Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Smart Planning for Radioactive Source Transport Advanced Tools for Increased Safety and Efficiency

End-of-life (EOL) management of high-activity radioactive sources is made uniquely challenging by the inherent risks associated with storage and transportation of these sources, the complex logistics involved, and the strict requirements for regulatory compliance. Traditional methods lack comprehensive tools for accurate site assessments and precision planning for the transportation of radioactive sources. They also frequently fail to provide the adaptability required to consider diverse operational environments, resulting in inefficiencies and potential safety concerns. This paper introduces a novel software solution developed to address these issues by integrating advanced technologies such as light detection and ranging (LiDAR)-based 3D environment modeling, smart dynamic route planning, and customizable measurement functionalities. This software enables detailed terrain visualizations, facilitating thorough environmental assessments and enabling users to virtually navigate, analyze, and plan site-specific operations. Among the key features are a user-centric interface for virtual navigation, precise site measurement tools for site evaluations, interactive visualizations that highlight potential operational hazards, dynamic route planning capabilities, and real-time collision detection to promote safe workflows. By demonstrating the effectiveness of this tool through real-world application, the present work underscores the tool’s potential to revolutionize radioactive source EOL management by improving operational efficiencies, minimizing risk, and advancing the state of practice to achieve suitable and secure radioactive material handling.

99 - GENERAL AND MISCELLANEOUS↗

Statistical tools for a better optical model

Background: Modern statistical tools provide the ability to compare the information content of observables and provide a path to explore which experiments would be most useful to give insight into and constrain theoretical models. Purpose: Here we study three such tools in the context of nuclear reactions with the goal of constraining the optical potential. Method: The three statistical tools examined are (i) the principal component analysis, (ii) the sensitivity analysis based on derivatives, and (iii) the Bayesian evidence. We first apply these tools to a toy-model case, comparing the form of the imaginary part of the optical potential. Then we consider two different reaction observables, elastic angular distributions and polarization data for reactions on 48 Ca and 208 Pb at two different beam energies. Results: For the toy-model case, we find significant discrimination power in the sensitivities and the Bayesian evidence, showing clearly that the volume imaginary term is more useful to describe scattering at higher energies. When comparing between elastic cross sections and polarization data using realistic optical models, sensitivity studies indicate that both observables are roughly equally sensitive but the variability of the optical model parameters is strongly angle dependent. The Bayesian evidence shows some variability between the two observables, but the Bayes factor obtained is not sufficient to discriminate between angular distributions and polarization. Conclusions: From the cases considered, we conclude that, in general, elastic scattering angular distributions have similar impact in constraining the optical potential parameters compared with the polarization data. The angular ranges for the optimum experimental constraints can vary significantly with the observable considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New tools for the analysis and validation of cryo-EM maps and atomic models

Recent advances in the field of electron cryomicroscopy (cryo-EM) have resulted in a rapidly increasing number of atomic models of biomacromolecules that have been solved using this technique and deposited in the Protein Data Bank and the Electron Microscopy Data Bank. Similar to macromolecular crystallography, validation tools for these models and maps are required. While some of these validation tools may be borrowed from crystallography, new methods specifically designed for cryo-EM validation are required. Here, new computational methods and tools implemented in PHENIX are discussed, including d 99 to estimate resolution, phenix.auto_sharpen to improve maps and phenix.mtriage to analyze cryo-EM maps. It is suggested that cryo-EM half-maps and masks should be deposited to facilitate the evaluation and validation of cryo-EM-derived atomic models and maps. The application of these tools to deposited cryo-EM atomic models and maps is also presented.

59 BASIC BIOLOGICAL SCIENCES↗

Open Source Synergy: Developing and Validating PMU Data Analysis Techniques Using Open Source Tools and Datasets

This paper presents an exploration into the development and validation of data analysis approaches for Phasor Measurement Units (PMUs) using open-source datasets and tools. Various methods for event detection, event classification, frequency response, and oscillation analysis were tested. We leverage the capabilities of Archive Walker (AW), the Frequency Response Analysis Tool (FRAT), and the Oscillation Baselining and Analysis Tool (OBAT), all open-source tools, for efficient processing and analysis of synchrophasor data. The open-source Transmission Signature Library (TSL) dataset was employed as a dataset for a comprehensive evaluation to assess the performance and reliability of the proposed methods.

PMU, event analysis, oscillation, Frequency Respon↗

Tools for Understanding Identity

Identity attribution and enrichment is critical to many aspects of law-enforcement and intelligence gathering; this identity typically spans a number of domains in the natural-world such as biographic information (factual information – e.g. names, addresses), biometric information (e.g. fingerprints) and psychological information. In addition to these natural-world projections of identity, identity elements are projected in the cyber-world. Conversely, undesirable elements may use similar techniques to target individuals for spear-phishing attacks (or worse), and potential targets or their organizations may want to determine how to minimize the attack surface exposed. Our research has been exploring the construction of a mathematical model for identity that supports such holistic identities. The model captures the ways in which an identity is constructed through a combination of data elements (e.g. a username on a forum, an address, a telephone number). Some of these elements may allow new characteristics to be inferred, hence enriching the holistic view of the identity. An example use-case would be the inference of real names from usernames, the ‘path’ created by inferring new elements of identity is highlighted in the ‘critical information’ panel. Individual attribution exercises can be understood as paths through a number of elements. Intuitively the entire realizable ‘capability’ can be modeled as a directed graph, where the elements are nodes and the inferences are represented by links connecting one or more antecedents with a conclusion. The model can be operationalized with two levels of tool support described in this paper, the first is a working prototype, the second is expected to reach prototype by July 2013: Understanding the Model The tool allows a user to easily determine, given a particular set of inferences and attributes, which elements or inferences are of most value to an investigator (or an attacker). The tool is also able to take into account the difficulty of the inferences, allowing the user to consider different scenarios depending on the perceived resources of the attacker, or to prioritize lines of investigation. It also has a number of interesting visualizations that are designed to aid the user in understanding the model. The tool works by considering the inferences as a graph and runs various graph-theoretic algorithms, with some novel adaptations, in order to deduce various properties. Using the Model To help investigators exploit the model to perform identity attribution, we have developed the Identity Map visualization. For a user-provided set of known starting elements and a set of desired target elements for a given identity, the Identity Map generates investigative workflows as paths through the model. Each path consists of a series of elements and inferences between them that connect the input and output elements. Each path also has an associated confidence level that estimates the reliability of the resulting attribution. Identity Map can help investigators understand the possible ways to make an identification decision and guide them toward the data-collection or analysis steps required to reach that decision.

Creese, Sadie↗

Cumulative Spatial Impact Layers: A Novel Multivariate Spatio-Temporal Analytical Summarization Tool

Scientific inquiry often requires analysis of multiple spatio-temporal datasets, ranging in type and size, using complex multi-step processes demanding an understanding of GIS theory and software. Cumulative Spatial Impact Layers (CSIL) is a GIS-based tool that summarizes spatio-temporal datasets based on overlapping features and attributes. Leveraging a recursive quadtree method, and applying multiple additive frameworks, the CSIL tool allows users to analyze raster and vector datasets by calculating data, record, or attribute density. Providing an efficient and robust method for summarizing disparate, multi-format, multi-source geospatial data, CSIL addresses the need for a new integration approach and resulting geospatial product. The built-in flexibility of the CSIL tool allows users to answer a range of spatially-driven questions. Example applications are provided in this paper to illustrate the versatility and variety of uses for this CSIL tool and method. Use cases include addressing regulatory decision-making needs, economic modeling, and resource management. Performance reviews for each use case are also presented, demonstrating how CSILs provides a more efficient and robust approach to assess a range of multivariate spatial data for a variety of uses.

58 GEOSCIENCES↗

Evaluating the Potential for Remote In-Process Monitoring of Tool Wear in Friction Stir Welding of Stainless Steel

A wear characterization study was performed to determine the useful lifetime of Polycrystalline Cubic Boron Nitride tooling for the friction stir welding (FSW) of stainless steel samples in support of a nuclear repair welding research and development program. In-situ and ex-situ laser profilometry were utilized as primary methods of monitoring tool geometry degradation, and volumetric defects were detected through both non-destructive and destructive techniques, as repeated welds of a standard sample configuration were produced. The spectral content of weld forces were examined to search for indications of evolving material flow conditions, caused by significant tool wear, that would result in the formation of defects, and an artificial neural network was trained and evaluated as a means of automatically detecting these conditions. Here, the resulting performance constituted a successful demonstration of in-process monitoring of tool wear and weld quality in FSW of a high melting temperature, high hardness material.

36 MATERIALS SCIENCE↗

Westinghouse waste simulation and optimization software tool

Applications for dynamic simulation can be found in virtually all areas of process engineering. The tangible benefits of using dynamic simulation can be seen in tighter design, smoother start-ups and optimized operation. Thus, proper implementation of dynamic simulation can deliver substantial benefits. These benefits are typically derived from improved process understanding. Simulation gives confidence in evidence based decisions and enables users to try out lots of 'what if' scenarios until one is sure that a decision is the right one. In radioactive waste treatment tasks different kinds of waste with different volumes and properties have to be treated, e.g. from NPP operation or D and D activities. Finding a commercially and technically optimized waste treatment concept is a time consuming and difficult task. The Westinghouse Waste Simulation and Optimization Software Tool will enable the user to quickly generate reliable simulation models of various process applications based on equipment modules. These modules can be built with ease and be integrated into the simulation model. This capability ensures that this tool is applicable to typical waste treatment tasks. The identified waste streams and the selected treatment methods are the basis of the simulation and optimization software. After implementing suitable equipment data into the model, process requirements and waste treatment data are fed into the simulation to finally generate primary simulation results. A sensitivity analysis of automated optimization features of the software generates the lowest possible lifecycle cost for the simulated waste stream. In combination with proven waste management equipments and integrated waste management solutions, this tool provides reliable qualitative results that lead to an effective planning and minimizes the total project planning risk of any waste management activity. It is thus the ideal tool for designing a waste treatment facility in an optimum manner, taking account of the detailed waste stream and specific requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems

The medical linear accelerator (linac) integrated with a kilovoltage (kV) flat-panel imager has been emerging as an important piece of equipment for image-guided radiation therapy. Due to the sagging of the linac head and the flexing of the robotic arms that mount the x-ray tube and flat-panel detector, geometric nonidealities generally exist in the imaging geometry no matter whether it is for the two-dimensional projection image or three-dimensional cone-beam computed tomography. Normally, the geometric parameters are established during the commissioning and incorporated in correction software in respective image formation or reconstruction. A prudent use of an on-board imaging system necessitates a routine surveillance of the geometric accuracy of the system like the position of the x-ray source, imager position and orientation, isocenter, rotation trajectory, and source-to-imager distance. Here we describe a purposely built phantom and a data analysis software for monitoring these important parameters of the system in an efficient and automated way. The developed tool works equally well for the megavoltage (MV) electronic portal imaging device and hence allows us to measure the coincidence of the isocenters of the MV and kV beams of the linac. This QA tool can detect an angular uncertainty of 0.1 deg. of the x-ray source. For spatial uncertainties, such as the source position, the imager position, or the kV/MV isocenter misalignment, the demonstrated accuracy of this tool was better than 1.6 mm. The developed tool provides us with a simple, robust, and objective way to probe and monitor the geometric status of an imaging system in a fully automatic process and facilitate routine QA workflow in a clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool

Purpose: The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order to extend such an approach to intensity-modulated arc therapy (IMAT), the combined use of an EPID system and a portal dose image prediction (PDIP) tool has been investigated. Methods: The dosimetric behavior of an EPID system, mechanically reinforced to maintain its positional stability during the accelerator gantry rotation, has been studied to assess its ability to measure portal dose distributions for IMAT treatment beams. In addition, the PDIP tool of a commercial treatment planning system, commonly used for static IMRT dosimetry, has been validated for simulating the PDIs of IMAT treatment fields. The method has been applied to the delivery verification of 23 treatment fields that were measured in their dual mode of IMRT and IMAT modalities. Results: The EPID system has proved to be appropriate for measuring the PDIs of IMAT fields; additionally the PDIP tool was able to simulate these accurately. The results are quite similar to those obtained for static IMRT treatment verification, although it was necessary to investigate the dependence of the EPID signal and of the accelerator monitor chamber response on variable dose rate. Conclusions: Our initial tests indicate that the EPID system, together with the PDIP tool, is a suitable device for the verification of IMAT plan delivery; however, additional tests are necessary to confirm these results.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-442: Sensitivity of Quality Assurance Tools to Delivery Errors On a Magnetic Resonance-Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the sensitivity of the quality assurance (QA) tools actively used on a clinical MR-IGRT system for potential delivery errors. Methods: Patient-specific QA procedures have been implemented for a commercially available Cobalt-60 MR-IGRT system. The QA tools utilized were a MR-compatible cylindrical diode-array detector (ArcCHECK) with a custom insert which positions an ionization chamber (Exradin A18) in the middle of the device, as well as an in-house treatment delivery verification program. These tools were tested to investigate their sensitivity to delivery errors. For the ArcCHECK and ion chamber, a baseline was established with a static field irradiation to a known dose. Variations of the baseline were investigated which included rotated gantry, altered field size, directional shifts, and different delivery time. In addition, similar variations were tested with the automated delivery verification program that compared the treatment parameters in the machine delivery logs to the ones in the plan. To test the software, a 3-field conformal plan was generated as the baseline. Results: ArcCHECK noted at least a 13% decrease in passing rate from baseline in the following scenarios: gantry rotation of 1 degree from plan, 5mm change in field size, 2mm lateral shift, and delivery time decrease. Ion chamber measurements remained consistent for these variations except for the 5 second decrease in delivery time scenario which resulted in an 8% difference from baseline. The delivery verification software was able to detect and report the simulated errors such as when the gantry was rotated by 0.6 degrees, the beam weighting was changed by a percent, a single multileaf collimator was moved by 1cm, and the dose was changed from 2 to 1.8Gy. Conclusion: The results show that the current tools used for patient specific QA are capable of detecting small errors in RT delivery with presence of magnetic field.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-04: Development of a Secondary MU Calculation Tool for An Integrated MR-LINAC

Purpose: To develop a fast secondary MU calculation tool for an integrated MR-Linac, an emerging technology for delivering image-guided on-line adaptive therapy. Methods: A software tool was developed to implement a modified Clarkson integration algorithm for point-dose calculation, considering the dosimtric effect of a magnetic field. A research planning system, considering the presence of a perpendicular 1.5 T magnetic field, was used to extract the beam data (e.g., depth doses and beam profiles) required for the MU calculation in homogeneous phantom of 60×60×40 cm3 for a prototype of MR-Linac integrating a 1.5 T MR scanner with 6MV photon beams. These dosimetric data may be replaced with those to be collected during the commissioning measurement of the MR-Linac. Results: The presence of the magnetic field resulted in noticeable changes including (1) shifts in beam profiles for small fields (< 2×2 cm2), and (2) changes in central-axis doses when one of field edges is < 2 cm away from the central axis. For example, the maximum change in central-axis dose was up to 8% for one of the field borders with a distance away from the central axis of <1 cm. These changes are relevant for the MU calculation particularly for IMRT and VMAT, where most of segments are small. These magnetic field affected beam profiles and depth doses were included in the software tool. The MU calculations from the software tool for selective representative plans were found to agree with those from the research planning system within 10%. Conclusion: The presence of a perpendicular magnetic field results in noticeable changes in beam profiles and depth doses for small fields. These changes are included in the secondary MU calc{sup 33}u{sup 3}lation to be used as a redundancy check for an integrated MR-Linac.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Automated Imaging QA for TG-142 with RIT Presentation Time: 2:45 – 3:15 PM This presentation will discuss software tools for automated imaging QA and phantom analysis for TG-142. All modalities used in radiation oncology will be discussed, including CBCT, planar kV imaging, planar MV imaging, and imaging and treatment coordinate coincidence. Vendor supplied phantoms as well as a variety of third-party phantoms will be shown, along with appropriate analyses, proper phantom setup procedures and scanning settings, and a discussion of image quality metrics. Tools for process automation will be discussed which include: RIT Cognition (machine learning for phantom image identification), RIT Cerberus (automated file system monitoring and searching), and RunQueueC (batch processing of multiple images). In addition to phantom analysis, tools for statistical tracking, trending, and reporting will be discussed. This discussion will include an introduction to statistical process control, a valuable tool in analyzing data and determining appropriate tolerances. An Introduction to TG-142 Imaging QA Using Standard Imaging Products Presentation Time: 3:15 – 3:45 PM Medical Physicists want to understand the logic behind TG-142 Imaging QA. What is often missing is a firm understanding of the connections between the EPID and OBI phantom imaging, the software “algorithms” that calculate the QA metrics, the establishment of baselines, and the analysis and interpretation of the results. The goal of our brief presentation will be to establish and solidify these connections. Our talk will be motivated by the Standard Imaging, Inc. phantom and software solutions. We will present and explain each of the image quality metrics in TG-142 in terms of the theory, mathematics, and algorithms used to implement them in the Standard Imaging PIPSpro software. In the process, we will identify the regions of phantom images that are analyzed by each algorithm. We then will discuss the process of the creation of baselines and typical ranges of acceptable values for each imaging quality metric.

07 ISOTOPE AND RADIATION SOURCES↗

TU-C-BRE-02: A Novel, Highly Efficient and Automated Quality Assurance Tool for Modern Linear Accelerators

Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. Varian’s Machine Performance Check (MPC) uses IsoCal phantom to test geometric and dosimetric aspects of the TrueBeam systems in <5min. In this study we independently tested the accuracy and robustness of the MPC tools. Methods: MPC is automated for simultaneous image-acquisition, using kV-and-MV onboard-imagers (EPIDs), while delivering kV-and-MV beams in a set routine of varying gantry, collimator and couch angles. MPC software-tools analyze the images to test: i) beam-output and uniformity, ii) positional accuracy of isocenter, EPIDs, collimating jaws (CJs), MLC leaves and couch and iii) rotational accuracy of gantry, collimator and couch. 6MV-beam dose-output and uniformity were tested using ionization-chamber (IC) and ICarray. Winston-Lutz-Tests (WLT) were performed to measure isocenter-offsets caused by gantry, collimator and couch rotations. Positional accuracy of EPIDs was evaluated using radio-opaque markers of the IsoCal phantom. Furthermore, to test the robustness of the MPC tools we purposefully miscalibrated a non-clinical TrueBeam by introducing errors in beam-output, energy, symmetry, gantry angle, couch translations, CJs and MLC leaves positions. Results: 6MV-output and uniformity were within ±0.6% for most measurements with a maximum deviation of ±1.0%. Average isocenter-offset caused by gantry and collimator rotations was 0.316±0.011mm agreeing with IsoLock (0.274mm) and WLT (0.41mm). Average rotation-induced couch-shift from MPC was 0.378±0.032mm agreeing with WLT (0.35mm). MV-and-kV imager-offsets measured by MPC were within ±0.15mm. MPC predicted all machine miscalibrations within acceptable clinical tolerance. MPC detected the output miscalibrations within ±0.61% while the MLC and couch positions were within ±0.06mm and ±0.14mm, respectively. Gantry angle miscalibrations were detected within ±0.1°. Conclusions: MPC is a useful tool for QA of TrueBeam systems and its automation makes it highly efficient for testing both geometric and dosimetric aspects of the machine. This is very important for hypo-fractionated SBRT treatments. Received support from Varian Medical Systems, Palo Alto, CA 94304-1038.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-253: Development of a GDPM Monte Carlo Based Quality Assurance Tool for Cyberknife

Purpose: To develop a 3D quality assurance (QA) tool for Cyberknife plans using a GPU-based Monte Carlo dose calculation package, gDPM. The developed QA tool will be used as a secondary check for Cyberknife treatment planning software (TPS) reported dose distributions. Methods: Phase space files of the 5, 7.5, 10, 15, and 60 mm iris cones were downloaded from IAEA phase-space database. From the 60mm iris cone phase space file, we were able to generate raw phase space files for all other cones using a particle rejection method. The particles in the raw phase space files were binned with respect to the radial position and energy for commissioning. During the commissioning process, gDPM calculated percent depth dose and off-center ratios which were compared to those measured in the Blue Phantom. The off-axis data was measured with an SAD setup at depths of 15, 50, 100, 200, and 300 mm. At the commissioning stage, an optimization problem was solved to adjust the binned particles weights to minimize the difference between the calculated and measured ones. Commissioning validations will be performed by measuring point dose data of patient specific plans delivered to water phantoms. With commissioned phase space files, 3D patient-specific dose distributions will be calculated and compared against TPS reported dose. Results: Beyond the initial buildup region, the root mean square difference between the calculated and measured percent depth dose differences was less than 0.5%. The full-width half-max data from the off-axis ratio calculations was found to be within 0.1 mm of the measured data. Conclusion: Our current work showed excellent agreement between the gDPM calculated dose and the measured data for all cone sizes and types for the Cyberknife system. Implementation of a fast and accurate QA tool for patient specific plans will be feasible with this tool.

60 APPLIED LIFE SCIENCES↗

SU-E-T-254: Development of a HDR-BT QA Tool for Verification of Source Position with Oncentra Applicator Modeling

Purpose: To develop a High Dose Rate Brachytherapy (HDR-BT) quality assurance (QA) tool for verification of source position with Oncentra applicator modeling, and to report the results of radiation source positions with this tool. Methods: We developed a HDR-BT QA phantom and automated analysis software for verification of source position with Oncentra applicator modeling for the Fletcher applicator used in the MicroSelectron HDR system. This tool is intended for end-to-end tests that mimic the clinical 3D image-guided brachytherapy (3D-IGBT) workflow. The phantom is a 30x30x3 cm cuboid phantom with radiopaque markers, which are inserted into the phantom to evaluate applicator tips and reference source positions; positions are laterally shifted 10 mm from the applicator axis. The markers are lead-based and scatter radiation to expose the films. Gafchromic RTQA2 films are placed on the applicators. The phantom includes spaces to embed the applicators. The source position is determined as the distance between the exposed source position and center position of two pairs of the first radiopaque markers. We generated a 3D-IGBT plan with applicator modeling. The first source position was 6 mm from the applicator tips, and the second source position was 10 mm from the first source position. Results: All source positions were consistent with the exposed positions within 1 mm for all Fletcher applicators using in-house software. Moreover, the distance between source positions was in good agreement with the reference distance. Applicator offset, determined as the distance from the applicator tips at the first source position in the treatment planning system, was accurate. Conclusion: Source position accuracy of applicator modeling used in 3D-IGBT was acceptable. This phantom and software will be useful as a HDR-BT QA tool for verification of source position with Oncentra applicator modeling.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-12: End-User Oriented Tools and Procedures for Testing Brachytherapy TPSs Employing MBDCAs

Purpose: To develop user-oriented tools for commissioning and dosimetry testing of {sup 192}Ir brachytherapy treatment planning systems (TPSs) employing model based dose calculation algorithms (MBDCAs). Methods: A software tool (BrachyGuide) has been developed for the automatic generation of MCNP6 input files from any CT based plan exported in DICOM RT format from Elekta and Varian TPSs. BrachyGuide also facilitates the evaluation of imported Monte Carlo (MC) and TPS dose distributions in terms of % dose differences and gamma index (CT overlaid colormaps or relative frequency plots) as well as DVHs and related indices. For users not equipped to perform MC, a set of computational models was prepared in DICOM format, accompanied by treatment plans and corresponding MCNP6 generated reference data. BrachyGuide can then be used to compare institutional and reference data as per TG186. The model set includes a water sphere with the MBDCA WG {sup 192}Ir source placed centrically and in two eccentric positions, a water sphere with cubic bone and lung inhomogeneities and a five source dwells plan, and a patient equivalent model with an Accelerated Partial Breast Irradiation (APBI) plan. Results: The tools developed were used for the dosimetry testing of the Acuros and ACE MBDCAs implemented in BrachyVision v.13 and Oncentra Brachy v.4.5, respectively. Findings were consistent with previous results in the literature. Besides points close to the source dwells, Acuros was found to agree within type A uncertainties with the reference MC results. Differences greater than MC type A uncertainty were observed for ACE at distances >5cm from the source dwells and in bone. Conclusion: The tools developed are efficient for brachytherapy MBDCA planning commissioning and testing. Since they are appropriate for distribution over the web, they will be put at the AAPM WG MBDCA’s disposal. Research co-financed by the ESF and Greek funds. NSRF operational Program: Education and Lifelong Learning Investing in Knowledge Society-Aristeia. Varian Medical Systems and Nucletron, an Elekta company provided access to TPSs for research purposes. Miss Peppa was supported by IKY-fellowships of excellence for postgraduate studies in Greece,Siemens Program.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-03: TOPAS-edu: A Window Into the Stochastic World Through the TOPAS Tool for Particle Simulation

Purpose: The stochastic nature of the subatomic world presents a challenge for physics education. Even experienced physicists can be amazed at the varied behavior of electrons, x-rays, protons, neutrons, ions and the any short-lived particles that make up the overall behavior of our accelerators, brachytherapy sources and medical imaging systems. The all-particle Monte Carlo particle transport tool, TOPAS Tool for Particle Simulation, originally developed for proton therapy research, has been repurposed into a physics teaching tool, TOPAS-edu. Methods: TOPAS-edu students set up simulated particle sources, collimators, scatterers, imagers and scoring setups by writing simple ASCII files (in the TOPAS Parameter Control System format). Students visualize geometry setups and particle trajectories in a variety of modes from OpenGL graphics to VRML 3D viewers to gif and PostScript image files. Results written to simple comma separated values files are imported by the student into their preferred data analysis tool. Students can vary random seeds or adjust parameters of physics processes to better understand the stochastic nature of subatomic physics. Results: TOPAS-edu has been successfully deployed as the centerpiece of a physics course for master’s students at Queen’s University Belfast. Tutorials developed there takes students through a step by step course on the basics of particle transport and interaction, scattering, Bremsstrahlung, etc. At each step in the course, students build simulated experimental setups and then analyze the simulated results. Lessons build one upon another so that a student might end up with a full simulation of a medical accelerator, a water-phantom or an imager. Conclusion: TOPAS-edu was well received by students. A second application of TOPAS-edu is currently in development at Zurich University of Applied Sciences, Switzerland. It is our eventual goal to make TOPAS-edu available free of charge to any non-profit organization, along with associated tutorial materials developed by the TOPAS-edu community. Work supported in part by the U.S. Department of Energy under contract number DE-AC02-76SF00515. B. Villagomez-Bernabe is supported by CONACyT (Mexican Council for Science and Technology) project 231844.

60 APPLIED LIFE SCIENCES↗