LP-search and its use in analysis of the accuracy of control systems with acoustical models

The LP-search is proposed as an analog of the Monte Carlo method for finding values in nonlinear statistical systems. It is concluded that: To attain the required accuracy in solution to the problem of control for a statistical system in the LP-search, a considerably smaller number of tests is required than in the Monte Carlo method. The LP-search allows the possibility of multiple repetitions of tests under identical conditions and observability of the output variables of the system.

Sergeyev, V. I.↗

Accuracy analysis of the ephemerides of the Galilean satellites

Known discrepancies between Sampson's Theory and observations of the Galilean satellites produce in plane errors of about 1200 km. Since the mean longitude is responsible for most of the discrepancy a simple time correction may be used to significantly reduce these errors. An analysis of the time corrections derived for Sampson's Theory, concludes that the dominant error in the mean longitudes results from Sampson's definition of time, which was determined by the observations which he used in constructing the theory. Imposition of the libration constraint results in changes to the time corrections which are less than the standard deviation of those quantities. The individual eclipse observational errors are shown to be proportional to the square root of the period. With improved star catalogs, the attainable accuracy of the ephemerides of the Galilean satellites is about 100 km from photographic plates versus about 200 km for eclipse observations.-

Peters, C. F.↗

On the accuracy of Whitham's method

The steady flow of an ideal gas past a conical body is studied by the method of matched asymptotic expansions and by Whitham's method in order to assess the accuracy of the latter. It is found that while Whitham's method does not yield a correct asymptotic representation of the perturbation field to second order in regions where the flow ahead of the Mach cone of the apex is disturbed, it does correctly predict the changes of the second-order perturbation quantities across a shock (the first-order shock strength). The results of the analysis are illustrated by a special case of a flat, rectangular plate at incidence.

Zahalak, G. I.↗

The modified equation approach to the stability and accuracy analysis of finite-difference methods

The stability and accuracy of finite-difference approximations to simple linear partial differential equations are analyzed by studying the modified partial differential equation. Aside from round-off error, the modified equation represents the actual partial differential equation solved when a numerical solution is computed using a finite-difference equation. The modified equation is derived by first expanding each term of a difference scheme in a Taylor series and then eliminating time derivatives higher than first order by certain algebraic manipulations. The connection between 'heuristic' stability theory based on the modified equation approach and the von Neumann (Fourier) method is established. In addition to the determination of necessary and sufficient conditions for computational stability, a truncated version of the modified equation can be used to gain insight into the nature of both dissipative and dispersive errors.

Warming, R. F.↗

NASA hydrogen maser accuracy and stability in relation to world standards

Frequency comparisons were made among five NASA hydrogen masers to a precision of one part in 10 to the 13th power. Frequency comparisons were also made between these masers and the cesium-beam ensembles of several international standards laboratories. The hydrogen maser frequency stabilities as related to the international time scale (IAT) were comparable to the frequency stabilities of individual time scales with respect to IAT. The relative frequency variations among the NASA masers were 2 plus or minus 2 parts in 10 to the 13th power after a three year interval. Charts are developed to show the results of the accuracy tests.

Peters, H. E.↗

The problem of selecting an optimum frequency for a measuring generator in determining the value of the hydrophysical parameter with a given accuracy

The selection of the optimum frequency for a measuring generator for determining the value of the hydrophysical parameter with a given degree of accuracy is discussed. Methods from information theory for measuring generators are described. Conversion of the frequency of generators into digital form by means of statistical averaging is also described.

Stepanyuk, V. A.↗

The influence of inhomogeneity of the reflectivity distribution on the accuracy of its measurement

The influence of pulse volume dimensions on the accuracy of reflectivity from various clouds is considered. It is shown that due to the spatial averaging and the inhomogeneities of the clouds, the dependence frequently breaks down, which is a cause of lower values of the spatial distribution estimate. Values of the corrections calculated for various conditions are presented.

Salman, Y. M.↗

Application of very long baseline interferometry to Astrometry and Geodesy: effects of frequency standard instability on accuracy

The accuracy of geodetic and astrometric information obtained from very long baseline interferometry (VLBI) observations is dependent upon the stability of the frequency standard, or clock, used at each site of VLBI array. The sensitivities of two hydrogen maser frequency standards of different design to pressure, temperature, and magnetic field variations were measured; and, for one of the standards, sensitivity was found to be severe enough to degrade the information content of VLBI measurements. However, the effect on the geometric and astrometric information of such clock instabilities, with time scales of hours or greater, can be sharply reduced through the use of differencing techniques.

Clark, T. A.↗

SL-4 S-190 spectroradiometric accuracy

A procedure used for determining radiometric accuracy, consisting of two phases is presented. In the first phase a sensitometer was used as a calibrated radiometric target; while in the second, the moon was employed. Since the moon is a nonhomogeneous target whose radiometric signature is not as well-known as the irradiants of the sensitometer, the majority of this effort was directed towards the reduction and analysis of the sensitometric data.

Albrizio, R. A.↗

Position accuracy of aircraft area navigation systems and the effect of system parameters

The steady-state solution to the stochastic differential equation describing the error covariance matrix for a simplified area navigation system has been obtained. The solution shows that nominal error deviations of less than 1.0 nmi are feasible for a DME system. The manner in which estimates are affected by range, air data system accuracy, measurement time interval, and gust deviations, and their impacts on the area navigation system are discussed.

Foudriat, E. C.↗

Diagnostic accuracy of an ultrasonic multiple transducer cardiac imaging system

An ultrasonic multiple-transducer imaging system for intracardiac structure visualization is developed in order to simplify visualization of the human heart in vivo without radiation hazard or invasion of the body. Results of the evaluation of the diagnostic accuracy of the devised system in a clinical setting for adult patients are presented and discussed. Criteria are presented for recognition of mitral valva prolapse, mitral stenosis, pericardial effusion, atrial septal defect, and left ventricular dyssynergy. The probable cause for false-positive and false-negative diagnoses is discussed. However, hypertrophic myopathy and congestive myopathy were unable to be detected. Since only qualitative criteria were used, it was not possible to differentiate patients with left ventricular volume overload from patients without cardiac pathology.

Popp, R. L.↗

The Annular Suspension and Pointing (ASP) system for space experiments and predicted pointing accuracies

An annular suspension and pointing system consisting of pointing assemblies for coarse and vernier pointing is described. The first assembly is attached to a carrier spacecraft (e.g., the space shuttle) and consists of an azimuth gimbal and an elevation gimbal which provide 'coarse' pointing. The second or vernier pointing assembly is made up of magnetic actuators of suspension and fine pointing, roll motor segments, and an instrument or experiment mounting plate around which is attached a continuous annular rim similar to that used in the annular momentum control device. The rim provides appropriate magnetic circuits for the actuators and the roll motor segments for any instrument roll position. The results of a study to determine the pointing accuracy of the system in the presence of crew motion disturbances are presented. Typical 3 sigma worst-case errors are found to be of the order of 0.001 arc-second.

Anderson, W. W.↗

The effects of atmospheric refraction on the accuracy of laser ranging systems

Correction formulas derived by Saastamoinen and Marini, and the ray traces through the refractivity profiles all assume a spherically symmetric refractivity profile. The errors introduced by this assumption were investigated by ray tracing through three-dimensional profiles. The results of this investigation indicate that the difference between ray traces through the spherically symmetric and three-dimensional profiles is approximately three centimeters at 10 deg and decreases to less than one half of a centimeter at 80 deg. If the accuracy desired in future laser ranging systems is less than a few centimeters, Saastamoinen and Marini's formulas must be altered to account for the fact that the refractivity profile is not spherically symmetric.

Zanter, D. L.↗

Goddard laser systems and their accuracies

The latest Goddard laser systems, and their use in the Earth Dynamic Program are described. The tracking accuracies obtained using actual field data are discussed.

Vonbun, F. O.↗

On the accuracy of the 'decoupled l-dominant' approximation for atom-molecule scattering

Cross sections for rotational excitation and spectral pressure broadening of HD, HCl, CO, and HCN due to collisions with low energy He atoms have been computed within the 'decoupled l-dominant' (DLD) approximation and are compared with accurate close coupling results and also with two similar approximations, the effective potential of Rabitz and the coupled states of McGuire and Kouri. DLD predictions of state-to-state cross sections are rather good, being only slightly less accurate than coupled states results. DLD is far superior to either the coupled states or effective potential methods for pressure broadening calculations, although it may not be uniformly of the quantitative accuracy desirable for obtaining intermolecular potentials from experimental data.

Green, S.↗

Improved accuracy with phase-change paints

Technique, using effective thermophysical property, significantly improves accuracy when phase-change coating methods are used to determine heat transfer rate over surface of small complex models.

Drummond, J. D.↗

Classification accuracy improvement

Improvements made in processing system designed for MIDAS (prototype multivariate interactive digital analysis system) effects higher accuracy in classification of pixels, resulting in significantly-reduced processing time. Improved system realizes cost reduction factor of 20 or more.

Kistler, R.↗

Parametric study of predictor accuracy impact on OFT rendezvous targeting

A parametric study was made to quantitatively define the effects of errors in the state vector predictor used by the Operational Flight Trainer (OFT) rendezvous targeting algorithms. The effect of the predictor accuracy on the OFT rendezvous profile is shown by the sensitivity of various critical rendezvous parameters with respect to downrange and radial predictor error rates. The effect of both inertial (same errors on both vehicles) and relative (differential errors on one vehicle with respect to the other) errors were considered. Relative radial error rates had the largest impact on the rendezvous followed by relative downrange errors, radial inertial errors and downrange inertial errors.