Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Sea WiFS Technical Report Series: The fourth SeaWIFS Intercalibration Round-Robin Experiment (SIRREX-4), May 1995

This report documents the fourth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-4), which was held at the National Institute of Standards and Technology (NIST) on 3-10 May 1995. The agenda for SIRREX-4 was established by a consensus reached at the conclusion of SIRREX-3: there should be an emphasis on training and work to foster and encourage uniform use of accepted protocols for calibrating radiometric instruments in the laboratory. The goal was to host the activity in a setting where proper techniques could be discussed and demonstrated. It seemed appealing to split the day between morning lectures and afternoon laboratory exercises or practicals. The former gave the user community a chance to present what was important to them and discuss it with acknowledged experts in radiometry, while the latter presented a unique opportunity for training and evaluation in the presence of these same experts. The five laboratory sessions were concerned with (1) determining the responsivity of a spectroradiometer and the spectral radiance of an unknown integrating sphere source, (2) demonstrating spectral field calibration procedures for an integrating sphere using three different instruments, (3) measuring spectral radiance using the plaque method, (4) setting up and aligning lamp calibration transfer standards using the NIST specifications for irradiance measurements, and (5) characterizing radiometric instruments. In addition to documenting some supplemental studies performed outside the laboratory sessions, this report includes an evaluation of the hardware that has been used during the SIRREX activities plus a critical evaluation of SIRREX objectives.

Johnson, B. Carol↗

Designing an Exploration Atmosphere Prebreathe Protocol

Extravehicular activities (EVAs) at remote locations must maximize limited resources such as oxygen (O2) and also minimize the risk of decompression sickness (DCS). A proposed remote denitrogenation (prebreathe) protocol requires astronauts to live in a mildly hypoxic atmosphere at 8.2 psia while periodically performing EVAs at 4.3 psia. Empirical data are required to confirm that the protocol meets the current accept requirements: less than or equal to 15% incidence of Type I DCS, less than or equal to 20% incidence of Grade IV venous gas emboli (VGE), both at 95% statistical confidence, with no Type II DCS symptom during the validation trial. METHODS: A repeated measures statistical design is proposed in which groups of 6 subjects with physical characteristics similar to active-duty astronauts would first become equilibrated to an 8.2 psia atmosphere in a hypobaric chamber containing 34% O2 and 66% N2, over 48 h, and then perform 4 simulated EVAs at 4.3 psia over the next 9 days. In the equilibration phase, subjects undergo a 3-h 100% O2 mask prebreathe prior to and during a 5-min ascent to 8.2 psia to prevent significant tissue N2 supersaturation on reaching 8.2 psia. Masks would be removed once 34% O2 is established at 8.2 psia, and subjects would then equilibrate to this atmosphere for 48 h. The hypoxia is equivalent to breathing air at 1,220 meters (4,000 ft) altitude, just as was experienced in the shuttle 10.2 psia - 26.5% O2 staged denitrogenation protocol and the current ISS campout denitrogenation protocol. For simulated EVAs, each subject dons a mask and breathes 85% O2 and 15% N2 during a 3-min depressurization to 6.0 psia, holds for 15 min, and then completes a 3-min depressurization to 4.3 psia. The simulated EVA period starts when 6.0 psia is reached and continues for a total of 240 min (222 min at 4.3 psia). During this time, subjects will follow a prescribed repetitive activity against loads in the upper and lower body with mean metabolic rate approaching 1500 BTU/hr [378 kcal/hr (O2 consumption about 1.3 l(sub STPD)/min)] in ambulatory subjects. Noninvasive Doppler ultrasound bubble monitoring for VGE in the pulmonary artery will be performed on subjects by 2 Doppler Technicians at about 15 min intervals while at 4.3 psia. At the end of this period, a 15-min repressurization returns all subjects back to 8.2 psia and the cycle is repeated 3 additional times with a day of rest between simulated EVAs. RESULTS: With an assumed 1.5% probability of DCS [P(DCS)] and accounting for within-subject correlation, running the proposed study with 20 subjects has a 95% probability of meeting the accept criterion for DCS. But if the true probability of DCS is 3.0%, then 30 subjects would be needed to achieve about the same probability to meet our accept criterion. These results assume a standard deviation of 1.4 for the between-subjects random component of P(DCS) on a logit scale, which was estimated from a previous study.

Conkin, Johnny↗

Heat stress and a countermeasure in the Shuttle rescueman's suit

Rescue of the astronaut flight crew from a contingency landing may risk exposure of the rescue crew to toxic propellants spilling from potentially ruptured tanks in the crew module area. An Aquala dry diver's suit has been in service by the rescue team to preclude exposure, especially in the water rescue scenario. Heat stress has become a factor of concern in recent years when older and less physically-fit team members work in this suit. Methods: Field testing was initiated using fully instrumented rescue men in a simulated scenario to determine the extent of heat stress. Two tests were accomplished, one in the normal (N) configuration and one with a proposed cooling countermeasure, the Steele vest (S). Results: Heat stress was high as indicated by average rectal temperatures (Tre) of 38.28 degrees C(100.9 degrees F) after the 45 minute protocol. Slopes of the regression equations describing the increase in Tre with time were greater (P less than 0.05) with N (0.073 plus or minus .008) compared to S (0.060 plus or minus .007). Projection of time to the 38.89 degree C (102 degree F) limit was increased by 15.3 percent with the vest. Mean skin temperature (Tsk) was higher (P less than 0.05) in N (38.33 plus or minus .11 degrees C) compared to S (34.33 plus or minus .39 degrees C). Average heart rate was higher (P less than 0.05 in N than S. Sweat loss, as measured by weight loss, was more (P less than 0.05) for N (1.09 plus or minus .09 kg versus 0.77 plus or minus .06 kg). Air usage, while slightly less for S, was not statistically different. Conclusion: The use of the cool vest provided significant relief from thermal stress in spite of the addition of 3.4 kg (7.5 pounds) weight and some loss in mobility.

Doerr, D. F.↗

Trace Oxygen Measurements of Asteroid Sample Storage Desiccators

The Astromaterials Curation facility at the NASA Johnson Space Center is currently curating more than 120 g of carbonaceous asteroid Bennu material as well as over 500 mg of asteroid Ryugu [1 and 2]. These astromaterials are stored in isolating desiccators and gloveboxes under a continuous purge of pure (<1 ppm O 2 ) gaseous nitrogen. The oxygen and moisture concentrations in our OSIRIS-REx sample processing gloveboxes are continuously monitored via integrated sensors; however, our sample storage desiccators lack integrated oxygen and humidity sensors. In previous studies, we used PreSens Fibox 4 trace oxygen meters and optochemical PSt9 spot sensors to measure the oxygen concentrations in candidate asteroid sample containers that had been sealed in nitrogen; we determined that Eagle stainless steel containers inhibit the ingress of external oxygen for several weeks [3]. This optochemical sensor technology allowed us to take precise, contactless measurements within a trace range of 0 to 200 ppmv O 2 . The effectiveness of the trace oxygen sensors in our container experiments inspired us to utilize them to assess the performance of our desiccators that previously lacked trace oxygen monitoring. In this study, our goal was to determine the quality of the nitrogen purge in the isolating desiccator under normal operating conditions by measuring the trace oxygen content. Utilizing optochemical sensor technology, we determined how long the oxygen concentration takes to reach an equilibrium in the desiccator; that is, determine the rate at which the oxygen diffusion into the desiccator equals the rate at which oxygen diffuses out of the desiccator via N2 purge. Additionally, we wanted to determine the oxygen concentration at this equilibrium, the state in which our desiccators are in during normal operating conditions. We tested a custom three chamber desiccator manufactured by Germfree using a PSt9 trace oxygen sensor spot that was mounted into a ¼” National Pipe Tapered (NPT) metal flow-through cell and attached it to the desiccator exhaust. The desiccator consists of top, middle, and bottom isolating chambers. The top chamber door was opened for several minutes to simulate a sample exchange, it was sealed, and then purged ~15 Standard Cubic Feet per Hour (SCFH). Oxygen measurements were automatically recorded via the Fibox 4 trace oxygen meter in 5-minute intervals over the course of a 24-hour period. Our results indicate the desiccator reached an equilibrium value of 10-15 ppm O 2 after ~5 hours (Fig. 1). This data allows us to explore standards for purging and exchange protocols that can be applied to similar types of desiccators in Hayabusa2, OSIRIS-REx, and for sample return collections. The assessment of the internal gaseous compositions of desiccators also allows us to share with the community the N 2 environment in which many of our asteroid samples and hardware are securely curated. Future measurements will include other nitrogen flow rates and measuring the trace oxygen concentration as a function of time for the levels of the previous commercial desiccator in which the Hayabusa2 sample collection was stored. We will also analyze how long the desiccators hold N2 after being disconnected from their N2 source, an extended measurement for sample security reassurance.

Curation↗

"Smart" Sensor Module

An assembly that contains a sensor, sensor-signal-conditioning circuitry, a sensor-readout analog-to-digital converter (ADC), data-storage circuitry, and a microprocessor that runs special-purpose software and communicates with one or more external computer(s) has been developed as a prototype of "smart" sensor modules for monitoring the integrity and functionality (the "health") of engineering systems. Although these modules are now being designed specifically for use on rocket-engine test stands, it is anticipated that they could also readily be designed to be incorporated into health-monitoring subsystems of such diverse engineering systems as spacecraft, aircraft, land vehicles, bridges, buildings, power plants, oilrigs, and defense installations. The figure is a simplified block diagram of the "smart" sensor module. The analog sensor readout signal is processed by the ADC, the digital output of which is fed to the microprocessor. By means of a standard RS-232 cable, the microprocessor is connected to a local personal computer (PC), from which software is downloaded into a randomaccess memory in the microprocessor. The local PC is also used to debug the software. Once the software is running, the local PC is disconnected and the module is controlled by, and all output data from the module are collected by, a remote PC via an Ethernet bus. Several smart sensor modules like this one could be connected to the same Ethernet bus and controlled by the single remote PC. The software running in the microprocessor includes driver programs for operation of the sensor, programs that implement self-assessment algorithms, programs that implement protocols for communication with the external computer( s), and programs that implement evolutionary methodologies to enable the module to improve its performance over time. The design of the module and of the health-monitoring system of which it is a part reflects the understanding that the main purpose of a health-monitoring system is to detect damage and, therefore, the health-monitoring system must be able to function effectively in the presence of damage and should be capable of distinguishing between damage to itself and damage to the system being monitored. A major benefit afforded by the self-assessment algorithms is that in the output of the module, the sensor data indicative of the health of the engineering system being monitored are coupled with a confidence factor that quantifies the degree of reliability of the data. Hence, the output includes information on the health of the sensor module itself in addition to information on the health of the engineering system being monitored.

Mahajan, Ajay↗

Functional Imaging of Human Vestibular Cortex Activity Elicited by Skull Tap and Auditory Tone Burst

The current study characterizes brain activation in response to two modes of vestibular stimulation: skull tap and auditory tone burst. The auditory tone burst has been used in previous studies to elicit either the vestibulo-spinal reflex (saccular-mediated colic Vestibular Evoked Myogenic Potentials (cVEMP)), or the ocular muscle response (utricle-mediated ocular VEMP (oVEMP)). Some researchers have reported that air-conducted skull tap elicits both saccular and utricle-mediated VEMPs, while being faster and less irritating for the subjects. However, it is not clear whether the skull tap and auditory tone burst elicit the same pattern of cortical activity. Both forms of stimulation target the otolith response, which provides a measurement of vestibular function independent from semicircular canals. This is of high importance for studying otolith-specific deficits, including gait and balance problems that astronauts experience upon returning to earth. Previous imaging studies have documented activity in the anterior and posterior insula, superior temporal gyrus, inferior parietal lobule, inferior frontal gyrus, and the anterior cingulate cortex in response to different modes of vestibular stimulation. Here we hypothesized that skull taps elicit similar patterns of cortical activity as the auditory tone bursts, and previous vestibular imaging studies. Subjects wore bilateral MR compatible skull tappers and headphones inside the 3T GE scanner, while lying in the supine position, with eyes closed. Subjects received both forms of the stimulation in a counterbalanced fashion. Pneumatically powered skull tappers were placed bilaterally on the cheekbones. The vibration of the cheekbone was transmitted to the vestibular system, resulting in the vestibular cortical response. Auditory tone bursts were also delivered for comparison. To validate our stimulation method, we measured the ocular VEMP outside of the scanner. This measurement showed that both skull tap and auditory tone burst elicited vestibular evoked myogenic potentials, indicated by eye muscle responses. We further assessed subjects' postural control and its correlation with vestibular cortical activity. Our results provide the first evidence of using skull taps to elicit vestibular activity inside the MRI scanner. By conducting conjunction analyses we showed that skull taps elicit the same activation pattern as auditory tone bursts (superior temporal gyrus), and both modes of stimulation activate previously identified vestibular cortical regions. Additionally, we found that skull taps elicit more robust vestibular activity compared to auditory tone bursts, with less reported aversive effects. This further supports that the skull tap could replace auditory tone burst stimulation in clinical interventions and basic science research. Moreover, we observed that greater vestibular activation is associated with better balance control. We showed that not only the quality of balance (indicated by the amount of body sway) but also the ability to maintain balance for a longer time (indicated by the balance time) was associated with individuals' vestibular cortical excitability. Our findings support an association between vestibular cortical activity and individual differences in balance. In sum, we found that the skull tap stimulation results in activation of canonical vestibular cortex, suggesting an equally valid, but more tolerable stimulation method compared to auditory tone bursts. This is of high importance in longitudinal vestibular assessments, in which minimizing aversive effects may contribute to higher protocol adherence.

Noohi, F.↗

Advancing the Power and Utility of Server-Side Aggregation

During the upcoming Summer 2016 meeting of the ESIP Federation (July 19-22), OpenDAP will hold a Developers and Users Workshop. While a broad set of topics will be covered, a key focus is capitalizing on recent EOSDIS-sponsored advances in Hyrax, OPeNDAPs own software for server-side realization of the DAP2 and DAP4 protocols. These Hyrax advances are as important to data users as to data providers, and the workshop will include hands-on experiences of value to both. Specifically, a balanced set of presentations and hands-on tutorials will address advances in1.server installation,2.server configuration,3.Hyrax aggregation capabilities,4.support for data-access from clients that are HTTP-based, JSON-based or OGC-compliant (especially WCS and WMS),5.support for DAP4,6.use and extension of server-side computational capabilities, and7.several performance-affecting matters.Topics 2 through 7 will be relevant to data consumers, data providers andnotably, due to the open-source nature of all OPeNDAP softwareto developers wishing to extend Hyrax, to build compatible clients and servers, andor to employ Hyrax as middleware that enables interoperability across a variety of end-user and source-data contexts. A session for contributed talks will elaborate the topics listed above and embrace additional ones.

aggregation↗

High Data Rate Architecture (HiDRA)

One of the greatest challenges in developing new space technology is in navigating the transition from ground based laboratory demonstration at Technology Readiness Level 6 (TRL-6) to conducting a prototype demonstration in space (TRL-7). This challenge is com- pounded by the relatively low availability of new spacecraft missions when compared with aeronautical craft to bridge this gap, leading to the general adoption of a low-risk stance by mission management to accept new, unproven technologies into the system. Also in consideration of risk, the limited selection and availability of proven space-grade components imparts a severe limitation on achieving high performance systems by current terrestrial technology standards. Finally from a space communications point of view the long duration characteristic of most missions imparts a major constraint on the entire space and ground network architecture, since any new technologies introduced into the system would have to be compliant with the duration of the currently deployed operational technologies, and in some cases may be limited by surrounding legacy capabilities. Beyond ensuring that the new technology is verified to function correctly and validated to meet the needs of the end users the formidable challenge then grows to additionally include: carefully timing the maturity path of the new technology to coincide with a feasible and accepting future mission so it flies before its relevancy has passed, utilizing a limited catalog of available components to their maximum potential to create meaningful and unprecedented new capabilities, designing and ensuring interoperability with aging space and ground infrastructures while simultaneously providing a growth path to the future. The International Space Station (ISS) is approaching 20 years of age. To keep the ISS relevant, technology upgrades are continuously taking place. Regarding communications, the state-of-the-art communication system upgrades underway include high-rate laser terminals. These must interface with the existing, aging data infrastructure. The High Data Rate Architecture (HiDRA) project is designed to provide networked store, carry, and forward capability to optimize data flow through both the existing radio frequency (RF) and new laser communications terminal. The networking capability is realized through the Delay Tolerant Networking (DTN) protocol, and is used for scheduling data movement as well as optimizing the performance of existing RF channels. HiDRA is realized as a distributed FPGA memory and interface controller that is itself controlled by a local computer running DTN software. Thus HiDRA is applicable to other arenas seeking to employ next-generation communications technologies, e.g. deep space. In this paper, we describe HiDRA and its far-reaching research implications.

DTN↗

Intro and Recent Advances: Remote Data Access via OPeNDAP Web Services

During the upcoming Summer 2016 meeting of the ESIP Federation (July 19-22), OpenDAP will hold a Developers and Users Workshop. While a broad set of topics will be covered, a key focus is capitalizing on recent EOSDIS-sponsored advances in Hyrax, OPeNDAPs own software for server-side realization of the DAP2 and DAP4 protocols. These Hyrax advances are as important to data users as to data providers, and the workshop will include hands-on experiences of value to both. Specifically, a balanced set of presentations and hands-on tutorials will address advances in1.server installation,2.server configuration,3.Hyrax aggregation capabilities,4.support for data-access from clients that are HTTP-based, JSON-based or OGC-compliant (especially WCS and WMS),5.support for DAP4,6.use and extension of server-side computational capabilities, and7.several performance-affecting matters. Topics 2 through 7 will be relevant to data consumers, data providers and notably, due to the open-source nature of all OPeNDAP software to developers wishing to extend Hyrax, to build compatible clients and servers, and/or to employ Hyrax as middleware that enables interoperability across a variety of end-user and source-data contexts. A session for contributed talks will elaborate the topics listed above and embrace additional ones.

hyrax↗

Ultra Pure Water Cleaning Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

Future sample return missions will require strict protocols and procedures for reducing inorganic and organic contamination in isolation containment systems. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs [1, 2]. As part of this in-depth organic study, the current curatorial technical support procedure (TSP) 23 was used for cleaning the gloveboxes with ultra pure water (UPW) [3-5]. Particle counts and identification were obtained that could be used as a benchmark for future mission designs that require glovebox decontamination. The UPW baseline study demonstrates that TSP 23 works well for gloveboxes that have been thoroughly degreased. However, TSP 23 could be augmented to provide even better glovebox decontamination. JSC 03243 could be used as a starting point for further investigating optimal cleaning techniques and procedures. DuPont Vertrel XF or other chemical substitutes to replace Freon- 113, mechanical scrubbing, and newer technology could be used to enhance glovebox cleanliness in addition to high purity UPW final rinsing. Future sample return missions will significantly benefit from further cleaning studies to reduce inorganic and organic contamination.

Calaway, Michael J.↗

The Kinematics of Treadmill Locomotion in Space

Locomotion on a treadmill in 0 G will probably remain a centerpiece of NASA's exercise countermeasures programme. This form of physical activity has the potential to cause large bone and muscle forces as well as loading during a period of continuous treadmill exercise. A critical concern is the provision of a treadmill which can approximate 1 G performance in space. At this point, no adequate objective measurements of in-flight treadmill kinetics or of the human response to this activity have been made. Interpretation of the results obtained in the present study is limited by the following: (1) bungee tensions were not measured; (2) ground reaction forces were not measured in parallel with the kinematic measurements; and (3) the instrumentation used to film the astronauts could itself have been affected by microgravity. Despite these shortcomings, what is apparent is that exercise during NASA missions STS 7 and STS 8 resulted in leg motions that were similar to those found during 1 G locomotion on an inclined passive treadmill and on an active treadmill at an even steeper grade. In addition, it was apparent that the majority of the loads were transmitted through the forefoot, and one can surmise that this style of running would result in physiologically significant tensions in the calf musculature and resultant ankle compressive loading. Further speculation regarding limb loading is complicated by the fact that varying amounts of force are transmitted through (1) the treadmill handle and (2) bungee cords that act as a tether. New generations of treadmills are being manufactured that could provide I important information for planners of long-duration space missions. If these types of treadmill are flown on future missions, it will be possible to control bungee tensions more precisely, control for grade and speed, and, most importantly, provide data on the rates and magnitudes of limb loading. These data could then be incorporated into biomechanical models of the lower limb to more fully understand mechanisms of load transmission from distal to proximal structures and to optimize in-flight exercise protocols in such a way that muscle and bone loss could be reduced.

Thornton, W. E.↗

Evalution of a DE-Identification Process for Ocular Imaging

Medical privacy of NASA astronauts requires an organized and comprehensive approach when data are being made available outside NASA systems. A combination of factors, including the uniquely small patient population, the extensive medical testing done on these individuals, and the relative cultural popularity of the astronauts puts them at a far greater risk to potential exposure of personal information than the general public. Therefore, care must be taken to ensure that the astronauts' identities are concealed. Magnetic Resonance Imaging (MRI) medical data is a recent source of interest to researchers concerned with the development of Visual Impairment due to Intracranial Pressure (VIIP) in the astronaut population. Each vision MRI scan of an astronaut includes 176 separate sagittal images that are saved as an "image series" for clinical use. In addition to the medical information these image sets provide, they also inherently contain a substantial amount of non-medical personally identifiable information (PII) such as-name, date of birth, and date of exam. We have shown that an image set of this type can be rendered, using free software, to give an accurate representation of the patient's face. This currently restricts NASA from dispensing MRI data to researchers in a deidentified format. Automated software programs, such as the Brain Extraction Tool, are available to researchers who wish to de-identify MRI sagittal brain images by "erasing" identifying characteristics such as the nose and jaw on the image sets. However, this software is not useful to NASA for vision research because it removes the portion of the images around the eye orbits, which is the main area of interest to researchers studying the VIIP syndrome. The Lifetime Surveillance of Astronaut Health program has resolved this issue by developing a protocol to de-identify MRI sagittal brain images using Showcase Premier, a DICOM (Digital Imaging and Communications in Medicine) software package. The software allows manual editing of one image from a patient's image set to be automatically applied to the entire image series. This new approach would allow a new level of access to untapped medical imaging data relating to VIIP that can be utilized by researchers while protecting the privacy of the astronauts. In the next step toward finalizing this technique, NASA clinical radiology consultants will test the images to verify removal of all metadata and PII.

LaPelusa, Michael B.↗

Sea WiFS Postlaunch Technical Report Series: The SeaBOARR-99 Field Campaign - Volume 8

This report documents the scientific activities during the second Sea-viewing Wide Field-of-view Sensor (Sea- WIFS) Bio-Optical Algorithm Round-Robin (SeaBOARR-99) field campaign, which took place from 2 May to 7 June 1999 on board the Royal Research Ship James Clark Ross during the eighth Atlantic Meridional Transect cruise (AMT-8). The ultimate objective of the SeaBOARR activity is to evaluate the effect of different measurement protocols on bio-optical algorithms using data from a variety of field campaigns. The SeaBOARR-99 field campaign was concerned with collecting a high quality data set of simultaneous in-water and above-water radiometric measurements. The deployment goals documented in this report were to: a) use four different surface glint correction methods to compute water-leaving radiances, Lw(lambda), from above-water data; b) use two different in-water profiling systems and three different methods to compute Lw(lambda) from in-water data; c) use instruments with a common calibration history to minimize intercalibration uncertainties; d) monitor the calibration stability of the instruments in the field with the original SeaWiFS Quality Monitor (SQM) and a commercial, second-generation device called the SQM-II, thereby allowing a distinction between differences in methods from changes in instrument performance; and e) compare the Lw(lambda) values estimated from the above- water and in- water measurements. In addition to describing the instruments deployed and the data collected, a preliminary analysis of part of the SeaBOARR-99 data set is presented (using only the data collected during clear sky, calm sea, and Case-I waters).

Hooker, Stanford B.↗

Situational Awareness from a Low-Cost Camera System

A method gathers scene information from a low-cost camera system. Existing surveillance systems using sufficient cameras for continuous coverage of a large field necessarily generate enormous amounts of raw data. Digitizing and channeling that data to a central computer and processing it in real time is difficult when using low-cost, commercially available components. A newly developed system is located on a combined power and data wire to form a string-of-lights camera system. Each camera is accessible through this network interface using standard TCP/IP networking protocols. The cameras more closely resemble cell-phone cameras than traditional security camera systems. Processing capabilities are built directly onto the camera backplane, which helps maintain a low cost. The low power requirements of each camera allow the creation of a single imaging system comprising over 100 cameras. Each camera has built-in processing capabilities to detect events and cooperatively share this information with neighboring cameras. The location of the event is reported to the host computer in Cartesian coordinates computed from data correlation across multiple cameras. In this way, events in the field of view can present low-bandwidth information to the host rather than high-bandwidth bitmap data constantly being generated by the cameras. This approach offers greater flexibility than conventional systems, without compromising performance through using many small, low-cost cameras with overlapping fields of view. This means significant increased viewing without ignoring surveillance areas, which can occur when pan, tilt, and zoom cameras look away. Additionally, due to the sharing of a single cable for power and data, the installation costs are lower. The technology is targeted toward 3D scene extraction and automatic target tracking for military and commercial applications. Security systems and environmental/ vehicular monitoring systems are also potential applications.

Freudinger, Lawrence C.↗

Share Data with OPeNDAP Hyrax: New Features and Improvements

During the upcoming Summer 2016 meeting of the ESIP Federation (July 19-22), OpenDAP will hold a Developers and Users Workshop. While a broad set of topics will be covered, a key focus is capitalizing on recent EOSDIS-sponsored advances in Hyrax, OPeNDAPs own software for server-side realization of the DAP2 and DAP4 protocols. These Hyrax advances are as important to data users as to data providers, and the workshop will include hands-on experiences of value to both. Specifically, a balanced set of presentations and hands-on tutorials will address advances in 1. server installation, 2. server configuration, 3. Hyrax aggregation capabilities, 4. support for data-access from clients that are HTTP-based, JSON-based or OGC-compliant (especially WCS and WMS), 5. support for DAP4,6.use and extension of server-side computational capabilities, and7.several performance-affecting matters. Topics 2 through 7 will be relevant to data consumers, data providers and notably, due to the open-source nature of all OPeNDAP software to developers wishing to extend Hyrax, to build compatible clients and servers, and/or to employ Hyrax as middleware that enables interoperability across a variety of end-user and source-data contexts. A session for contributed talks will elaborate the topics listed above and embrace additional ones.

OPeNDAP↗

Exploring New Frontiers in Space Communications: Enhancing Delay Tolerant Networking through Cloud and Containerization

The High-rate Delay Tolerant Networking (HDTN) project at NASA Glenn Research Center has developed software that enables more flexible, reliable, and efficient space internetworking by using modern computing techniques such as cloud services, microservices, network function virtualization, software defined networking, and a distributed architecture. HDTN is built upon the Bundle Protocol and related convergence layers which have been developed to mitigate the challenges of the space networking environment including long delays, asymmetric data rates, and intermittent connectivity. The HDTN implementation employs asynchronous message processing tasks which allow for non-blocking operations as well as deployment in both centralized and distributed architectures. This paper investigates deploying HDTN in a containerized approach on the NASA Goddard’s Mission Cloud Platform using Amazon Web Services Elastic Compute Cloud (EC2). Commercial cloud computing will lower operating costs, provide flexible resource allocation, and allow for interconnectivity between multiple NASA centers as well as external partners. Containerization using Docker will enable greater portability and scalability for HDTN to be deployed into a variety of environments. We discuss possible NASA missions and use-cases such as the Laser Communications Relay Demonstration (LCRD) where the services provided by HDTN (reliable transport, high-rate message processing, and store-and-forward capabilities) will be enhanced through cloud computing and containerization. In addition, we describe the HDTN architecture and possible microservice-based networking approaches that can be obtained via HDTN’s configuration capabilities. Finally, we detail the EC2 specifications needed to achieve data rates greater than 1 Gbps to support optical communication missions such as LCRD.

Blake LaFuente↗

Ground Operations of the ISS GNC Babb-Mueller Atmospheric Density Model

The ISS GNC system was updated recently with a new software release that provides onboard state determination capability. Prior to this release, only the Russian segment maintained and propagated the onboard state, which was periodically updated through Russian ground tracking. The new software gives the US segment the capability for maintaining the onboard state, and includes new GPS and state vector propagation capabilities. Part of this software package is an atmospheric density model based on the Babb-Mueller algorithm. Babb-Mueller efficiently mimics a full analytical density model, such as the Jacchia model. While lacchia is very robust and is used in the Mission Control Center, it is too computationally intensive for use onboard. Thus, Babb-Mueller was chosen as an alternative. The onboard model depends on a set of calibration coefficients that produce a curve fit to the lacchia model. The ISS GNC system only maintains one set of coefficients onboard, so a new set must be uplinked by controllers when the atmospheric conditions change. The onboard density model provides a real-time density value, which is used to calculate the drag experienced by the ISS. This drag value is then incorporated into the onboard propagation of the state vector. The propagation of the state vector, and therefore operation of the BabbMueller algorithm, will be most critical when GPS updates and secondary state vector sources fail. When GPS is active, the onboard state vector will be updated every ten seconds, so the propagation error is irrelevant. When GPS is inactive, the state vector must be updated at least every 24 hours, based on current protocol. Therefore, the Babb-Mueller coefficients must be accurate enough to fulfill the state vector accuracy requirements for at least one day. A ground operations concept was needed in order to manage both the on board Babb-Mueller density model and the onboard state quality. The Babb-Mueller coefficients can be determined operationally in two ways. The first method is to calibrate the coefficients in real-time, where a set of custom coefficients is generated for the real-time atmospheric conditions. The second approach is to generate pre-canned sets of coefficients that encompass the expected atmospheric conditions over the lifetime of the vehicle. These predetermined sets are known as occurrences. Even though a particular occurrence will not match the true atmospheric conditions, the error will be constrained by limiting the breadth of each occurrence. Both methods were investigated and the advantages and disadvantages of each were considered. The choice between these implementations was a trade-off between the additional accuracy of the real-time calibration and the simpler development for the approach using occurrences. The operations concept for the frequency of updates was also explored, and depends on the deviation in solar flux that still achieves the necessary accuracy of the coefficients. This was determined based on historical solar flux trends. This analysis resulted in an accurate and reliable implementation of the Babb-Mueller coefficients and how flight controllers use them during realtime operations.

Brogan, Jonathan↗

Detecting Organic Compounds Released from Iron Oxidizing Bacteria using Sample Analysis at Mars (SAM) Like Instrument Protocols

Mars is a planet of great interest for Astrobiology since its past environmental conditions are thought to have been favourable for the emergence life. At present, the Red Planet is extremely cold and dry and the surface is exposed to intense UV and ionizing radiation, conditions generally considered to be incompatible with life as we know it on Earth. It was proposed that the shallow subsurface of Mars, where temperatures can be above freezing and liquid water can exist on rock surfaces, could harbor chemolithoautotrophic bacteria such as the iron oxidizing microorganism Pseudomonas sp. HerB. The Mars Science Laboratory (MSL) mission will provide the next opportunity to carry out in situ measurements for organic compounds of possible biological origin on Mars. One instrument onboard MSL, called the Sample Analysis at Mars (SAM) instrument suite, will carry out a broad and sensitive search for organic compounds in surface samples using either high temperature pyrolysis or chemical extraction followed by gas chromatography mass spectrometry. We present gas chromatograph mass spectrometer (GC/MS) data on crushed olivine rock powders that have been inoculated with Pseudomonas sp. HerB at different concentrations ranging from approx 10(exp 2) to 10(exp 7) cells per gram. The inoculated olivine samples were heated under helium carrier gas flow at 500 C and the pyrolysis products concentrated using a SAM-like hydrocarbon trap set at -20 C followed by trap heating and analysis by GC/Ms. In addition, the samples were also extracted using a low temperature "one-pot" chemical extraction technique using N-methyl, N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) as the silylating agent prior to GC/MS analysis. We identified several aldehydes, thiols, and alkene nitriles after pyrolysis GC/MS analysis of the bacteria that were not found in the olivine control samples that had not been inoculated with bacteria. The distribution of pyrolysis products extracted from the bacteria was clearly distinct from similar GC/MS analyses of the carbonaceous meteorite Murchison that was dominated by sulfur containing aromatic compounds. A similar comparison, if organic compounds are detected by SAM on Mars, could be useful to help discriminate between meteoritic or biological origins.

Glavin, D. P.↗