Product Consistency Test Results for the LAW Phase 5 Glasses
This report provides the results of the Vapor Hydration Test solutions and the Product Consistency Test leachates from the Low-Activity Waste Phase 5 glasses, a series of simulated nuclear waste glasses fabricated at the Pacific Northwest National Laboratory. The series included quenched and canister-centerline cooled versions of the glasses. These data will be used in the development of enhanced property/composition models for waste glass vitrification at Hanford. Several of the blanks had detectable amounts of sodium and/or silicon. The measured concentrations (mg/L) of boron, sodium, and silicon for the low-activity test reference material glass included with the Product Consistency Tests were much lower than the expected low-activity test reference material test results. A review of the Product Consistency Test data indicated that there was generally little difference between the normalized values based on targeted or measured glass composition. Heat treatment had various impacts on the normalized concentration values. Most of the glasses had NC B , NC Na , and NC Si values that were greater than the Hanford Tank Waste Treatment and Immobilization Plant low-activity waste constraint of 4 g/L. The release rates for boron, sodium, and silicon were highly correlated for the study glasses.