Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Heating Season Energy and Moisture Levels

Two identical laboratory homes designed to model existing Florida building stock were sealed and tested to 2.5 ACH50. Then, one was made leaky with 70% leakage through the attic and 30% through windows, to a tested value of 9 ACH50. Reduced energy use was measured in the tighter home (2.5 ACH50) in the range of 15% to 16.5% relative to the leaky (9 ACH50) home. Internal moisture loads resulted in higher dew points inside the tight home than the leaky home. Window condensation and mold growth occurred inside the tight home. Even cutting internal moisture gains in half to 6.05 lbs/day, the dew point of the tight home was more than 15 degrees F higher than the outside dry bulb temperature. The homes have single pane glass representative of older Central Florida homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating, Ventilation, and Air Conditioning Design Strategy for a Hot-Humid Production Builder

BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating, Ventilation, and Air Conditioning Design Strategy for a Hot-Humid Production Builder

Building Science Corporation (BSC) worked directly with the David Weekley Homes - Houston division to develop a cost-effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses in preparation for the upcoming code changes in 2015. This research project addressed the following questions: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Turnkey Heating, Ventilating, and Air Conditioning and Lighting Retrofit Solution Combining Energy Efficiency and Demand Response Benefits

NREL worked with the Bonneville Power Administration's Technology Innovation Office to demonstrate a turnkey, retrofit technology that combines demand response (DR) and energy efficiency (EE) benefits for HVAC and lighting in retail buildings. As a secondary benefit, we also controlled various plug loads and electric hot water heaters (EHWH). The technology demonstrated was Transformative Wave's eIQ Building Management System (BMS) automatically responding to DR signals. The BMS controlled the HVAC rooftop units (RTU) using the CATALYST retrofit solution also developed by Transformative Wave. The non-HVAC loads were controlled using both hardwired and ZigBee wireless communication. The wireless controllers, manufactured by Autani, were used when the building's electrical layout was too disorganized to leverage less expensive hardwired control. The six demonstration locations are within the Seattle metro area. Based on the assets curtailed by the BMS at each location, we projected the DR resource. We were targeting a 1.7 W/ft2 shed for the summer Day-Ahead events and a 0.7 W/ft2 shed for the winter events. While summarized in Table ES-1, only one summer DR event was conducted at Casino #2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simple model of the effect of ocean ventilation on ocean heat uptake

Presentation includes slides on Earth System Models vs. Simple Climate Models; A Popular SCM: Energy Balance Model of Anomalies; On calibrating against one ESM experiment, the SCM correctly captures that ESM's surface warming response with other forcings; Multi-Model Analysis: Multiple ESMs, Single SCM; Posterior Distributions of ECS; However In Excess of 90% of TOA Energy Imbalance is Sequestered in the World Oceans; Heat Storage in the Two Layer Model; Heat Storage in the Two Layer Model; Including TOA Rad. Imbalance and Ocean Heat in Calibration Improves Repr., but Significant Errors Persist; Improved Vertical Resolution Does Not Fix Problem; A Series of Expts. Confirms That Anomaly-Diffusing Models Cannot Properly Represent Ocean Heat Uptake; Physics of the Thermocline; Outcropping Isopycnals and Horizontally-Averaged Layers; Local interactions between outcropping isopycnals leads to non-local interactions between horizontally-averaged layers; Both Surface Warming and Ocean Heat are Well Represented With Just 4 Layers; A Series of Expts. Confirms That When Non-Local Interactions are Allowed, the SCMs Can Represent Both Surface Warming and Ocean Heat Uptake; and Summary and Conclusions.

58 GEOSCIENCES↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

Low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. This report evaluates the performance of variable-capacity comfort systems, with a focus on inverter-driven, variable-capacity systems, as well as proposed system enhancements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype Ceramic High Efficiency Particulate Air Filter Testing and Filter Media Development for Nuclear Facility Ventilation

This report summarizes recent and past related Ceramic HEPA Filter activity for this NNSA NSR&D project and on-going plans for FY18 and FY19 work as presently planned. Prior work has evaluated concepts for a ceramic HEPA filter including ceramic support materials, filter media including electrospun filter media, and metal housing designs to accommodate the conservative temperature performance target of up to 500°C. This has been supported by modelling efforts discussed with nuclear facility system engineers and their management. The temperature and time-at-temperature are based on conservative, bounding temperatures from fire analysis presented as a draft EFCOG best practice paper for nuclear facility safety analysis. The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology including increasing performance while reducing pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases. The goal of the ceramic HEPA filter is to provide a robust HEPA filter that provides increased temperature performance in an equivalent form factor (size and shape) that is similar to existing conventional HEPA filters used in facilities. Once qualified for use in facilities, the benefit of a ceramic HEPA filters could simplify and reduce safety and support system costs, as well as considerably lower life-cycle costs. Installation, monitoring, and maintenance of active fire suppression systems, as well as other related systems, are a considerable on-going cost to nuclear facilities. Reducing the level of dependence on Safety Class and Safety Significant fire alarm and fire suppression systems could allow significant cost savings. At present we are continuing research and development efforts towards the goal of a ceramic filter design, including improved ceramic filter media, that could reduce total operation cost for facilities utilizing HEPA filters.

42 ENGINEERING↗

NSRD-12, Novel Mini-Tubular HEPA Media for Nuclear Facility Ventilation Systems

The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology, increasing performance while reducing pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases.The primary objective of this report is to demonstrate that mini-tubular ceramic (MTC) media can reduce pressure drop across a filter compared to flow through a membrane. A secondary objective is to obtain a baseline filtration efficiency measurement. Reducing pressure drop across a filter through MTC design can be combined with nanofiber technology to improve filter performance. Developing MTC media can also solve processing challenges associated with manufacturing ceramic nanofiber membranes and coatings by electrospinning. This work will support developing specifications for industry codes and standards such as ASME AG-1, Subsection FO, Ceramic Filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for Tank 31H

The SRNL Atmospheric Technologies Group performed an analysis of mercury emissions from the H-Tank Farm Tank 31-H to assess worst case 15-minute, 1-hour and 8-hour average concentrations and evaluate whether the ACIGH Short-Term Exposure Limit (STEL), PAC (Protection Action Criteria), or Threshold Limit Value (TLV) levels for mercury are exceeded. This analysis was also used to establish a minimum stack height at which ambient mercury concentration would not exceed the regulatory limits. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. The PAC standard is not exceeded for any of the stack heights, or release scenario. A 92 ft stack for the 25 mg/m 3 modeling scenario and 95 ft for the 50 mg/m 3 are necessary to prevent all exceedances at all receptors. If the highest receptor on the Evaporator West Stack Platform is excluded from the domain, then the maximum heights are 35 ft and 52 ft for the 25 mg/m 3 and the 50 mg/m 3 modeling scenarios, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prototype Ceramic HEPA Filter Testing and Filter Media Research and Development for Nuclear Facility Ventilation

This is a brief summary of recent and past Ceramic HEPA Filter research and development activities under an NNSA NSR&D funded project and describes on-going plans for FY19 work as presently planned. Prior work has evaluated concepts for a ceramic HEPA filter including ceramic support materials, filter media including electrospun filter media, and metal housing designs to accommodate the conservative temperature performance target of up to 500°C. This has been supported by modelling efforts discussed with nuclear facility system engineers and their management. The temperature and time-attemperature are based on conservative, bounding temperatures from fire analysis presented as an EFCOG best practice paper for nuclear facility safety analysis. The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology including increasing temperature performance while maintaining acceptable filter pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases. The goal of the ceramic HEPA filter is to provide a HEPA filter that provides increased temperature performance in an equivalent form factor (size and shape) that is similar to existing conventional HEPA filters used in facilities. Once development is complete and qualified for use in facilities, ceramic HEPA filters could simplify and reduce safety and support system costs, as well as lower life-cycle costs. Installation, monitoring, and maintenance of active fire suppression systems, as well as other related systems, are a considerable on-going cost to nuclear facilities. Reducing the level of dependence on Safety Class and Safety Significant fire alarm and fire suppression systems could allow significant cost savings. At present we are continuing research and development efforts towards the goal of a ceramic filter design, including improved ceramic filter media, that could reduce total operation cost for facilities utilizing HEPA filters.

36 MATERIALS SCIENCE↗

Prototype Ceramic HEPA Filter Testing and Filter Media Research and Development for Nuclear Facility Ventilation

This is a brief summary of recent and past Ceramic HEPA Filter research and development activities under an NNSA NSR&D funded project and describes on-going plans for FY19 work as presently planned. Prior work has evaluated concepts for a ceramic HEPA filter including ceramic support materials, filter media including electrospun filter media, and metal housing designs to accommodate the conservative temperature performance target of up to 500°C. This has been supported by modelling efforts discussed with nuclear facility system engineers and their management. The temperature and time-at-temperature are based on conservative, bounding temperatures from fire analysis presented as an EFCOG best practice paper for nuclear facility safety analysis. The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology including increasing temperature performance while maintaining acceptable filter pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases. The goal of the ceramic HEPA filter is to provide a HEPA filter that provides increased temperature performance in an equivalent form factor (size and shape) that is similar to existing conventional HEPA filters used in facilities. Once development is complete and qualified for use in facilities, ceramic HEPA filters could simplify and reduce safety and support system costs, as well as lower life-cycle costs. Installation, monitoring, and maintenance of active fire suppression systems, as well as other related systems, are a considerable on-going cost to nuclear facilities. Reducing the level of dependence on Safety Class and Safety Significant fire alarm and fire suppression systems could allow significant cost savings, while maintaining safety. At present we are continuing research and development efforts towards the goal of a ceramic filter design, including improved ceramic filter media, that could reduce total operation cost for facilities utilizing HEPA filters.

36 MATERIALS SCIENCE↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for Tank 35H Bulk Sludge Removal

The SRNL Atmospheric Technologies Group performed an analysis of mercury emissions from the H-Tank Farm Tank 35-H to assess worst case 15-minute, 1-hour and 8-hour average concentrations and evaluate whether the ACIGH Short-Term Exposure Limit (STEL), PAC (Protection Action Criteria), or Threshold Limit Value (TLV) levels for mercury are exceeded. This analysis was also used to establish a minimum stack height at which ambient mercury concentration would not exceed the regulatory limits. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. The PAC standard is not exceeded for any of the stack heights, or release scenario. A 100 ft stack for the 50 mg/m 3 modeling scenario and 110 ft for the 100 mg/m3 are necessary to prevent all exceedances at all receptors. If the highest receptor on the Evaporator West Stack Platform is excluded from the domain, then the maximum heights are 65 ft and 105 ft for the 50 mg/m 3 and the 100 mg/m 3 modeling scenarios, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for SDUs

The SRNL Atmospheric Technologies Group performed an analysis to determine the minimum stack height necessary to avoid exceedance of the ACGIH (American Conference of Governmental Industrial Hygienists) 15-minute Short-Term Exposure Limit (STEL) and 8-hour Time Weighted Average (TWA) ambient standards for worst case hazardous chemical emissions from the Z-Area Mega SDUs. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. Receptors were placed to represent the breathing level concentrations that workers might have, placed 6-ft above the working surface (ground or SDU tank surface). Based on the analysis conducted, the minimum SDU exhaust release height to avoid exceeding STEL and TWA is 6 feet above the SDU roof level for flow rates between 300 and 1200 cfm. The configuration of Mega SDUs, while large structures, do not produce an aerodynamic wake that impacts the stack releases and causes exceedances to the worker exposure limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗