Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Fixture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

FY2023 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Limited-constraint WAAM fixture for hybrid manufacturing

This paper describes a limited-constraint alternative to the traditional over-constrained build plate clamping in metal additive manufacturing. A fixture design is presented that enables build plate thermal growth within its plane while restricting deformation perpendicular to that plane. A prototype fixture is designed, fabricated, and tested for wire arc additive manufacturing (WAAM). Experimental results are presented for depositing 1.2 mm diameter 5356 aluminum wire on a 5052 aluminum build plate. The build plate deformation is measured for various clamping torques and a 77.3% reduction in distortion is achieved using the limited-constraint approach with identical WAAM parameters.

36 MATERIALS SCIENCE↗

An experimental investigation of delamination buckling and growth

An experimental investigation of delamination buckling and growth in compression loaded composite laminates is described. Compression tests were conducted on impact damaged laminates and laminates containing preimplanted delaminations. These tests were performed utilizing a fixture designed to prevent global buckling. The results of this study indicate that considerations in addition to initial defect geometry influence the shape of the boundary of the buckled region. Further, idealized delamination buckling from preimplanted delaminations may occur quite differently than in the case of an impact damaged laminate. The growth of a delamination following buckling may follow an irregular path and may involve the delamination growing into different interfaces.

Davidson, Barry D.↗

Analysis, design, and experimental results for lightweight space heat receiver canisters, phase 1

Critical technology experiments have been performed on thermal energy storage modules in support of the Brayton Advanced Heat Receiver program. The modules are wedge-shaped canisters designed to minimize the mechanical stresses that occur during the phase change of the lithium fluoride phase change material. Nickel foam inserts were used in some of the canisters to provide thermal conductivity enhancement and to distribute the void volume. Two canisters, one with a nickel foam insert, and one without, were thermally cycled in various orientations in a fluidized bed furnace. The only measurable impact of the nickel foam was seen when the back and short sides of the canister were insulated to simulate operation in the advanced receiver design. In tests with insulation, the furnace to back side delta T was larger in the canister with the nickel foam insert, probably due to the radiant absorptivity of the nickel. However, the differences in the temperature profiles of the two canisters were small, and in many cases the profiles matched fairly well. Computed Tomography (CT) was successfully used to nondestructively demarcate void locations in the canisters. Finally, canister dimensional stability, which was measured throughout the thermal cycling test program with an inspection fixture was satisfactory with a maximum change of 0.635 mm (0.025 in.).

Schneider, Michael G.↗

Addressing Challenges to the Design & Test of Operational Lighting Environments for the International Space Station

In our day to day lives, the availability of light, with which to see our environment, is often taken for granted. The designers of land based lighting systems use sunlight and artificial light as their toolset. The availability of power, quantity of light sources, and variety of design options are often unlimited. The accessibility of most land based lighting systems makes it easy for the architect and engineer to verify and validate their design ideas. Failures with an implementation, while sometimes costly, can easily be addressed by renovation. Consider now, an architectural facility orbiting in space, 260 miles above the surface of the earth. This human rated architectural facility, the International Space Station (ISS) must maintain operations every day, including life support and appropriate human comforts without fail. The facility must also handle logistics of regular shipments of cargo, including new passengers. The ISS requires accommodations necessary for human control of machine systems. Additionally, the ISS is a research facility and supports investigations performed inside and outside its livable volume. Finally, the facility must support remote operations and observations by ground controllers. All of these architectural needs require a functional, safe, and even an aesthetic lighting environment. At Johnson Space Center, our Habitability and Human Factors team assists our diverse customers with their lighting environment challenges, via physical test and computer based analysis. Because of the complexity of ISS operational environment, our team has learned and developed processes that help ISS operate safely. Because of the dynamic exterior lighting environment, uses computational modeling to predict the lighting environment. The ISS' orbit exposes it to a sunrise every 90 minutes, causing work surfaces to quickly change from direct sunlight to earthshine to total darkness. Proper planning of vehicle approaches, robotics operations, and crewed Extra Vehicular Activities are mandatory to ensure safety to the crew and all others involved. Innovation in testing techniques is important as well. The advent of Solid State Lighting technology and the lack of stable national and international standards for its implementation pose new challenges on how to design, test and verify individual light fixtures and the environment that uses them. The ISS will soon be replacing its internal fluorescent lighting system to a solid state LED system. The Solid State Lighting Assembly will be used not only for general lighting, but also as a medical countermeasure to control the circadian rhythm of the crew. The new light source has performance criteria very specific to its spectral fingerprint, creating new challenges that were originally not as significant during the original design of the ISS. This presentation will showcase findings and toolsets our team is using to assist in the planning of tasks, and design of operational lighting environments on the International Space Station.

Clark, Toni A.↗

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Spacecraft thermal margins depend on the temperature penalty of installed interfaces, yet catalog conductivity omits bondline thickness, mating surfaces, preload, and environment. The Testbed for Advanced Interface Materials in Vacuum (TAIMV) addresses this engineering-data gap by converting ambient/vacuum temperature fields from a four-coupon stack into quantities usable in spacecraft thermal models. Its 17-node steady-state model resolves axial conduction, parasitic fixture paths, grease-filled contact, radiation, and ambient convection. Four monolithic checks gave axial heat-rate ratios of 0.90–1.02, and Braycote calibration self-recovery gave 2.20% casewise mean absolute percentage error (MAPE) and 2.85% maximum difference. With transferable fixture terms frozen, Krytox LVP tested cross-material transfer against a manufacturer-derived external relation. The six Krytox cases gave 2.28% MAPE, 5.10% maximum difference, and full-field residual root-mean-square values of 0.553 °C ambient and 1.306 °C vacuum. Installed-joint resistance spanned 6.39–7.15 × 10⁻⁴ m²·K/W for Braycote and 4.09–4.49 × 10⁻⁴ m²·K/W for Krytox, corresponding to 2.33–6.66 K per modeled interface over the tested heat-flux range. TAIMV therefore supplies directly usable installed-joint resistance and conductance, plus apparent installed conductivity and explicitly model-conditioned grease conductivity/contact terms.

heat transfer↗

Effects of stitching on fracture toughness of uniweave textile graphite/epoxy laminates

The effects of through-the-thickness stitching on impact damage resistance, impact damage tolerance, and Mode 1 and Mode 2 fracture toughness of textile graphite/epoxy laminates were studied experimentally. Graphite/epoxy laminates were fabricated from AS4 graphite uniweave textiles and 3501-6 epoxy using Resin Transfer Molding. The cloths were stitched with Kevlar(tm) and glass yarns before resin infusion. Delamination was implanted during processing to simulate impact damage. Sublaminate buckling tests were performed in a novel fixture to measure Compression After Impact (CAI) strength of stitched laminates. The results show that CAI strength can be improved up to 400% by through-the-thickness stitching. Double Cantilever Beam tests were performed to study the effect of stitching on Mode 1 fracture toughness G(sub 1c). It was found that G(sub 1c) increased 30 times for a low stitching density of 16 stitches/sq in. Mode 2 fracture toughness was measured by testing the stitched beams in End Notch Flexure tests. Unlike in the unstitiched beams, crack propagation in the stitched beams was steady. The current formulas for ENF tests were not found suitable for determining G(sub 2C) for stitched beams. Hence two new methods were developed - one based on crack area measured from ultrasonic C-scanning and the other based on equivalent crack area measured from the residual stiffness of the specimen. The G(sub 2c) was found to be at least 5-15 times higher for the stitched laminates. The mechanisms by which stitching increases the CAI strength and fracture toughness are discussed.

Sankar, Bhavani V.↗

Experimental evaluation of tailored chordwise deformable box beam and correlation with theory

This paper describes an experimental methodology based upon the use of a flexible sling support and load application system that has been created and utilized to evaluate a box beam which incorporates an elastic tailoring technology. The design technique used here for elastically tailoring the composite box beam structure is to produce exaggerated chordwise camber deformation of substantial magnitude to be of practical use in the new composite aircraft wings. The traditional methods such as a four-point bend test to apply constant bending moment with rigid fixtures inhibits the designed chordwise deformation from occurring and, hence, the need for the new test method. The experimental results for global camber and spanwise bending compliances correlate well with theoretical predictions based on a beam-like model.

Rehfield, Lawrence W.↗

An Experimental and Analytical Evaluation of a Biaxial Test for Determining Shear Properties of Composite Materials

The results of an experimental and analytical investigation of a biaxial tension/compression test for determining shear properties of composite materials are reported. Using finite element models of isotropic and orthotropic laminates, a specimen geometry was optimized. A kinematic fixture was designed to introduce an equal and opposite pair of forces into a specimen with a one inch square test section. Aluminum and several composite laminates with the optimized geometry and a configuration with large stress gradients were tested in the fixture. The specimens were instrumented with strain gages in the center of the test section for shear stiffness measurements. Pure shear strain was measured. The results from the experiments correlated well with finite element results. Failure of the specimens occurred through the center of the test section and appeared to have initiated at the high stress points. The results lead to the conclusion that the optimized specimen is suitable for determining shear modulus for composite materials. Further revisions to the specimen geometry are necessary if the method is to give shear strength data.

Kennedy, John M.↗

Investigation of Gearbox Vibration Transmission Paths on Gear Condition Indicator Performance

Helicopter health monitoring systems use vibration signatures generated from damaged components to identify transmission faults. For damaged gears, these signatures relate to changes in dynamics due to the meshing of the damaged tooth. These signatures, referred to as condition indicators (CI), can perform differently when measured on different systems, such as a component test rig, or a full-scale transmission test stand, or an aircraft. These differences can result from dissimilarities in systems design and environment under dynamic operating conditions. The static structure can also filter the response between the vibration source and the accelerometer, when the accelerometer is installed on the housing. To assess the utility of static vibration transfer paths for predicting gear CI performance, measurements were taken on the NASA Glenn Spiral Bevel Gear Fatigue Test Rig. The vibration measurements were taken to determine the effect of torque, accelerometer location and gearbox design on accelerometer response. Measurements were taken at the housing and compared while impacting the gear set near mesh. These impacts were made at gear mesh to simulate gear meshing dynamics. Data measured on a helicopter gearbox installed in a static fixture were also compared to the test rig. The behavior of the structure under static conditions was also compared to CI values calculated under dynamic conditions. Results indicate that static vibration transfer path measurements can provide some insight into spiral bevel gear CI performance by identifying structural characteristics unique to each system that can affect specific CI response.

Dempsey, Paula J.↗

Compression-after-impact testing of thin composite materials

A new method has been devised to test composite specimens as thin as 8 plies and up to 7.6 cm in width for compression strength. This method utilizes a fixture incorporating the best features of the Celanese and IITRI fixtures combined with an antibuckling jig developed at the University of Dayton Research Institute. This new method uses up to 83 percent less material than the most commonly used compression-after-impact technique (which calls for a 48 ply test specimen) and can also be performed on smaller loading frames since a much smaller force is needed to fail the specimen. The thickness of the test specimen can be fabricated to exactly match production part thickness, thus yielding more meaningful results. CAI tests were performed on IM6/3501 carbon/epoxy utilizing this new method. To verify the design, a series of tests were performed in which undamaged specimens were tested using the new fixture and ASTM D 3410-87 (Celanese compression test) and the results compared. The new fixture works well and will be a valuable asset to MSFC's damage tolerance program.

Nettles, Alan T.↗

Force Limit System

The Force Limit System (FLS) was developed to protect test specimens from inadvertent overload. The load limit value is fully adjustable by the operator and works independently of the test system control as a mechanical (non-electrical) device. When a test specimen is loaded via an electromechanical or hydraulic test system, a chance of an overload condition exists. An overload applied to a specimen could result in irreparable damage to the specimen and/or fixturing. The FLS restricts the maximum load that an actuator can apply to a test specimen. When testing limited-run test articles or using very expensive fixtures, the use of such a device is highly recommended. Test setups typically use electronic peak protection, which can be the source of overload due to malfunctioning components or the inability to react quickly enough to load spikes. The FLS works independently of the electronic overload protection.

Pawlik, Ralph↗

The effects of specimen scale on the compression strength of composite materials

This paper presents a number of observations on the effect of specimen scale on the compression response of composite materials. Work on this topic was motivated by observations that thick-walled, unstiffened carbon reinforced cylinders subjected to hydrostatic pressure were not reaching inplane laminate stress levels at failure expected from coupon level properties, while similar cylinders reinforced with fiberglass were. Results from a study on coupon strength of (0/0/90) laminates, reinforced with AS4 carbon fiber and S2 glass fiber, are presented and show that compression strength is not a function of material or specimen thickness for materials that have the same laminate quality (autoclave cured quality). Actual laminate compression strength was observed to decrease with increasing thickness, but this is attributed to fixture restraint effects on coupon response. The hypothesis drawn from the coupon level results is further supported by results from a compression test on a thick carbon reinforced coupon in a fixture with reduced influence on specimen response and from a hydrostatic test on an unstiffened carbon reinforced cylinder subjected to hydrostatic pressure with end closures designed to minimize their effect on cylinder response.

Camponeschi, Eugene Thomas, Jr.↗

Finite element stress analysis of a notched coupon specimen for in-plane shear behaviour of composites

The results of a linear elastic, plane stress finite element investigation of the stress distribution in a double V-notched coupon specimen are presented for an isotropic material (steel) and five graphite/polyimide laminates: (0), (90), (0/90)s, (plus or minus 45)s and (0/90/plus or minus 45)s. Stress contours, stress profiles, and stress concentration factors are presented for specimens loaded through rigid fixtures. It is shown that the finite element analysis predicts a region of essentially uniform pure shear in the central portion of the specimen for all laminates considered. Stress concentrations vary considerably with laminate configuration. The influences of elastic fixtures and thermal stresses on the stress distribution in (0) laminates are also investigated. The (0) laminate is predicted to exhibit maximum pure shear in the center of the test section for both rigid and elastic fixtures. It is concluded that the specimen is a practicable candidate for use as a composite shear specimen.

Herakovich, C. T.↗

Design and test of a magnetic thrust bearing

A magnetic thrust bearing can be employed to take thrust loads in rotating machinery. The design and construction of a prototype magnetic thrust bearing for a high load per weight application is described. The theory for the bearing is developed. Fixtures were designed and the bearing was tested for load capacity using a universal testing machine. Various shims were employed to have known gap thicknesses. A comparison of the theory and measured results is presented.

Allaire, P. E.↗

Fixtures Hold Nuts During Tightening Of Bolts

Two fixtures designed for use on cross-head of tensile testing machine simplify adjustments of crosshead to accommodate specimens of various lengths. Two cagelike fixtures hold pairs of nuts, preventing nuts from turning while bolts are tightened. Enable one person acting alone to tighten bolts.

Gyekenyesi, John Z.↗

Evaluation of the resiliency characteristics of several candidate Solid Rocket Booster O-ring materials

Resiliency tests have been conducted in order to evaluate O-ring sealing response in the revised Space Shuttle SRBs, giving attention to the effects of temperature and gap-opening rates. Additional testing was conducted to ascertain O-ring responses to simulated SRB field-joint deflections. All tests employed a face-seal fixture mounted on a servohydraulic apparatus. The Viton candidate O-ring material tracked the gap-opening rate better at higher temperatures and lower gap-opening rates; it was also the only material inert to the calcium grease employed. Heaters must be used to maintain the 70 F minimum temperature at which the Viton O-ring will track the required gap opening rate.

Lach, C. L.↗