Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “YAg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Third-generation FAGE instrument for tropospheric hydroxyl radical measurement

A single-stage, frequency-doubled, copper vapor laser-pumped dye laser has been constructed to be used in the measurement of atmospheric hydroxyl radical concentrations. A new photon counting instrument is used for HO fluorescence detection. Theoretical and experimental studies of instrument performance show better sensitivities and reduced photolytic interferences than have been possible with previous systems based upon Nd:YAG pumping.

Chan, C. Y.↗

High pressure-temperature electrical conductivity of magnesiowustite as a function of iron oxide concentration

The electrical conductivity of (Mg, Fe)O magnesiowustite containing 9 and 27.5 mol pct FeO has been measured at simultaneously high pressures (30-32 GPa) and temperatures using a diamond anvil cell heated with a continuous wave Nd:YAG laser and an external resistance heater. The conductivity depends strongly on the FeO concentration at both ambient and high pressures. At the pressures and temperatures of about 30 GPa and 2000 K, conditions expected in the lower mantle, the magnesiowustite containing 27.5 percent FeO is 3 orders of magnitude more conductive than that containing 9 percent FeO. The activation energy of magnesiowustite decreases with increasing iron concentration from 0.38 (+ or - 0.09) eV at 9 percent FeO to 0.29 (+ or - 0.05) eV at 27.5 percent FeO.

Li, Xiaoyuan↗

Simplifications of the RELIEF flow tagging system for laboratory use

The use of an O2:He stimulated Raman cell to generate the Stokes beam for the Raman vibrational pumping step of the RELIEF (Raman Excitation plus Laser-Induced Electronic Fluorescence) flow tagging method is reported. Use of the Raman cell rather than a dye laser provides pump and Stokes beams which are automatically frequency matched and temporally and spatially overlapped. The Nd:YAG pump laser is operated multilongitudinal mode, which eliminates the need for injection seeding, resulting in decreased operation complexity and improved stability with respect to acoustic noise. Results are presented for 1st Stokes conversion efficiency and stimulated Brillouin backscattering loss and are compared to the case of pure O2. Scanning CARS measurements of the Q-branch lineshape for both pure O2 and the O2:He mixture are also presented.

Lempert, Walter R.↗

The 27-28 October 1986 FIRE IFO cirrus case study - Cloud optical properties determined by High Spectral Resolution Lidar

The High Spectral Resolution Lidar (HSRL) was operated from a roof-top site in Madison, Wisconsin. The transmitter configuration used to acquire the case study data produces about 50 mW of ouput power and achieved eye-safe, direct optical depth, and backscatter cross section measurements with 10 min averaging times. A new continuously pumped, injection seeded, frequency doubled Nd:YAG laser transmitter reduces time-averaging constraints by a factor of about 10, while improving the aerosol-molecular signal separation capabilities and wavelength stability of the instrument. The cirrus cloud backscatter-phase functions have been determined for the October 27-28, 1986 segment of the HSRL FIRE dataset. Features exhibiting backscatter cross sections ranging over four orders of magnitude have been observed within this 33 h period. During this period, cirrus clouds were observed with optical thickness ranging from 0.01 to 1.4. The altitude relationship between cloud top and bottom boundaries and the optical center of the cloud is influenced by the type of formation observed.

Grund, C. J.↗

Single-frequency diode-pumped lasers for free-space optical communication

Recent advances in laser technology for intersatellite optical communication systems are reviewed and illustrated with graphs and diagrams. Topics addressed include (1) single-frequency diode-pumped Nd:YAG lasers of monolithic ring configuration (yielding 368-384 mW output power with 1-W pumping), (2) injection chaining of up to 10 monolithic resonators to achieve redundancy and/or higher output power, (3) 2-kHz-linewidth 5-mW versions of (1) which are tunable over a 30-MHz range for use as local oscillators in coherent communication, (4) resonant external modulation and doubling or resonant phase modulation of diode-pumped lasers, and (5) wavelength multiplexing.

Kane, Thomas J.↗

Narrowband lidar technique for sodium temperature and Doppler wind observations of the upper atmosphere

A new two-frequency lidar for measuring mesospheric Na temperature profiles is described that uses a stabilized CW single-mode dye laser oscillator (rms frequency jitter less than 1 MHz) followed by a pulsed dye power amplifier (140 MHz FWHM linewidth) that is pumped by an injection-locked Nd:YAG laser. The laser oscillator is tuned to the two operating freqencies by observing the Doppler-free structure of the Na D2 fluorescence spectrum in a vapor cell. The lidar technique and initial observations of the temperature profile between 82 and 102 km at Ft. Collins, CO are described. Absolute temperature accuracies at the Na layer peak of better than + or - 3 K with a vertical resolution of 1 km and an integration period of approximately 5 min were achieved in this initial experiment. Finally, a multiple frequency technique for the simultaneous measurement of both temperature and Doppler wind profiles is discussed.

Bills, Richard E.↗

Differential absorption lidar systems for tropospheric and stratospheric ozone measurements

A lidar facility has been established at the Jet Propulsion Laboratory-Table Mountain Facility located at an altitude of 2300 m in the San Gabriel Mountains in Southern California. This facility is using the technique of differential absorption lidar to measure atmospheric ozone concentration profiles. Two separate systems are needed to obtain the profile from the ground up to an altitude of 45 to 50 km. An Nd:YAG-based system is described for measurements from the ground up to 15 to 20 km altitude, and an excimer-laser-based system for measurements from 15 km to 45 to 50 km altitude. The systems were designed to make high-precision, long-term measurements to aid in the detection of changes in the atmospheric ozone abundance through participation in the Network of Detection of Stratospheric Change.

Mcdermid, I. Stuart↗

Lidar In-Space Technology Experiment (LITE) - NASA's first in-space lidar system for atmospheric research

Engineering aspects are presented of the design, fabrication, integration, and operation of the Lidar In-Space Technology Experiment (LITE) for flight aboard the Space Shuttle in mid-1993. The LITE system is being developed by NASA/Langley Research Center and will be used to detect stratospheric and tropospheric aerosols, probe the planetary boundary layer, measure cloud top heights, and measure atmospheric temperature and density in the 10- to 40-km range. The system consists of a nominal telescope receiver 1 meter in diameter, a three-color Nd:YAG laser transmitter, and the system electronics. The system makes extensive use of Space Shuttle resources for electrical power, thermal control, and command and data handling.

Couch, Richard H.↗

Pulsed coherent solid-state 1.06-micron and 2.1-micron laser radar systems for remote velocity measurement

A low average power, pulsed, solid-state, 1.06-micron coherent laser radar (CLR) for range and velocity measurements of atmospheric and hard targets has been developed. The system has been operating at a field test site near Boulder, CO since September, 1988. Measurements have been taken on moving targets such as atmospheric aerosol particles, belt sanders, spinning disks, and various stationary targets. The field measurements have shown that this system exhibits excellent velocity measurement performance. A fast-tuning CW Nd:YAG oscillator has also been developed which has a frequency tuning range of greater than 30 GHz (which spans a target radial velocity range of over 16 km/s) and a tuning speed greater than 30 GHz/ms.

Henderson, Sammy W.↗

Airborne water vapor DIAL system development

A differential absorption lidar (DIAL) system developed at NASA Langley Research Center for the remote measurement of atmospheric H2O and aerosols from an aircraft is briefly discussed. This DIAL system utilizes a Nd:YAG laser-pumped dye laser as the off-line transmitter and a narrowband, tunable Alexandrite laser as the on-line transmitter. A 1-m monochromator and a multipass absorption cell are used to position the on-line laser to the center of the H2O line. The receiver system has a 14-in. diameter, f/7 Celestron telescope to collect the backscattered laser light and focus in into the detector optics. Return signals are converted to electrical signals by the optical detector and are digitalized and stored on magnetic tape. The results of fligh tests of the system are shown.

Higdon, Noah S.↗

Laser-induced stimulated Raman scattering in the forward direction of a droplet - Comparison of Mie theory with geometrical optics

This paper uses Mie theory to treat electromagnetic scattering and to evaluate field enhancement in the forward direction of a small droplet irradiated by a high-energy beam and compares the results of calculations with the field-enhancement evaluation obtained via geometrical optics treatment. Results of this comparison suggest that the field enhancement located at the critical ring region encircling the axis in the forward direction of the droplet can support laser-induced Raman scattering. The results are supported by experimental observations of the interaction of a 120-micron-diam water droplet with a high-energy Nd:YAG laser beam.

Srivastava, Vandana↗

Broadly tunable high-power operation of an all-solid-state titanium-doped sapphire laser system

Broadly tunable and high-power operation of a Ti-doped sapphire laser is obtained with a diode-laser-pumped frequency-doubled Nd:YAG laser as the pump source. A maximum broadband (FWHM = 25 nm) output pulse energy of 720 microJ at 795 nm in a TEM00 mode is obtained for 1850 microJ of energy of 532-nm pump light. A minimum pulse duration of 7 nsec is obtained from a 40-mm-long cavity. With the use of an intracavity prism, the Ti:sapphire laser is tunable continuously over the 696-1000-nm spectral range (with three different mirror sets).

Steele, T. R.↗

Low-threshold, CW, all-solid-state Ti:Al2O3 laser

A CW Ti:Al2O3 ring laser with a threshold power of 119 mW is demonstrated. It provides a tunable source of single-frequency, diffraction-limited radiation that is suitable for injection seeding. The Ti:Al2O3 laser is operated with a diode-laser-pumped, frequency-doubled, Nd:YAG laser as the sole pump source.

Harrison, James↗

Noncontact acousto-ultrasonics using laser generation and laser interferometric detection

A compact, portable fiber-optic heterodyne interferometer designed to detect out-of-plane motion on surfaces is described. The interferometer provides a linear output for displacements over a broad frequency range and can be used for ultrasonic, acoustic emission, and acousto-ultrasonic (AU) testing. The interferometer in conjunction with a compact pulsed Nd:YAG laser represents a noncontact testing system. This system was tested to determine its usefulness for the AU technique. The results obtained show that replacement of conventional piezoelectric transducers (PZT) with a laser generation/detection system make it possible to carry out noncontact AU measurements. The waveforms recorded were 5 MHZ PZT-generated ultrasound propagating through an aluminum block, detection of the acoustic emission event, and laser AU waveforms from graphite-epoxy laminates and a filament-wound composite.

Green, Robert E., Jr.↗

Prototype FAGE determination of NO2

A low pressure laser-excited-fluorescence technique for the direct determination of atmospheric NO2 has been developed. Using a frequency-doubled Nd-YAG pump laser and a signal collection time of 20 s (10 s each signal and background), a detection limit of 450 pptv is calculated under laboratory conditions. Improved sensitivities will be possible with a higher repetition rate laser and lower fluorescence cell pressures.

George, L. A.↗

Coherent lidar airborne windshear sensor - Performance evaluation

As part of the NASA/FAA National Integrated Windshear Program, a measurable windshear hazard index has been defined that can be remotely sensed from an aircraft, to give the pilot information about the wind conditions along the flight path. A technology analysis and end-to-end performance simulation measuring signal-to-noise ratios and resulting wind velocity errors for competing coherent laser radar (lidar) systems have been carried out. The results show that a Ho:YAG lidar at a wavelength of 2.1 microns and a CO2 lidar at 10.6 microns can give the pilot information about the line-of-sight component of a windshear threat from his present position to a region extending 2-4 km in front of the aircraft. This constitutes a warning time of 20-40 s, even in conditions of moderately heavy precipitation.

Targ, Russell↗

Heterodyne Doppler 1-micron lidar measurement of reduced effective telescope aperture due to atmospheric turbulence

A pulsed Nd:YAG bistatic focused-beam lidar allowing simultaneous heterodyne and direct detection of the same lidar returns has been experimentally employed to ascertain the effect of atmospheric turbulence on heterodyne and direct-detection lidar at 1 micron, by measuring the average carrier-to-noise ratio and statistical fluctuation level in the return signals under various experimental and atmospheric conditions. Atmospheric turbulence is found capable of reducing the lidar receiver's effective telescope aperture and heterodyne detection efficiency. This observed effective-aperture limitation functionally resembles predictions based on the Clifford and Wandzura (1981) heterodyne wavefront detection theory.

Chan, Kin Pui↗

Study of cluster formation and its effects on Rayleigh and Raman scattering measurements in a Mach 6 wind tunnel

Using a frequency-doubled Nd-YAG pulsed laser and a single-intensified CCD camera, Rayleigh scattering measurements have been performed to study the cluster formation in a Mach 6 wind tunnel at NASA Langley Research Center. These studies were conducted both in the free stream and in a model flow field for various flow conditions to gain an understanding of the dependence of the Rayleigh scattering (by clusters) on the local pressures and temperatures in the facility. Using the same laser system, simultaneous measurements of the local temperature have also been performed using the rotational Raman scattering of molecular nitrogen and determined the densities of molecular oxygen and nitrogen by using the vibrational Raman scattering from these species. Quantitative results are presented in detail with emphasis on the applicability of the Rayleigh scattering for obtaining quantitative measurements of molecular densities both in the free stream and in the model flow field.

Shirinzadeh, B.↗