Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Formulation of detailed consumables management models for the development (preoperational) period of advanced space transportation system. Volume 3: Study of constraints/limitations for STS consumables management

The constraints and limitations for STS Consumables Management are studied. Variables imposing constraints on the consumables related subsystems are identified, and a method determining constraint violations with the simplified consumables model in the Mission Planning Processor is presented.

Newman, C. M.↗

The H I Lyman continuum in solar prominences and its interpretation in the presence of inhomogeneities

Observations of the H I Lyman continuum are presented for nine hedgerow prominences observed at the limb with the Harvard EUV spectrometer on Skylab. Methods of analysis for both the continuum emission and absorption are developed for two contrasting models for the prominence fine structure, namely multiple resolved slabs, and multiple unresolved cylindrical threads. The absorption data set a lower limit on the total optical thickness at 912 A and on the number of structures in the line of sight. The emission data yield a mean electron temperature of 7524 + or - 739 K and a mean brightness temperature of 6316 + or - 75 K. Taken together the emission and absorption data set firm constraints on the ionization, density, and fractional volume.

Orrall, F. Q.↗

An Einstein survey of the 1 keV soft X-ray background in the Galactic plane

We have analyzed 56 Einstein Observatory Imaging Proportional Counter (IPC) observations within +/- 3 deg of the Galactic plane in order to determine the low-latitude soft X-ray background flux in the 0.56-1.73 keV band. Any detected X-ray point source which fell within our regions of study was removed from the image, enabling us to present maps of the background flux as a function of Galactic latitude along 18 meridians. These maps reveal considerable structure to the background in the Galactic plane on an angular scale of approximately 1 deg. Our results are compared with those of an earlier study of the 1 keV X-ray background along l = 25 deg by Kahn & Caillault. The double-peaked structure they found is not discernible in our results, possibly because of the presence of solar backscattered flux in their data. A model which takes into account contributions to the background by extragalactic and stellar sources, the distribution of both atomic and molecular absorbing material with the Galaxy, the energy dependence of the cross section for absorption of X-rays, and the energy dependence of the detector has been constructed and fitted to these new data to derive constraints on the scale height, temperature, and volume emissivity of the unaccounted-for X-ray-emitting material. The results of this model along l = 25 deg are roughly similar to those of the model of Kahn & Caillault along the same meridian.

Stanford, John M.↗

Quench Module Insert (QMI) and the Diffusion Module Insert (DMI) Furnace Development

The Quench Module Insert (QMI) and the Diffusion Module Insert (DMI) are microgravity furnaces under development at Marshall Space Flight Center. The furnaces are being developed for the first Materials Science Research Rack (MSRR-1) of the Materials Science Research Facility (MSRF), one of the first International Space Station (ISS) scientific payloads. QMI is a Bridgman furnace with quench capability for studying interface behavior during directional solidification of metallic and alloy materials. DMI will be a Bridgman-Stockbarger furnace to study diffusion processes in semiconductors. The design for each insert, both QMI and DMI, is driven by specific science, operations and safety requirements, as well as by constraints arising from resource limitations, such as volume, mass and power. Preliminary QMI analysis and testing indicates that the design meets these requirements.

Crouch, Myscha R.↗

Cassini science planning process

The mission design for Cassini-Huygens calls for a four-year orbital survey of the Saturnian system and the descent into the Titan atmosphere and eventual soft-landing of the Huygens probe. The Cassini orbiter tour consists of 76 orbits around Saturn with 44 close Titan flybys and 8 targeted icy satellite flybys. The Cassini orbiter spacecraft carries twelve scientific instruments that will perform a wide range of observations on a multitude of designated targets. The science opportunities, frequency of encounters, the length of the Tour, and the use of distributed operations pose significant challenges for developing the science plan for the orbiter mission. The Cassini Science Planning Process is the process used to develop and integrate the science and engineering plan that incorporates an acceptable level of science required to meet the primary mission objectives far the orbiter. The bulk of the integrated science and engineering plan will be developed prior to Saturn Orbit Insertion (Sol). The Science Planning Process consists of three elements: 1) the creation of the Tour Atlas, which identifies the science opportunities in the tour, 2) the development of the Science Operations Plan (SOP), which is the conflict-free timeline of all science observations and engineering activities, a constraint-checked spacecraft pointing profile, and data volume allocations to the science instruments, and 3) an Aftermarket and SOP Update process, which is used to update the SOP while in tour with the latest information on spacecraft performance, science opportunities, and ephemerides. This paper will discuss the various elements of the Science Planning Process used on the Cassini Mission to integrate, implement, and adapt the science and engineering activity plans for Tour.

Cassini↗

Mars Ascent Vehicle Development Status

The Mars robotic sample return mission has been a potential flagship mission for NASA s science mission directorate for decades. The Mars Exploration Program and the planetary science decadal survey have highlighted both the science value of the Mars Sample Return (MSR) mission, but also the need for risk reduction through technology development. One of the critical elements of the MSR mission is the Mars Ascent Vehicle (MAV), which must launch the sample cache from the surface of Mars and place it into low Mars orbit. The MAV has significant challenges to overcome due to tight constraints on the MAV s mass and volume, as well as environmental challenges associated with long duration storage on the Martian surface and during Entry Descent and Landing (EDL). In the fall of 2010, NASA selected three industrial partners for study phase contracts to develop MAV system concepts, identify technology needs, and recommend technology developments plans for follow-on work. In addition to the contractor recommendations, JPL s Team-X was used for a comparative assessment of the three vehicle concepts to understand relative strengths, weaknesses, and sensitivity to system growth. The GRC COMPASS team independently evaluated MAV system solutions using liquid bipropellant, solid rocket motors, and an advanced monopropellant option. The results of the study phase contracts and comparative assessment is provided herein.

Dankanich, John W.↗

Machine Learning on Heterogeneous, Edge, and Quantum Hardware for Particle Physics (ML-HEQUPP)

The next generation of particle physics experiments will face a new era of challenges in data acquisition, due to unprecedented data rates and volumes along with extreme environments and operational constraints. Harnessing this data for scientific discovery demands real-time inference and decision-making, intelligent data reduction, and efficient processing architectures beyond current capabilities. Crucial to the success of this experimental paradigm are several emerging technologies, such as artificial intelligence and machine learning (AI/ML) and silicon microelectronics, and the advent of quantum algorithms and processing. Their intersection includes areas of research such as low-power and low-latency devices for edge computing, heterogeneous accelerator systems, reconfigurable hardware, novel codesign and synthesis strategies, readout for cryogenic or high-radiation environments, and analog computing. This white paper presents a community-driven vision to identify and prioritize research and development opportunities in hardware-based ML systems and corresponding physics applications, contributing towards a successful transition to the new data frontier of fundamental science.

Gonski, Julia [SLAC]↗

Larger, Lighter Space Telescopes by Implementing In-Space Manufacturing Concepts

There is a continuous demand for larger, lighter, and higher quality telescopes from both the astronomical and global surveillance communities one looking up and the other down. Enabling technologies must be developed and implemented that will allow this goal to be financially and technically feasible. The optical systems needed far high spatial resolution surveillance and astronomical applications require large optical, apertures with mention of future systems up to 150 meter in diameter. With traditional optical manufacturing technologies, large optical aperture means high mass and long fabrication lead times with associated high costs. Completely new approaches to optical fabrication must be developed to enable the fabrication of such optical systems. The cost and lead time associated with the fabrication of lightweight, high quality optical systems limits the feasible size of the optics. A primary factor in the launch cost of space optical systems is volume and mass. To minimize the mass of the high quality optics, optical fabricators implement materials with high specific stiffness and use honeycomb, or other structural minimization patterns, to support the optical surface; however, the structure must still be designed to survive launch loads. This sigmficantly adds to the fabrication difficulty and dramatically increases launch costs. One approach to minimizing launch volume and negating the need for the design to survive launch loads is to send the manufacturing facility and raw materials into space and perform the fabrication in-situ. We, are currently performing feasibility studies of initial concepts for inspace manufacturing of optical systems. By utilizing the micro-gravity and vacuum environment of space while eliminating the constraints defined by high launch forces and limited volume of the launch vehicle, the development of large, high quality glass membrane mirrors may be feasible. Several concepts were investigated to address the manufacturing of both optical surfaces and telescope structure. We will describe one of the primary approaches to utilize the space environment for optical manufacturing and describe initial results.

Mooney, James t.↗

Simulated Online Adaptive Magnetic Resonance–Guided Stereotactic Body Radiation Therapy for the Treatment of Oligometastatic Disease of the Abdomen and Central Thorax: Characterization of Potential Advantages

Purpose: To characterize potential advantages of online-adaptive magnetic resonance (MR)-guided stereotactic body radiation therapy (SBRT) to treat oligometastatic disease of the non-liver abdomen and central thorax. Methods and Materials: Ten patients treated with RT for unresectable primary or oligometastatic disease of the non-liver abdomen (n=5) or central thorax (n=5) underwent imaging throughout treatment on a clinical MR image guided RT system. The SBRT plans were created on the basis of tumor/organ at risk (OAR) anatomy at initial computed tomography simulation (P{sub I}), and simulated adaptive plans were created on the basis of observed MR image set tumor/OAR “anatomy of the day” (P{sub A}). Each P{sub A} was planned under workflow constraints to simulate online-adaptive RT. Prescribed dose was 50 Gy/5 fractions, with goal coverage of 95% planning target volume (PTV) by 95% of the prescription, subject to hard OAR constraints. The P{sub I} was applied to each MR dataset and compared with P{sub A} to evaluate changes in dose delivered to tumor/OARs, with dose escalation when possible. Results: Hard OAR constraints were met for all P{sub Is} based on anatomy from initial computed tomography simulation, and all P{sub As} based on anatomy from each daily MR image set. Application of the P{sub I} to anatomy of the day caused OAR constraint violation in 19 of 30 cases. Adaptive planning increased PTV coverage in 21 of 30 cases, including 14 cases in which hard OAR constraints were violated by the nonadaptive plan. For 9 P{sub A} cases, decreased PTV coverage was required to meet hard OAR constraints that would have been violated in a nonadaptive setting. Conclusions: Online-adaptive MRI-guided SBRT may allow PTV dose escalation and/or simultaneous OAR sparing compared with nonadaptive SBRT. A prospective clinical trial is underway at our institution to evaluate clinical outcomes of this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defining the “Hostile Pelvis” for Intensity Modulated Radiation Therapy: The Impact of Anatomic Variations in Pelvic Dimensions on Dose Delivered to Target Volumes and Organs at Risk in Patients With High-Risk Prostate Cancer Treated With Whole Pelvic Radiation Therapy

Purpose: The aim of this study was to evaluate the impact of variations in pelvic dimensions on the dose delivered to the target volumes and the organs at risk (OARs) in patients with high-risk prostate cancer (PCa) to be treated with whole pelvic radiation therapy (WPRT) in an attempt to define the hostile pelvis in terms of intensity modulated radiation therapy (IMRT). Methods and Materials: In 45 men with high-risk PCa to be treated with WPRT, the target volumes and the OARs were delineated, the dose constraints for the OARs were defined, and treatment plans were generated according to the Radiation Therapy Oncology Group 0924 protocol. Six dimensions to reflect the depth, width, and height of the bony pelvis were measured, and 2 indexes were calculated from the planning computed tomographic scans. The minimum dose (D{sub min}), maximum dose (D{sub max}), and mean dose (D{sub mean}) for the target volumes and OARs and the partial volumes of each of these structures receiving a specified dose (V{sub D}) were calculated from the dose-volume histograms (DVHs). The data from the DVHs were correlated with the pelvic dimensions and indexes. Results: According to an overall hostility score (OHS) calculation, 25 patients were grouped as having a hospitable pelvis and 20 as having a hostile pelvis. Regarding the OHS grouping, the DVHs for the bladder, bowel bag, left femoral head, and right femoral head differed in favor of the hospitable pelvis group, and the DVHs for the rectum differed for a range of lower doses in favor of the hospitable pelvis group. Conclusions: Pelvimetry might be used as a guide to define the challenging anatomy or the hostile pelvis in terms of treatment planning for IMRT in patients with high-risk PCa to be treated with WPRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric-modulated arc therapy vs conventional fixed-field intensity-modulated radiotherapy in a whole-ventricular irradiation: A planning comparison study

This study evaluated the dosimetric difference between volumetric-modulated arc therapy (VMAT) and conventional fixed-field intensity-modulated radiotherapy (cIMRT) in whole-ventricular irradiation. Computed tomography simulation data for 13 patients were acquired to create plans for VMAT and cIMRT. In both plans, the same median dose (100% = 24 Gy) was prescribed to the planning target volume (PTV), which comprised a tumor bed and whole ventricles. During optimization, doses to the normal brain and body were reduced, provided that the dose constraints of the target coverage were satisfied. The dose-volume indices of the PTV, normal brain, and body as well as monitor units were compared between the 2 techniques by using paired t-tests. The results showed no significant difference in the homogeneity index (0.064 vs 0.065; p = 0.824) of the PTV and conformation number (0.78 vs 0.77; p = 0.065) between the 2 techniques. In the normal brain and body, the dose-volume indices showed no significant difference between the 2 techniques, except for an increase in the volume receiving a low dose in VMAT; the absolute volume of the normal brain and body receiving 1 Gy of radiation significantly increased in VMAT by 1.6% and 8.3%, respectively, compared with that in cIMRT (1044 vs 1028 mL for the normal brain and 3079.2 vs 2823.3 mL for the body; p<0.001). The number of monitor units to deliver a 2.0-Gy fraction was significantly reduced in VMAT compared with that in cIMRT (354 vs 873, respectively; p<0.001). In conclusion, VMAT delivers IMRT to complex target volumes such as whole ventricles with fewer monitor units, while maintaining target coverage and conformal isodose distribution comparable to cIMRT; however, in addition to those characteristics, the fact that the volume of the normal brain and body receiving a low dose would increase in VMAT should be considered.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermal expansion and thermal stress in the moon and terrestrial planets - Clues to early thermal history

The paper discusses how features of the surface geology of the moon and also Mars and Mercury impose constraints on the volumetric expansion or contraction of a planet and consequently provide a test of thermal history models. The moon has changed very little in volume over the last 3.8 b.y. Thermal models satisfying this constraint involve early heating and perhaps melting of the outer 200 km of the moon and an initially cold interior. Mercury has contracted by about 2 km in radius since emplacement of its present surface, so core formation must predate that surface. A hot initial temperature distribution is implied.

Solomon, S. C.↗

Glass Property Models and Constraints for Estimating the Glass to be Produced at Hanford by Implementing Current Advanced Glass Formulation Efforts

Recent glass formulation and melter testing data have suggested that significant increases in waste loading in HLW and LAW glasses are possible over current system planning estimates. The data (although limited in some cases) were evaluated to determine a set of constraints and models that could be used to estimate the maximum loading of specific waste compositions in glass. It is recommended that these models and constraints be used to estimate the likely HLW and LAW glass volumes that would result if the current glass formulation studies are successfully completed. It is recognized that some of the models are preliminary in nature and will change in the coming years. Plus the models do not currently address the prediction uncertainties that would be needed before they could be used in plant operations. The models and constraints are only meant to give an indication of rough glass volumes and are not intended to be used in plant operation or waste form qualification activities. A current research program is in place to develop the data, models, and uncertainty descriptions for that purpose. A fundamental tenet underlying the research reported in this document is to try to be less conservative than previous studies when developing constraints for estimating the glass to be produced by implementing current advanced glass formulation efforts. The less conservative approach documented herein should allow for the estimate of glass masses that may be realized if the current efforts in advanced glass formulations are completed over the coming years and are as successful as early indications suggest they may be. Because of this approach there is an unquantifiable uncertainty in the ultimate glass volume projections due to model prediction uncertainties that has to be considered along with other system uncertainties such as waste compositions and amounts to be immobilized, split factors between LAW and HLW, etc.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-125: Dosimetric Comparison of Intensity Modulated Radiation Therapy Using Robotic Versus Traditional Linac Platform in Prostate Cancer

Purpose: Recent development of an MLC for robotic external beam radiotherapy has the potential of new clinical application in conventionally fractionated radiation therapy. This study offers a dosimetric comparison of IMRT plans using Cyberknife with MLC versus conventional linac plans. Methods: Ten prostate cancer patients treated on a traditional linac with IMRT to 7920cGy at 180cGy/fraction were randomly selected. GTVs were defined as prostate plus proximal seminal vesicles. PTVs were defined as GTV+8mm in all directions except 5mm posteriorly. Conventional IMRT planning was performed on Philips Pinnacle and delivered on a standard linac with CBCT and 10mm collimator leaf width. For each case a Cyberknife plan was created using Accuray Multiplan with same CT data set, contours, and dose constraints. All dosimetric data was transferred to third party software for independent computation of contour volumes and DVH. Delivery efficiency was evaluated using total MU, treatment time, number of beams, and number of segments. Results: Evaluation criteria including percent target coverage, homogeneity index, and conformity index were found to be comparable. All dose constraints from QUANTEC were found to be statistically similar except rectum V50Gy and bladder V65Gy. Average rectum V50Gy was lower for robotic IMRT (30.07%±6.57) versus traditional (34.73%±3.62, p=0.0130). Average bladder V65Gy was lower for robotic (17.87%±12.74) versus traditional (21.03%±11.93, p=0.0405). Linac plans utilized 9 coplanar beams, 48.9±3.8 segments, and 19381±2399MU. Robotic plans utilized 38.4±9.0 non-coplanar beams, 85.5±21.0 segments and 42554.71±16381.54 MU. The average treatment was 15.02±0.60 minutes for traditional versus 20.90±2.51 for robotic. Conclusion: The robotic IMRT plans were comparable to the traditional IMRT plans in meeting the target volume dose objectives. Critical structure dose constraints were largely comparable although statistically significant differences were found in favor of the robotic platform in terms of rectum V50Gy and bladder V65Gy at a cost of 25% longer treatment time.

60 APPLIED LIFE SCIENCES↗

Hippocampal dose from stereotactic radiosurgery for 4 to 10 brain metastases: Risk factors, feasibility of dose reduction via re-optimization, and patient outcomes

This study aimed to report hippocampal dose from single-fraction stereotactic radiosurgery (SRS) for 4 to 10 brain metastases and determine feasibility of hippocampal-sparing SRS. Patients with 4 to 10 brain metastases receiving single-isocenter, multi-target single-fraction SRS were identified. Hippocampi were contoured using the Radiation Therapy Oncology Group (RTOG) 0933 atlas. RTOG 0933 dose constraints were converted to a biologically effective dose using an alpha/beta of 2 (D{sub 100} 421 cGy, D{sub max} 665 cGy). Number of metastases, total target volume, prescribed dose, and distance of nearest metastasis (dmin) were analyzed as risk factors for exceeding hippocampal constraints. If hippocampi exceeded constraints, the SRS plan was re-optimized. Key dosimetric parameters were compared between original and re-optimized plans. To determine if a single target can exceed constraints, all targets but the closest metastasis were removed from the plan, and dosimetry was compared. Forty plans were identified. Fifteen hippocampi (19%) exceeded constraints in 12 SRS plans. Hippocampal sparing was achieved in 10 of 12 replanned cases (83%). Risk factors associated with exceeding hippocampal constraints were decreasing dmin (24.0 vs 8.0 mm, p = 0.002; odds ratio [OR] 1.14, 95% confidence interval [CI] 1.04 to 1.26) and total target volume (5.46 cm{sup 3}vs 1.98 cm{sup 3}, p = 0.03; OR 1.14, 95% CI 1.00 to 1.32). There was no difference in exceeding constraints for 4 to 5 vs 6 to 10 metastases (27% vs 21%, p = 0.409) or prescribed dose (18 Gy, p = 0.58). For re-optimized plans, there were no significant differences in planning target volume (PTV) coverage (99.6% vs 99.0%, p = 0.17) or conformality index (1.47 vs 1.4, p = 0.78). Six (50%) plans exceeded constraints with a single target. A substantial minority of hippocampi receive high radiation dose from SRS for 4 to 10 brain metastases. Decreasing distance of the closest metastasis and total target volume are associated with exceeding hippocampal constraints. Re-optimizing these plans yielded hippocampal-sparing SRS plans with acceptable dosimetry. Prospective evaluation of the impact of hippocampal dose from SRS on neurocognition merits consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity Modulated Radiation Therapy Dose Painting for Localized Prostate Cancer Using {sup 11}C-choline Positron Emission Tomography Scans

Purpose: To demonstrate the technical feasibility of intensity modulated radiation therapy (IMRT) dose painting using {sup 11}C-choline positron emission tomography PET scans in patients with localized prostate cancer. Methods and Materials: This was an RT planning study of 8 patients with prostate cancer who had {sup 11}C-choline PET scans prior to radical prostatectomy. Two contours were semiautomatically generated on the basis of the PET scans for each patient: 60% and 70% of the maximum standardized uptake values (SUV{sub 60%} and SUV{sub 70%}). Three IMRT plans were generated for each patient: PLAN{sub 78}, which consisted of whole-prostate radiation therapy to 78 Gy; PLAN{sub 78-90}, which consisted of whole-prostate RT to 78 Gy, a boost to the SUV{sub 60%} to 84 Gy, and a further boost to the SUV{sub 70%} to 90 Gy; and PLAN{sub 72-90}, which consisted of whole-prostate RT to 72 Gy, a boost to the SUV{sub 60%} to 84 Gy, and a further boost to the SUV{sub 70%} to 90 Gy. The feasibility of these plans was judged by their ability to reach prescription doses while adhering to published dose constraints. Tumor control probabilities based on PET scan-defined volumes (TCP{sub PET}) and on prostatectomy-defined volumes (TCP{sub path}), and rectal normal tissue complication probabilities (NTCP) were compared between the plans. Results: All plans for all patients reached prescription doses while adhering to dose constraints. TCP{sub PET} values for PLAN{sub 78}, PLAN{sub 78-90}, and PLAN{sub 72-90} were 65%, 97%, and 96%, respectively. TCP{sub path} values were 71%, 97%, and 89%, respectively. Both PLAN{sub 78-90} and PLAN{sub 72-90} had significantly higher TCP{sub PET} (P=.002 and .001) and TCP{sub path} (P<.001 and .014) values than PLAN{sub 78}. PLAN{sub 78-90} and PLAN{sub 72-90} were not significantly different in terms of TCP{sub PET} or TCP{sub path}. There were no significant differences in rectal NTCPs between the 3 plans. Conclusions: IMRT dose painting for localized prostate cancer using {sup 11}C-choline PET scans is technically feasible. Dose painting results in higher TCPs without higher NTCPs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing the low-dose lung radiation for central lung tumors by restricting the IMRT beams and arc arrangement

To compare the extent to which 7 different radiotherapy planning techniques for mediastinal lung targets reduces the lung volume receiving low doses of radiation. Thirteen non-small cell lung cancer patients with targets, including the mediastinal nodes, were identified. Treatment plans were generated to both 60- and 74-Gy prescription doses using 7 different planning techniques: conformal, hybrid conformal/intensity-modulated radiation treatment (IMRT), 7 equidistant IMRT beams, 2 restricted beam IMRT plans, a full (360 Degree-Sign ) modulated arc, and a restricted modulated arc plan. All plans were optimized to reduce total lung V5, V10, and V20 volumes, while meeting normal tissue and target coverage constraints. The mean values for the 13 patients are calculated for V5, V10, V20, V{sub ave}, V0-20, and mean lung dose (MLD) lung parameters. For the 74-Gy prescription dose, the mean lung V10 was 42.7, 43.6, 48.2, 56.6, 57, 55.8, and 54.1% for the restricted {+-}36 Degree-Sign IMRT, restricted modulated arc, restricted {+-}45 Degree-Sign IMRT, full modulated arc, hybrid conformal/IMRT, equidistant IMRT, and conformal plans, respectively. A similar lung sparing hierarchy was found for the 60-Gy prescription dose. For the treatment of central lung targets, the {+-}36 Degree-Sign restricted IMRT and restricted modulated arc planning techniques are superior in lowering the lung volume treated to low dose, as well as in minimizing MLD, followed by the {+-}45 Degree-Sign restricted IMRT plan. All planning techniques that allow the use of lateral or lateral/oblique beams result in spreading the low dose over a higher lung volume. The area under the lung dose-volume histogram curve below 20 Gy, V0-20, is proposed as an alternative to individual V{sub dose} parameters, both as a measure of lung sparing and as a parameter to be minimized during IMRT optimization.

61 RADIATION PROTECTION AND DOSIMETRY↗