Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A hybrid neural architecture: Online attosecond x-ray characterization

The emergence of high-repetition-rate x-ray free-electron lasers (XFELs), such as SLAC’s LCLS-II, serves as our canonical example for autonomous controls that necessitate high-throughput diagnostics paired with streaming computational pipelines capable of single-shot analysis with extremely low latency. We present the deterministic characterization with an integrated parallelizable hybrid resolver architecture, a hybrid machine learning framework designed for fast, accurate analysis of XFEL diagnostics using angular streaking-based sinogram images. This architecture integrates convolutional neural networks and bidirectional long short-term memory models to denoise input, identify x-ray sub-spike features, and extract sub-spike relative delays with sub-30 attosecond temporal resolution. Deployed on low-latency hardware, it achieves over 10 kHz throughput with 168.3 μs inference latency, indicating scalability to 14 kHz with field-programmable gate array integration. By transforming regression tasks into classification problems and leveraging optimized error encoding, we achieve high precision with low-latency performance that is critical for real-time streaming event selection and experimental control feedback signals. This represents a key development in real-time control pipelines for next-generation autonomous science, generally, and high repetition-rate x-ray experiments in particular.

Accelerator Physics (physics.acc-ph)↗

NSLS-II longitudinal impedance budget

From the beginning of the NSLS-II project, the vacuum chamber of the NSLS-II storage ring has been optimized to reduce its impedance. The optimization, performed in close collaboration with the Diagnostic, Vacuum, RF, and Mechanical Engineering groups, has been achieved via calculating the impedance of the vacuum chamber components with the use of both analytical and numerical tools, with the numerical computations carried out with the GdfidL code. Fore reliable NSLS-II operation with the total beam current of 500 mA, each component of the vacuum chamber has been individually optimized to minimize the beam-induced heating and to prevent single-bunch and coupled-bunch instabilities. In this study, the impedance calculation and optimization know-how are summarized for all the chamber components, and the total longitudinal impedance budget is analyzed. As a result of this extensive research and engineering effort, the design beam current of 500 mA has been recently accumulated in NSLS-II without any major problem caused by collective effects.

43 PARTICLE ACCELERATORS↗

Validation of edge turbulence codes against the TCV-X21 diverted L-mode reference case

Self-consistent full-size turbulent-transport simulations of the divertor and scrape-off-layer (SOL) of existing tokamaks have recently become feasible. This enables the direct comparison of turbulence simulations against experimental measurements. In this work, we perform a series of diverted ohmic L-mode discharges on the tokamak à configuration variable (TCV) tokamak, building a first-of-a-kind dataset for the validation of edge turbulence models. This dataset, referred to as TCV-X21, contains measurements from five diagnostic systems from the outboard midplane (OMP) to the divertor targets—giving a total of 45 one- and two-dimensional comparison observables in two toroidal magnetic field directions. The experimental dataset is used to validate three flux-driven 3D fluid-turbulence models—GBS, GRILLIX and TOKAM3X. With each model, we perform simulations of the TCV-X21 scenario, individually tuning the particle and power source rates to achieve a reasonable match of the upstream separatrix value of density and electron temperature. We find that the simulations match the experimental profiles for most observables at the OMP—both in terms of profile shape and absolute magnitude—while a comparatively poorer agreement is found towards the divertor targets. The match between simulation and experiment is seen to be sensitive to the value of the resistivity, the heat conductivities, the power injection rate and the choice of sheath boundary conditions. Additionally, despite targeting a sheath-limited regime, the discrepancy between simulations and experiment also suggests that the neutral dynamics should be included. The results of this validation show that turbulence models are able to perform simulations of existing devices and achieve reasonable agreement with experimental measurements. Where disagreement is found, the validation helps to identify how the models can be improved. By publicly releasing the experimental dataset and validation analysis, this work should help to guide and accelerate the development of predictive turbulence simulations of the edge and SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tomography of longitudinal phase space linearization for the generation of attosecond electron bunches

The generation of electron bunches on the attosecond timescale is important for a multitude of accelerator-based applications. Here, we report on a tomographic measurement of the (pre)linearized longitudinal phase space of a low charge 3 MeV electron bunch generated with the 1.6 cell Pegasus photoinjector for the generation of attosecond bunches. The nonlinear correlations in the longitudinal phase space induced by space charge at the photocathode, radiofrequency field curvature of the gun, and vacuum dispersion are compensated using a compact X-band linearizer. Then, the initial and compensated phase of the picosecond electron bunch is precisely reconstructed by neural network assisted tomographic reconstruction from momentum spectra at varying buncher linac phase. Finally, we combine the measured phase space shape with particle tracking simulations to show that electron bunches as short as 941 as develop downstream the beamline.

Beam control↗

Niowave Ancillary Systems – FY21: In Partial Fulfillment of the Deliverable Requirement for Niowave Ancillary Systems Support by LANL

Niowave Inc. produces medical radioisotopes within the US. Lead-bismuth eutectic (LBE) is irradiated using an electron beam to produce neutrons that are used in the production of Molybdenum-99 (Mo-99). The medical community relies on a steady supply of Mo-99 which is primarily used in medical diagnostic imaging. The irradiation of LBE results in high temperatures within the molten metal, this work focusses on the design of ancillary systems associated with the liquid metal system. The LBE is initially at a temperature of 200°C and flows over a steel plate to create a waterfall. The electron beam is then aimed at the waterfall to generate neutrons. The peak temperatures of the LBE post irradiation depend on the beam energy of the LINAC. For a 15 MeV and 20 kW beam, the temperatures can range between 300°C and 350°C. The LBE is cycled through the system to create a closed loop that requires the post-irradiation LBE to be cooled back to 200°C. This work focuses on the heat exchanger and condenser system responsible for the cooling of the post-irradiation LBE.

36 MATERIALS SCIENCE↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Strong ultrafast nonlinear optical response from megaelectronvolt electrons in semiconductors

Understanding radiation–matter interactions on ultrafast timescales is essential for radiation detection technologies, particularly those requiring precise timing, such as plasma monitoring, synchrotron diagnostics and medical imaging. However, the detection of highly ionizing radiation is challenging due to the stochastic nature of the interactions, resulting in dispersed energy deposition. Here we show a nonlinear optical response in semiconductors induced by 150-fs, 4.2-MeV electrons that generate highly localized charge carriers. The induced sub-10-ps optical modulation reached up to 24.5%, accompanied by a blueshift in the absorption edge consistent with band filling and carrier densities of 10 18 cm −3 . These carrier densities are 100-fold higher than expected from the deposited energy, indicating the extreme spatial localization of carriers at inelastic collisions along the ionization trajectories, thereby leading to the observed modulation. The strong nonlinearity of the MeV-electron-induced optical response enables the precise spatiotemporal detection of ionizing radiation at room temperature using common semiconductors and laser systems.

Jeong, D. [Stanford Univ., CA (United States)] (OR↗

Development Of Non-Invasive Beam Diagnostics By Quantum Optics-Based Detection

We report our effort and latest progress developing diagnostics using quantum optics-based detection method for determining the spatial properties and current of electron beams. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturb the atomic spin’s quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size and total current. We tested this method for an e-beam with currents ranging from 30 to 110 µA. Our study shows this approach is insensitive to electron kinetic energy, and is initially verified experimentally between 10 to 20 keV. A different approach was also performed with highly excited rubidium atoms in Rydberg states through a coherent two photon process. We use this detection scheme to measure the electric field generated by a

Zhang, S. [Thomas Jefferson National Accelerator F↗

Summary of the CeC Experiment in RHIC Run 21

The coherent electron cooling (CeC) experiment at RHIC is crucial for determining the feasibility of this technique for cooling the hadron beam in the electron-ion collider (EIC) and reaching the luminosity of 10 34 cm -1 s -1 . During RHIC Run 21, various progresses have been made including successfully commissioning the time resolved diagnostic beam line (TRDBL), achieving the key performance parameters (KPP) of the system and the development of novel methods for accurate alignment of the electron beam with the ion beam. While the longitudinal cooling of the ion beam with cooling time of 100 hours was observed during Run 21, it was related to the traditional electron cooling since the cooling rate was not as sensitive to the energy of the electron beam as what one would expect from the CeC. In Run 21, we were not able to observe the longitudinal cooling of the ion beam caused by CeC and the main challenges are identified as the insufficient stability of the electrons' energy. The sources of the energy jitter have been identified and we are making improvements to the stability of the CeC system for Run 22.

43 PARTICLE ACCELERATORS↗

Single shot cathode transverse momentum imaging in high brightness photoinjectors

In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emittance per rms laser spot size, is proposed for photocathode rf guns. By tuning the gun solenoid focusing, the electrons’ transverse momenta at the cathode are imaged to a downstream screen, which enables a single shot measurement of both the rms value and the detailed spectra of the photoelectrons’ transverse momenta. Both simulations and proof of principle experiments are reported.

43 PARTICLE ACCELERATORS↗

Ion emission from warm dense matter produced by irradiation with a soft x-ray free-electron laser

Here we report on an experiment performed at the FLASH2 free-electron laser (FEL) aimed at producing warm dense matter via soft x-ray isochoric heating. In the experiment, we focus on study of the ions emitted during the soft x-ray ablation process using time-of-flight electron multipliers and a shifted Maxwell–Boltzmann velocity distribution model. We find that most emitted ions are thermal, but that some impurities chemisorbed on the target surface, such as protons, are accelerated by the electrostatic field created in the plasma by escaped electrons. The morphology of the complex crater structure indicates the presence of several ion groups with varying temperatures. We find that the ion sound velocity is controlled by the ion temperature and show how the ion yield depends on the FEL radiation attenuation length in different materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

Quadruple Langmuir probe characterization of different fuel gases in a plasma deflagration accelerator

Astrophysical flows may be studied by reproducing similar conditions using a coaxial plasma accelerator operating in the deflagration regime (or plasma deflagration accelerator). This allows for the recreation and investigation of dynamics present in complex highly coupled plasma systems at the laboratory scale. Here we report on measurements of the plasma density, temperature, plasma potential and velocity found using a quadruple Langmuir probe (QLP) on such a deflagration accelerator in the form of the Stanford Coaxial High ENerGy (CHENG) device operating with multiple gases – specifically argon, nitrogen and hydrogen. Experiments show a general decrease in bulk plasma velocity with gas atomic mass from upwards of 120 km s –1 with hydrogen to less than 30 km s –1 with argon. There was an accompanying increase in peak plasma density with increasing atomic mass from ~3 × 10 20 m –3 with hydrogen to ~1.5 × 10 21 m –3 with argon. It was found that the momentum flux and internal energy density also generally increase with atomic mass while the particle flux is constant between shots. Further investigation is needed to understand these correlations and the underlying physics. Lastly, comparisons with scaling laws show that while the CHENG device may be operated in such a way as to simulate the effects of bulk solar wind movement, it may not properly capture the thermal effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time plasma monitoring framework for advanced plasma control and ML-research in DIII-D

Real-time and adaptive plasma control is crucial for robust tokamak operation, requiring sensitivity and tolerance measurements of the plasma state. This paper presents the implementation of an integrated real-time plasma monitoring framework on the DIII-D tokamak to support advanced control approaches, including machine-learning (ML) methods. The system is built on the SHIELD framework, a high-performance modular architecture that provides a unified pipeline for integrating diverse diagnostics. The framework leverages high-bandwidth digitizers, fast numerical processing, and deterministic, low-latency interconnects to stream high-fidelity data from diagnostics such as electron cyclotron emission (ECE), beam emission spectroscopy (BES), CO interferometers, and a visible tangential divertor camera (TangTV). The system’s validity is demonstrated through direct comparisons of real-time and offline data. Furthermore, we present two key applications of the developed plasma monitoring system with ML-based plasma control strategies, including real-time divertor detachment and active Alfvén Eigenmode control. As a result, this work presents a robust and scalable approach for integrating high-frequency, multidimensional diagnostics into advanced control algorithms for future fusion devices.

AI/ML↗

Inverse model based error detection in beamline optics

Optics tuning in transfer lines and LINACs can be challenging due to the fact that multiple combinations of machine settings can lead to the same diagnostic output. Moreover, the lack of a periodic solution can limit the ability to infer optics in the same way as rings from BPM signals. Model based approaches are often used to assist with the optics tuning in combination with optimization or parameter estimation. Here we have developed a novel approach using machine learning inverse models trained on a known configuration to detect variations in quadrupole settings without explicitly including them in the model. This paper shows a comparison of neural network models and linear models on both a simulation based study and experimental studies conducted at the AGS to RHIC transfer line at Brookhaven National Lab.

43 PARTICLE ACCELERATORS↗

Global Issues of Radiopharmaceutical Access and Availability: a Nuclear Medicine Global Initiative Project

The Nuclear Medicine Global Initiative (NMGI) was formed in 2012 by 13 international organizations to promote human health by advancing the field of nuclear medicine and molecular imaging by supporting the practice and application of nuclear medicine. The first project focused on standardization of administered activities in pediatric nuclear medicine and resulted in two manuscripts. For its second project the NMGI chose to explore issues impacting on access and availability of radiopharmaceuticals around the world. Methods: Information was obtained by survey responses from 35 countries on available radioisotopes, radiopharmaceuticals and kits for diagnostic and therapeutic use. Issues impacting on access and availability of radiopharmaceuticals in individual countries were also identified. Results: Detailed information on radiopharmaceuticals utilized in each country, and sources of supply, was evaluated. Responses highlighted problems in access particularly due to the reliance on a sole provider, regulatory issues and reimbursement, as well as issues of facilities and workforce particularly in low- and middle-income countries. Conclusion: Finally, strategies to address access and availability of radiopharmaceuticals are outlined, to enable timely and equitable patient access to nuclear medicine procedures worldwide. In the face of disruptions to global supply chains by the COVID-19 outbreak, renewed focus on ensuring reliable supply of radiopharmaceuticals is a major priority for nuclear medicine practice globally.

43 PARTICLE ACCELERATORS↗