Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION↗

Compact superconducting rf-dipole cavity designs for deflecting and crabbing applications

Over the years the superconducting parallel-bar design has evolved into an rf-dipole cavity with improved properties. The new rf-dipole design is considered for a number of deflecting and crabbing applications. Some of those applications are the 499 MHz rf separator system for the Jefferson Lab 12 GeV upgrade, the 400 MHz crabbing cavity system for the proposed LHC high luminosity upgrade, and the 750 MHz crabbing cavity for the medium energy electron-ion collider in Jefferson Lab. In this paper we present the optimized rf design in terms of rf performance including rf properties, higher order modes (HOM) properties, multipacting and multipole expansion for the above mentioned applications.

De Silva, Subashini↗

Minimizing Errant Beam at the Spallation Neutron Source

Over the years SNS has been optimizing the amount of errant beam pulses in the accelerator. The errant beam pulses can damage the superconducting cavities and thus lower the uptime of the accelerator. This talk will present the effort that has been made to lower the amount of errant beam pulses with new diagnostics, analysis of processes that cause errant beam, and the resulting lessons learned.

Peters, Charles C.↗

Optimization of cathodic arc deposition and pulsed plasma melting techniques for growing smooth superconducting Pb photoemissive films for SRF injectors

Superconducting photoinjectors have a potential to be the optimal solution for moderate and high current cw operating free electron lasers. For this application, a superconducting lead (Pb) cathode has been proposed to simplify the cathode integration into a 1.3 GHz, TESLA-type, 1.6-cell long purely superconducting gun cavity. In the proposed design, a lead film several micrometres thick is deposited onto a niobium plug attached to the cavity back wall. Traditional lead deposition techniques usually produce very non-uniform emission surfaces and often result in a poor adhesion of the layer. A pulsed plasma melting procedure reducing the non-uniformity of the lead photocathodes is presented. In order to determine the parameters optimal for this procedure, heat transfer from plasma to the film was first modelled to evaluate melting front penetration range and liquid state duration. The obtained results were verified by surface inspection of witness samples. The optimal procedure was used to prepare a photocathode plug, which was then tested in an electron gun. In conclusion, the quantum efficiency and the value of cavity quality factor have been found to satisfy the requirements for an injector of the European-XFEL facility.

42 ENGINEERING↗

Nonlinear switching dynamics in a photonic-crystal nanocavity

We report the experimental observation of nonlinear switching dynamics in an InP photonic crystal nanocavity. Usually, the regime of relatively small cavity perturbations is explored, where the signal transmitted through the cavity follows the temporal variation of the cavity resonance. When the cavity is perturbed by strong pulses, we observe several nonlinear effects, i.e., saturation of the switching contrast, broadening of the switching window, and even initial reduction of the transmission. The effects are analyzed by comparison with nonlinear coupled mode theory and explained in terms of large dynamical variations of the cavity resonance in combination with nonlinear losses. The results provide insight into the nonlinear optical processes that govern the dynamics of nanocavities and are important for applications in optical signal processing, where one wants to optimize the switching contrast.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-objective optimization of CEBAF heat load management and trip rates using AI/ML

The goal of this project is to investigate the use of RL to simultaneously optimize the cryogenic heat load and trip rate of the CEBAF linacs and make it generic to solve multi-objective problems that will enable its application at other Department of Energy (DOE) facilities with similar challenges. The existing approach optimizes the gradient distribution to minimize the trip rate and does not take into account the total heat load. A secondary objective of the project is the develop a framework to correct cavity quality curves (Q-curves) or RF-heat to Gradient relation curves for individual cavities. These curves are currently obtained using historical measurements and may have changed their behavior due to various events. Correction in these curves will allow us to accurately approximate the total RF heat generated by the linacs which is critical for the optimization.

43 PARTICLE ACCELERATORS↗

Physical Properties of Niobium and Specifications for Fabrication of Superconducting Cavities

It is important to distinguish among the properties of niobium, the ones that are related to the cavity's SRF performances, the formability of the material, and the mechanical behavior of the formed cavity. In general, the properties that dictate each of the above mentioned characteristics have a detrimental effect on one another and in order to preserve the superconducting properties without subduing the mechanical behavior, a balance has to be established. Depending on the applications, some parameters become less important and an understanding of the physical origin of the requirements might help in this optimization. SRF applications require high purity niobium (high RRR), but pure niobium is very soft from fabrication viewpoint. Moreover conventional fabrication techniques tend to override the effects of any metallurgical process meant to strengthen it. As those treatments dramatically affect the forming of the material they should be avoided. These unfavorable mechanical properties have to be accounted for in the design of the cavities rather than in the material specification. The aim of this paper is to review the significance of the important mechanical properties used to characterize niobium and to present the optimal range of values. Most of the following information deals with the specification of sheets for cell forming unless otherwise noted.

43 PARTICLE ACCELERATORS↗

Note: Studies on x-ray production in electron cyclotron resonance x-ray source based on ridged cylindrical cavity

A ridged cylindrical cavity has been designed using MICROWAVE STUDIO programme and it is used in the electron cyclotron resonance (ECR) x-ray source. The experimental parameters of the source are optimized for maximizing the x-ray output, and an x-ray dose rate of {approx}1000 {mu}Sv/h was observed at 20 cm from the port, for 500 W of microwave power without using any target. With the molybdenum target located at optimum position of the ridged cavity, the dose rate is found to be increased only by 10%. In order to understand the experimental observation, the electric field pattern of the cavity with the target placed at various radial distances is studied. In this note, the experimental and theoretical studies on ECR x-ray source using the ridged cylindrical cavity are presented.

43 PARTICLE ACCELERATORS↗

PTV-based IMPT optimization incorporating planning risk volumes vs robust optimization

Purpose: Robust optimization leads to intensity-modulated proton therapy (IMPT) plans that are less sensitive to uncertainties and superior in terms of organs-at-risk (OARs) sparing, target dose coverage, and homogeneity compared to planning target volume (PTV)-based optimized plans. Robust optimization incorporates setup and range uncertainties, which implicitly adds margins to both targets and OARs and is also able to compensate for perturbations in dose distributions within targets and OARs caused by uncertainties. In contrast, the traditional PTV-based optimization considers only setup uncertainties and adds a margin only to targets but no margins to the OARs. It also ignores range uncertainty. The purpose of this work is to determine if robustly optimized plans are superior to PTV-based plans simply because the latter do not assign margins to OARs during optimization. Methods: The authors retrospectively selected from their institutional database five patients with head and neck (H and N) cancer and one with prostate cancer for this analysis. Using their original images and prescriptions, the authors created new IMPT plans using three methods: PTV-based optimization, optimization based on the PTV and planning risk volumes (PRVs) (i.e., 'PTV+PRV-based optimization'), and robust optimization using the 'worst-case' dose distribution. The PRVs were generated by uniformly expanding OARs by 3 mm for the H and N cases and 5 mm for the prostate case. The dose-volume histograms (DVHs) from the worst-case dose distributions were used to assess and compare plan quality. Families of DVHs for each uncertainty for all structures of interest were plotted along with the nominal DVHs. The width of the 'bands' of DVHs was used to quantify the plan sensitivity to uncertainty. Results: Compared with conventional PTV-based and PTV+PRV-based planning, robust optimization led to a smaller bandwidth for the targets in the face of uncertainties {l_brace}clinical target volume [CTV] bandwidth: 0.59 [robust], 3.53 [PTV+PRV], and 3.53 [PTV] Gy (RBE){r_brace}. It also resulted in higher doses to 95% of the CTV {l_brace}D{sub 95%}: 60.8 [robust] vs 59.3 [PTV+PRV] vs 59.6 [PTV] Gy (RBE){r_brace}, smaller D{sub 5%} (doses to 5% of the CTV) minus D{sub 95%} {l_brace}D{sub 5%}- D{sub 95%}: 13.2 [robust] vs 17.5 [PTV+PRV] vs 17.2 [PTV] Gy (RBE){r_brace}. At the same time, the robust optimization method irradiated OARs less {l_brace}maximum dose to 1 cm{sup 3} of the brainstem: 48.3 [robust] vs 48.8 [PTV+PRV] vs 51.2 [PTV] Gy (RBE); mean dose to the oral cavity: 22.3 [robust] vs 22.9 [PTV+PRV] vs 26.1 [PTV] Gy (RBE); maximum dose to 1% of the normal brain: 66.0 [robust] vs 68.0 [PTV+PRV] vs 69.3 [PTV] Gy (RBE){r_brace}. Conclusions: For H and N cases studied, OAR sparing in PTV+PRV-based optimization was inferior compared to robust optimization but was superior compared to PTV-based optimization; however, target dose robustness and homogeneity were comparable in the PTV+PRV-based and PTV-based optimizations. The same pattern held for the prostate case. The authors' data suggest that the superiority of robust optimization is not due simply to its inclusion of margins for OARs, but that this is due mainly to the ability of robust optimization to compensate for perturbations in dose distributions within target volumes and normal tissues caused by uncertainties.

60 APPLIED LIFE SCIENCES↗

Helium refrigeration systems for super-conducting accelerators

Many of the present day accelerators are based on superconducting technology which requires 4.5-K or 2-K helium refrigeration systems. These systems utilize superconducting radio frequency (SRF) cavities and/or superconducting magnets which are packaged into vacuum vessels known as cryo-modules (CM’s). Many of the present day accelerators are optimized to operate primarily at around 2-K, requiring specialized helium refrigeration systems which are cost intensive to produce and to operate. Some of the cryogenic refrigeration system design considerations for these challenging applications are discussed.

43 PARTICLE ACCELERATORS↗

Transverse Periodic Beam Loading Effects in a Storage Ring

Uneven beam fill patterns in storage rings, such as gaps in the fill patterns, leads to periodic, or transient loading of the modes of the RF cavities. We show that an analogous effect can occur in the loading of a dipole cavity mode when the beam passes off the electrical center of the cavity mode. Although this effect is small, it results in a variation of the transverse offset of the beam along the bunch train. For ultralow emittance beams, such as optimized third generation light sources and damping rings, this effect results in a larger projected emittance of the beam compared with the single bunch emittance. The effect is particularly strong for the case when a strong dipole mode has been purposely added to the ring, such as a deflecting, or 'crab' cavity. We derive an approximate analytic solution for the variation of the beam-induced deflecting voltage along the bunch train.

43 PARTICLE ACCELERATORS↗

Effect of emitters on quantum state transfer in coupled cavity arrays

Over the last decade, conditions for perfect state transfer in quantum spin chains have been discovered and their experimental realizations addressed, as have their extensions to more complex geometries of coupled cavity-emitter arrays. In this paper we further consider such studies and situations in which quantum state transfer can occur with high fidelity, even when the cavity-cavity coupling rates and cavity-emitter interaction rates are comparable. This is accomplished through the development and use of a Monte Carlo approach to the inverse eigenvalue problem, which allows the determination of coupling rates which optimize quantum state transfer fidelity and subsequent time evolution of the polariton wave function through exact diagonalization of the resulting Jaynes-Cummings-Hubbard Hamiltonian. The effect of inhomogeneous emitter locations is also evaluated. Furthermore, our key results include the demonstration that our methodology can be used successfully to establish Hamiltonian parameters for high-fidelity state transfer in more general lattice geometries and excitation number sectors, and also a determination of the effects of fluctuations in those parameters about their optimal values.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Small-Molecule CD4-Mimics: Structure-Based Optimization of HIV-1 Entry Inhibition

We report the optimization, based on computational, thermodynamic, and crystallographic data, of a series of small-molecule ligands of the Phe43 cavity of the envelope glycoprotein gp120 of human immunodeficiency virus (HIV) has been achieved. Importantly, biological evaluation revealed that the small-molecule CD4 mimics (4–7) inhibit HIV-1 entry into target cells with both significantly higher potency and neutralization breadth than previous congeners, while maintaining high selectivity for the target virus. Their binding mode was characterized via thermodynamic and crystallographic studies.

60 APPLIED LIFE SCIENCES↗

Selective binding of choline by a phosphate-coordination-based triple helicate featuring an aromatic box

In nature, proteins have evolved sophisticated cavities tailored for capturing target guests selectively among competitors of similar size, shape, and charge. The fundamental principles guiding the molecular recognition, such as self-assembly and complementarity, have inspired the development of biomimetic receptors. In the current work, we report a self-assembled triple anion helicate (host 2) featuring a cavity resembling that of the choline-binding protein ChoX, as revealed by crystal and density functional theory (DFT)-optimized structures, which binds choline in a unique dual-site-binding mode. Here, this similarity in structure leads to a similarly high selectivity of host 2 for choline over its derivatives, as demonstrated by the NMR and fluorescence competition experiments. Furthermore, host 2 is able to act as a fluorescence displacement sensor for discriminating choline, acetylcholine, l-carnitine, and glycine betaine effectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a 140 GHz waveguide notch filter for millimeter-wave receiver module protection in fusion plasma diagnostics

A carefully designed waveguide-based millimeter-wave notch filter, operating at 140 GHz, safeguards plasma diagnostic instruments from gyrotron leakage. Here, utilizing cylindrical cavity resonators with aperture coupling, the filter efficiently resonates 140 GHz wave-power into the TE 11p mode, optimizing various geometrical parameters for practical fabrication and high-yield production. Thorough thermal analysis ensures its ability to handle power. The filter achieves outstanding performance with over 90 dB rejection at 140 GHz while providing low insertion loss over the passband (110–138 GHz), which is ideally suited for system-on-chip approach F-band diagnostic system applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Background Attenuation for Fielded Spectroscopic Detection Systems

Radiation detectors are often placed in positions difficult to shield from the effects of terrestrial background gamma radiation. This is particularly true in the case of Radiation Portal Monitor (RPM) systems, as their wide viewing angle and outdoor installations make them susceptible to radiation from the surrounding area. Reducing this source of background can improve gross-count detection capabilities in the current generation of non-spectroscopic RPM’s as well as source identification capabilities in the next generation of spectroscopic RPM’s. To provide guidance for designing such systems, the problem of shielding a general spectroscopic-capable RPM system from terrestrial gamma radiation is considered. This analysis is carried out by template matching algorithms, to determine and isolate a set of non-threat isotopes typically present in the commerce stream. Various model detector and shielding scenarios are calculated using the Monte-Carlo N Particle (MCNP) computer code. Amounts of nominal-density shielding needed to increase the probability of detection for an ensemble of illicit sources are given. Common shielding solutions such as steel plating are evaluated based on the probability of detection for 3 particular illicit sources of interest, and the benefits are weighed against the incremental cost of shielding. Previous work has provided optimal shielding scenarios for RPMs based on gross-counting measurements, and those same solutions (shielding the internal detector cavity, direct shielding of the ground between the detectors, and the addition of collimators) are examined with respect to their utility to improving spectroscopic detection.

36 MATERIALS SCIENCE↗

A NEW DIFFERENTIAL AND ERRANT BEAM CURRENT MONITOR FOR THE SNS* ACCELERATOR

A new Differential and errant Beam Current Monitor (DBCM) is being implemented for both the Spallation Neutron Source's Medium Energy Beam Transport (MEBT) and the Super Conducting Linac (SCL) accelerator sections. These new current monitors will abort the beam when the difference between two toroidal pickups exceeds a threshold. The MEBT DBCM will protect the MEBT chopper target, while the SCL DBCM will abort beam to minimize fast beam losses in the SCL cavities. The new DBCM will also record instances of errant beam, such as beam dropouts, to assist in further optimization of the SNS Accelerator. A software Errant Beam Monitor was implemented on the regular BCM hardware to study errant beam pulses. The new system will take over this functionality and will also be able to abort beam on pulse-to-pulse variations. Because the system is based on the FlexRIO hardware and programmed in LabVIEW FPGA, it will be able to abort beam in about 5 us. This paper describes the development, implementation, and initial test results of the DBCM, as well as errant beam examples.

beam current monitor↗

Factors Affecting Treatment Outcome in Elderly Head and Neck Cancer Patients: A Retrospective Pilot Study

Head and neck cancer (HNC), the fifth most common cancer worldwide, is a complicated category of diseases comprised of cancers of the oral cavity, oropharynx, nasopharynx, hypopharynx, and larynx. Management of HNC can be very complex, with surgery, chemotherapy, and radiation therapy often used in combination to achieve optimal results. The optimal combination of therapies to maximize patient survival and post-treatment quality of life is yet unclear. Only some prognostic factors for HNC are relatively well understood, whereas others are affected by conflicting results of their significance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗