Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Evaluation of thermal helium beam and line-ratio fast diagnostic on the National Spherical Torus Experiment-Upgrade

A 1-D kinetic collisional radiative model (CRM) with state-of-the-art atomic data is developed and employed to simulate line emission to evaluate the Thermal Helium Beam (THB) diagnostic on NSTX-U. This diagnostic is currently in operation on RFX-mod, and it is proposed to be installed on NSTX-U. The THB system uses the intensity ratios of neutral helium lines 667.8, 706.5, and 728.1 nm to derive electron temperature (eV ) and density (cm –3 ) profiles. The purpose of the present analysis is to evaluate the applications of this diagnostic for determining fast (~4 μs) electron temperature and density radial profiles on the scrape-off layer (SOL) and edge regions of NSTX-U that are needed in turbulence studies. The diagnostic is limited by the level of detection of the 728.1 nm line, which is the weakest of the three. In conclusion, this study will also aid in future design of a similar 2-D diagnostic systems on the divertor.

97 MATHEMATICS AND COMPUTING↗

An analysis of the influence of impurities on fast particle attenuation and on fast ion spectral shape in LHD

Neutral particle fluxes measured by neutral particle analyzers can provide information about the ion temperature as well as the non-Maxwellian anisotropic ion distribution tails from neutral beam injection and ion cyclotron radio frequency heating. In the case of multidirectional diagnostics employing high resolution atomic energy spectrometers, the neutral atomic flux source is not localized in contrast to pellet charge exchange or diagnostic neutral beam methods. The correct interpretation of such measurements from plasma in a complex toroidally asymmetric geometry, like that of LHD, requires careful numerical modeling of the neutral flux formation. Previously a measured neutral flux calculation scheme was developed and was used for the LHD geometry and a suitable analytic expression for ionization cross sections {sigma}{sub s}{sup (z)}(E,n{sub e},T{sub e},Z{sub eff}) of impurities was formulated by Janev et al. [Nucl. Fusion 29, 2125 (1989)]. In this paper, the attenuation of fast particles by impurities is incorporated into the neutral flux calculation scheme and the influence of impurities on the calculated neutral flux spectra is shown. Finally, the behavior of the calculated and experimental suprathermal particle distributions is compared for pure hydrogen and for argon impurity seeded plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Latent diffusion can map beam loss to two-dimensional phase-space projections

Beam loss monitors (BLMs) and beam current monitors (BCMs) are ubiquitous at particle accelerators around the world. These simple devices provide noninvasive high-level beam measurements but give no insight into the detailed 6D (𝑥,𝑦,𝑧,𝑝 𝑥 ,𝑝 𝑦 ,𝑝 𝑧 ) beam phase-space distributions or dynamics. We show that generative conditional latent diffusion models can learn intricate patterns to solve the extreme inverse problem of mapping waveforms of tens of BLMs or BCMs along an accelerator to detailed 2D projections of a charged particle beam’s 6D phase-space density. This transformational method can be used at any particle accelerator to transform simple noninvasive devices into detailed beam phase-space diagnostics. We demonstrate this concept via multiparticle simulations of the high-intensity beam in the kilometer-long Los Alamos Neutron Science Center linear proton accelerator.

43 PARTICLE ACCELERATORS↗

The diagnostic system of the neutral beam injectors for ITER heating and current drive

The neutral beam injectors for ITER are designed to deliver hydrogen or deuterium atoms accelerated at 1 MV for a total power of 34 MW. Design of the neutral beam and of the ion source test facilities is presently ongoing. Among the various activities, also the definition and assessment of necessary diagnostics are being carried out. Within this framework, requirements and constraints of the diagnostic system will be discussed in the present paper with the aim of providing data relevant for protection, operation, characterization, and improvement of the performances of the test facilities. The definition of the most suitable locations for the diagnostics and of their preliminary integration into the mechanical design will be proposed. Proposals for the extraction of signals from the high voltage components will also be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impurity temperature correction factors for the transmission grating spectrometer in the TJ-II stellarator

Impurity ion temperature and velocity profiles are obtained across plasmas in the TJ-II stellarator by performing charge-exchange recombination spectroscopy with a diagnostic neutral beam injector. For this, a tridirectional (toroidal plus two poloidal opposing views) multichannel spectroscopic diagnostic, incorporating 12-way fiber arrays, a compact f/1.8 spectrograph, and a back-illuminated CCD, permits Doppler line shifts and widths (of the C VI line at 529.05 nm) to be determined with 1-2 cm spatial resolution. For good photon counting statistics under Li-coated wall conditions, 600 {mu}m diameter fibers collect and transmit light to curved 100 {mu}m wide input slits. When calibrated with a neon pencil lamp this entrance slit width results in a non-Gaussian instrumental function that, if not handled correctly, can result in systematically underestimated impurity temperatures. Here we develop and present correction factors for this effect for a range of conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomography of an ultrafast laser driven proton source

Using a multichannel Thomson spectrometer we have implemented a tomographic approach allowing the reconstruction of the emission characteristic of a laser driven proton source with high energy and spatial resolution. The results demonstrate the complexity of the temporal and spatial characteristics of such a source. The emitted proton beam, which is laminar and divergent at high energies, becomes convergent at low energies. This implies that a fraction of the proton beam having this kinetic energy is emitted in a collimated way from the target at the ''turning point'' between these two behaviors. Only a finite fraction of the target surface is contributing to the ion spectrum, which is measured at a specific angle within the beam cone. Therefore the momentum distribution of the protons in the emitted beam at any point in space can be controlled by determining the proton source area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermographic system with a laser scanning device

It is shown that laser photothermal radiometry (LPTR) in combination with laser beam scanning within the instantaneous field of view of a single-element photodetector can be used to develop a scanning thermal emission microscope. An expression is derived for estimating its temperature resolution. The results of calculations are presented and the factors influencing the spatial lateral resolution of the technique and the time of image formation with the help of an acousto-optical deflector are analysed. (laser applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of the focusing multi-slit ion optical system at RUssian Diagnostic Injector (RUDI)

The upgrade of the diagnostic neutral beam injector RUDI in 2010 was performed to increase the beam density at the focal plane in accordance with the requirements of charge-exchange recombination spectroscopy diagnostics. A new focusing ion-optical system (IOS) with slit beamlets and an enlarged aperture was optimized for 50% higher nominal beam current and reduced angular divergence with respect to the previous multi-aperture IOS version. The upgraded injector provides the beam current up to 3 A, the measured beam divergence in the direction along the slits is 0.35 deg. Additionally, the plasma generator was modified to extend the beam pulse to 8 s.

43 PARTICLE ACCELERATORS↗

Ion source research and development at University of Jyväskylä: Studies of different plasma processes and towards the higher beam intensities

Several ion source related research and development projects are in progress at the Department of Physics, University of Jyväskylä (JYFL). The work can be divided into investigation of the ion source plasma and development of ion sources, ion beams, and diagnostics. The investigation covers the Electron Cyclotron Resonance Ion Source (ECRIS) plasma instabilities, vacuum ultraviolet (VUV) and visible light emission, photon induced electron emission, and the development of plasma diagnostics. The ion source development covers the work performed for radiofrequency-driven negative ion source, RADIS, beam line upgrade of the JYFL 14 GHz ECRIS, and the development of a new room-temperature-magnet 18 GHz ECRIS, HIISI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Hardened Beam Instrumentations for Multi-mega-watt Beam Facilities

A beam instrumentation is an essential element for the successful operate particle accelerators in which various diagnostics and beam control systems are integrated into beam optics. However, the performance of beam instrumentation is often subject to constraints such as prompt radiation dose, integrated radiation dose, operation (ambient) temperature and humidity, available space, and strength of embedded electromagnetic fields at the monitoring point. These constraints will limit the dynamic range of operational beam parameters, like the maximum achievable beam power. A seamless R\&D effort to develop the radiation hardened beam instrumentation should be made for future multi-MW beam facilities. In this paper, we describes about a radiation hardened beam instrumentation based on the operational experience of the NuMI beam line.

43 PARTICLE ACCELERATORS↗

Characterization of intense ion beam energy density and beam induced pressure on the target with acoustic diagnostics

We have developed the acoustic diagnostics based on a piezoelectric transducer for characterization of high-intensity pulsed ion beams. The diagnostics was tested using the TEMP-4M accelerator (150 ns, 250–300 kV). The beam is composed of C{sup +} ions (85%) and protons, the beam energy density is 0.5–5 J/cm{sup 2} (depending on diode geometry). A calibration dependence of the signal from a piezoelectric transducer on the ion beam energy density is obtained using thermal imaging diagnostics. It is shown that the acoustic diagnostics allows for measurement of the beam energy density in the range of 0.1–2 J/cm{sup 2}. The dependence of the beam generated pressure on the input energy density is also determined and compared with the data from literature. The developed acoustic diagnostics do not require sophisticated equipment and can be used for operational control of pulsed ion beam parameters with a repetition rate of 10{sup 3} pulses/s.

43 PARTICLE ACCELERATORS↗

Diagnostics of the ITER neutral beam test facility

The ITER heating neutral beam (HNB) injector, based on negative ions accelerated at 1 MV, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on the ITER HNB. The RF source, where the H{sup -}/D{sup -} production is enhanced by cesium evaporation, will be monitored with thermocouples, electrostatic probes, optical emission spectroscopy, cavity ring down, and laser absorption spectroscopy. The beam is analyzed by cooling water calorimetry, a short pulse instrumented calorimeter, beam emission spectroscopy, visible tomography, and neutron imaging. Design of the diagnostic systems is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A confocal laser-induced fluorescence diagnostic with an annular laser beam

Here, in this work, we report an annular beam confocal laser-induced fluorescence (LIF) configuration, which allows for high spatial resolution measurements of plasma properties in plasma setups and sources with limited optical access. The proposed LIF configuration utilizes the annular laser beam generated by a pair of diffractive axicons. The LIF signal is collected along the main optical axis within the ring region. It is shown experimentally that at a focal distance of 300 mm, a spatial resolution of ~5.3 mm can be achieved. Using geometric optics estimations, we showed that ~1 mm resolution at the same focal distance could potentially be achieved by modifying laser beam parameters. This approaches the localization accuracy of conventional LIF collection methods (with crossing laser beam injection and fluorescence collection optical paths). Measurements of the ion velocity distribution function in an argon plasma using both the confocal LIF with an annular laser beam and conventional LIF demonstrate a satisfactory agreement. The proposed LIF setup has potential applications for diagnostics in various plasma processing equipment and plasma sources, such as hollow cathodes, microplasmas, electric propulsion, etc.

47 OTHER INSTRUMENTATION↗

Rarefied flow diagnostics using pulsed high-current electron beams

The use of high-current short-pulse electron beams in low-density gas flow diagnostics is introduced. Efficient beam propagation is demonstrated for pressure up to 300 microns. The beams, generated by low-pressure pseudospark discharges in helium, provide extremely high fluorescence levels, allowing time-resolved visualization in high-background environments. The fluorescence signal frequency is species-dependent, allowing instantaneous visualization of mixing flowfields.

Wojcik, Radoslaw M.↗

Electron beam dynamics in the DARHT-II linear induction accelerator

The DARHT-II linear induction accelerator (LIA) accelerates a 2-kA electron beam to more than 17 MeV. The beam pulse has a greater than 1.5-microsecond flattop region over which the electron kinetic energy is constant to within 1%. The beam dynamics are diagnosed with 21 beam-position monitors located throughout the injector, accelerator, and after the accelerator exit, where we also have beam imaging diagnostics. We discuss the tuning of the injector and accelerator, and present data for the resulting beam dynamics. We discuss the tuning procedures and other methods used to minimize beam motion, which is undesirable for its application as a bremsstrahlung source for multi-pulse radiography of exlosively driven hydrodynamic experiments. We also present beam stability measurements, which we relate to previous stability experiments at lower current and energy.

43 PARTICLE ACCELERATORS↗

Development of the gas puff charge exchange recombination spectroscopy (GP-CXRS) technique for ion measurements in the plasma edge

A novel charge-exchange recombination spectroscopy (CXRS) diagnostic method is presented, which uses a simple thermal gas puff for its donor neutral source, instead of the typical high-energy neutral beam. This diagnostic, named gas puff CXRS (GP-CXRS), is used to measure ion density, velocity, and temperature in the tokamak edge/pedestal region with excellent signal-background ratios, and has a number of advantages to conventional beam-based CXRS systems. Here we develop the physics basis for GP-CXRS, including the neutral transport, the charge-exchange process at low energies, and effects of energy-dependent rate coefficients on the measurements. The GP-CXRS hardware setup is described on two separate tokamaks, Alcator C-Mod and ASDEX Upgrade. Measured spectra and profiles are also presented. Profile comparisons of GP-CXRS and a beam based CXRS system show good agreement. Emphasis is given throughout to describing guiding principles for users interested in applying the GP-CXRS diagnostic technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cesium control and diagnostics in surface plasma negative ion sources

For efficient and reliable negative ion generation it is very important to improve a cesium control and diagnostics. Laser beam attenuation and resonance fluorescence can be used for measurement of cesium distribution and cesium control. Resonant laser excitation and two-photon excitation can be used for improved cesium ionization and cesium trapping in the discharge chamber. Simple and inexpensive diode lasers can be used for cesium diagnostics and control. Cesium migration along the surface is an important mechanism of cesium escaping. It is important to develop a suppression of cesium migration and cesium accumulation on the extraction system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Manipulation of Nonclassical Atomic Spin States

We report successful manipulation of nonclassical atomic spin states. We apply an off-resonant noncircularly-polarized light pulse to a measurement-induced squeezed spin state of a cold atomic ensemble. By changing the pulse duration, we clearly observe a rotation of the anisotropic quantum-noise distribution in good contrast with the case of manipulation of a coherent spin state where the quantum-noise distribution is always isotropic. This is an important step for quantum state tomography, quantum swapping, and precision spectroscopic measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗