Dose--response of initial G2-chromatid breaks induced in normal human fibroblasts by heavy ions

PURPOSE: To investigate initial chromatid breaks in prematurely condensed G2 chromosomes following exposure to heavy ions of different LET. MATERIAL AND METHODS: Exponentially growing human fibroblast cells AG1522 were irradiated with gamma-rays, energetic carbon (13 keV/ microm, 80 keV/microm), silicon (55 keV/microm) and iron (140 keV/microm, 185keV/microm, 440keV/microm) ions. Chromosomes were prematurely condensed using calyculin-A. Initial chromatid-type and isochromatid breaks in G2 cells were scored. RESULTS: The dose response curves for total chromatid breaks were linear regardless of radiation type. The relative biological effectiveness (RBE) showed a LET-dependent increase, peaking around 2.7 at 55-80keV/microm and decreasing at higher LET. The dose response curves for isochromatid-type breaks were linear for high-LET radiations, but linear-quadratic for gamma-rays and 13 keV/microm carbon ions. The RBE for the induction of isochromatid breaks obtained from linear components increased rapidly between 13keV/microm (about 7) and 80keV/microm carbon (about 71), and decreased gradually until 440 keV/microm iron ions (about 66). CONCLUSIONS: High-LET radiations are more effective at inducing isochromatid breaks, while low-LET radiations are more effective at inducing chromatid-type breaks. The densely ionizing track structures of heavy ions and the proximity of sister chromatids in G2 cells result in an increase in isochromatid breaks.

Non-NASA Center↗

Displacement damage caused by gamma-rays and neutrons on Au and Se.

This report documents theoretical calculations of displacement damage produced by gamma rays and neutrons on various materials. The average energy of the gamma rays was 1.24 MeV and 1.0 MeV for the neutrons. The fluence of the gamma rays was 1.2e14 γ/cm 2 , for the neutrons it was 1.0e12 n/cm2. The initial materials of interest were Au and Se. The total doses of the gamma ray exposures were in the 100 kRad range for both elements. An equivalent electron fluence was approximated to be the same as the gamma ray fluence over one gamma ray attenuation length in both materials and at the same 1.24 MeV energy. The maximum recoil energy of the Au and Se for these electrons was calculated relativisticaly to be 29 and 72 eV respectively. The relativisitic McKinley and Feshbach theory for the atomic recoil cross sections produced by the electrons were in the 10s of mbarn range and an upper limit for the concentration of Frenkel pairs for the gamma ray exposures for both elements was in the ppb range. The Robinson Energy Partioning Theory for non-ionizing energy loss (NIEL) of ions in solids was used to calculate the concentration of Frenkel pairs produced by the 1 MeV neutrons, and this concentration was also in the ppb range for both Au and Se. Low damage levels like this can have effects on minority carrier recombination in semiconductors, but are not expected to have any effect on metals like Au, or metalloids such as Se.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom

Purpose: To avoid complications in total body irradiation (TBI), it is important to achieve a homogeneous dose distribution throughout the body and to deliver a correct dose to the lung which is an organ at risk. The purpose of this work was to validate the TBI dose protocol and to check the accuracy of the 3D dose calculations of the treatment planning system. Methods: Dosimetry based on alanine/electron paramagnetic resonance (EPR) was used to measure dose at numerous locations within an anthropomorphic phantom (Alderson) that was irradiated in a clinical TBI beam setup. The alanine EPR dosimetry system was calibrated against water calorimetry in a Co-60 beam and the absorbed dose was determined by the use of ''dose-normalized amplitudes'' A{sub D}. The dose rate of the TBI beam was checked against a Farmer ionization chamber. The phantom measurements were compared to 3D dose calculations from a treatment planning system (Pinnacle) modeled for standard dose calculations. Results: Alanine dosimetry allowed accurate measurements which were in accordance with ionization chamber measurements. The combined relative standard measurement uncertainty in the Alderson phantom was U{sub r}(A{sub D})=0.6%. The humanoid phantom was irradiated to a reference dose of 10 Gy, limiting the lung dose to 7.5 Gy. The ratio of the average measured dose midplane in the craniocaudal direction to the reference dose was 1.001 with a spread of {+-}4.7% (1 sd). Dose to the lung was measured in 26 locations and found, in average, 1.8% lower than expected. Lung dose was homogeneous in the ventral-dorsal direction but a dose gradient of 0.10 Gy cm{sup -1} was observed in the craniocaudal direction midline within the lung lobe. 3D dose calculations (Pinnacle) were found, in average, 2% lower compared to dose measurements on the body axis and 3% lower for the lungs. Conclusions: The alanine/EPR dosimetry system allowed accurate dose measurements which enabled the authors to validate their TBI dose protocol. Dose calculations based on a collapsed cone convolution dose algorithm modeled for regular treatments are accurate within 3% and can further be improved when the algorithm is modeled for TBI.

61 RADIATION PROTECTION AND DOSIMETRY↗

EFFECTS OF GAMMA IRRADIATION ON EPDM ELASTOMERS

Two formulations of EPDM elastomer, one substituting a UV stabilizer for the normal antioxidant in this polymer, and the other the normal formulation, were synthesized and samples of each were exposed to gamma irradiation in initially pure deuterium gas to compare their radiation stability. Stainless steel containers having rupture disks were designed for this task. After 130 MRad dose of cobalt-60 radiation in the SRNL Gamma Irradiation Facility, a significant amount of gas was created by radiolysis; however the composition indicated by mass spectroscopy indicated an unexpected increase in the total amount deuterium in both formulations. The irradiated samples retained their ductility in a bend test. No change of sample weight, dimensions, or density was observed. No change of the glass transition temperature as measured by dynamic mechanical analysis was observed, and most of the other dynamic mechanical properties remained unchanged. There appeared to be an increase in the storage modulus of the irradiated samples containing the UV stabilizer above the glass transition, which may indicate hardening of the material by radiation damage. Polymeric materials become damaged by exposure over time to ionizing radiation. Despite the limited lifetime, polymers have unique engineering material properties and polymers continue to be used in tritium handling systems. In tritium handling systems, polymers are employed mainly in joining applications such as valve sealing surfaces (eg. Stem tips, valve packing, and O-rings). Because of the continued need to employ polymers in tritium systems, over the past several years, programs at the Savannah River National Laboratory have been studying the effect of tritium on various polymers of interest. In these studies, samples of materials of interest to the SRS Tritium Facilities (ultra-high molecular weight polyethylene (UHMW-PE), polytetrafluoroethylene (PTFE, Teflon{reg_sign}), Vespel{reg_sign} polyimide, and the elastomer ethylene propylene diene monomer (EPDM)) have been exposed in closed containers to tritium gas initially at 1 atmosphere pressure. These studies have demonstrated the degradation of properties when exposed to tritium gas. Also, the radiolytic production of significant amounts of hydrogen has been observed for UHMW-PE and EPDM. The study documented in this report exposes two similar formulations of EPDM elastomer to gamma irradiation in a closed container backfilled with deuterium. Deuterium is chemically identical to protium and tritium, but allows the identification of protium that is radiolytically produced from the samples. The goal of this program is to compare and contrast the response of EPDM exposure to two different types of ionizing radiation in a similar chemical environment.

36 MATERIALS SCIENCE↗

Why ionizing radiation enhances surface wettability

Radiation-Induced Surface Activation is an inherent phenomenon where surfaces that are exposed to gamma irradiation are observed to undergo an increase in wettability. This increase in wettability as a result of the ionizing radiation exposure has so far been demonstrated to have a pronounced impact on Leidenfrost temperature and two-phase fluid dynamics. Test results from previous experiments have shown that incorporation of this effect on heat transfer equipment design may increase the thermal-hydraulic margin leading to higher thermal efficiency. However, the mechanism behind the increased wettability is not clearly understood. In the present work, three different materials (Zircaloy-4, 316 stainless steel, and copper) were exposed at two different dose rates with use of two different gamma irradiation facilities. A detailed surface characterization on the post-irradiated samples is carried out to understand the changes in surface chemistry, wettability and surface morphology. It is observed from the experiments that the increase in wettability upon irradiation depended on the total dose and not on the dose rate. Moreover, localized oxidation and porosity induced by radiolysis was seen to be the predominant mechanism behind increased wettability which leads to improved Leidenfrost temperature.

36 MATERIALS SCIENCE↗

Why ionizing radiation enhances surface wettability

Radiation-Induced Surface Activation is an inherent phenomenon where surfaces that are exposed to gamma irradiation are observed to undergo an increase in wettability. This increase in wettability as a result of the ionizing radiation exposure has so far been demonstrated to have a pronounced impact on Leidenfrost temperature and two-phase fluid dynamics. Test results from previous experiments have shown that incorporation of this effect on heat transfer equipment design may increase the thermal-hydraulic margin leading to higher thermal efficiency. However, the mechanism behind the increased wettability is not clearly understood. In the present work, three different materials (Zircaloy-4, 316 stainless steel, and copper) were exposed at two different dose rates with use of two different gamma irradiation facilities. A detailed surface characterization on the post-irradiated samples is carried out to understand the changes in surface chemistry, wettability and surface morphology. It is observed from the experiments that the increase in wettability upon irradiation depended on the total dose and not on the dose rate. Moreover, localized oxidation and porosity induced by radiolysis was seen to be the predominant mechanism behind increased wettability which leads to improved Leidenfrost temperature.

Seshadria, Arunkumar↗

Accelerator Developments and their Application to Cancer Therapy

Basic phenomena in irradiations of X-ray and particle beams and comparison among various radiations are described. Total doses and fractionations for several sites in case of carbon beam are shown in comparison with X-ray and proton beam. Typical results of carbon beam treatments are shown. Original facility was too large. Then, smaller design of 2{sup nd} stage facility of carbon therapy was carried out as well as the further technical developments.

43 PARTICLE ACCELERATORS↗

SU-F-T-142: An Analytical Model to Correct the Aperture Scattered Dose in Clinical Proton Beams

Purpose: Apertures or collimators are used to laterally shape proton beams in double scattering (DS) delivery and to sharpen the penumbra in pencil beam (PB) delivery. However, aperture-scattered dose is not included in the current dose calculations of treatment planning system (TPS). The purpose of this study is to provide a method to correct the aperture-scattered dose based on an analytical model. Methods: A DS beam with a non-divergent aperture was delivered using a single-room proton machine. Dose profiles were measured with an ion-chamber scanning in water and a 2-D ion chamber matrix with solid-water buildup at various depths. The measured doses were considered as the sum of the non-contaminated dose and the aperture-scattered dose. The non-contaminated dose was calculated by TPS and subtracted from the measured dose. Aperture scattered-dose was modeled as a 1D Gaussian distribution. For 2-D fields, to calculate the scatter-dose from all the edges of aperture, a sum of weighted distance was used in the model based on the distance from calculation point to aperture edge. The gamma index was calculated between the measured and calculated dose with and without scatter correction. Results: For a beam with range of 23 cm and aperture size of 20 cm, the contribution of the scatter horn was ∼8% of the total dose at 4 cm depth and diminished to 0 at 15 cm depth. The amplitude of scatter-dose decreased linearly with the depth increase. The 1D gamma index (2%/2 mm) between the calculated and measured profiles increased from 63% to 98% for 4 cm depth and from 83% to 98% at 13 cm depth. The 2D gamma index (2%/2 mm) at 4 cm depth has improved from 78% to 94%. Conclusion: Using the simple analytical method the discrepancy between the measured and calculated dose has significantly improved.

60 APPLIED LIFE SCIENCES↗

DNA Repair and Cell Cycle Biomarkers of Radiation Exposure and Inflammation Stress in Human Blood

DNA damage and repair are hallmarks of cellular responses to ionizing radiation. We hypothesized that monitoring the expression of DNA repair-associated genes would enhance the detection of individuals exposed to radiation versus other forms of physiological stress. We employed the human blood ex vivo radiation model to investigate the expression responses of DNA repair genes in repeated blood samples from healthy, non-smoking men and women exposed to 2 Gy of X-rays in the context of inflammation stress mimicked by the bacterial endotoxin lipopolysaccharide (LPS). Radiation exposure significantly modulated the transcript expression of 12 genes of 40 tested (2.2E-06,p,0.03), of which 8 showed no overlap between unirradiated and irradiated samples (CDKN1A, FDXR, BBC3, PCNA, GADD45a, XPC, POLH and DDB2). This panel demonstrated excellent dose response discrimination (0.5 to 8 Gy) in an independent human blood ex vivo dataset, and 100% accuracy for discriminating patients who received total body radiation. Three genes of this panel (CDKN1A, FDXR and BBC3) were also highly sensitive to LPS treatment in the absence of radiation exposure, and LPS co-treatment significantly affected their radiation responses. At the protein level, BAX and pCHK2-thr68 were elevated after radiation exposure, but the pCHK2-thr68 response was significantly decreased in the presence of LPS. Our combined panel yields an estimated 4-group accuracy of ,90% to discriminate between radiation alone, inflammation alone, or combined exposures. Our findings suggest that DNA repair gene expression may be helpful to identify biodosimeters of exposure to radiation, especially within high-complexity exposure scenarios.

59 BASIC BIOLOGICAL SCIENCES↗

Detailed Radiation Dose Rate Evaluations of Commercial Spent Nuclear Fuel Canisters

Electronic devices that are being designed for continuous monitoring of spent nuclear fuel (SNF) canister internal integrity may be subjected to very high radiation levels depending on their placement. Components of electronic devices (e.g., silicon semiconductors, optical glasses, insulators) have a limited tolerance to ionizing radiation. For selected locations on the inner and outer surfaces of a representative dry storage pressurized water reactor (PWR) SNF canister and a representative dry storage boiling water reactor (BWR) SNF canister, this paper provides (1) the dose rate in silicon as a function of decay time and (2) the time-integrated dose in silicon. The analyzed decay time interval is from 5 to 70 years after fuel discharge. Each representative canister contained identical SNF assemblies with bounding radiation sources. Surface dose rates varied significantly as a function of location and SNF assembly decay time. At a 5-year decay time, the estimated maximum dose rate values were 480 Gy/h (PWR canister) and ~366 Gy/h (BWR canister), and the estimated minimum dose rate was ~0.2 Gy/h for both canisters. Over a 65-year period, the dose rate decreased by a factor between 13 and 580, depending on location. The total dose over a time interval could be very large (e.g., estimated maximum value over a 5-year interval is 1.5E+07 Gy) depending on location and the time interval over which dose is accumulated.

Radulescu, Georgeta↗

Endocavitary in vivo Dosimetry for IMRT Treatments of Gynecologic Tumors

The accuracy and reproducibility of endometrial carcinoma treatment with intensity-modulated radiotherapy (IMRT) was assessed by means of in vivo dosimetry. Six patients who had previously undergone radical hysterectomy for endometrial carcinoma were treated with IMRT using a vaginal applicator with radio-opaque fiducial markers. An ion-chamber inserted into the applicator supplied an endocavitary in vivo dosimetry for quality assurance purposes. The ratio R = D/D{sub TPS} between the in vivo measured dose D and the predicted dose by the treatment planning system D{sub TPS} was determined for every fraction of the treatment. Results showed that 90% and 100% of the ratios resulted equal to 1 within 5% and 10%, respectively. The mean value of the ratios distribution for the 6 patients was R = 0.995 and the SD = 0.034. The ratio R* between the measured and predicted total doses for each patient was near to 1, within 2%. The dosimetric results suggest that the use of a vaginal applicator in an image-guided approach could make the interfractions target position stable and reproducible, allowing a safe use of the IMRT technique in the treatment of postoperative vaginal vault. In vivo dosimetry may supply useful information about the discrimination of random vs. systematic errors. The workload is minimum and this in vivo dosimetry can be applied also in the clinical routine.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-C-12A-04: Dosimetric Evaluation of a Modulated Arc Technique for Total Body Irradiation

Purpose: A simplified Total Body Irradiation (TBI) was developed to work with minimal requirements in a compact linac room without custom motorized TBI couch. Results were compared to our existing fixed-gantry double 4 MV linac TBI system with prone patient and simultaneous AP/PA irradiation. Methods: Modulated arc irradiates patient positioned in prone/supine positions along the craniocaudal axis. A simplified inverse planning method developed to optimize dose rate as a function of gantry angle for various patient sizes without the need of graphical 3D treatment planning system. This method can be easily adapted and used with minimal resources. Fixed maximum field size (40×40 cm2) is used to decrease radiation delivery time. Dose rate as a function of gantry angle is optimized to result in uniform dose inside rectangular phantoms of various sizes and a custom VMAT DICOM plans were generated using a DICOM editor tool. Monte Carlo simulations, film and ionization chamber dosimetry for various setups were used to derive and test an extended SSD beam model based on PDD/OAR profiles for Varian 6EX/ TX. Measurements were obtained using solid water phantoms. Dose rate modulation function was determined for various size patients (100cm − 200cm). Depending on the size of the patient arc range varied from 100° to 120°. Results: A PDD/OAR based beam model for modulated arc TBI therapy was developed. Lateral dose profiles produced were similar to profiles of our existing TBI facility. Calculated delivery time and full arc depended on the size of the patient (∼8min/ 100° − 10min/ 120°, 100 cGy). Dose heterogeneity varied by about ±5% − ±10% depending on the patient size and distance to the surface (buildup region). Conclusion: TBI using simplified modulated arc along craniocaudal axis of different size patients positioned on the floor can be achieved without graphical / inverse 3D planning.

60 APPLIED LIFE SCIENCES↗

SU-E-T-644: QuAArC: A 3D VMAT QA System Based On Radiochromic Film and Monte Carlo Simulation of Log Files

Purpose: VMAT involves two main sources of uncertainty: one related to the dose calculation accuracy, and the other linked to the continuous delivery of a discrete calculation. The purpose of this work is to present QuAArC, an alternative VMAT QA system to control and potentially reduce these uncertainties. Methods: An automated MC simulation of log files, recorded during VMAT treatment plans delivery, was implemented in order to simulate the actual treatment parameters. The linac head models and the phase-space data of each Control Point (CP) were simulated using the EGSnrc/BEAMnrc MC code, and the corresponding dose calculation was carried out by means of BEAMDOSE, a DOSXYZnrc code modification. A cylindrical phantom was specifically designed to host films rolled up at different radial distances from the isocenter, for a 3D and continuous dosimetric verification. It also allows axial and/or coronal films and point measurements with several types of ion chambers at different locations. Specific software was developed in MATLAB in order to process and evaluate the dosimetric measurements, which incorporates the analysis of dose distributions, profiles, dose difference maps, and 2D/3D gamma index. It is also possible to obtain the experimental DVH reconstructed on the patient CT, by an optimization method to find the individual contribution corresponding to each CP on the film, taking into account the total measured dose, and the corresponding CP dose calculated by MC. Results: The QuAArC system showed high reproducibility of measurements, and consistency with the results obtained with the commercial system implemented in the verification of the evaluated treatment plans. Conclusion: A VMAT QA system based on MC simulation and high resolution dosimetry with film has been developed for treatment verification. It shows to be useful for the study of the real VMAT capabilities, and also for linac commissioning and evaluation of other verification devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-19A-02: Characterization of An Actively Controlled Graphite Probe Calorimeter

Purpose: To construct and experimentally evaluate the performance of a miniature probe-format graphite calorimeter (GPC) with built-in active control. The GPC is the first ever calorimeter designed specifically for routine clinical use. Methods: The original GPC design, developed as part of our previous work, was modified to accommodate a micro-thin, resistive heating element and sensing thermistors embedded in the outermost graphite layer. A software-based process control loop was written to maintain a predefined set point temperature throughout the detector by precisely modulating the current flowing through the resistive element. Continuous feedback is provided to the controller by the additional thermistors. A functioning prototype was constructed in-house and operated in adiabatic mode in a 6 MV photon beam. Ten sets of measurements of varying duration (10 to 60 seconds) and repetition rate (200 to 600 MU/min) were analyzed. Reproducibility, linearity and dose rate dependence were assessed. Results: A total of 47 individual measurements were performed using the active GPC. The reproducibility, defined here as the sample standard deviation weighted across all 10 measurement sets, was found to be 0.37%. Similarly, the standard error (type A uncertainty) was 0.17%. Linearity was quantified by plotting signal as a function of monitor units delivered at 600 MU/min. The adjusted R-square of the resulting linear fit was 0.9996. Dose rate dependence, evaluated as the change in normalized response (signal/MU) as a function of repetition rate, was found to be statistically insignificant. Conclusions: The incorporation of active control has resulted in a marked improvement in the GPC's reproducibility and it allows the user to now perform measurements within minutes of setup. With this refinement, it is estimated that the overall standard uncertainty in the absolute determination of dose to water is 1%, making the GPC comparable to a calibrated ionization chamber. This research has received financial support from Sun Nuclear Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of further calibration factors to be applied. The final accuracy of implantable MOSFETs when used for such kind of treatments was estimated to be within {+-}4%. Additional investigations using dose/fraction higher than 12 Gy, different beam configurations, and tracking systems could extend the present findings to other kind of treatments. MOSFET technology was proven to have high versatility in fast adaptation of existing detectors to new applications. It is plausible to expect a general feasibility of implantable MOSFET technology for in vivo dosimetry of the extracranial-targets treatments using the Cyberknife, provided each particular application will be validated by suitable both physical and clinical studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Million Person Study Innovation: Evaluating Cognitive Impairment and other Morbidity Outcomes from Chronic Radiation Exposure Through Linkages with the Centers for Medicaid and Medicare Services Assessment and Claims Data

Here, the study of One Million U.S. Radiation Workers and Veterans, the Million Person Study (MPS), examines the health consequences, both cancer and non-cancer, of exposure to ionizing radiation received gradually over time. Recently the MPS has focused on mortality patterns from neurological and behavioral conditions, e.g., Parkinson's disease, Alzheimer's disease, dementia, and motor neuron disease such as amyotrophic lateral sclerosis. A fuller picture of radiation-related late effects comes from studying both mortality and the occurrence (incidence) of conditions not leading to death. Accordingly, the MPS is identifying neurocognitive diagnoses from fee-for-service insurance claims from the Centers for Medicare and Medicaid Services (CMS), among Medicare beneficiaries beginning in 1999 (the earliest date claims data are available). Linkages to date have identified ∼540,000 workers with available health information. Such linkages provide individual information on important co-factor and confounding variables such as smoking, alcohol consumption, blood pressure, obesity, diabetes and many other health and demographic characteristics. The total person-level set of time-dependent variables, outcomes, organ-specific dose measures, co-factors, and demographics will be massive and much too large to be evaluated with standard software. Thus, development of specialized open-source software designed for large datasets (Colossus) is nearly complete. The wealth of information available from CMS claims data, coupled with individual dose reconstructions, will thus greatly enhance the quality and precision of health evaluations for this new field of low-dose radiation and neurocognitive effects.

Dauer, Lawrence T.↗

SU-E-T-118: Dose Verification for Accuboost Applicators Using TLD, Ion Chamber and Gafchromic Film Measurements

Purpose: To verify dose delivered with HDR Accuboost applicators using TLD, ion chamber and Gafchromic film measurements and to examine applicator leakage. Methods: A microSelectron HDR unit was used to deliver a dose of 50cGy to the mid-plane of a 62mm thick solid water phantom using dwell times from Monte Carlo pre-calculated nomograms for a 60mm, 70mm Round and 60mm Skin-Dose Optimized (SDO) applicators respectively. GafChromic EBT3+ film was embedded in the phantom midplane horizontally to measure dose distribution. Absolute dose was also measured with TLDs and an ADCL calibrated parallel-plate ion chamber placed in the film plane at field center for each applicator. The film was calibrated using 6MV x-ray beam. TLDs were calibrated in a Cs-137 source at UW-Madison calibration laboratory. Radiation leakage through the tungsten alloy shell was measured with a film wrapped around outside surface of a 60mm Round applicator. Results: Measured maximum doses at field center are consistently lower than predicated by 5.8% for TLD, 8.8% for ion chamber, and 2.6% for EBT3+ film on average, with measurement uncertainties of 2.2%, 0.3%, and 2.9% for TLD, chamber, film respectively. The total standard uncertainties for ion chamber and Gafchromic film measurement are 4.9% and 4.6% respectively[1]. The area defined by the applicator aperture was covered by 80% of maximum dose for 62mm compression thickness. When 100cGy is delivered to mid-plane with a 60mm Round applicator, surface dose ranges from 60cGy to a maximum of 145cGy, which occurs at source entrance to the applicator. Conclusion: Measured doses by all three techniques are consistently lower than predicted in our measurements. For a compression thickness of 62 mm, the field size defined by the applicator is only covered by 80% of prescribed dose. Radiation leakage of up to 145cGy was found at the source entrance of applicators.

07 ISOTOPE AND RADIATION SOURCES↗

NASA GeneLab Platform Utilized for Space Radiation Dosimetry Biological Response Compared to Radiation Ground Studies

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors factor that will impact health of astronauts on extended missions outside the protective effects of the Earth's magnetic field. Currently there are gaps in our knowledge of the health risks associated with chronic low dose, low dose rate ionizing radiation, specifically ions associated with high (H) atomic number (Z) and energy (E). The NASA GeneLab project (genelab.nasa.gov) aims to provide a detailed library of Omics datasets associated with biological samples exposed to HZE. The GeneLab Data System (GLDS) includes datasets from both spaceflight and ground-based studies, a majority of which involved exposure to ionizing radiation. Recently GeneLab has also assessed radiation dosimetry data with omics datasets associated with samples flown to the International Space Station (ISS). The combination of the detailed information on radiation exposure for ground-based studies and curated dosimetry information for spaceflight experiments allows GeneLab to be the first comprehensive Omics database for space related research from which an investigator can generate hypotheses to direct future experiments utilizing both ground and space biological radiation data. We demonstrate the usefulness of these datasets by analyzing multiple GeneLab datasets associated with both radiation ground-based studies and spaceflight studies. The radiation ground based studies we analyzed includes both in vivo and in vitro work with a range ions from protons to iron particles with doses from 0.1Gy to 2Gy. These datasets were compared to both in vivo and in vitro datasets from samples flown to the ISS and on shorter shuttle missions with total doses of 0.1 mGy to 30 mGys. From this analysis we were able to associate distinct biological signatures associating specific ions to specific biological response to radiation exposure in space. For example, we discovered radiation biological response related to cardiovascular effects from proton ground studies are the dominating response for samples related to cardiovascular effects on the ISS. With this work we will provide a summary of how different ions will impact different biological response in space and how this can be used in future studies to assess optimal ground experiments to simulate space radiation.

Beheshti, Afshin↗