Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tensile testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Matrix plasticity in SiC/Ti-15-3 composite

An experimental method is described which allows for the observation of slip bands due to matrix plasticity in the SiC/Ti-15-3 composite system. A post-test heat treatment and subsequent chemical etch is employed to reveal slip bands in the titanium matrix. Composite specimens of various laminates were examined after tensile testing at room temperature. This method definitively shows that matrix plasticity has occurred in all the laminates investigated and at load/strain levels which were insufficient to cause fiber breakage.

Lerch, Bradley A.↗

In-Situ NDE Characterization of Kevlar and Carbon Composite Micromechanics for Improved COPV Health Monitoring

This project is a subtask of a multi-center project to advance the state-of-the-art by developing NDE techniques that are capable of evaluating stress rupture (SR) degradation in Kevlar/epoxy (K/Ep) composite overwrapped pressure vessels (COPVs), and damage progression in carbon/epoxy (C/Ep) COPVs. In this subtask, acoustic emission (AE) data acquired during intermittent load hold tensile testing of K/Ep and C/Ep composite tow materials-of-construction used in COPV fabrication were analyzed to monitor progressive damage during the approach to tensile failure. Insight into the progressive damage of composite tow was gained by monitoring AE event rate, energy, source location, and frequency. Source location based on arrival time data was used to discern between significant AE attributable to microstructural damage and spurious AE attributable to background and grip noise. One of the significant findings was the observation of increasing violation of the Kaiser effect (Felicity ratio < 1.0) with damage accumulation.

Waller, Jess M.↗

Effects of Electron Irradiation on Candidate Materials for Target Window in Accelerator-Driven Mo-99 Production

Room-temperature (RT) axial tensile tests were conducted in 2018 and 2021 with flat, sub-sized, dog-boned samples of non-irradiated and irradiated Inconel 718 and irradiated beryllium (Be). The sample gauge length was 7.62 mm. Tensile properties of interest are the engineering yield stress (YS), ultimate tensile stress (UTS), uniform elongation (UE) and total elongation (TE). The electron dose of the 2021 samples was ≈2 times the dose of samples tested in 2018. Relative dose rates of 0, 1 (2018), and 2 (2021) are assigned to these samples. The 2021 electron-irradiated Be samples were brittle with a low failure stress of 338±64 MPa based on two samples. The failures occurred in the gauge section. The 2018 results for electron-irradiated Be indicated a slight decrease in ductility and strength for the one electron-irradiated sample that failed in the gauge section.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison of Elastic Moduli of LPBF 316H Material Using RUS Measurements and Destructive Mechanical Testing

Preliminary results are presented on performing Resonance Ultrasound Spectroscopy (RUS) measurements on stainless steel 316 H fabricated using Laser Powder Bed Fusion (LPBF) additive manufacturing methods. The elastic constants determined using RUS measurements are compared to tensile tests and RUS measurements on wrought stainless steel 316 L. Good agreement is found between the RUS measurements and the mechanical testing results.

36 MATERIALS SCIENCE↗

Tritium embrittlement of austenitic stainless-steel tubing at low helium contents

Austenitic stainless steels are the standard materials for containment of hydrogen and tritium because of their resistance to mechanical property degradation in those environments. The mechanical performance of the primary containment material is critical for tritium handling, processing, and storage, thus comprehensive understanding of the processes of tritium embrittlement is an enabling capability for fusion energy. This work describes the investigation of the effects of low levels of tritium-decay-helium ingrowth on 304 L tubes. Long-term aging with tritium leads to high helium contents in austenitic stainless steels and can reduce fracture toughness by 95 %, but the details of behavior at low helium contents are not as well characterized. Here, we present results from tensile testing of tritium pre-charged 304 L tube specimens with a variety of starting microstructures that all contain a low level of helium. The results of the tritium exposed-and-aged materials are compared to previously reported results on similar specimens tested in an unexposed condition as well as the hydrogen precharged condition. Tritium precharging and aging for a short duration resulted in increased yield strengths, ultimate tensile strengths and slightly increased elongation to failure, comparable to higher concentrations of hydrogen precharging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing device subjects elastic materials to biaxial deformations

Testing device stretches elastic materials biaxially over large deformation ranges and varies strain ratios in two perpendicular directions. The device is used in conjunction with a tensile testing machine, which holds the specimen and permits control over the direction and magnitude of the stresses applied.

Becker, G. W.↗

Experimental investigation of graphite/polyimide sandwich panels in edgewise compression

The local and general buckling behavior of graphite/polyimide sandwich panels simply supported along all four edges and loaded in uniaxial edgewise compression was investigated. Material properties of adhesive and facings were determined from flatwise tension and sandwich beam flexure tests. Tensile and compressive material properties of the facings were determined at 116, R.T., and 589 K (-250, R.T., and 600 F) using the sandwich beam flexure test method. Results indicate that Gr/PI is a usable structural material for short term use at temperatures as high as 589 K (600 F). Buckling specimens were 30.5 X 33.0 cm (12 x 13 in.), had quasi-isotropic symmetric facings and a glass/polyimide honeycomb core. Core thicknesses varied and three panels of each thickness were tested in edgewise compression at room temperature to investigate failure modes and corresponding buckling formulas. Specimens 0.635 cm (0.25 in.) thick failed by overall buckling at loads close to the analytically predicted buckling load; all other panels failed by face wrinkling. Results of the winkling tests indicate that several buckling formulas were unconservative and therefore not suitable for design purposes; recommended wrinkling equations are presented.

Camarda, C. J.↗

The effect of hydrogen on the deformation behavior of a single crystal nickel-base superalloy

The effect of hydrogen on the tensile deformation behavior of PWA 1480 is presented. Tensile tests were interrupted at different plastic strain levels to observe the development of the dislocation structure. Transmission electron microscopy (TEM) foils were cut perpendicular to the tensile axis to allow the deformation of both phases to be simultaneously observed as well as parallel to zone axes (III) to show the superdislocations on their slip planes. Similar to other nickel-base superalloys, hydrogen was detrimental to the room temperature tensile properties of PWA 1480. There was little effect on strength, however the material was severely embrittled. Even without hydrogen, the elongation-to-failure was only approximately 3 percent. The tensile fracture surface was made up primarily of ductile voids with regions of cleavage fracture. These cleavage facets are the eutectic (gamma') in the microstructure. It was shown by quantitative fractography that hydrogen embrittles the eutectic (gamma') and causes the crack path to seek out and fracture through the eutectic (gamma'). There was two to three times the amount of cleavage on the fracture surface of the hydrogen-charged samples than on the surface of the uncharged samples. The effect of hydrogen can also be seen in the dislocation structure. There is a marked tendency for dislocation trapping in the gamma matrix with and without hydrogen at all plastic strain levels. Without hydrogen there is a high dislocation density in the gamma matrix leading to strain exhaustion in this region and failure through the matrix. The dislocation structure at failure with hydrogen is slightly different. The TEM foils cut parallel to zone axes (III) showed dislocations wrapping around gamma precipitates. Zone axes (001) foils show that there is a lower dislocation density in the gamma matrix which can be linked to the effects of hydrogen on the fracture behavior. The primary activity in the gamma precipitates is in the form of superlattice intrinsic stacking faults (SISFs). These faults have also been reported in other ordered alloys and superalloys.

Walston, W. S.↗

Mechanical Properties of Triaxial Braided Carbon/Epoxy Composites

In an on-going effort to increase the safety and efficiency of turbine engines, the National Aeronautics and Space Administration is exploring lightweight alternatives to the metal containment structures that currently encase commercial jet engines. Epoxy reinforced with braided carbon fibers is a candidate structural material which may be suitable for an engine case. This paper reports flat-coupon mechanical-property experiments performed to compliment previously reported subcomponent impact testing and analytical simulation of containment structures. Triaxial-braid T700/5208 epoxy and triaxial-braid T700/M36 toughened epoxy composites were evaluated. Also, two triaxial-braid architectures (0 +/- 60 deg., 0 +/- 45 deg.) with the M36 resin were evaluated through tension, compression, and shear testing. Tensile behavior was compared between standard straight-sided specimens (ASTM D3039) and bowtie specimens. Both double-notch shear (ASTM D3846) and Iosepescu (ASTM D5379) tests were performed as well. The M36/0 +/- 45 deg. configuration yield the best response when measurements were made parallel to the axial tows. Conversely, the M36/0 +/- 60 deg. configuration was best when measurements were made perpendicular to the axial tows. The results were used to identify critical properties and to augment the analysis of impact experiments.

Bowman, C. L.↗

Mechanical Behaviour of Woven Graphite/Polyimide Composites with Medium and High Modulus Graphite Fibers Subjected to Biaxial Shear Dominated Loads

A major limitation of woven fiber/polymer matrix composite systems is the inability of these materials to resist intralaminar and interlaminar damage initiation and propagation under shear-dominated biaxial loading conditions. There are numerous shear test methods for woven fabric composites, each with its own advantages and disadvantages. Two techniques, which show much potential, are the Iosipescu shear and +/- 45 deg tensile tests. In this paper, the application of these two tests for the room and high temperature failure analyses of woven graphite/polyimide composites is briefly evaluated. In particular, visco-elastic micro, meso, and macro-stress distributions in a woven eight harness satin (8HS) T650/PMR-15 composite subjected to these two tests are presented and their effect on the failure process of the composite is evaluated. Subsequently, the application of the Iosipescu tests to the failure analysis of woven composites with medium (T650) and high (M40J and M60J) modulus graphite fibers and PMR-15 and PMR-II-50 polyimide resins is discussed. The composites were tested as-supplied and after thermal conditioning. The effect of temperature and thermal conditioning on the initiation of intralaminar damage and the shear strength of the composites was established.

Kumose, M.↗

The Effect of Heating on the Degradation of Ground Laboratory and Space Irradiated Teflon® FEP

The outer most layer of the multilayer insulation (MLI) blankets on the Hubble Space Telescope (HST) is back surface aluminized Teflon® FEP (fluorinated ethylene propylene). As seen by data collected after each of the three servicing missions and as observed during the second servicing mission (SM2), the FEP has become embrittled in the space environment, leading to degradation of the mechanical properties and severe on-orbit cracking of the FEP. During SM2, a sample of aluminized-FEP was retrieved from HST that had cracked and curled, exposing its aluminum backside to space. Because of the difference in optical properties between FEP and aluminum, this insulation piece reached 200 C on-orbit, which is significantly higher than the nominal MLI temperature extreme of 50 C. This piece was more brittle than other retrieved material from the first and third servicing missions (SM1 and SM3A, respectively). Due to this observation and the fact that Teflon thermal shields on the solar array bi-stems were heated on-orbit to 130 C, experiments have been conducted to determine the effect of heating on the degradation of FEP that has been irradiated in a ground laboratory facility or in space on HST. Teflon FEP samples were x-ray irradiated in a high vacuum facility in order to simulate the damage caused by radiation in the space environment. Samples of pristine FEP, x-ray irradiated FEP and FEP retrieved from the HST during SM3A were heat treated from 50 to 200 C at 25intervals in a high vacuum facility and then tensile tested. In addition, samples were tested in a density gradient column to determine the effect of the radiation and heating on the density of FEP. Results indicate that although heating does not degrade the tensile properties of non-irradiated Teflon, there is a significant dependence of the percent elongation at failure of irradiated Teflon as a function of heating temperature. Irradiated Teflon was found to undergo increasing degradation in the elongation at failure as temperature was increased from room temperature to 200 C. Rate of degradation changes, which were consistent with the glass I transition temperatures for FEP, appeared to be present in both tensile and density data. The results indicate the significance of the on-orbit temperature of Teflon FEP with respect to its degradation in the low Earth orbital space environment.

Hubble Space Telescope↗

Size-dependent stochastic tensile properties in additively manufactured 316L stainless steel

Recent work in metal additive manufacturing (AM) suggests that mechanical properties may vary with feature size; however, these studies do not provide a statistically robust description of this phenomenon, nor do they provide a clear causal mechanism. Because of the huge design freedom afforded by 3D printing, AM parts typically contain a range of feature sizes, with particular interest in smaller features, so the size effect must be well understood in order to make informed design decisions. This work investigates the effect of feature size on the stochastic mechanical performance of laser powder bed fusion tensile specimens. A high-throughput tensile testing method was used to characterize the effect of specimen size on strength, elastic modulus and elongation in a statistically meaningful way. The effective yield strength, ultimate tensile strength and modulus decreased strongly with decreasing specimen size: all three properties were reduced by nearly a factor of two as feature dimensions were scaled down from 6.25 mm to 0.4 mm. Hardness and microstructural observations indicate that this size dependence was not due to an intrinsic change in material properties, but instead the effects of surface roughness on the geometry of the specimens. Finite element analysis using explicit representations of surface topography shows the critical role surface features play in creating stress concentrations that trigger deformation and subsequent fracture. The experimental and finite element results provide the tools needed to make corrections in the design process to more accurately predict the performance of AM components.

316L stainless steel↗

Co-Extrusion of Dissimilar Aluminum Alloys via Shear-Assisted Processing and Extrusion

Bimetallic tubes are used when a component requires more than one performance requirement, for instance, strength/creep resistance and oxidation/corrosion resistance. Shear-assisted processing and extrusion (ShAPE) can be used to fabricate extrudates that are comparable or superior in performance relative to conventionally manufactured extrudates. For the first time, ShAPE has been successfully employed in producing bimetallic Al tubing consisting of 6061 and 7075 Al alloys. Both light and electron microscopy techniques were used to investigate the integrity of the tubes, especially the interface between the core and cladding of the bimetallic tubes. Void-free bimetallic tubes were produced using ShAPE. Quantification of tube integrity was carried out with tensile testing under as-extruded and post-aged conditions. All the bimetallic tubes in the as-extruded samples exhibited uniform elongation above 5% with good tensile strength. Key insights such as material flow during bimetallic tube extrusion were obtained from the characterization of remnant billet and simulation results from a smoothed particle hydrodynamics model.

36 MATERIALS SCIENCE↗

Method and apparatus for gripping uniaxial fibrous composite materials

A strip specimen is cut from a unidirectional strong, brittle fiber composite material, and the surfaces of both ends of the specimen are grit blasted. The specimen is then placed between metal load transfer members having grit blasted surfaces. Sufficient compressive stress is applied to the load transfer members to prevent slippage during testing at both elevated temperatures and room temperatures. The need for adhesives, load pads, and other secondary composite processing is eliminated. This gripping system was successful in tensile testing, creep rupture testing, and fatigue testing uniaxial composite materials at 316 C.

Whittenberger, J. D.↗

The Evolution of the Deformation Substructure in a Ni-Co-Cr Equiatomic Solid Solution Alloy

The equiatomic NiCoCr alloy exhibits an excellent combination of strength and ductility, even greater than the FeNiCrCoMn high entropy alloy, and also displays a simultaneous increase in strength and ductility with decreasing the testing temperature. To systemically investigate the origin of the exceptional properties of NiCoCr alloy, which are related to the evolution of the deformation substructure with strain, interrupted tensile testing was conducted on the equiatomic NiCoCr single-phase solid solution alloy at both cryogenic and room temperatures at five different plastic strain levels of 1.5%, 6.5%, 29%, 50% and 70%. The evolution of deformation substructure was examined using electron backscatter diffraction (EBSD), transmission Kikuchi diffraction (TKD), conventional transmission electron microscopy (CTEM), diffraction contrast imaging using STEM (DCI-STEM) and atomic resolution scanning transmission electron microscopy. While the deformation substructure mainly consisted of planar dislocation slip and the dissociation of dislocations into stacking faults at small strain levels (≤6.5%), at larger strain levels, additional substructures including nanotwins and a new phase with hexagonal close packed (HCP) lamellae also appeared. The volume fraction of the HCP lamellae increases with increasing deformation, especially at cryogenic temperature. First principles calculations at 0 K indicate that the HCP phase is indeed energetically favorable relative to FCC for this composition. The effects of the nanotwin and HCP lamellar structures on hardening rate and ductility at both cryogenic and room temperature are qualitatively discussed.

Twinning↗

Impact of Low-Temperature Neutron Irradiation on Tensile Behavior of Base Metal and Electron-Beam Welded 316L Stainless Steel

Here, a study of 316L type stainless steel in its base metal and electron-beam (e-beam) welded conditions was performed to observe the effects of low-temperature (60 °C to 100 °C) neutron irradiation on the tensile behavior of the samples. Fractography was used in understanding the tensile-tested fracture surfaces of the 316L samples in these different forms with the characterization of the both base metal and welded samples using electron microscopy. Irradiation of the tensile specimens made free of defects of cutting and mechanical polishing showed a reduction in their tensile ductility with increased radiation-induced hardening up to 1.40 × 10 19 n/cm 2 (E > 0.1 MeV) fluence that corresponds to 1.1x 10 -2 dpa, even at the low irradiation temperatures. These low-temperature neutron irradiated base metal and e-beam welded 316L specimens also consisted of closely similar fracture surfaces characteristic of ductile rupture.

36 MATERIALS SCIENCE↗