Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “casing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

The LLWR's 2011 Environmental Safety Case - 12143

The Low Level Waste Repository (LLWR) is the United Kingdom's principal facility for the disposal of LLW. The LLWR recently submitted an Environmental Safety Case (ESC), which will support applications to regulatory and government authorities to dispose of LLW and to start to install final closure engineering. The ESC is a major submission, with important implications for the future of the LLWR and the United Kingdom's management of LLW. The paper describes the context of the ESC, the ESC, its results and conclusions, and its implementation. The description shows that our ESC is a modern safety case developed as a range of safety arguments concerning our management, scientific and technical understanding, optimisation of the facility, as well as assessment calculations. The LLWR's 2011 ESC is a major submission, with important implications for the future of the LLWR and the United Kingdom's management of LLW. The description given of the scope of the ESC shows that it is a modern safety case developed as a range of safety arguments concerning our management, scientific and technical understanding, optimisation of the facility, as well as assessment calculations. A number of key advances have been made since the previous submission. In particular, the 2011 ESC addresses the criticisms made by the regulator on the previous submission in 2002, including those relating to lack of demonstration of optimisation, high calculated doses and risks compared with guidance levels, treatment of coastal erosion, and treatment of uncertainty. The ESC is being reviewed by the environmental regulator and it is hoped that a new permit for disposal of LLW and installation of closure engineering, along with the appropriate planning permission, will be obtained during 2013. The ESC, including its proposed waste acceptance arrangements, is already being implemented by the LLWR where consistent with our current Permit. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implementing Stakeholders' Access to Expertise: Experimenting on Nuclear Installations' Safety Cases - 12160

In 2009 and 2010, the Institute for Nuclear Safety and Radiation Protection (IRSN) led two pilot actions dealing with nuclear installations' safety cases. One concerned the periodical review of the French 900 MWe nuclear reactors, the other concerned the decommissioning of a workshop located on the site of Areva's La Hague fuel-reprocessing plant site in Northwestern France. The purpose of both these programs was to test ways for IRSN and a small number of stakeholders (Non-Governmental Organizations (NGOs) members, local elected officials, etc.) to engage in technical discussions. The discussions were intended to enable the stakeholders to review future applications and provide valuable input. The test cases confirmed there is a definite challenge in successfully opening a meaningful dialogue to discuss technical issues, in particular the fact that most expertise reports were not public and the conflict that exists between the contrary demands of transparency and confidentiality of information. The test case also confirmed there are ways to further improvement of stakeholders' involvement. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Importance of Getting it Right - Lessons from the Failure and Subsequent Approval of the LLWR Environmental Safety Case - 16691

The Low Level Waste Repository (LLWR) in the UK submitted an Environmental Safety Case in 2002 which was rejected by the Environment Agency 3 years later. Almost a decade after the rejection, the LLWR submitted a completely different document which was approved in November 2015. This paper looks at the lessons learned from the failed submission and documents the strategy employed by the Site's new contractor to overcome both the challenging technical issues that led to the initial rejection and overcome the resistance to long term disposal by the local community. It will describe the journey it has taken to move from a flawed safety case, to a technically sound safety case, to one that is approved by the regulator, and accepted by the community. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculating Dose Release Factors to Obtain the Worst-Case Maximally Exposed Location by Sector

The aim of this project was to update the SRS Dose Release Factors (DRF's) for the Maximally Exposed Individual (MEI) for 20 area release points onsite. To update, potential MEIs now include onsite locations and modeled stack heights were updated to match onsite operations. The DRF's and MEI locations are used to ensure DOE and EPA compliance is met for dose standards. The Environmental Protection Agency (EPA) requires the use of the computer model CAP88 to estimate doses for demonstrating compliance with 40 CFR 61, the National Emission Standard for Hazardous Air Pollutants (NESHAP). The location of the maximally exposed individual (MEI) by sector and distance is required for execution of CAP88. The worst-case sector is the sector and distance where an offsite individual would receive the highest dose due to a potential release from a designated release location at a facility. The worst-case sector analysis addresses potential ground-level and stack-height releases from 20 areas of Savannah River Site (SRS). Weather patterns were analyzed at each of these areas relative to sixteen compass points. The analysis makes use of recently updated distance data and meteorological data. The computer model, CAP88 is EPA's software system used by the Department of Energy (DOE) to calculate the receptor dose due to routine atmospheric releases via a gaussian plume at the Savannah River Site (SRS). The dose-release factors (DRFs) are used to estimate the offsite and onsite dose from facility-specific releases and represent the dose to a receptor exposed to 1 Ci of a specified radionuclide being released into the atmosphere. The DRFs are simply a ratio of the TED to the release rate and, therefore, are directly scalable. The DRF values listed in the Appendix can be applied to expected release values from each area to estimate the potential dose to an individual adult at each location. NESHAP DRFs have been supplied to Environmental Compliance and Area Closure Projects (EC and ACP) for many years and are periodically updated to include changes in Cap88. estimate the potential dose to an individual adult at each location DRF in mrem Ci{sup -1} are estimated by modeling the total effective dose (TED) in mrem yr{sup -1} assuming an annual atmospheric release rate of 1 Ci yr-1 of the associated radionuclides. TED = Effective Dose (ED) + Committed Effective Dose (CED). TED = DRF/RR. Approach and Methods: Determine possible MEI locations Onsite/Offsite including buildings and farms; Determine the distances from the release area to the possible MEI location and the direction from the release to the MEI location; Using the most recent meteorological data (2007-2011) and parameters, run CAP88 for each release area for each compass sector and previously calculated distances to MEI locations using a 1 Ci release rate for tritium; Use the calculated the air concentration values to determine the MEI for each sector from CAP88. The relationship between air concentration and received dose is directly proportional and can be used to determine which locations to calculate DRF's and a dose for an MEI; The DRFs are found for each compass sector from 20 SRS release areas using CAP88-PC Version 4.0; Each location is calculated with ground level releases evaluated for each area for a list of radionuclides, some with and some without progenies; Compare the DRFs of the potential onsite MEIs to offsite MEIs. Based on the 2018 MEI Report, the Site worst case sector MEI is located 593 mW of B-Area. This MEI location represents a point along the main road that travels through a tract of land leased to the SC National Guard. While this location is estimated to have the highest exposure, minimal radioactivity is released from B-Area. In 2017, SRS requested and was approved by the EPA to change the location for modeling site releases from the Center of Site to H-Area, and to use six stack heights. H-Area emission account for approximately 90% of all radioactive operations onsite. The MEI for H-Area was found to be 11,458 m NNE which locates the Savannah River Ecology Lab Conference Center. Comparisons for 2018 data and 2014 shows the new methods of calculation are more conservative yet still remain well below the DOE 100 mrem limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test case selection procedure for simulation-assisted automation testing - 321

Simulation-assisted automation testing is an efficient tool for validating the automation systems for nuclear power plants. This paper presented a systematic procedure for selecting test cases for simulation-assisted automation testing. The procedure is relies on the plant's licensing framework and allows associating the test cases to the functional requirements in order to produce traceable test set for validation. The procedure is demonstrated with a case study concerning the automation tests of Loviisa NPP's automation renewal project. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

2013 Caliban and Prospero experiments for the study of the behavior of radiation protection instrumentations in case of a criticality accident - 14346

Experiments using the CALIBAN and PROSPERO reactors were performed in 2013 in the framework of a collaboration between IRSN and CEA. The objective was to provide data about the possibility to use information given by radiation protection instrumentations (RPI) in the case of a criticality accident. In that purpose, the behavior of RPI was studied for various kinetics of the reactors which simulated different starts of a criticality accident. The article presents the safety issues associated with these experiments, i.e. the possible use of information given by the RPI for the emergency response of a criticality accident (detection of the accident, triage of the personnel, follow-up of the accident and reentry). Then, one paragraph is dedicated to the presentation of the tested material. In addition, the CALIBAN and PROSPERO reactors are briefly described, followed by the performed experiments. The RPI are neither designed nor dedicated to be used in case of a criticality accident. However, the preliminary conclusion of the experiments performed in 2013 is that the tested RPI have a correct behavior for slow kinetic experiments performed with the PROSPERO reactor, but might give less reliable and accurate information for pulse experiments performed with the CALIBAN reactor. In the last case, they can nevertheless provide information that can be helpful for the emergency response and the limitation of the consequences of the criticality accident. However, if the RPI are included in the emergency response of a criticality accident (detection, triage, follow-up, reentry), emergency procedures should be adapted. Other experiments might be performed in order to confirm results and to extend the number of tested materials, in particular portable survey meters or contamination area monitors. (authors)

42 ENGINEERING↗

Repowering and Retrofitting of Solar Inverters: A Field Case Study [Slides]

A handful of large-scale photovoltaic (PV) plants have undergone retrofitting and/or repowering of inverters for a variety of reasons, such as rapid product life-cycle innovations with lack of reverse compatibility, original equipment manufacturers (OEMs) exiting the inverter business, weather damage, more lucrative revenue opportunities driven by high contractual offtake price, and so on. Insights has been collected via expert elicitation and relevant staff involved in these retrofitting/repowering at the case study site. Selecting and installing inverters from a different OEM at the commercially operating PV plant provides a unique opportunity to thoroughly document inverter retrofitting/repowering. The case study describes compatibility of mechanical, electrical, communications, and other important aspects. The goal is to provide a public case study that improves the general knowledge of the solar industry about what is involved in repowering/retrofitting a PV plant and how others can best prepare.

14 SOLAR ENERGY↗

Modeling input spaace for testing scientific computational software: a case study

An application of a method of test case generation for scientific computational software is presented. NEWTRNX, neutron transport software being developed at Oak Ridge National Laboratory, is treated as a case study. A model of dependencies between input parameters of NEWTRNX is created. Results of NEWTRNX model analysis and test case generation are evaluated.

97 MATHEMATICS AND COMPUTING↗

Characterization of wellbore casing corrosion product as a permeable porous medium

Leakage along wellbores is of concern for a variety of applications, including sub-surface fluid storage facilities, geothermal wells, and CO 2 storage wells. We have investigated whether corroded casing is permeable to gas and can serve as a leakage pathway along wellbores. Three specimens were prepared from laboratory steel plates corroded using different mechanisms to reflect different possible field conditions and produce a variety of corrosion rates. Single-phase gas flow measurements were made under a range of gas pressures to investigate flow in both the viscous and visco-inertial flow regimes. Tests were conducted at different confining stresses (range from 3.45 to 13.79 MPa) following both loading and unloading paths. The gas flow test results imply corroded casing can serve as a significant leakage path along the axis of a wellbore. Transmissivity was discovered to be sensitive to the variation in confining stress suggesting that the corrosion product is deformable. Gas slip factors and the coefficients of inertial resistance of the corrosion product were comparable to those available in the literature for other porous media. Post-test examination of the corrosion product revealed it to be a heterogeneous, mesoporous material with mostly non-uniform slit type porosity. There was no discernable difference in the composition of corrosion product from specimens corroded by different mechanisms.

02 PETROLEUM↗

WISE-CASING: Containment and Monitoring Institute (CaMI), Calgary, Canada FEM-DC Model

For the model calculation we applied EM3D using completion diagram of CaMI site and a background resistivity consistent with the borehole logs. It was also important to use the accurate position of the return electrode. We note that for the data fit the code also incorporated well casings for well INJ and the other observation well, either OB1 or OB2, in the calculation. In summary, we demonstrate here, for this particular case, that the DC results may be a reasonable approximation to the low frequency EM data collected at CaMI. If this approximation continues to hold, then the extreme computational efficiency offered by the hierarchical modeling used in the DC simulations will permit us to explore far more model complexity, especially the pervasive and troublesome data artifacts that arise when doing EM surveys in mature, culturally developed sites. In Brief, both the low frequency and DC simulation codes provided very consistent results that match the field data really well, indicating their capability to help monitoring borehole integrity with the low frequency EM method.

15 GEOTHERMAL ENERGY↗

Exploration Case Studies on OpenEI; NREL (National Renewable Energy Laboratory)

This poster details the goal of developing a database of geothermal case studies for future exploration efforts in new areas. The goal of this effort is to develop a template for geothermal case studies in a crowd-sourced platform to allow contributions from the entire geothermal community, and this should be broken down into queriable properties in order to be more helpful.

15 GEOTHERMAL ENERGY↗

Characterization factors and other air quality impact metrics: Case study for PM 2.5 -emitting area sources from biofuel feedstock supply

In this paper, we develop a framework and metrics for estimating the impact of emission sources on regulatory compliance and human health for applications in air quality planning and life cycle impact assessment (LCIA). Our framework is based on a pollutant's characterization factor (CF) and three new metrics: Available Regulatory Capacity for Incremental Emissions (ARCIE), Source CF Ratio, and Activity Health Impact (AHI) Ratio. ARCIE can be used to assess whether a receptor location has capacity to accommodate additional source emissions while complying with regulatory limits. We present CF as a midpoint indicator of health impacts per unit mass of emitted pollutant. Source CF Ratio enables comparison of potential new-source locations based on human health impacts. The AHI Ratio estimates the health impacts of a pollutant in relation to the utilization of the source for each unit of product or service. These metrics can be applied to any pollutant, energy source sector (e.g., agriculture, electricity), source type (point, line, area), and spatial modeling domain (nation, state, city, region). We demonstrate these metrics through a case study of fine particulate (PM 2.5 ) emissions from U.S. corn stover harvesting and local processing at various scales, representing steps in the biofuel production process. We model PM 2.5 formation in the atmosphere using a novel reduced-complexity chemical transport model called the Intervention Model for Air Pollution (InMAP). Through this case study, we present the first area-source PM 2.5 CFs that address the recommendations of several LCIA studies to establish spatially explicit CFs specific to an energy source sector or type. Overall, the framework developed in this work provides multiple new ways to consider the potential impacts of air emissions through spatially differentiated metrics.

09 BIOMASS FUELS↗

Environmental Thermodynamic Effects on Future Changes of Mesoscale Convective Systems and Isolated Deep Convection Over the US: A Case Study

Mesoscale convective systems (MCSs) and isolated deep convection (IDC) significantly influence local weather conditions and the hydrological cycle across the United States. Their future changes under warming is critical to the society. However, the exact impacts of thermodynamic environmental changes on them are difficult to resolve using climate model simulations which integrate both dynamic and thermodynamic factors. This study explores a theoretical modeling approach to isolate environmental thermodynamic effects on their future changes through a case study. For a 50-day period during the 2020 summer, a pair of convection-permitting model simulations indicate contrasting changes in MCSs and IDC between inland and coastal regions under pseudo global warming. Driven by the thermodynamic environments of these simulations, a single-column parcel model indicates a decrease in the frequency of IDC occurrences, along with increases in duration and precipitation amount under warming, attributable to rising most unstable convective available potential energy (MUCAPE), convective inhibition (MUCIN), and precipitable water (PW). A multi-column parcel model reveals contrasting changes in the frequency and mean area of MCSs between inland and coastal regions, underscoring the increase in mean MUCIN over inland regions and increases in mean MUCAPE and PW over coastal regions. The increase in mean MCS area over inland regions is linked to the interplay between accelerated gust fronts and enhanced subsidence strength, which is further traced to the unchanged mean MUCIN but increased mean MUCAPE in large-scale environments. In conclusion, these case study results suggest a major role of thermodynamic environmental changes in controlling characteristics of MCSs and IDC under warming.

Mesoscale convective system↗

Use cases of lossy compression for floating-point data in scientific data sets

Architectural and technological trends of systems used for scientific computing call for a significant reduction of scientific data sets that are composed mainly of floating-point data. Here, this article surveys and presents experimental results of currently identified use cases of generic lossy compression to address the different limitations of scientific computing systems. The article shows from a collection of experiments run on parallel systems of a leadership facility that lossy data compression not only can reduce the footprint of scientific data sets on storage but also can reduce I/O and checkpoint/restart times, accelerate computation, and even allow significantly larger problems to be run than without lossy compression. In conclusion, these results suggest that lossy compression will become an important technology in many aspects of high performance scientific computing. Because the constraints for each use case are different and often conflicting, this collection of results also indicates the need for more specialization of the compression pipelines.

97 MATHEMATICS AND COMPUTING↗

Case Study of a Californian Brewery to Potentially Use Concentrating Solar Power for Renewable Heat Generation

With the increasing relevance and acceptance of solar thermal for industrial process heat (IPH), a case study for a proposed concentrating solar power (CSP) integration into an existing Californian brewery is highlighted. The thermal generation from a 1 MWth solar field was modelled in the System Advisor Model (SAM), and the economics considered the viability of the project where different variables such as the installed solar field cost were investigated on metrics such as Net Present Value (NPV) and payback period. For the Base Case, without the 30% Investment Tax Credit (ITC), and using a 2017 Federal income tax rate of 35%, the project’s NPV reached $0 (i.e., the project becomes viable), when the installed solar field cost reached $158/m2. With the 30% ITC and 35% tax, the solar field installed cost is estimated at $324/m2 to obtain an NPV = $0. The biggest influences on project viability measured by NPV were the project life, Federal tax rate, and the solar field cost.

case study↗

IEA BESTEST Multi-Zone Non-Airflow In-Depth Diagnostic Cases: Preprint

This paper documents a set of in-depth diagnostic test cases for multi-zone heat transfer models that do not include the heat and mass transfer effects of airflow between zones. The multi-zone non-airflow test cases represent an extension to IEA BESTEST (Judkoff and Neymark 1995a).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Business Case for a Micro-Combined Heat and Power Fuel Cell System in Commercial Applications

Combined heat and power fuel cell systems (CHP-FCSs) provide consistent electrical power and hot water with greater efficiency and lower emissions than alternative sources. These systems can be used either as baseload, grid-connected, or as off-the-grid power sources. This report presents a business case for CHP-FCSs in the range of 5 to 50 kWe. Systems in this power range are considered micro-CHP-FCS. For this particular business case, commercial applications rather than residential or industrial are targeted. To understand the benefits of implementing a micro-CHP-FCS, the characteristics that determine their competitive advantage must first be identified. Locations with high electricity prices and low natural gas prices are ideal locations for micro-CHP-FCSs. Fortunately, these high spark spread locations are generally in the northeastern area of the United States and California where government incentives are already in place to offset the current high cost of the micro-CHP-FCSs. As a result of the inherently high efficiency of a fuel cell and their ability to use the waste heat that is generated as a CHP, they have higher efficiency. This results in lower fuel costs than comparable alternative small-scale power systems (e.g., microturbines and reciprocating engines). A variety of markets should consider micro-CHP-FCSs including those that require both heat and baseload electricity throughout the year. In addition, the reliable power of micro-CHP-FCSs could be beneficial to markets where electrical outages are especially frequent or costly. Greenhouse gas emission levels from micro-CHP-FCSs are 69 percent lower, and the human health costs are 99.9 percent lower, than those attributed to conventional coal-fired power plants. As a result, FCSs can allow a company to advertise as environmentally conscious and provide a bottom-line sales advantage. As a new technology in the early stages of adoption, micro-CHP-FCSs are currently more expensive than alternative technologies. As the technology gains a foothold in its target markets and demand increases, the costs will decline in response to improved manufacturing efficiencies, similar to trends seen with other technologies. Transparency Market Research forecasts suggest that the CHP-FCS market will grow at a compound annual growth rate of greater than 27 percent over the next 5 years. These production level increases, coupled with the expected low price of natural gas, indicate the economic payback period will move to less than 5 years over the course of the next 5 years. To better understand the benefits of micro-CHP-FCSs, The U.S. Department of Energy worked with ClearEdge Power to install fifteen 5-kWe fuel cells in the commercial markets of California and Oregon. Pacific Northwest National Laboratory is evaluating these systems in terms of economics, operations, and their environmental impact in real-world applications. As expected, the economic analysis has indicated that the high capital cost of the micro-CHP-FCSs results in a longer payback period than typically is acceptable for all but early-adopter market segments. However, a payback period of less than 3 years may be expected as increased production brings system cost down, and CHP incentives are maintained or improved.

CHP, business case↗