Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Compact folded metasurface spectrometer

Abstract An optical design space that can highly benefit from the recent developments in metasurfaces is the folded optics architecture where light is confined between reflective surfaces, and the wavefront is controlled at the reflective interfaces. In this manuscript, we introduce the concept of folded metasurface optics by demonstrating a compact spectrometer made from a 1-mm-thick glass slab with a volume of 7 cubic millimeters. The spectrometer has a resolution of ~1.2 nm, resolving more than 80 spectral points from 760 to 860 nm. The device is composed of three reflective dielectric metasurfaces, all fabricated in a single lithographic step on one side of a substrate, which simultaneously acts as the propagation space for light. The folded metasystem design can be applied to many optical systems, such as optical signal processors, interferometers, hyperspectral imagers, and computational optical systems, significantly reducing their sizes and increasing their mechanical robustness and potential for integration.

47 OTHER INSTRUMENTATION↗

Sample changers for direct geometry neutron chopper spectrometers

The advent of higher flux neutron sources has made the use of sample changers appropriate across the instrument suites at neutron scattering facilities. We examine the efficiency, design, and operation of two sample changers used at the thermal chopper spectrometers at the Spallation Neutron Source. We also present case studies of sample holders designed to accommodate multiple single crystal or powder samples for the Cold Neutron Chopper Spectrometer at the Spallation Neutron Source. [This manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).]

Stone, Matthew B. [Oak Ridge National Laboratory (↗

Tritium targets for use in solenoidal spectrometers

Nucleon adding and removing reactions are an ideal probe to study the single-particle foundations of nuclear structure. For experiments far away from the valley of stability, one needs to use radioactive beams in inverse kinematics. To maintain excellent resolution, solenoidal spectrometers like HELIOS at Argonne National Laboratory (ANL), ISS at CERN or SOLARIS at the Facility for Rare Isotope Beams (FRIB) are used. Typically, deuterated plastic foils are the targets of choice. Depending on the energy deposited, these targets might degrade quickly in beam. The potential of using tritium-implanted targets in conjunction with the solenoidal spectrometers was realized for access to even more exotic nuclei with outstanding resolving power. While no tritiated polyethylene is commercially available at the moment, tritium-containing titanium targets have been produced in the past. Unfortunately the loading fraction of tritium for the latter was often very low and not reproducible. The progress in the production of tritium-containing targets is presented, including the characterization of the foils.

Müller-Gatermann, Claus↗

A threshold photoelectron-photoion coincidence spectrometer with double velocity imaging using synchrotron radiation

A novel threshold photoelectron-photoion coincidence (TPEPICO) imaging spectrometer at the U14-A beamline of the Hefei National Synchrotron Radiation Laboratory is presented. A set of open electron and ion lenses are utilized to map velocity imaging of photoelectrons and photoions simultaneously, in which a repelling electric field using an extra lens is applied to magnify images of photoelectrons instead of traditional accelerating electric field in order to suppress the contribution of energetic electrons in the threshold photoelectron spectroscopy (TPES) and the mass-selected TPEPICO spectroscopy. The typical energy resolution of TPES is measured to be 9 meV (full width at half maximum), as shown on the {sup 2}P{sub 1/2} ionization of argon. The measured mass resolving power for the present TPEPICO imaging spectrometer is above 900 of M/{Delta}M. Subsequently as a benchmark, oxygen molecule is photoionized by monochromatic synchrotron radiation at 20.298 eV and dissociates to an oxygen atomic ion and a neutral oxygen atom, and the translation energy distribution of oxygen atomic ion is measured by the time-sliced imaging based on mass-selected TPEPICO experiment. The kinetic energy resolution of the present ion velocity imaging is better than 3% of {Delta}E/E.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable TXRF Spectrometer with 10{sup -11}g Detection Limit and Portable XRF Spectromicroscope with Sub-mm Spatial Resolution

A portable total reflection X-ray fluorescence (TXRF) spectrometer that we have developed is applied to trace elemental analysis of water solutions. Although a 5 W X-ray tube is used in the portable TXRF spectrometer, detection limits of several ppb are achieved for 3d transition metal elements and trace elements in a leaching solution of soils, a leaching solution of solder, and alcoholic beverages are detected. Portable X-ray fluorescence (XRF) spectromicroscopes with a 1 W X-ray tube and an 8 W X-ray tube are also presented. Using the portable XRF spectromicroscope with the 1 W X-ray tube, 93 ppm of Cr is detected with an about 700 {mu}m spatial resolution. Spatially resolved elemental analysis of a mug painted with blue, red, green, and white is performed using the two portable spectromicroscopes, and the difference in elemental composition at each paint is detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigations of 2β decay measured by low background HPGe spectrometer OBELIX

A low background high sensitive HPGe spectrometer OBELIX was installed at the Modane Underground Laboratory (LSM, France, 4800 m w.e.). The detector was designed to measure a contamination of enriched isotopes and radio-impurities in construction materials, to investigate rare nuclear processes such as resonance neutrinoless double electron capture and two-neutrino double beta decay to excited states of daughter nuclei. Spectrometer sensitivity, contamination of NEMO-3 sources and results of 2ν2β{sup −} decay of {sup 100}Mo to the 0{sup +} (1130 keV) and 2{sup +} (540 keV) excited states as well as future plans for OBELIX detector are given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A stretch/compress scheme for a high temporal resolution detector for the magnetic recoil spectrometer time (MRSt)

Here we present a time-resolved detector concept for the magnetic recoil spectrometer for time-resolved measurements of the NIF neutron spectrum. The measurement is challenging due to the time spreading of the recoil protons (or deuterons) as they transit an energy dispersing magnet system. Ions arrive at the focal plane of the magnetic spectrometer over an interval of tens of nanoseconds. We seek to measure the time-resolved neutron spectrum with 20 ps precision by manipulating an electron signal derived from the ions. A stretch-compress scheme is employed to remove transit time skewing while simultaneously reducing the bandwidth requirements for signal recording. Simulation results are presented along with design concepts for structures capable of establishing the required electromagnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the microcalorimeter spectrometer on-board the Hitomi (Astro-H) observatory (invited)

The Hitomi Soft X-ray Spectrometer (SXS) was a pioneering non-dispersive imaging x-ray spectrometer with 5 eV FWHM energy resolution, consisting of an array of 36 silicon-thermistor microcalorimeters at the focus of a high-throughput soft x-ray telescope. Here, the instrument enabled astrophysical plasma diagnostics in the 0.3–12 keV band. We introduce the SXS calibration strategy and corresponding ground calibration measurements that took place from 2012–2015, including both the characterization of the microcalorimeter array and measurements of the x-ray transmission of optical blocking filters.

47 OTHER INSTRUMENTATION↗

Calibration and characterization of a highly efficient spectrometer in von Hamos geometry for 7-10 keV x-rays

Here, we have built an absolutely calibrated, highly efficient, Bragg crystal spectrometer in von Hamos geometry. This zinc von Hamos spectrometer uses a crystal made from highly oriented pyrolytic graphite that is cylindrically bent along the non-dispersive axis. It is tuned to measure x-ray spectra in the 7–10 keV range and has been designed to be used on a Ten Inch Manipulator for the Omega and OmegaEP target chambers at the Laboratory for Laser Energetics in Rochester, USA. Significant shielding strategies and fluorescence mitigation have been implemented in addition to an imaging plate detector making it well suited for experiments in high-intensity environments. Here we present the design and absolute calibration as well as mosaicity and integrated reflectivity measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near shot-noise limited time-resolved circular dichroism pump-probe spectrometer

We describe an optical near shot-noise limited time-resolved circular dichroism (TRCD) pump-probe spectrometer capable of reliably measuring circular dichroism signals in the order of $\mu$deg with nanosecond time resolution. Such sensitivity is achieved through a modification of existing TRCD designs and introduction of a new data processing protocol that eliminates approximations that have caused substantial nonlinearities in past measurements and allows the measurement of absorption and circular dichroism transients simultaneously with a single pump pulse. The exceptional signal-to-noise ratio of the described setup makes the TRCD technique applicable to a large range of non-biological and biological systems. Finally, the spectrometer was used to record, for the first time, weak TRCD kinetics associated with the triplet state energy transfer in the photosynthetic Fenna-Matthews-Olson antenna pigment-protein complex.

47 OTHER INSTRUMENTATION↗

Measurement of apparent ion temperature using the magnetic recoil spectrometer at the OMEGA laser facility

The Magnetic Recoil neutron Spectrometer (MRS) at the OMEGA laser facility has been routinely used to measure deuterium-tritium (DT) yield and areal density in cryogenically layered implosions since 2008. Recently, operation of the OMEGA MRS in higher-resolution mode with a new smaller, thinner (4 cm 2 , 57 μm thick) CD 2 conversion foil has also enabled inference of the apparent DT ion temperature (T ion ) from MRS data. MRS-inferred T ion compares well with T ion as measured using neutron time-of-flight spectrometers, which is important as it demonstrates good understanding of the very different systematics associated with the two independent measurements. The MRS resolution in this configuration, $ΔE_{MRS}$ = 0.91 MeV FWHM, is still higher than that required for a high-precision T ion measurement. We show herein how fielding a smaller foil closer to the target chamber center and redesigning the MRS detector array could bring the resolution to $ΔE_{MRS}$ = 0.45 MeV, reducing the systematic T ion uncertainty by more than a factor of 4.

47 OTHER INSTRUMENTATION↗

Instrumentation for the upgrade to the JET core charge-exchange spectrometers

Charge-exchange spectroscopy on JET has become particularly challenging with the introduction of the ITER-like wall. The line intensities are weaker and contaminated by many nuisance lines. We have therefore upgraded the instrumentation to improve throughput and allow the simultaneous measurement of impurity and fuel-ion charge exchange by splitting the light between two pairs of imaging spectrometers using dichroic beam splitters. Imaging instruments allow us to stack 11 × 1 mm diameter fibres on the entrance slits without cross talk. CCD cameras were chosen to have 512 × 512 pixels to allow frame transfer times <0.2 ms which with minimum exposure times of 5 ms give tolerable smearing even without a chopper. The image plane is optically demagnified 2:1 to match the sensor size of these cameras. Because the image plane of the spectrometer is tilted, the CCD must also be tilted to maintain focus over the spectrum (Scheimpflug condition). To avoid transverse keystoning (causing the vertical height of the spectra to change across the sensor), the configuration is furthermore designed to be telecentric by a suitable choice of the lens separation. The lens configuration is built almost entirely from commercial off-the-shelf components, which allowed it to be assembled and aligned relatively rapidly to meet the deadline for in-vessel calibration in the JET shutdown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Warm Electron Beam Ion Trap (WEBIT): An instrument for ground calibration of space-borne x-ray spectrometers

The warm electron beam ion trap (WEBIT) at Lawrence Livermore National Laboratory is being developed as a pre-launch, ground calibration source for space-borne, high-throughput, high-resolution x-ray spectrometers, such as the x-ray imaging and spectroscopy mission Resolve quantum calorimeter. Historically, calibration sources for calorimeter spectrometers have relied on characteristic line emission from x-ray tubes, fluorescing metals, and radioactive sources. The WEBIT, by contrast, relies on emission from x-ray transitions in highly charged ions, for example, hydrogen-like and helium-like ions, whose energies are well known and whose line shapes are relatively simple. The WEBIT can create astrophysically relevant ions whose x-ray emission falls in the 0.3-12 keV science bandpass of Resolve and has a portable design advantageous for a calibration source. The WEBIT will be used to help calibrate Resolve’s instrumental line shape and gain scale as a function of various operational parameters during both detector subsystem level testing and instrumental level testing.

47 OTHER INSTRUMENTATION↗

A Coincidence Velocity Map Imaging Spectrometer for Ions and High-Energy Electrons to Study Inner-Shell Photoionization of Gas-Phase Molecules

We report on the design and performance of a double-sided coincidence velocity map imaging spectrometer optimized for electron-ion and ion-ion coincidence experiments studying inner-shell photoionization of gas-phase molecules with soft X-ray synchrotron radiation. The apparatus employs two microchannel plate detectors equipped with delay-line anodes for coincident, time- and position-resolved detection of photoelectrons and Auger electrons with kinetic energies up to 300 eV on one side of the spectrometer and photoions up to 25 eV per unit charge on the opposite side. We demonstrate its capabilities by measuring valence photoelectrons and ion spectra of neon and nitrogen and by studying channel-resolved photoelectron and Auger spectra along with fragment-ion momentum correlations for chlorine 2 p inner-shell ionization of cis - and trans -1,2-dichloroethene.

74 ATOMIC AND MOLECULAR PHYSICS↗

A neutron recoil-spectrometer for measuring yield and determining liner areal densities at the Z facility

For this study, a proof-of-principle CR-39 based neutron-recoil-spectrometer was built and fielded on the Z facility. Data from this experiment match indium activation yields within a factor of 2 using simplified instrument response function (IRF) models. The data also demonstrates the need for neutron shielding in order to infer liner areal densities. A new shielded design has been developed. The spectrometer is expected to achieve signal-to-background greater than 2 for the down-scattered neutron signal and greater than 30 for the primary signal.

47 OTHER INSTRUMENTATION↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

CHESS: The future direct geometry spectrometer at the second target station

CHESS, chopper spectrometer examining small samples, is a planned direct geometry neutron chopper spectrometer designed to detect and analyze weak signals intrinsic to small cross sections (e.g., small mass, small magnetic moments, or neutron absorbing materials) in powders, liquids, and crystals. CHESS is optimized to enable transformative investigations of quantum materials, spin liquids, thermoelectrics, battery materials, and liquids. The broad dynamic range of the instrument is also well suited to study relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of the Second Target Station at the Spallation Neutron Source enables the use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single measurement. Furthermore, the high flux grants an enhanced capability for polarization analysis. This enables the separation of nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials over a large range of energy and momentum transfer. This paper presents optimizations and technical solutions to address the key requirements envisioned in the science case and the anticipated uses of this instrument.

47 OTHER INSTRUMENTATION↗