Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOSTATS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Novel Hardware for a Lunar Plant Experiment

We propose an experiment, LPX (Lunar plant growth experiment), on the surface of the Moon that will conduct a fundamental investigation into the response of the plant Arabidopsis to lunar gravity and lunar radiation. For statistical significance, we will include more than 50 seeds. The experiment begins after lunar landing with water added to the seed platform and continues for 10 days or more. The growth of the plants, reaching ~ 1 cm high with typically 3-4 leaves in 10 days, will be monitored by camera and the carbon dioxide in the sealed chamber also will be monitored. The hardware for the LPX is based on proven technology flown on the ISS in Dec 2019 (Kitto et al. 2021, Life Sci. Space Res. in press) and the “Phytofuge” canister for Techshot MVP (Multi-use Variable-gravity Platform) centrifuge – both on ISS now. Both of these systems are TRL 9. This approach will allow identical units to be sent to the Moon and to be flown on ISS - allowing direct comparisons to partial gravity experiments done on the ISS experiment. Germination and growth of Arabidopsis requires temperature range of 20–25°C with the optimum being 22–23°C (Shymanovich and Kiss 2020, Gravit. & Space Res., 8, 1-7). This level of thermal control is a challenge on a small lunar lander and is effectively set by the latitude of the landing site. Given the mass and power limitations on a small lander, and the internal power of the LPX (~ 5W) the landing site needs to be between 73° and 77° − for which the noon time lunar surface temperatures are +15°C and -3°C (Hurley et al. 2015, Icarus 255,159-163). Within this range the temperature can be set with a small thermostatically-controlled heater These proposed experiments would be the first to grow plants on another planet and would provide important insights in terms of growth of plants on the Moon as part of bioregenerative life support.

Christopher P Mckay↗

Mechanical Pumped Cooling Loop for Spacecraft Thermal Control

Passive elements such as surface finishes, insulation, thermostats, radiators and louvers help keep spacecraft temperatures within the required limits. Mechanically pumped, single-phase cooling loops have been used for short-term applications such as the Space Shuttle. They are flexible, robust, and allow thermal autonomy. A lack of design heritage limits their use to shorter missions .

passive↗

Thermal design and validation of Mars 202 gas Dust Removal Tool (gDRT)

As part of the science goals for the planned Mars 2020 mission, two instruments, PIXL and SHERLOC, intend to study the Mars surface at a close scale. These two instruments are planned to be used on smooth rock surfaces that are free of dust and other particles. Such surfaces are prepared by using a drill with an abrading drill bit; residual dust and particles are then blown away using a compressed gas system—the Gas Dust Removal Tool (gDRT). Early in the design process a risk of valve leakage below the vendor’s -20C rating was identified. To mitigate this risk a parallel path was implemented: 1) qualify the valves to operate at -135C, and 2) develop thermal control capability to elevated temperatures in case qualification efforts are unsuccessful. While qualification efforts are ongoing, it is expected that the valves will be qualified to an operating temperature of -135C. In the event that qualification is not successful, thermal control has been realized via a thermally isolated valve configuration and thermostatically controlled heaters. Thermal testing of gDRT has validated this design and enabled thermal model correlation in order to provide more accurate survival energy predictions. The resulting energy consumption for heating the valves at the Jezero landing site represents a minimal impact to the Rover energy budget.

Novak, Keith↗

Nitric Oxide Cooling and Concentrations Derived from SABER

- Motivation and Objective: - Nitric Oxide : - Is a thermostat of the thermosphere. - plays important role in regulating the energy budget in the thermosphere. - Long term precise datasets of NO cooling and NO concentration are of great important. - Objective: - Derive the NO cooling from SABER measurements by using new unfiltered factor. - Derive the NO concentration from SABER NO cooling and MSIS simulations.

SABER↗

Effect of Aromaticity on Soot Formation: A Reactive Molecular Dynamics Study

This study investigates the formation of soot from n-dodecane and its blend with m-xylene under pyrolytic and low-oxygen conditions with reactive molecular dynamics (MD) simulations. ReaxFF force field is used to simulate the interactions of fuel and oxygen molecules at engine-relevant conditions (2500-3500 K and 70-75 bar). Fuel molecules with carbon atom density of 0.03 g/cm 3 are dispersed into a cube and constant temperature simulations are carried out with a Nosé-Hoover thermostat. Pyrolysis of n-dodecane and the chemical pathway towards the formation of aromatic hydrocarbons are investigated. The initial pyrolysis rate of n-dodecane is observed to be slightly higher with the addition of aromatic compounds and oxygen. While the first aromatics formed from the decomposed n-dodecane are phenyl radicals at 2500 K, decomposition of the aliphatic fuel compound is observed to be necessary to build a carbon cluster, and eventually soot. Morphological properties of the created soot particles are also analyzed. The maturity, size and aromatics content of the soot particle are slightly affected with the addition of m-xylene and oxygen at 3500 K within the 3 ns simulation time possibly due the formation of larger and more condensed aromatic rings, resulting in larger soot molecules. The outcomes of this study provide important insights into the formation mechanism of soot and its morphological characteristics depending on varying fuel concentrations at pyrolysis and low oxygen engine conditions. Results of this analysis will further contribute to the understanding of contrail formation on generated soot particles originated from the combustion of different chemical components with particle chemistry matching companion experiments.

soot formation↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling↗

Prediction of Air Mixing From High Sidewall Diffusers in Cooling Mode: Preprint

Computational fluid dynamics modeling was used to evaluate the performance of high sidewall air supply in cooling mode. The research focused on the design, placement, and operation of air supply diffusers located high on a sidewall and return grilles located near the floor on the same sidewall. Parameters of the study are the supply velocity, supply temperature, diffuser dimensions and roomdimensions. Thermal loads characteristic of high performance homes were applied at the walls and room temperature was controlled via a thermostat. The results are intended to provide information to guide the selection of high sidewall supply diffusers to provide proper room mixing for cooling of high performance homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Improvements for Air Source Heat Pumps using Different Expansion Devices at Varied Charge Levels Part II

This paper describes steady-state performance simulations performed on a 3-ton R-22 split heat pump in heating mode. In total, 150 steady-state points were simulated, which covers refrigerant charge levels from 70 % to 130% relative to the nominal value, the outdoor temperatures at 17 F (-8.3 C), 35 F (1.7 C) and 47 F (8.3 C), indoor air flow rates from 60% to 150% of the rated air flow rate, and two types of expansion devices (fixed orifice and thermostatic expansion valve). A charge tuning method, which is to calibrate the charge inventory model based on measurements at two operation conditions, was applied and shown to improve the system simulation accuracy significantly in an extensive range of charge levels. In addition, we discuss the effects of suction line accumulator in modeling a heat pump system using either a fixed orifice or thermal expansion valve. Last, we identify the issue of refrigerant mass flow mal-distribution at low charge levels and propose an improved modeling approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic Optimal Control for Series Hybrid Electric Vehicles

Increasing demand for improving fuel economy and reducing emissions has stimulated significant research and investment in hybrid propulsion systems. In this paper, we address the problem of optimizing online the supervisory control in a series hybrid configuration by modeling its operation as a controlled Markov chain using the average cost criterion. We treat the stochastic optimal control problem as a dual constrained optimization problem. We show that the control policy that yields higher probability distribution to the states with low cost and lower probability distribution to the states with high cost is an optimal control policy, defined as an equilibrium control policy. We demonstrate the effectiveness of the efficiency of the proposed controller in a series hybrid configuration and compare it with a thermostat-type controller.

fuel economy↗

Compare Energy Use in Variable Refrigerant Flow Heat Pumps Field Demonstration and Computer Model

Variable Refrigerant Flow (VRF) heat pumps are often regarded as energy efficient air-conditioning systems which offer electricity savings as well as reduction in peak electric demand while providing improved individual zone setpoint control. One of the key advantages of VRF systems is minimal duct losses which provide significant reduction in energy use and duct space. However, there is limited data available to show their actual performance in the field. Since VRF systems are increasingly gaining market share in the US, it is highly desirable to have more actual field performance data of these systems. An effort was made in this direction to monitor VRF system performance over an extended period of time in a US national lab test facility. Due to increasing demand by the energy modeling community, an empirical model to simulate VRF systems was implemented in the building simulation program EnergyPlus. This paper presents the comparison of energy consumption as measured in the national lab and as predicted by the program. For increased accuracy in the comparison, a customized weather file was created by using measured outdoor temperature and relative humidity at the test facility. Other inputs to the model included building construction, VRF system model based on lab measured performance, occupancy of the building, lighting/plug loads, and thermostat set-points etc. Infiltration model inputs were adjusted in the beginning to tune the computer model and then subsequent field measurements were compared to the simulation results. Differences between the computer model results and actual field measurements are discussed. The computer generated VRF performance closely resembled the field measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of Ventilation Energy Demands and Indoor Air Quality in High-Performance Homes

High-performance homes require that ventilation energy demands and indoor air quality (IAQ) be simultaneously optimized. We attempted to bridge these two areas by conducting tests in a research house located in Oak Ridge, TN, that was 20 months old, energy-efficient (i.e., expected to consume 50% less energy than a house built per the 2006 IRC), tightly-built (i.e., natural ventilation rate ~0.02 h-1), unoccupied, and unfurnished. We identified air pollutants of concern in the test home that could generally serve as indicators of IAQ, and conduced field experiments and computer simulations to determine the effectiveness and energy required by various techniques that lessened the concentration of these contaminants. Formaldehyde was selected as the main pollutant of concern among the contaminants that were sampled in the initial survey because it was the only compound that showed concentrations that were greater than the recommended exposure levels. Field data indicate that concentrations were higher during the summer primarily because emissions from sources rise with increases in temperature. Furthermore, supply ventilation and gas-phase filtration were effective means to reduce formaldehyde concentrations; however, exhaust ventilation had minimal influence on this pollutant. Results from simulations suggest that formaldehyde concentrations obtained while ventilating per ASHRAE 62.2-2010 could be decreased by about 20% from May through September through three strategies: 1) increasing ASHRAE supply ventilation by a factor of two, 2) reducing the thermostat setpoint from 76 to 74 F, or 3) running a gas-phase filtration system while decreasing supply ventilation per ASHRAE by half. In the mixed-humid climate of Oak Ridge, these strategies caused increases in electricity cost of ~$5 to ~$15/month depending on outdoor conditions.

Hun, Diana E↗

Building America Case Study: Low-Cost Evaluation of Energy Savings at the Community Scale, Fresno, California (Fact Sheet)

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory.). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts (Fact Sheet)

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assembling Appliances Standards from a Basket of Functions

Rapid innovation in product design challenges the current methodology for setting standards and labels, especially for electronics, software and networking. Major problems include defining the product, measuring its energy consumption, and choosing the appropriate metric and level for the standard. Most governments have tried to solve these problems by defining ever more specific product subcategories, along with their corresponding test methods and metrics. An alternative approach would treat each energy-using product as something that delivers a basket of functions. Then separate standards would be constructed for the individual functions that can be defined, tested, and evaluated. Case studies of thermostats, displays and network equipment are presented to illustrate the problems with the classical approach for setting standards and indicate the merits and drawbacks of the alternative. The functional approach appears best suited to products whose primary purpose is processing information and that have multiple functions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Customer Engagement in AEP gridSMART Residential Transactive System

— In 2013, AEP Ohio (AEP) operated a 5-minute real-time price (RTP) electricity market system on 4 distribution feeders as part of their gridSMART® demonstration project. The RTP households were billed for their electricity usage according to an RTP tariff approved by the Public Utility Commission of Ohio. They were given the incentive that their annual bill would be no greater than if they were on the flat-rate tariff, but they had financial incentives to shift consumption from high price periods to low price periods. Incentives were also available for response under high prices from local events, such as reaching the distribution feeder capacity or a critical peak pricing event. An analysis of this transactive system experiment was completed in early 2014. This paper describes the incentive provided to the customer, the nature of their interaction with the smart thermostat that provided automated response to the transactive signal, and their level of satisfaction with the program.

Widergren, Steven E.↗

New Whole-House Solutions Case Study: Low-Cost Evaluation of Energy Savings at the Community Scale - Fresno, California

In this project, IBACOS partnered with builder Wathen-Castanos Hybrid Homes to develop a simple and low-cost methodology by which community-scale energy savings can be evaluated based on results at the occupied test house level.Research focused on the builder and trade implementation of a whole-house systems integrated measures package and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

Building America↗

New Whole-House Case Study: William Ryan Homes, Tampa, Florida

The builder worked with Consortium for Advanced Residential Buildings to design HERS-65 homes with energy-efficient heat pumps and programmable thermostats with humidity controls, foam-filled concrete block walls, draining house wrap, and airsealed kneewalls.

attic kneewalls↗