Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Rod gripper, changer, and storage system

A rod changer and storage design is presented for the lunar deep drill apparatus to be used in conjunction with the Skitter walking platform. The design must take into account all of the lunar environment and working conditions. Some of these are: (1) the moon has one sixth the gravity of earth; (2) temperature gradients can range from about -170 to 265 C; (3) because of the high transportation costs, the design must be as light as possible; and (4) the process must be remotely operated (from earth or satellite) and must be automated. Because of Skitter's multiple degree of freedom movement, the design will utilize Skitter's movement to locate an implement and transport it from the rack to the drill string. The implement will be gripped by a thumb and two finger device, identified through an electronic sensing device on the thumb, and transported from the rack to the footplate and back from the footplate to the rack. The major designs discussed in this report have been broken down into three major areas: (1) gripper design (linear transport mechanism); (2) indexing system; and (3) rack design.

Benson, Mark↗

DOE OE Energy Storage Systems Safety Roadmap Focus on Proposed Changes to the ICC International Codes Special Briefing Paper — Unofficial Hearing Results April 2018

The goal of the DOE OE ESS Safety Roadmap1 is to foster confidence in the safety and reliability of energy storage systems (ESSs). Three interrelated objectives support the realization of that goal: research, codes and standards, and communication/coordination. The objective focused on codes and standards is - To apply research and development (R&D) to support efforts that are focused on ensuring that codes and standards are available to enable the safe implementation of ESSs in a comprehensive, non-discriminatory and science-based manner. The purpose of this special briefing paper is to support the above objective by providing information about current and upcoming efforts being conducted by U.S. standards developing organizations, specifically code changes associated with the 2018 Group A International Codes (I-Codes) of the International Code Council (ICC) that are relevant to ESSs.

25 ENERGY STORAGE↗

Identification and evaluation for the mercury solar photovoltaic array and battery energy storage system, area 23, nevada national security site, nye county, nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to construct a solar photovoltaic (PV) energy generation array and an associated Battery Energy Storage System (BESS) in the town of Mercury at the Nevada National Security Site (NNSS) in Nye County, Nevada. The purposes of the development of this facility are to support long-term efforts to modernize Mercury and to provide energy-resilient infrastructure and climate adaptation needs.

25 ENERGY STORAGE↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

Data analytics and optimization of an ice-based energy storage system for commercial buildings

Ice-based thermal energy storage (TES) systems can shift peak cooling demand and reduce operational energy costs (with time-of-use rates) in commercial buildings. The accurate prediction of the cooling load, and the optimal control strategy for managing the charging and discharging of a TES system, are two critical elements to improving system performance and achieving energy cost savings. This study utilizes data-driven analytics and modeling to holistically understand the operation of an ice–based TES system in a shopping mall, calculating the system’s performance using actual measured data from installed meters and sensors. Results show that there is significant savings potential when the current operating strategy is improved by appropriately scheduling the operation of each piece of equipment of the TES system, as well as by determining the amount of charging and discharging for each day. A novel optimal control strategy, determined by an optimization algorithm of Sequential Quadratic Programming, was developed to minimize the TES system’s operating costs. Three heuristic strategies were also investigated for comparison with our proposed strategy, and the results demonstrate the superiority of our method to the heuristic strategies in terms of total energy cost savings. Specifically, the optimal strategy yields energy costs of up to 11.3% per day and 9.3% per month compared with current operational strategies. A one-day-ahead hourly load prediction was also developed using machine learning algorithms, which facilitates the adoption of the developed data analytics and optimization of the control strategy in a real TES system operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation of Remote Acquisition and Storage System

The existing system for gathering and processing acoustical test data had several shortcomings and limitations in the areas of microphone array size, sampling rate, and background noise. A new Remote Acquisition and Storage System (RASS) is being designed for applications not suited for the existing acquisition system. One of the first tasks in the design of the RASS was to redesign the microprocessor card of the existing system to include RS-232 serial ports to accept communications through the radio modem used in the RF link. Cost and parts availability comparisons were made between the newly designed board and commercially available models, and a commercially made model was selected. This model was tested for basic I/0 operations. The prototype of the RF telemetry system was set up and tested. Plans are now being developed for integrating the RF telemetry system with the other RASS subsystems.

Hess, Jason R.↗

Mass storage system experiences and future needs at the National Center for Atmospheric Research

This presentation is designed to relate some of the experiences of the Scientific Computing Division at NCAR dealing with the 'data problem'. A brief history and a development of some basic Mass Storage System (MSS) principles are given. An attempt is made to show how these principles apply to the integration of various components into NCAR's MSS. There is discussion of future MSS needs for future computing environments.

Olear, Bernard T.↗

Energy storage systems for electrical microgrids with pulsed power loads

Pulsed power loads (PPLs) are highly non-linear and can cause significant stability and power quality issues in an electrical microgrid. According to the present invention, many of these issues can be mitigated by an Energy Storage System (ESS) that offsets the PPL. The ESS can maintain a constant bus voltage and decouple the generation sources from the PPL. For example, the ESS specifications can be obtained with an ideal, band-limited hybrid battery and flywheel system.

Weaver, Wayne W.↗

The NASA Redox Storage System Development project, 1980

The technical accomplishments pertaining to the development of Redox systems and related technology are outlined in terms of the task elements: prototype systems development, application analyses, and supporting technology. Prototype systems development provides for a major procurement to develop an industrial capability to take the current NASA Lewis technology and go on to the design, development, and commercialization of iron-chromium Redox storage systems. Application analyses provides for the definition of application concepts and technology requirements, specific definition studies, and the identification of market sectors and their penetration potential. Supporting technology includes both in house and contractual efforts that encompass implementation of technology improvements in membranes, electrodes, reactant processing, and system design. The status of all elements is discussed.

Source record↗

Coordinated Control Strategy of a Battery Energy Storage System to Support a Wind Power Plant Providing Multi-Timescale Frequency Ancillary Services

With increasing penetrations of wind generation on electric grids, wind power plants (WPPs) are encouraged to provide frequency ancillary services (FAS); however, it is a challenge to ensure that variable wind generation can reliably provide these ancillary services. This paper proposes using a battery energy storage system (BESS) to ensure the WPPs' commitment to FAS. This method also focuses on reducing the BESS's size and extending its lifetime. In this paper, a state-machine-based coordinated control strategy is developed to utilize a BESS to support the obliged FAS of a WPP (including both primary and secondary frequency control). This method takes into account the operational constraints of the WPP (e.g., real-time reserve) and the BESS (e.g., state of charge [SOC], charge and discharge rate) to provide reliable FAS. Meanwhile, an adaptive SOC-feedback control is designed to maintain SOC at the optimal value as much as possible and thus reduce the size and extend the lifetime of the BESS. In conclusion, the effectiveness of the control strategy is validated with an innovative, multi-area, interconnected power system simulation platform that can mimic realistic power systems operation and control by simulating real-time economic dispatch, regulating reserve scheduling, multi-area automatic generation control, and generators' dynamic response.

25 ENERGY STORAGE↗

Integration and Validation of a Thermal Energy Storage System for Electric Vehicle Cabin Heating

It is widely recognized in the automotive industry that, in very cold climatic conditions, the driving range of an Electric Vehicle (EV) can be reduced by 50% or more. In an effort to minimize the EV range penalty, a novel thermal energy storage system has been designed to provide cabin heating in EVs and Plug-in Hybrid Electric Vehicles (PHEVs) by using an advanced phase change material (PCM). This system is known as the Electrical PCM-based Thermal Heating System (ePATHS) [1, 2]. When the EV is connected to the electric grid to charge its traction battery, the ePATHS system is also “charged” with thermal energy. The stored heat is subsequently deployed for cabin comfort heating during driving, for example during commuting to and from work.The ePATHS system, especially the PCM heat exchanger component, has gone through substantial redesign in order to meet functionality and commercialization requirements. The final system development for EV implementation has occurred on a mid-range EV and has been evaluated for its capability to extend the driving range. Both simulated driving in a climatic tunnel and actual road testing have been carried out. The ePATHS has demonstrated its ability to supply the entire cabin heating needs for a round trip commute totaling 46 minutes, including 8 hours of parking, at an ambient temperature of -10°C.

Wang, Mingyu↗

Energy Storage System Guide for Compliance with Safety Codes and Standards

Codes, standards and regulations (CSR) governing the design, construction, installation, commissioning and operation of the built environment are intended to protect the public health, safety and welfare. While these documents change over time to address new technology and new safety challenges there is generally some lag time between the introduction of a technology into the market and the time it is specifically covered in model codes and standards developed in the voluntary sector. After their development, there is also a timeframe of at least a year or two until they are adopted. Until existing model codes and standards are updated or new ones developed and then adopted, one seeking to deploy energy storage technologies or needing to verify an installation’s safety may be challenged in applying current CSRs to an energy storage system (ESS).

25 ENERGY STORAGE↗

dCache: The Storage System of Choice for Data-Intensive Applications

The ever-increasing volumes of data produced by modern scientific facilities like EuXFEL and LHC put significant stress on data management infrastructure operated by laboratories and research centers. The challenges to be addressed span the entire data life cycle, from ingest and efficient data analysis to long-term preservation, typically involving large tape libraries. dCache, a storage system developed in collaboration between the Deutsches Elektronen-Synchrotron (DESY), Fermi National Accelerator Laboratory, and Nordic e-Infrastructure Collaboration (NeIC), is designed to manage a large number of disk servers and to facilitate transparent data migration to and from archival storage. Its multifaceted approach offers a unified method to support a variety of scientific use cases with the same storage infrastructure, including high-throughput data ingest, data sharing over wide area networks, efficient access from HPC clusters, and long-term data preservation on tertiary storage. Initially developed for high energy physics (HEP) experiments, dCache is now used by various scientific communities, including astrophysics, biomedical research, and life sciences, each having specific requirements. This paper presents architecture, deployment strategies, performance and scalability enhancements, and recent advancements in dCache addressing the needs of scientific communities. Finally, we touch on the development and release process, ensuring the software’s high quality.

DCache↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗