Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis

Purpose: Matrix inversion tomosynthesis (MITS) uses linear systems theory and knowledge of the imaging geometry to remove tomographic blur that is present in conventional backprojection tomosynthesis reconstructions, leaving in-plane detail rendered clearly. The use of partial-pixel interpolation during the backprojection process introduces imprecision in the MITS modeling of tomographic blur, and creates low-contrast artifacts in some MITS planes. This paper examines the use of MITS slabs, created by averaging several adjacent MITS planes, as a method for suppressing partial-pixel artifacts. Methods: Human chest tomosynthesis projection data, acquired as part of an IRB-approved pilot study, were used to generate MITS planes, three-plane MITS slabs (MITSa3), five-plane MITS slabs (MITSa5), and seven-plane MITS slabs (MITSa7). These were qualitatively examined for partial-pixel artifacts and the visibility of normal and abnormal anatomy. Additionally, small (5 mm) subtle pulmonary nodules were simulated and digitally superimposed upon human chest tomosynthesis projection images, and their visibility was qualitatively assessed in the different reconstruction techniques. Simulated images of a thin wire were used to generate modulation transfer function (MTF) and slice-sensitivity profile curves for the different MITS and MITS slab techniques, and these were examined for indications of partial-pixel artifacts and frequency response uniformity. Finally, mean-subtracted, exposure-normalized noise power spectra (ENNPS) estimates were computed and compared for MITS and MITS slab reconstructions, generated from 10 sets of tomosynthesis projection data of an acrylic slab. The simulated in-plane MTF response of each technique was also combined with the square root of the ENNPS estimate to yield stochastic signal-to-noise ratio (SNR) information about the different reconstruction techniques. Results: For scan angles of 20 Degree-Sign and 5 mm plane separation, seven MITS planes must be averaged to sufficiently remove partial-pixel artifacts. MITSa7 does appear to subtly reduce the contrast of high-frequency 'edge' information, but the removal of partial-pixel artifacts makes the appearance of low-contrast, fine-detail anatomy even more conspicuous in MITSa7 slices. MITSa7 also appears to render simulated subtle 5 mm pulmonary nodules with greater visibility than MITS alone, in both the open lung and regions overlying the mediastinum. Finally, the MITSa7 technique reduces stochastic image variance, though the in-plane stochastic SNR (for very thin objects which do not span multiple MITS planes) is only improved at spatial frequencies between 0.05 and 0.20 cycles/mm. Conclusions: The MITSa7 method is an improvement over traditional single-plane MITS for thoracic imaging and the pulmonary nodule detection task, and thus the authors plan to use the MITSa7 approach for all future MITS research at the authors' institution.

60 APPLIED LIFE SCIENCES↗

TU-F-17A-04: Respiratory Phase-Resolved 3D MRI with Isotropic High Spatial Resolution: Determination of the Average Breathing Motion Pattern for Abdominal Radiotherapy Planning

Purpose: To develop a retrospective 4D-MRI technique (respiratory phase-resolved 3D-MRI) for providing an accurate assessment of tumor motion secondary to respiration. Methods: A 3D projection reconstruction (PR) sequence with self-gating (SG) was developed for 4D-MRI on a 3.0T MRI scanner. The respiration-induced shift of the imaging target was recorded by SG signals acquired in the superior-inferior direction every 15 radial projections (i.e. temporal resolution 98 ms). A total of 73000 radial projections obtained in 8-min were retrospectively sorted into 10 time-domain evenly distributed respiratory phases based on the SG information. Ten 3D image sets were then reconstructed offline. The technique was validated on a motion phantom (gadolinium-doped water-filled box, frequency of 10 and 18 cycles/min) and humans (4 healthy and 2 patients with liver tumors). Imaging protocol included 8-min 4D-MRI followed by 1-min 2D-realtime (498 ms/frame) MRI as a reference. Results: The multiphase 3D image sets with isotropic high spatial resolution (1.56 mm) permits flexible image reformatting and visualization. No intra-phase motion-induced blurring was observed. Comparing to 2D-realtime, 4D-MRI yielded similar motion range (phantom: 10.46 vs. 11.27 mm; healthy subject: 25.20 vs. 17.9 mm; patient: 11.38 vs. 9.30 mm), reasonable displacement difference averaged over the 10 phases (0.74mm; 3.63mm; 1.65mm), and excellent cross-correlation (0.98; 0.96; 0.94) between the two displacement series. Conclusion: Our preliminary study has demonstrated that the 4D-MRI technique can provide high-quality respiratory phase-resolved 3D images that feature: a) isotropic high spatial resolution, b) a fixed scan time of 8 minutes, c) an accurate estimate of average motion pattern, and d) minimal intra-phase motion artifact. This approach has the potential to become a viable alternative solution to assess the impact of breathing on tumor motion and determine appropriate treatment margins. Comparison with 4D-CT in a clinical setting is warranted to assess the value of 4D-MRI in radiotherapy planning. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-03: A Novel Method to Account for Ion Chamber Volume Averaging Effect in a Commercial Treatment Planning System Through Convolution

Purpose: Fourier-based deconvolution approaches used to eliminate ion chamber volume averaging effect (VAE) suffer from measurement noise. This work aims to investigate a novel method to account for ion chamber VAE through convolution in a commercial treatment planning system (TPS). Methods: Beam profiles of various field sizes and depths of an Elekta Synergy were collected with a finite size ion chamber (CC13) to derive a clinically acceptable beam model for a commercial TPS (Pinnacle{sup 3}), following the vendor-recommended modeling process. The TPS-calculated profiles were then externally convolved with a Gaussian function representing the chamber (σ = chamber radius). The agreement between the convolved profiles and measured profiles was evaluated with a one dimensional Gamma analysis (1%/1mm) as an objective function for optimization. TPS beam model parameters for focal and extra-focal sources were optimized and loaded back into the TPS for new calculation. This process was repeated until the objective function converged using a Simplex optimization method. Planar dose of 30 IMRT beams were calculated with both the clinical and the re-optimized beam models and compared with MapCHEC™ measurements to evaluate the new beam model. Results: After re-optimization, the two orthogonal source sizes for the focal source reduced from 0.20/0.16 cm to 0.01/0.01 cm, which were the minimal allowed values in Pinnacle. No significant change in the parameters for the extra-focal source was observed. With the re-optimized beam model, average Gamma passing rate for the 30 IMRT beams increased from 92.1% to 99.5% with a 3%/3mm criterion and from 82.6% to 97.2% with a 2%/2mm criterion. Conclusion: We proposed a novel method to account for ion chamber VAE in a commercial TPS through convolution. The reoptimized beam model, with VAE accounted for through a reliable and easy-to-implement convolution and optimization approach, outperforms the original beam model in standard IMRT QA verification.

07 ISOTOPE AND RADIATION SOURCES↗

Sci-Thur AM: YIS – 05: Prediction of lung tumor motion using a generalized neural network optimized from the average prediction outcome of a group of patients

Purpose: In image-guided adaptive radiotherapy systems, prediction of tumor motion is required to compensate for system latencies. However, due to the non-stationary nature of respiration, it is a challenge to predict the associated tumor motions. In this work, a systematic design of the neural network (NN) using a mixture of online data acquired during the initial period of the tumor trajectory, coupled with a generalized model optimized using a group of patient data (obtained offline) is presented. Methods: The average error surface obtained from seven patients was used to determine the input data size and number of hidden neurons for the generalized NN. To reduce training time, instead of using random weights to initialize learning (method 1), weights inherited from previous training batches (method 2) were used to predict tumor position for each sliding window. Results: The generalized network was established with 35 input data (∼4.66s) and 20 hidden nodes. For a prediction horizon of 650 ms, mean absolute errors of 0.73 mm and 0.59 mm were obtained for method 1 and 2 respectively. An average initial learning period of 8.82 s is obtained. Conclusions: A network with a relatively short initial learning time was achieved. Its accuracy is comparable to previous studies. This network could be used as a plug-and play predictor in which (a) tumor positions can be predicted as soon as treatment begins and (b) the need for pretreatment data and optimization for individual patients can be avoided.

60 APPLIED LIFE SCIENCES↗

Accuracy of the averaged description of the motion of charged particles in high-frequency fields

The accuracy of the averaged ponderomotive description of the motion of charged particles in smoothly inhomogeneous high-frequency electromagnetic fields in the nonrelativistic approximation is considered. Average equations are derived within the Hamilton perturbation theory using the technique of canonical transformations. Corrections to the ponderomotive potential, including inertial ones, i.e., those depending on the drift momentum, are found. It is shown that the change in the particle energy after the interaction with the field is exponentially small in the adiabaticity parameter gv/{omega}L.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Channeling of high-power radio waves under conditions of strong anomalous absorption in the presence of an averaged electron heating source

Strong anomalous absorption of a high-power radio wave by small-scale plasma inhomogeneities in the Earth's ionosphere can lead to the formation of self-consistent channels (solitons) in which the wave propagates along the magnetic field, but has a soliton-like intensity distribution across the field. The structure of a cylindrical soliton as a function of the wave intensity at the soliton axis is analyzed. Averaged density perturbations leading to wave focusing were calculated using the model proposed earlier by Vas'kov and Gurevich (Geomagn. Aeron. 16, 1112 (1976)), in which an averaged electron heating source was used. It is shown that, under conditions of strong electron recombination, the radii of individual solitons do not exceed 650 m.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the correlation parameters of the surface structure of disordered semiconductors by the two-dimensional DFA and average mutual information methods

The processes of self-organization of the surface structure of hydrogenated amorphous silicon are studied by the methods of fluctuation analysis and average mutual information on the basis of atomic-force-microscopy images of the surface. It is found that all of the structures can be characterized by a correlation vector and represented as a superposition of harmonic components and noise. It is shown that, under variations in the technological parameters of the production of a-Si:H films, the correlation properties of their structure vary as well. As the substrate temperature is increased, the formation of structural irregularities becomes less efficient; in this case, the length of the correlation vector and the degree of structural ordering increase. It is shown that the procedure based on the method of fluctuation analysis in combination with the method of average mutual information provides a means for studying the self-organization processes in any structures on different length scales.

36 MATERIALS SCIENCE↗

AWE-ML: Averaged Weights for Explainable Machine Learning v. 1.0

This software uses averaged weighted estimators to classify instances and then explicate the individual decision process in classification. The software has state of the art performance in accuracy, while maintaining full explainability. It does this by calculating hierarchically averaged probabilities for a large class of feature combinations and updating them ‘on-the-fly’. On the fly updating also allows the model to be accurate, relative to the total dataset, maintaining accuracy in real-time, without a need to retrain the classifier.

Agarwal, Sapan↗

The Method of Finite Averages

The Method of Finite Averages (MoFA) is a rigorous multiscale modeling methodology for efficiently modeling multi-physical phenomena in heterogeneous porous media. The code developed in this project aims to perform the numerical calculations required to formulate, implement, and verify MoFA models for Earth and Energy systems (i.e., model verification refers to performing fully-resolved simulations of the systems and comparing their results to those of the models). In general, MoFA transforms partial differential equations (PDEs) describing the fine-scale physics of a system into coupled ordinary differential equations (ODEs)---in time---that describe the coarse-scale---or "average"---physical behaviors of the system. This transformation significantly expedites system simulation, as the coarse-scale ODEs involve vastly fewer degrees of freedom than the fine-scale PDEs. The code developed under this project will allow users to 1.) generate system geometries and numerical meshes, 2.) solve the PDE and ODE systems required for MoFA model formulation and implementation, 3.) solve the PDE systems required to obtain fully-resolved simulation results for model verification, and 4.) compare and plot results (e.g., the model and fully-resolved simulation solutions, the error between the solutions, etc.).

Pietrzyk, KyleM [Lawrence Livermore National Labor↗

Design and characterization of “flow-cell” integrated-flow active cooling for high-average-power ceramic optics

We used COMSOL Multiphysics to design a prototype actively cooled “flow-cell” substrate targeted at high-average-power applications, fabricated the prototype from cordierite ceramic, and tested the substrate under load in our thermal loading test stand. Sub-aperture testing revealed average-power handling up to 3.88-W/cm 2 absorbed power density, in excellent agreement with model predictions. Gratings fabricated on 2-in.-diam cordierite coupons were subjected to laser-damage testing and showed a damage threshold of 250 mJ/cm 2 .

47 OTHER INSTRUMENTATION↗

Quantitative time-averaged gas and liquid distributions using x-ray fluorescence and radiography in atomizing sprays

A method for quantitative measurements of gas and liquid distributions is demonstrated using simultaneous x-ray fluorescence and radiography of both phases in an atomizing coaxial spray. Synchrotron radiation at 10.1 keV from the Advanced Photon Source at Argonne National Laboratory is used for x-ray fluorescence of argon gas and two tracer elements seeded into the liquid stream. Simultaneous time-resolved x-ray radiography combined with time-averaged dual-tracer fluorescence measurements enabled corrections for reabsorption of x-ray fluorescence photons for accurate, line-of-sight averaged measurements of the distribution of the gas and liquid phases originating from the atomizing nozzle.

absorption↗

High average power 88 W OPCPA system for high-repetition-rate experiments at the LCLS x-ray free-electron laser

Here, we present a 100 kHz, sub-20 fs optical parametric chirped-pulse amplifier (OPCPA) system delivering 88.6 W average power at a center wavelength of 800 nm. The seed pulses are derived from the pump laser via white-light continuum generation and are amplified in three non-collinear OPCPA stages. The final two high-power stages are pumped with a 661 W Yb:YAG InnoSlab amplifier. A simple and robust design is used for the OPCPA system to avoid thermal effects and enhance long-term stability, resulting in excellent beam quality and high conversion efficiency. To the best of our knowledge, this is the highest average power OPCPA system reported to date.

47 OTHER INSTRUMENTATION↗

RF Design of a High Average Beam-Power SRF Electron Source

There is a significant interest in developing high-average power electron sources, particularly in the area of electron sources integrated with Superconducting Radio Frequency (SRF) systems. For these systems, the electron gun and cathode parts are critical components for stable intensity and high-average powers. In this initial design study, we will present the design of a 9-cell accelerator cavity having a frequency of 1.3 GHz and the corresponding field optimization studies.

43 PARTICLE ACCELERATORS↗

What Do s- and p-Wave Neutron Average Radiative Widths Reveal

A first observation of two resonance-like structures at mass numbers 92 and 112 in the average capture widths of the p-wave neutron resonances relative to the s-wave component is interpreted in terms of a spin-orbit splitting of the 3p single-particle state into P{sub 3/2} and P{sub 1/2} components at the neutron separation energy. A third structure at about A = 124, which is not correlated with the 3p-wave neutron strength function, is possibly due to the Pygmy Dipole Resonance. Five significant results emerge from this investigation: (i) The strength of the spin-orbit potential of the optical-model is determined as 5.7 {+-} 0.5 MeV, (ii) Non-statistical effects dominate the p-wave neutron-capture in the mass region A = 85 - 130, (iii) The background magnitude of the p-wave average capture-width relative to that of the s-wave is determined as 0.50 {+-} 0.05, which is accounted for quantitatively in tenns of the generalized Fermi liquid model of Mughabghab and Dunford, (iv) The p-wave resonances arc partially decoupled from the giant-dipole resonance (GDR), and (v) Gamma-ray transitions, enhanced over the predictions of the GDR, are observed in the {sup 90}Zr - {sup 98}Mo and Sn-Ba regions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gatling gun: high average polarized current injector for eRHIC

This idea was originally developed in 2001 for, at that time, an ERL-based (and later recirculating-ring) electron-ion collider at JLab. Naturally the same idea is applicable for any gun requiring current exceeding capability of a single cathode. ERL-based eRHIC is one of such cases. This note related to eRHIC was prepared at Duke University in February 2003. In many case photo-injectors can have a limited average current - it is especially true about polarized photo-guns. It is know that e-RHIC requires average polarized electron current well above currently demonstrated by photo-injectors - hence combining currents from multiple guns is can be useful option for eRHIC.

43 PARTICLE ACCELERATORS↗

BIG TEN: A Large, Mixed-Uranium-Metal Cylindrical Core with 10% Average 235 U Enrichment, surrounded by a Thick 238 U Reflector

The idea for the Big Ten assembly was initially conceived in 1966. The assembly attained initial criticality at the Los Alamos Critical Experiment Facility (LACEF) in 1971. Big Ten is a cylindrical assembly with a core composed entirely of fissionable material in metal form, like most of the earlier critical assemblies at the LACEF. However, it is very large and massive; the name "Big Ten" reflects both its total mass of uranium (10 metric tons) and the average 235 U enrichment of its core (10%). The primary objective for Big Ten (References 1, 2, 3) was to measure effective cross sections in a neutron spectrum that, although still energetic, was appreciably softer than those in the earlier, smaller Los Alamos metal assemblies. Such a spectrum would resemble that of a liquid-metal fast breeder reactor (LMFBR). The desired flux spectrum could be produced by a critical assembly with fuel of considerably lower average enrichment. Therefore, the design demanded a much larger, reflected configuration. The metal core was surrounded by a 6-in.-thick depleted-uranium reflector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling an Application's Theoretical Minimum and Average Transactional Response Times

The theoretical minimum transactional response time of an application serves as a basis for the expected response time. The lower threshold for the minimum response time represents the minimum amount of time that the application should take to complete a transaction. Knowing the lower threshold is beneficial in detecting anomalies that are results of unsuccessful transactions. On the converse, when an application's response time falls above an upper threshold, there is likely an anomaly in the application that is causing unusual performance issues in the transaction. This report explains how the non-stationary Generalized Extreme Value distribution is used to estimate the lower threshold of an application's daily minimum transactional response time. It also explains how the seasonal Autoregressive Integrated Moving Average time series model is used to estimate the upper threshold for an application's average transactional response time.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Analytic computation of average energy of neutrons inducing fission

The objective of this report is to describe how I analytically computed the average energy of neutrons that induce fission in the bare BeRP ball. The motivation of this report is to resolve a discrepancy between the average energy computed via the FMULT and F4/FM cards in MCNP6 by comparison to the analytic results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗