Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ambient temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Effects of Internal and External Hydrogen on Inconel 718

Internal hydrogen embrittlement (IHE) and hydrogen environment embrittlement (HEE) tensile and bend crack growth tests were performed on Inconel 718. For the IHE tests, the specimens were precharged to approximately 90 ppm hydrogen by exposure to 34.5 MPa H2 at 650 C. The HEE tests were performed in 34.5 MPa H2. Parameters evaluated were test temperature, strain rate for smooth and notch specimen geometries. The strain rate effect was very significant at ambient temperature for both IHE and HEE and decreased with increasing temperatures. For IHE, the strain rate effect was neglible at 260'C, and for HEE the strain rate effect was neglible at 400 C. At low temperatures, IHE was more severe than HEE, and at high temperatures HEE was more severe than IHE with a cross over temperature about 350 C. At 350 C, the equilibrium hydrogen concentration in Inconel 718 is about 50% lower than the hydrogen content of the precharged IHE specimens. Dislocation hydrogen sweeping of surface absorbed hydrogen was the likely transport mechanism for increasing the hydrogen concentration in the HEE tests sufficiently to produce the same degree of embrittlement as that of the more highly hydrogen charged IHE specimens. The main IHE fracture characteristic was formation of large, brittle flat facets, which decreased with increasing test temperature. The IHE fracture matrix surrounding the large facets ranged between brittle fine faceted to microvoid ductility depending upon strain rate, specimen geometry as well as temperature. The HEE fractures were characteristically fine featured, transgranular and brittle with a significant portion forming a "saw tooth" crystallographic pattern. Both IHE and HEE fractures were predominantly along the {1 1 1) slip and twin boundaries. With respect to embrittlement mechanism, it was postulated that dislocation hydrogen sweeping and hydrogen enhanced localized plasticity were active in HEE and IHE for concentrating hydrogen along (1 1 1) slip and twin planes. Final brittle failure occurred by hydrogen induced planer decohesion.

Walter, R. J.↗

Power Electronics Being Developed for Deep Space Cryogenic Applications

Electronic circuits and systems designed for deep space missions need to operate reliably and efficiently in harsh environments that include very low temperatures. Spacecraft that operate in such cold environments carry a large number of heaters so that the ambient temperature for the onboard electronics remains near 20 C. Electronics that can operate at cryogenic temperatures will simplify system design and reduce system size and weight by eliminating the heaters and their associated structures. As a result, system development and launch cost will be reduced. At the NASA Glenn Research Center, an ongoing program is focusing on the development of power electronics geared for deep space low-temperature environments. The research and development efforts include electrical components design, circuit design and construction, and system integration and demonstration at cryogenic temperatures. Investigations are being carried out on circuits and systems that are targeted for use in NASA missions where low temperatures will be encountered: devices such as ceramic and tantalum capacitors, metal film resistors, semiconductor switches, magnetics, and integrated circuits including dc/dc converters, operational amplifiers, voltage references, and motor controllers. Test activities cover a wide range of device and circuit performance under simple as well as complex test conditions, such as multistress and thermal cycling. The effect of low-temperature conditions on the switching characteristics of an advanced silicon-on-insulator field effect transistor is shown. For gate voltages (VGS) below 2.6 V, drain currents at -190 C are lower than drain currents at room temperature (20 C).

Patterson, Richard L.↗

Preliminary results on the development of vacuum brazed joints for cryogenic wind tunnel aerofoil models

The results of initial experiments show that high-strength void-free bonds can be formed by vacuum brazing of stainless steels using copper and nickel-based filler metals. In Nitronic 40, brazed joints have been formed with strengths in excess of the yield strength of the parent metal, and even at liquid nitrogen temperatures the excellent mechanical properties of the parent metal are only slightly degraded. The poor toughness of 15-5 P.H. stainless steel at cryogenic temperatures is lowered even further by the presence of the brazed bonds investigated. It is highly unlikely that the technique would be used for any critical areas of aerofoil models intended for low-temperature service. Nevertheless, the potential advantages of this simplified method of construction still have attractions for use at ambient temperatures.

Wigley, D. A.↗

Atmospheric density, temperature and wind measurement techniques during the 1980 Energy Budget Campaign

Super Loki rocketsonde systems are described. The datasonde telemeters data to a ground station where ambient temperatures are calculated between 20 and 70 km. The sphere is a passive, radar tracked system which allows density to be calculated between 30 and 90 km. When flown simultaneously the systems give redundant data in the altitudes between 30 and 70 km. The datasonde has a balloon parachute that descends more slowly than a conventional parachute and is more stable. Because of launch constraints the datasondes reached very high apogees, leading to very fast descent velocities. Aerodynamic heating reduced thermistor sensitivity. Anomalous parachute behavior influenced wind sensing until a denser layer was reached. The spheres collapsed above 60 km altitude, but their data, combined with dropsonde data give significant results for 21 flights. These show that the stratosphere is colder than Cospar 72 model predictions and the mesosphere is warmer.

Schmidlin, F. J.↗

The 2021 room-temperature superconductivity roadmap

Designing materials with advanced functionalities is the main focus of contemporary solid-state physics and chemistry. Research efforts worldwide are funneled into a few high-end goals, one of the oldest, and most fascinating of which is the search for an ambient temperature superconductor (A-SC). The reason is clear: superconductivity at ambient conditions implies being able to handle, measure and access a single, coherent, macroscopic quantum mechanical state without the limitations associated with cryogenics and pressurization. This would not only open exciting avenues for fundamental research, but also pave the road for a wide range of technological applications, affecting strategic areas such as energy conservation and climate change. In this roadmap we have collected contributions from many of the main actors working on superconductivity, and asked them to share their personal viewpoint on the field. The hope is that this article will serve not only as an instantaneous picture of the status of research, but also as a true roadmap defining the main long-term theoretical and experimental challenges that lie ahead. Interestingly, although the current research in superconductor design is dominated by conventional (phonon-mediated) superconductors, there seems to be a widespread consensus that achieving A-SC may require different pairing mechanisms.

"Toward hot superconductivity"↗

Low Temperature Reflectance Spectra of Titan Tholins

Compositional interpretation of remotely obtained reflectance spectra of outer solar system surfaces is achieved by a variety of methods. These include matching spectral curves, matching spectral features, quantitative spectral interpretation, and theoretical modeling of spectra. All of these approaches rely upon laboratory measurements of one kind or another. The bulk of these laboratory measurements are obtained with the sample of interest at ambient temperatures and pressures. However, surface temperatures of planets, satellites, and asteroids in the outer solar system are significantly cooler than ambient laboratory conditions on Earth. The infrared spectra of many materials change as a function of temperature. As has been recently demonstrated it is important to assess what effects colder temperatures have on spectral properties and hence, compositional interpretations. Titan tholin is a solid residue created by energetic processing of H-, C-, and N-bearing gases. Such residues can also be created by energetic processing if the gases are condensed into ices. Titan tholin has been suggested as a coloring agent for several surfaces in the outer solar system. Here we report laboratory measurements of Titan tholin at a temperature of 100 K and compare these to measurements of the same sample near room temperature. At low temperature the absorption features beyond 1 micrometer narrow slightly. At wavelengths greater than approx. 0.8 micrometer the overall reflectance of the sample decreases slightly making the sample less red at low temperatures. We will discuss the implications of the laboratory measurements for interpretation of cold outer solar system surfaces.

Roush, T. L.↗

Valuation of Novel Waste Heat Sources and a Path Towards Adoption: Preprint

It is recognized that beneficial electrification of most space heating will be necessary to avert the worst consequences of climate change. Fifth generation district heating and cooling (5GDHC) networks operate at near-ambient temperatures and thus facilitate heating electrification, as well as the use of waste heat sources at a wide range of temperatures. In this paper, we analyze the potential of waste heat to supply the required heat to these networks and describe the business models that could expand the use of these waste heat sources. Showcase single family and commercial districts in the US are discussed to demonstrate emerging technologies, district infrastructure approaches, and third-party thermal utility funding models for these leading 5GDHC networks. As part of this work, heat flow and temperature profiles from five different types of waste heat sources are analyzed. An example district is used to examine the integration potential and to quantify the potential reduction in energy consumption. The results indicate that 5GDHC networks are highly suitable systems for utilizing low to moderate temperature waste heat sources. In the studied district, waste heat can cover a share of up to 66% of the heat supplied to the ambient loop and reduce the overall electricity consumption for heating by up to 51%, depending on the characteristics of the specific power, temperature, and type of waste heat source. Through their moderate operating temperatures and use of waste heat sources combined with third party financed infrastructure, 5GDHC districts have significant potential to reduce carbon emissions associated with space conditioning.

district energy↗

Solid State Carbon Monoxide Sensor

A means for detecting carbon monoxide which utilizes an un-heated catalytic material to oxidize carbon monoxide at ambient temperatures. Because this reaction is exothermic, a thermistor in contact with the catalytic material is used as a sensing element to detect the heat evolved as carbon monoxide is oxidized to carbon dioxide at the catalyst surface, without any heaters or external heating elements for the ambient air or catalytic element material. Upon comparison to a reference thermistor, relative increases in the temperature of the sensing thermistor correspond positively with an increased concentration of carbon monoxide in the ambient medium and are thus used as an indicator of the presence of carbon monoxide.

Upchurch, Billy T.↗

Biomimetic CO oxidation below -100 °C by a nitrate-containing metal-free microporous system

CO oxidation is of importance both for inorganic and living systems. Transition and precious metals supported on various materials can oxidize CO to CO 2 . Among them, few systems, such as Au/TiO 2 , can perform CO oxidation at temperatures as low as -70 °C. Living (an)aerobic organisms perform CO oxidation with nitrate using complex enzymes under ambient temperatures representing an essential pathway for life, which enables respiration in the absence of oxygen and leads to carbonate mineral formation. Herein, we report that CO can be oxidized to CO 2 by nitrate at -140 °C within an inorganic, nonmetallic zeolitic system. The transformation of NO x and CO species in zeolite as well as the origin of this unique activity is clarified using a joint spectroscopic and computational approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plume characteristics of single-stream and dual-flow conventional and inverted-profile nozzles at equal thrust

The plume velocity and temperature decay rates of single-stream, conventional dual-flow and inverted-profile dual-flow nozzles are compared at equal values of ideal thrust over a wide range of flow conditions. The comparisons are made in terms of constant velocity and temperature contour maps. The results show that both dual-flow nozzle types have much greater plume velocity and temperature decay rates than those of equivalent thrust single-stream nozzles when the respective secondary flows were at ambient temperature. With hot secondary flows, the inverted-profile dual-flow plumes decayed significantly faster than those of single-stream nozzles; however, the decay rates for the conventional dual-flow streams were about the same as those for the single-stream nozzles. Consequently, with hot secondary flows, the inverted-profile dual-flow plumes decayed much faster than the conventional dual-flow plumes at equal thrust.

Vonglahn, U. H.↗

Plume characteristics of single-stream and dual-flow conventional and inverted-profile nozzles at equal thrust

The plume velocity and temperature decay rates of single-stream, conventional dual-flow and inverted-profile dual-flow nozzles are compared at equal values of ideal thrust over a wide range of flow conditions. The comparisons are made in terms of constant velocity and temperature contour maps. The results show that both dual-flow nozzle types have much greater plume velocity and temperature decay rates than those of equivalent thrust single-stream nozzles when the respective secondary flows were at ambient temperature. With hot secondary flows, the inverted-profile dual-flow plumes decayed significantly faster than those of single-stream nozzles; however, the decay rates for the conventional dual-flow streams were about the same as those for the single-stream nozzles. Consequently, with hot secondary flows, the inverted-profile dual-flow plumes decayed much faster than the conventional dual-flow plumes at equal thrust.

Von Glahn, U. H.↗

6H-SiC Transistor Integrated Circuits Demonstrating Prolonged Operation at 500 C

The NASA Glenn Research Center is developing very high temperature semiconductor integrated circuits (ICs) for use in the hot sections of aircraft engines and for Venus exploration where ambient temperatures are well above the approximately 300 degrees Centigrade effective limit of silicon-on-insulator IC technology. In order for beneficial technology insertion to occur, such transistor ICs must be capable of prolonged operation in such harsh environments. This paper reports on the fabrication and long-term 500 degrees Centigrade operation of 6H-SiC integrated circuits based on epitaxial 6H-SiC junction field effect transistors (JFETs). Simple analog amplifier and digital logic gate ICs have now demonstrated thousands of hours of continuous 500 degrees Centigrade operation in oxidizing air atmosphere with minimal changes in relevant electrical parameters. Electrical characterization and modeling of transistors and circuits at temperatures from 24 degrees Centigrade to 500 degrees Centigrade is also described. Desired analog and digital IC functionality spanning this temperature range was demonstrated without changing the input signals or power supply voltages.

Neudeck, Philip G.↗

Cold Helium Pressurization for Liquid Oxygen/Liquid Methane Propulsion Systems: Fully-Integrated Hot-Fire Test Results

Hot-fire test demonstrations were successfully conducted using a cold helium pressurization system fully integrated into a liquid oxygen (LOX) / liquid methane (LCH4) propulsion system (Figure 1). Cold helium pressurant storage at near liquid nitrogen (LN2) temperatures (-275 F and colder) and used as a heated tank pressurant provides a substantial density advantage compared to ambient temperature storage. The increased storage density reduces helium pressurant tank size and mass, creating payload increases of ~35% for small lunar-lander sized applications. This degree of mass reduction also enables pressure-fed propulsion systems for human-rated Mars ascent vehicle designs. Hot-fire test results from the highly-instrumented test bed will be used to demonstrate system performance and validate integrated models of the helium and propulsion systems. A pressurization performance metric will also be developed as a means to compare different active pressurization schemes.

Morehead, R. L.↗

Insulation Test Cryostat with Lift Mechanism

A multi-purpose, cylindrical thermal insulation test apparatus is used for testing insulation materials and systems of materials using a liquid boil-off calorimeter system for absolute measurement of the effective thermal conductivity (k-value) and heat flux of a specimen material at a fixed environmental condition (cold-side temperature, warm-side temperature, vacuum pressure level, and residual gas composition). An inner vessel receives liquid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including upper and lower guard chambers and middle test vessel, is suspended from a lid of the vacuum canister. Each of the three chambers is filled and vented through a single feedthrough. All fluid and instrumentation feedthroughs are mounted and suspended from a top domed lid allowing easy removal of the cold mass. A lift mechanism allows manipulation of the cold mass assembly and insulation test article.

Fesmire, James E.↗

Characterization of Cycle-Aged Commercial NMC and NCA Lithium-ion Cells: I. Temperature-Dependent Degradation

Lithium-ion batteries are widely used in applications from consumer electronic devices to stationary energy storage. Appropriate management of batteries is challenging due to limited data on their performance and materials degradation. Previous studies have focused on characterization of single cells under specific operating conditions. In the present work, commercial 18650 lithium-ion cells with LiNi x Mn y Co 1-x-y O 2 (NMC) and LiNi x Co y Al 1-x-y O 2 (NCA) positive electrodes were characterized by a wide range of electrochemical and materials techniques after cycling at 15, 25, or 35 °C to ∼80% capacity. The NCA cells exhibit weak temperature dependence in their cycle aging and materials degradation. The NMC cells exhibited increased capacity fade and materials degradation as ambient temperature decreased. All cells exhibited loss of lithium inventory as their primary degradation mode. However, the NCA cells only showed evidence of solid electrolyte interphase (SEI) growth whereas the NMC cells showed signs of Li plating at 15 °C, transitioning to SEI growth at 35 °C. The NMC cells displayed signs of loss of active material at the positive electrode at lower temperatures, suggesting that Li plating is correlated to additional processes that increase the rate of degradation. These results highlight the importance of avoiding broad generalizations about Li-ion battery temperature dependence.

25 ENERGY STORAGE↗

Static force tests of a sharp leading edge delta-wing model at ambient and cryogenic temperatures with a description of the apparatus employed

A sharp leading edge delta-wing model was tested through an angle-of-attack range at Mach numbers of 0.75, 0.80, and 0.85 at both ambient and cryogenic temperatures in the Langley 1/3-meter transonic cryogenic tunnel. Total pressure was varied with total temperature in order to hold test Reynolds number constant at a given Mach number. Agreement between the aerodynamic data obtained at ambient and cryogenic temperatures indicates that flows with leading-edge vortex effects are duplicated properly at cryogenic temperatures. The test results demonstrate that accurate aerodynamic data can be obtained by using conventional force-testing techniques if suitable measures are taken to minimize temperature gradients across the balance and to keep the balance at ambient (warm) temperatures during cryogenic operation of the tunnel.

Kilgore, R. A.↗

Pressure Driven Alkane Dehydrogenation by Palladium Metal

Abstract Dehydrogenation of alkanes is of increasing importance in fulfilling global demand for olefins and offers a potential source of carbon‐neutral hydrogen as a co‐product. Currently commercial dehydrogenation processes occur at high‐temperatures (500–900 °C) which is energy intensive and results in side reactions and rapid coking of the catalysts. In addition, the hydrogen produced is often burned to maintain temperature and to inhibit the back reaction. Here, pressure is utilized as a parameter to enable novel chemical catalytic processes, and ambient‐temperature dehydrogenation of alkanes by palladium is observed at 50–100 MPa, with both hydrogen gas and olefins recovered on decompression. This reaction follows a fundamentally different path to current commercial high‐temperature low‐pressure dehydrogenation processes with the palladium catalyst reversibly forming a hydride intermediate.

08 HYDROGEN↗

Impact of soiling on Si and CdTe PV modules: Case study in different Brazil climate zones

Soiling, particulate accumulation on photovoltaic (PV) module surfaces, reduces the available solar resource and the resulting generated device power. This case-study summarizes initial results of 5-year research on the contrasting soiling conditions in the tropical, subtropical, and semi-arid climates in Brazil. A major objective is to present a case study of the effects of soiling on PV module performance in different Brazil climate zones that represent the primary areas for the current and expanding Brazil solar installations. For this, the paper presents methodologies to quantify the soiling ratio (SRatio) and soiling rate (SRate) for two representative commercial technologies, polycrystalline or multicrystalline silicon (mc-Si) and thin-film cadmium telluride (CdTe) modules, through soiling monitoring stations deployed in the selected climate regions. An aim is to add to the growing soiling-research knowledge base through addressing these key factors and their relationships to critical electrical, solar resource, thermal, and local meteorological and environmental parameters. This paper presents, evaluates, and compares soiling rates and losses in Belo Horizonte, Minas Gerais (Equatorial Tropical: 19.92° S, 43.99° W), Porto Alegre, Rio Grande do Sul (Humid-Subtropical: 30.05° S, 51.17° W), and Brotas de Macaúbas, Bahia (Semi-Arid: 12.00° S, 42.63° W). The results show that soiling is moderate in all 3-regions, for example with 0.1%/day < SRate < 0.2%/day for Belo Horizonte. Precipitation dominates the cleaning of the modules in the summertime in this climate zone, while it is the major factor year-round in Rio Grande do Sul. Wind is the major issue mitigating the soiling accumulation for the Bahia installation. The methodology incorporates several key refinements, including the normalization and adjustment for the meteorological parameters (temperature, irradiance, wind, precipitation). The evaluations include the region-specific differing effects of non-uniform soiling, natural cleaning, and ambient temperatures.

14 SOLAR ENERGY↗