterative algorithms such as the algebraic reconstruction technique to produce a crude reconstruction, based on which sparse approximation is performed. The simultaneous x-ray acquisition model ensures rapid capture of x-rays; however, it captures a significantly fewer number of attenuation measurements, and the projections are nonuniform. We propose a weighted average filter in the reconstruction framework to ensure better quality reconstruction by minimizing the effect of nonuniform projections. The performance of the state-of-the-art algorithms is analyzed with and without weighted averaging before sparse approximation, in simulated and real environments. Experiments in the simulated environment are conducted with and without the presence of noise. From the results, it is evident that sparsity prior algorithms are capable of producing cross-sectional reconstruction using the simultaneous x-ray acquisition model, and better reconstruction quality is achievable with the incorporation of weighted averaging in the reconstruction framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation

The aim of this study is to evaluate the impact of the patient dose due to the kilovoltage cone beam computed tomography (kV-CBCT) in a prostate intensity-modulated radiation therapy (IMRT). The dose distributions for the five prostate IMRTs were calculated using the Pinnacle3 treatment planning system. To calculate the patient dose from CBCT, phase-space beams of a CBCT head based on the ELEKTA x-ray volume imaging system were generated using the Monte Carlo BEAMnrc code for 100, 120, 130, and 140 kVp energies. An in-house graphical user interface called DOSCTP (DOSXYZnrc-based) developed using MATLAB was used to calculate the dose distributions due to a 360 deg. photon arc from the CBCT beam with the same patient CT image sets as used in Pinnacle3. The two calculated dose distributions were added together by setting the CBCT doses equal to 1%, 1.5%, 2%, and 2.5% of the prescription dose of the prostate IMRT. The prostate plan and the summed dose distributions were then processed in the CERR platform to determine the dose-volume histograms (DVHs) of the regions of interest. Moreover, dose profiles along the x- and y-axes crossing the isocenter with and without addition of the CBCT dose were determined. It was found that the added doses due to CBCT are most significant at the femur heads. Higher doses were found at the bones for a relatively low energy CBCT beam such as 100 kVp. Apart from the bones, the CBCT dose was observed to be most concentrated on the anterior and posterior side of the patient anatomy. Analysis of the DVHs for the prostate and other critical tissues showed that they vary only slightly with the added CBCT dose at different beam energies. On the other hand, the changes of the DVHs for the femur heads due to the CBCT dose and beam energy were more significant than those of rectal and bladder wall. By analyzing the vertical and horizontal dose profiles crossing the femur heads and isocenter, with and without the CBCT dose equal to 2% of the prescribed dose, it was found that there is about a 5% increase of dose at the femur head. Still, such an increase in the femur head dose is well below the dose limit of the bone in our IMRT plans. Therefore, under these dose fractionation conditions, it is concluded that, though CBCT causes a higher dose deposited at the bones, there may be no significant effect in the DVHs of critical tissues in the prostate IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-243: Possibility of Exposure Dose Reduction of Cone-Beam Computed Tomography in An Image Guided Patient Positioning System by Using Various Noise Suppression Filters

Purpose: To investigate the possibility of exposure dose reduction of the cone-beam computed tomography (CBCT) in an image guided patient positioning system by using 6 noise suppression filters. Methods: First, a reference dose (RD) and low-dose (LD)-CBCT (X-ray volume imaging system, Elekta Co.) images were acquired with a reference dose of 86.2 mGy (weighted CT dose index: CTDIw) and various low doses of 1.4 to 43.1 mGy, respectively. Second, an automated rigid registration for three axes was performed for estimating setup errors between a planning CT image and the LD-CBCT images, which were processed by 6 noise suppression filters, i.e., averaging filter (AF), median filter (MF), Gaussian filter (GF), bilateral filter (BF), edge preserving smoothing filter (EPF) and adaptive partial median filter (AMF). Third, residual errors representing the patient positioning accuracy were calculated as an Euclidean distance between the setup error vectors estimated using the LD-CBCT image and RD-CBCT image. Finally, the relationships between the residual error and CTDIw were obtained for 6 noise suppression filters, and then the CTDIw for LD-CBCT images processed by the noise suppression filters were measured at the same residual error, which was obtained with the RD-CBCT. This approach was applied to an anthropomorphic pelvic phantom and two cancer patients. Results: For the phantom, the exposure dose could be reduced from 61% (GF) to 78% (AMF) by applying the noise suppression filters to the CBCT images. The exposure dose in a prostate cancer case could be reduced from 8% (AF) to 61% (AMF), and the exposure dose in a lung cancer case could be reduced from 9% (AF) to 37% (AMF). Conclusion: Using noise suppression filters, particularly an adaptive partial median filter, could be feasible to decrease the additional exposure dose to patients in image guided patient positioning systems.

60 APPLIED LIFE SCIENCES↗

SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body.

60 APPLIED LIFE SCIENCES↗

Development of X-Ray Computed Tomography Image Quality Indicators, "IQIs"

The intent of this effort, which is funded through the NASA OSMA NDE Program, is to develop a methodology and tools to assess Computed Tomography (CT) system performance. In particular, our team has fabricated Image Quality Indicators (IQIs) using materials and internal features useful for assessing CT detectability limits, contrast sensitivity, and resolution. Unlike traditional 2D radiography IQIs, those for CT should be more conducive to volumetric datasets and of uniform aspect ratio cross-sections.

Additive Manufacturing↗

Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the porous structures of the green body and sintered biomedical titanium scaffolds with micro-computed tomography

The present research was aimed at gaining an understanding of the porous structure changes from the green body through water leaching and sintering to titanium scaffolds. Micro-computed tomography (micro-CT) was performed to generate 3D models of titanium scaffold preforms containing carbamide space-holding particles and sintered scaffolds containing macro- and micro-pores. The porosity values and structural parameters were determined by means of image analysis. The result showed that the porosity values, macro-pore sizes, connectivity densities and specific surface areas of the titanium scaffolds sintered at 1200 °C for 3 h did not significantly deviate from those of the green structures with various volume fractions of the space holder. Titanium scaffolds with a maximum specific surface area could be produced with an addition of 60–65 vol% carbamide particles to the matrix powder. The connectivity of pores inside the scaffold increased with rising volume fraction of the space holder. The shrinkage of the scaffolds prepared with > 50 vol% carbamide space holder, occurring during sintering, was caused by the reductions of macro-pore sizes and micro-pore sizes as well as the thickness of struts. In conclusion, the final porous structural characteristics of titanium scaffolds could be estimated from those of the green body. - Highlights: •Porous structures of green body and sintered titanium scaffolds was studied. •Porous structures of both samples were quantitatively characterized with micro-CT. •Porous structures of scaffolds could be controlled from the green body. •Shrinkage mechanisms of titanium scaffolds during sintering was established.

36 MATERIALS SCIENCE↗