Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model

Variations in the levels of muscle hemoglobin and of myoglobin oxygen saturation can be detected non-invasively with near-infrared spectroscopy. This technique could be applied to the diagnosis of chronic compartment syndrome, in which invasive testing has shown increased intramuscular pressure associated with ischemia and pain during exercise. We simulated chronic compartment syndrome in ten healthy subjects (seven men and three women) by applying external compression, through a wide inflatable cuff, to increase the intramuscular pressure in the anterior compartment of the leg. The tissue oxygenation of the tibialis anterior muscle was measured with near-infrared spectroscopy during gradual inflation of the cuff to a pressure of forty millimeters of mercury (5.33 kilopascals) during fourteen minutes of cyclic isokinetic dorsiflexion and plantar flexion of the ankle. The subjects exercised with and without external compression. The data on tissue oxygenation for each subject then were normalized to a scale of 100 per cent (the baseline value, or the value at rest) to 0 per cent (the physiological minimum, or the level of oxygenation achieved by exercise to exhaustion during arterial occlusion of the lower extremity). With external compression, tissue oxygenation declined at a rate of 1.4 +/- 0.3 per cent per minute (mean and standard error) during exercise. After an initial decrease at the onset, tissue oxygenation did not decline during exercise without compression. The recovery of tissue oxygenation after exercise was twice as slow with compression (2.5 +/- 0.6 minutes) than it was without the use of compression (1.3 +/- 0.2 minutes).

NASA Discipline Musculoskeletal↗

THz Spectroscopy and Spectroscopic Database for Astrophysics

Molecule specific astronomical observations rely on precisely determined laboratory molecular data for interpretation. The Herschel Heterodyne Instrument for Far Infrared, a suite of SOFIA instruments, and ALMA are each well placed to expose the limitations of available molecular physics data and spectral line catalogs. Herschel and SOFIA will observe in high spectral resolution over the entire far infrared range. Accurate data to previously unimagined frequencies including infrared ro-vibrational and ro-torsional bands will be required for interpretation of the observations. Planned ALMA observations with a very small beam will reveal weaker emission features requiring accurate knowledge of higher quantum numbers and additional vibrational states. Historically, laboratory spectroscopy has been at the front of submillimeter technology development, but now astronomical receivers have an enormous capability advantage. Additionally, rotational spectroscopy is a relatively mature field attracting little interest from students and funding agencies. Molecular database maintenance is tedious and difficult to justify as research. This severely limits funding opportunities even though data bases require the same level of expertise as research. We report the application of some relatively new receiver technology into a simple solid state THz spectrometer that has the performance required to collect the laboratory data required by astronomical observations. Further detail on the lack of preparation for upcoming missions by the JPL spectral line catalog is given.

THz spectrometer↗

HST-WFC3 Near-Infrared Spectroscopy of Quenched Galaxies at zeta approx 1.5 from the WISP Survey: Stellar Populations Properties

We combine Hubble Space Telescope (HST) G102 and G141 near-IR (NIR) grism spectroscopy with HST/WFC3- UVIS, HST/WFC3-IR, and Spitzer/IRAC [3.6 microns] photometry to assemble a sample of massive (log(Mstar/M solar mass) at approx 11.0) and quenched (specific star formation rate < 0.01 G/yr(exp −1) galaxies at zeta approx 1.5. Our sample of 41 galaxies is the largest with G102+G141 NIR spectroscopy for quenched sources at these redshifts. In contrast to the local universe, zeta approx 1.5 quenched galaxies in the high-mass range have a wide range of stellar population properties. We find that their spectral energy distributions (SEDs) are well fitted with exponentially decreasing star formation histories and short star formation timescales (τau less than or equal to 100 M/yr). Quenched galaxies also show a wide distribution in ages, between 1 and 4 G/yr. In the (u − r)0-versus-mass space quenched galaxies have a large spread in rest-frame color at a given mass. Most quenched galaxies populate the zeta appro. 1.5 red sequence (RS), but an important fraction of them (32%) have substantially bluer colors. Although with a large spread, we find that the quenched galaxies on the RS have older median ages (3.1 G/yr) than the quenched galaxies off the RS (1.5 G/yr). We also show that a rejuvenated SED cannot reproduce the observed stacked spectra of (the bluer) quenched galaxies off the RS. We derive the upper limit on the fraction of massive galaxies on the RS at zeta approx 1.5 to be <43%.We speculate that the young quenched galaxies off the RS are in a transition phase between vigorous star formation at zeta > 2 and the zeta approx 1.5 RS. According to their estimated ages, the time required for quenched galaxies off the RS to join their counterparts on the z approx. 1.5 RS is of the order of approx. 1G/yr.

HST WFC#↗

CubeX: A Compact X-Ray Telescope Enables Both X-Ray Fluorescence Imaging Spectroscopy and Pulsar Timing Based Navigation

This paper describes the benefits of a miniaturized X-ray telescope payload in the context of a lunar mission. The first part describes the payload in detail, the second part summarizes a small satellite mission concept that utilizes its compact form factor and performance. The CubeX instrument can be used for both X-ray fluorescence (XRF) imaging spectroscopy and X-ray pulsar timing based navigation (XNAV). Using our recent technological advances in X-ray optics and sensors, CubeX combines high angular resolution (<1 arcminutes) Miniature Wolter-I X-ray optics (MiXO) with a common focal plane consisting of high spectral resolution (<150 eV at 1 keV) CMOS X-ray sensors and a high timing resolution (< 1 usec) SDD X-ray sensor. This novel combination of the instruments enables both XRF measurements and XNAV operations without moving parts. The high angular resolution of the MiXO opens a wide range of orbital configurations for observation. Given that performance, the instrument has unprecedented small volume (~1×1×6U), mass (<6 kg), and power (<9W) requirements and opens a wide range of applications for a variety of targets and missions including NEOs and Martian moons. In this paper we illustrate one potential application for a lunar mission concept: The elemental composition of the Moon holds keys to understanding the origin and evolution of both the Moon and the Earth. X-ray fluorescence (XRF), induced either by solar X-ray flux or energetic ions, carries decisive signatures of surface elemental composition. X-ray observations, therefore, give a unique, powerful diagnostic tool for remotely determining elemental abundances including major rock forming elements such as Mg, Al, Na, Si, Fe, and Ca. Through high-resolution XRF imaging spectroscopy, CubeX searches for small patches of elusive lower crust and mantle material excavated within and around impact craters. CubeX identifies regional compositional variations and allows straightforward comparison of elemental distributions with the surface topography from LRO and the gravity data from GRAIL. The elemental compositions of the lower crust and the mantle are sensitive to the conditions of the giant impact which led to the Moon's formation and the subsequent lunar magma ocean (LMO), and thus they are key missing pieces in understanding the formation and early evolution of the Moon. In between XRF observations, CubeX also leverages the technology of high resolution X-ray imaging and time series measurements to conduct XNAV operations and evaluate their performance. Deep space navigation is a critical issue for small planetary missions. XNAV can enable low-cost autonomous deep-space navigation, and has the potential to greatly assist, or even outperform, NASA's Deep Space Network (DSN) or ESA's European Space Tracking (ESTRACK). CubeX is designed to perform sequential observations of 3-4 millisecond pulsars (MSPs) to solve the spacecraft trajectory for absolute navigation, and explore the remote sensing capability of XNAV. In the presented mission concept, the Moon's relative proximity enables a straightforward evaluation of the XNAV performance through DSN.

x-ray spectroscopy↗

Reduction of Raman Spectroscopy Data for H2-CO2-Air Tubular Flame Measurements

An approach of reducing spontaneous Raman spectroscopy data, based on the matrix inversion method which logically removes undesired sources of the Raman scattering signals including cross-talk due to the signals from other species, is discussed. The approach contains extensive calibration of temperature-dependent system response. The Raman spectra of several cold and hot calibration flames and their resulting calibration matrix are elaborated. The structure of H2-CO2-air tubular flames, in terms of major species (CO2, O2, N2, H2O, and H2) concentrations and temperature, was successfully measured with the optical technique. The Raman spectra data used in this study are taken from a uniquely designed experimental apparatus – a tubular burner and Raman spectroscopy system at Vanderbilt University. The characteristic uncertainties for chemical species are approximately ±2% by mole fraction for hot products and ±0.5% for room temperature reactants. The approach described here for hydrogen/air tubular flames may be adapted to hydrocarbon/air tubular flames when other necessary major species, for example, CH4 and CO for methane/air tubular flame, are considered in the whole process.

Raman Spectroscopy↗

The Next Frontier for Remote Sensing of Freshwater HABS: Utilizing Imaging Spectroscopy Data to Identify Cyanobacteria Bloom Types

Cyanobacteria Harmful Algal Blooms (HABs) and their associated toxicity are a concern for inland waters. Due to the extensive spatial coverage and frequent data availability of satellite-based sensors, multi-spectral remote sensing tools have demonstrated utility for monitoring, understanding, and managing these blooms. The next frontier is utilizing high spectral resolution imaging spectroscopy data, such as from NASA’s upcoming PACE, GLIMR, and SBG missions planned for this decade, which allow for the development of more sophisticated cyanobacteria detection algorithms. We evaluate the performance of cyanobacteria genera differentiation algorithms using precursor datasets in support of these upcoming hyperspectral missions. In situ measurements of lake optical, biological, chemical, and physical properties are used to characterize cyanobacteria blooms in hypereutrophic Clear Lake, CA, USA, which supports large, diverse algal and cyanobacteria populations. Data collection occurred during 12 field events in 2021-2022 across all seasons. Three field events were conducted concurrently with hyperspectral data acquisitions from the DESIS sensor on the International Space Station. The results of this study will support the development of future tools utilizing satellite-based imaging spectroscopy data to identify the cyanobacteria genera present in a bloom, and thus the potential for cyanotoxin production. This outcome – the ability to quickly characterize a cyanobacteria bloom at a low cost – will have enormous benefits for public health.

remote sensing↗

Infrared absorption spectroscopy of dynamically compressed water

Streaked visible spectroscopy is well established in dynamic compression research. Infrared measurements remain problematic, however, due to the diminishing sensitivity of streak camera photocathodes beyond 800 nm. Time-stretch techniques offer an alternative method for probing infrared features during single-event experiments. This paper discusses the development of a time-stretch spectroscopy diagnostic using dispersed supercontinuum laser pulses. The technique is applied to near-infrared measurements of liquid water during multiple shock compression.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capacitance Transients, Photoconductive Decay, and Impedance Spectroscopy on 19% to 22% Efficient Silicon Solar Cells

High efficiency silicon solar cells are characterized using current-voltage curves, electroluminescence imaging, impedance spectroscopy, capacitance transients, microwave photoconductive decay, and time-resolved photoluminescence imaging. The sample set is composed of cells from different manufacturers and includes an n-type silicon heterojunction (SHJ), an n-type passivated emitter rear totally diffused (PERT), and five different p-type passivated emitter rear contact (PERC) cells. Carrier lifetimes, both photoconductivity and photoluminescence, are measured co-located with the light excitation pulse and within the cell but away from the light spot. Luminescence intensity and excess carrier lifetimes correlate to cell voltage. The capacitance transient time constants correlate to the capacitance values extracted from impedance spectroscopy.

capacitance↗

Xenon Detection Using Double-Pulse Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy has been proposed as a diagnostic tool for fuel failure monitoring in helium-cooled fast reactor designs. Here, we show preliminary results which indicate that using double-pulse laser induced breakdown spectroscopy, a sub-ppm sensitivity for xenon in a helium ambient can be achieved. We additionally propose future studies which could help elucidate the mechanisms which lead to the observed signal enhancement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Toward the Development of Molten Salt Reactor Diagnostics based on Resonantly Enhanced Laser Spectroscopy

One emerging concern within the safeguards community is how to best ensure compliance with nuclear security regulations within molten salt reactor (MSR) facilities. This problem is nontrivial as molten salts used for fuel or coolant are highly corrosive, chemically complex, and inherently require high operational temperatures. Laser spectroscopy methods such as laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) have previously been suggested for molten salt diagnostics due to their compatibility with liquid phase samples and potential for in-situ measurements [1]. In the former, the laser is used to ionize the sample, allowing for the characteristic light from electronic de-excitation as the resultant plasma cools to be used for material characterization. In the latter, a tunable light source is set be resonant with a specific transition, resulting in element specific excitation and the emission of fluorescence light. In our previous work [2], we demonstrated that LIF could be used for the detection of fission fragments such as Nd in solution through the separation of laser scatter and fluorescence within the time domain. Here, we present progress towards two alternate measurement schemes: LIF measurements based on spectroscopic discrimination of fluorescence emissions and resonant LIBS measurements that induce plasma using a light source set to the resonant frequency of a specific electronic transition. Both methods aim to exploit resonant excitation methods to enhance the emitted signal. The studies may provide routes for element-specific detection of constituents within complicated matrices and a means to better understand the chemical behavior of lanthanides and actinides relevant to MSRs.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Remote quantification of Cm(III) and HNO 3 by fluorescence spectroscopy and chemometrics

A unique approach to remotely quantify Cm(III) (0–100 µg mL −1 ) in HNO 3 (1–12 M) using steady-state laser fluorescence spectroscopy and multivariate regression models was developed. Photoluminescence is amenable to remote measurements using fiber-optic cables and is sensitive to numerous lanthanide and actinide species. In-line measurements can provide feedback to support complex processing in harsh environments (e.g., hot cells) to help guide and optimize radiochemical separations. In this work, Cm(III) spectra were acquired remotely in a glove box as a function of HNO 3 concentration to better understand spectral characteristics and evaluate the utility of multivariate regression models in this system. Furthermore, the Cm(III) fluorescence peak shape, width, position, and intensity changed significantly as a function of HNO 3 concentration, likely because of the displacement of emission quenching inner-sphere water molecules and complexation with nitrate ions. Despite significant covariance and nonlinearity in the data, a D-optimal design strategy successfully minimized training set sample size and was used to build effective partial least squares regression models for Cm(III) and HNO 3 concentrations without a priori knowledge of solution conditions. Chemometrics for modeling complex fluorescence spectra are promising and may find widespread applicability for online analysis in numerous chemical systems found in the nuclear field.

Actinide↗

Laser-Plasma Spectroscopy of Hydroxyl with Applications

This article discusses laser-induced laboratory-air plasma measurements and analysis of hydroxyl (OH) ultraviolet spectra. The computations of the OH spectra utilize line strength data that were developed previously and that are now communicated for the first time. The line strengths have been utilized extensively in interpretation of recorded molecular emission spectra and have been well-tested in laser-induced fluorescence applications for the purpose of temperature inferences from recorded data. Moreover, new experiments with Q-switched laser pulses illustrate occurrence of molecular recombination spectra for time delays of the order of several dozen of microseconds after plasma initiation. The OH signals occur due to the natural humidity in laboratory air. Centrifugal stretching of the Franck-Condon factors and r-centroids are included in the process of determining the line strengths that are communicated as a Supplementary File. Laser spectroscopy applications of detailed OH computations include laser-induced plasma and combustion analyses, to name but two applications. This work also includes literature references that address various diagnosis applications.

47 OTHER INSTRUMENTATION↗

Terahertz time-domain spectroscopy imaging of pancreatic ductal adenocarcinoma tissues

Pancreatic ductal adenocarcinoma (PDAC) ranks among the malignancies with the highest fatality and morbidity rates. This is predominantly attributable to an absence of understanding the intricate and diverse microenvironment of the tumor. We use terahertz time-domain spectroscopy (THz-TDS) imaging in transmission geometry to probe ex-vivo the heterogenous microenvironment of the genetically modified murine PDAC tissue that closely resembles the PDAC heterogeneity in human malignancy. We introduced a maximum a-posteriori probability estimation algorithm to objectively the tumor’s heterogenous microenvironment using the average values of refractive index and absorption coefficient within the useable terahertz bandwidth as imaging markers. Furthermore, direct comparison of stained histopathologic images and the refractive index and the absorption coefficient high-resolution, two dimensional maps of the same PDAC samples confirms the high potential of the THz-TDS method for tumor tissue characterization.

absorption↗

Identifying the Signatures of Intermolecular Interactions in Blends of PM6 with Y6 and N4 Using Absorption Spectroscopy

Abstract In organic solar cells, the resulting device efficiency depends strongly on the local morphology and intermolecular interactions of the blend film. Optical spectroscopy was used to identify the spectral signatures of interacting chromophores in blend films of the donor polymer PM6 with two state‐of‐the‐art nonfullerene acceptors, Y6 and N4, which differ merely in the branching point of the side chain. From temperature‐dependent absorption and luminescence spectroscopy in solution, it is inferred that both acceptor materials form two types of aggregates that differ in their interaction energy. Y6 forms an aggregate with a predominant J‐type character in solution, while for N4 molecules the interaction is predominantly in a H‐like manner in solution and freshly spin‐cast film, yet the molecules reorient with respect to each other with time or thermal annealing to adopt a more J‐type interaction. The different aggregation behavior of the acceptor materials is also reflected in the blend films and accounts for the different solar cell efficiencies reported with the two blends.

Kroh, Daniel↗

Cryogenic Correlative Single‐Particle Photoluminescence Spectroscopy and Electron Tomography for Investigation of Nanomaterials

Abstract Cryogenic single‐particle photoluminescence (PL) spectroscopy has been used with great success to directly observe the heterogeneous photophysical states present in a population of luminescent particles. Cryogenic electron tomography provides complementary nanometer scale structural information to PL spectroscopy, but the two techniques have not been correlated due to technical challenges. Here, we present a method for correlating single‐particle information from these two powerful microscopy modalities. We simultaneously observe PL brightness, emission spectrum, and in‐plane excitation dipole orientation of CdSSe/ZnS quantum dots suspended in vitreous ice. Stable and fluctuating emitters were observed, as well as a surprising splitting of the PL spectrum into two bands with an average energy separation of 80 meV. In some cases, the onset of the splitting corresponded to changes in the in‐plane excitation dipole orientation. These dynamics were assigned to structures of individual quantum dots and the excitation dipoles were visualized in the context of structural features.

Dahlberg, Peter D.↗

Noninvasive Near‐Field Spectroscopy of Single Subwavelength Complementary Resonators

Abstract Subwavelength metallic resonators provide a route to achieving strong light–matter coupling by means of tight confinement of resonant electromagnetic fields. Investigation of such resonators however often presents experimental difficulties, particularly at terahertz (THz) frequencies. A single subwavelength resonator interacts weakly with THz beams, making it difficult to probe it using far‐field methods, whereas arrays of resonators exhibit inter‐resonator coupling, which affect the resonator spectral signature and field confinement. Here, traditional far‐field THz spectroscopy is systematically compared with aperture‐type THz near‐field microscopy for investigating complementary THz resonators. While the far‐field method proves impractical for measuring single resonators, the near‐field technique gives high signal‐to‐noise spectral information, only achievable in the far‐field with resonator arrays. At the same time, the near‐field technique allows to analyze single resonators without significant interaction with the near‐field probe. Furthermore, the near‐field technique allows highly confined fields and surface waves to be mapped in space and time. This information gives invaluable insight into spectral response in resonator arrays. This near‐field microscopy and spectroscopy method enables investigations of strong light–matter coupling at THz frequencies in the single‐resonator regime.

Hale, Lucy L.↗

Exploring Charged Defects in Ferroelectrics by the Switching Spectroscopy Piezoresponse Force Microscopy

Monitoring the charged defect concentration at the nanoscale is of critical importance for both the fundamental science and applications of ferroelectrics. However, up-to-date, high-resolution study methods for the investigation of structural defects, such as transmission electron microscopy, X-ray tomography, etc., are expensive and demand complicated sample preparation. Here, with an example of the lanthanum-doped bismuth ferrite ceramics, a novel method is proposed based on the switching spectroscopy piezoresponse force microscopy (SSPFM) that allows probing the electric potential from buried subsurface charged defects in the ferroelectric materials with a nanometer-scale spatial resolution. When compared with the composition-sensitive methods, such as neutron diffraction, X-ray photoelectron spectroscopy, and local time-of-flight secondary ion mass spectrometry, the SSPFM sensitivity to the variation of the electric potential from the charged defects is shown to be equivalent to less than 0.3 at% of the defect concentration. Additionally, the possibility to locally evaluate dynamics of the polarization screening caused by the charged defects is demonstrated, which is of significant interest for further understanding defect-mediated processes in ferroelectrics.

42 ENGINEERING↗