Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Impact-Seismic Investigations of the InSight Mission

Impact investigations will be an important aspect of the InSight mission. One of the scientific goals of the mission is a measurement of the current impact rate at Mars. Impacts will additionally inform the major goal of investigating the interior structure of Mars. In this paper, we review the current state of knowledge about seismic signals from impacts on the Earth, Moon, and laboratory experiments. We describe the generalized physical models that can be used to explain these signals. A discussion of the appropriate source time function for impacts is presented, along with spectral characteristics including the cutoff frequency and its dependence on impact momentum. Estimates of the seismic efficiency (ratio between seismic and impact energies) vary widely. Our preferred value for the seismic efficiency at Mars is 5 × 10−4, which we recommend using until we can measure it during the InSight mission, when seismic moments are not used directly. Effects of the material properties at the impact point and at the seismometer location are considered. We also discuss the processes by which airbursts and acoustic waves emanate from bolides, and the feasibility of detecting such signals. We then consider the case of impacts on Mars. A review is given of the current knowledge of present-day cratering on Mars: the current impact rate, characteristics of those impactors such as velocity and directions, and the morphologies of the craters those impactors create. Several methods of scaling crater size to impact energy are presented. The Martian atmosphere, although thin, will cause fragmentation of impactors, with implications for the resulting seismic signals. We also benchmark several different seismic modeling codes to be used in analysis of impact detections, and those codes are used to explore the seismic amplitude of impactinduced signals as a function of distance from the impact site. We predict a measurement of the current impact flux will be possible within the timeframe of the prime mission (one Mars year) with the detection of ∼ a few to several tens of impacts. However, the error bars on these predictions are large. Specific to the InSight mission, we list discriminators of seismic signals from impacts that will be used to distinguish them from marsquakes. We describe the role of the InSight Impacts Science Theme Group during mission operations, including a plan for possible night-time meteor imaging. The impacts detected by these methods during the InSight mission will be used to improve interior structure models, measure the seismic efficiency, and calculate the size frequency distribution of current impacts.

Ingrid Daubar↗

Damage Assessment of Creep Tested and Thermally Aged Metallic Alloys Using Acousto-Ultrasonics

In recent years emphasis has been placed on the early detection of material changes experienced in turbine powerplant components. During the scheduled overhaul of a turbine, the current techniques of examination of various hot section components aim to find flaws such as cracks, wear, and erosion, as well as excessive deformations. Thus far, these localized damage modes have been detected with satisfactory results. However, the techniques used to find these flaws provide no information on life until the flaws are actually detected. Major improvements in damage assessment, safety, as well as more accurate life prediction could be achieved if nondestructive evaluation (NDE) techniques could be utilized to sense material changes that occur prior to the localized defects mentioned. Because of elevated temperatures and excessive stresses, turbine components may experience creep behavior. As a result, it is desirable to monitor and access the current condition of such components. Research at the NASA Glenn Research Center involves developing and utilizing an NDE technique that discloses distributed material changes that occur prior to the localized damage detected by the current methods of inspection. In a recent study, creep processes in a nickel-base alloy were the life-limiting condition of interest, and the NDE technique was acousto-ultrasonics (AU). AU is an NDE technique that utilizes two ultrasonic transducers to interrogate the condition of a test specimen. The sending transducer introduces an ultrasonic pulse at a point on the surface of the specimen while a receiving transducer detects the signal after it has passed through the material. The goal of the method is to correlate certain parameters of the detected waveform to characteristics of the material between the two transducers. Here, the waveform parameter of interest is the attenuation due to internal damping for which information is being garnered from the frequency domain. The parameters utilized to indirectly quantify the attenuation are the ultrasonic decay rate as well as various moments of the frequency power spectrum. A new, user-friendly, graphical interface AU system was developed at NASA Glenn. This system is an all-inclusive, multifunction system that controls the sending and receiving ultrasonic transducers as well as all posttest signal analysis. The system's postprocessing software calculates the multiple parameters used to study the material of interest.

Gyekenyesi, Andrew L.↗

Biomimetic/Optical Sensors for Detecting Bacterial Species

Biomimetic/optical sensors have been proposed as means of real-time detection of bacteria in liquid samples through real-time detection of compounds secreted by the bacteria. Bacterial species of interest would be identified through detection of signaling compounds unique to those species. The best-characterized examples of quorum-signaling compounds are acyl-homoserine lactones and peptides. Each compound, secreted by each bacterium of an affected species, serves as a signal to other bacteria of the same species to engage in a collective behavior when the population density of that species reaches a threshold level analogous to a quorum. A sensor according to the proposal would include a specially formulated biomimetic film, made of a molecularly imprinted polymer (MIP), that would respond optically to the signaling compound of interest. The MIP film would be integrated directly onto an opticalwaveguide- based ring resonator for optical readout. Optically, the sensor would resemble the one described in Chemical Sensors Based on Optical Ring Resonators (NPO-40601), NASA Tech Briefs, Vol. 29, No. 10 (October 2005), page 32. MIPs have been used before as molecular- recognition compounds, though not in the manner of the present proposal. Molecular imprinting is an approach to making molecularly selective cavities in a polymer matrix. These cavities function much as enzyme receptor sites: the chemical functionality and shape of a cavity in the polymer matrix cause the cavity to bind to specific molecules. An MIP matrix is made by polymerizing monomers in the presence of the compound of interest (template molecule). The polymer forms around the template. After the polymer solidifies, the template molecules are removed from the polymer matrix by decomplexing them from their binding sites and then dissolving them, leaving cavities that are matched to the template molecules in size, shape, and chemical functionality. The cavities thus become molecular-recognition sites that bind only to molecules matched to the sites; other molecules are excluded. In a sensor according to the proposal, the MIP would feature molecular recognition sites that would bind the specific signaling molecules selectively according to their size, shape, and chemical functionality (see figure). As the film took up the signaling molecules in the molecular recognition sites, the index of refraction and thickness of the film would change, causing a wavelength shift of the peak of the resonance spectrum. It has been estimated that by measuring this wavelength shift, it should be possible to detect as little as 10 picomoles of a peptide signaling compound.

Homer, Margie↗

Adaptive Thresholding and Parameter Estimation for PPM

A method of adaptive setting of a threshold level for the detection of pulses in a pulse-position modulation (PPM) free-space optical communication system has been developed. In simplified terms, it is desirable to set a threshold value high enough to greatly reduce the probability (PFA as defined below) of erroneously detecting noise as signal pulses but not so high as to greatly reduce the probability (PD as defined below) of detecting any signal pulses that may be present along with noise. In the present method, the threshold level is varied with time, in response to changing conditions in the optical-communication channel, in an effort to maintain a balance between the aforesaid competing requirements. An integral part of this adaptation scheme is a scheme for estimating key parameters of the optical-communication channel in particular, parameters that describe the fading and total attenuation in the channel, and parameters that characterize spreading of pulses by atmospheric and other effects. The method can be implemented by software processing of digitized optoelectronic-detector output, and has been tested by computational simulation. In the first stage of processing by this method, the digitized values of the detector output during noise-only time slots of received PPM symbols are averaged to obtain a background level. This background level is subtracted from the detector output in the hope of reducing or eliminating the noise component in the remaining signal. (This background level should not be confused with the detection threshold, which is computed in the last stage of processing.) Next, the remaining signal - in effect, a vector of pulse samples - is normalized by dividing it by its L1 norm (in general, the L1 norm of a vector is defined as the sum of absolute magnitudes of its orthogonal components).

Arabshahi, Payman↗

Controlling Electron-Beam-Weld Focus

Control loop measures weld-spot temperature to regulate focus current. Square-wave generator modulates current in electron-beam focus coil so that focal point is varied between points slightly above and below surface of weld. Sensor detects intensity of light emitted by weld, proportional to fourth power of temperature at hottest part of weld spot. Sensor signal is detected by chopper demodulator synchronized by square-wave generator, to determine whether average position of focal point is higher than, coincident with, or lower than optimum point; and focus coil current is adjusted accordingly.

Coate, F. M.↗

Mars Global Surveyor Ka-Band Frequency Data Analysis

The Mars Global Surveyor (MGS) spacecraft, launched on November 7, 1996, carries an experimental space-to-ground telecommunications link at Ka-band (32 GHz) along with the primary X-band (8.4 GHz) downlink. The signals are simultaneously transmitted from a 1.5-in diameter parabolic high gain antenna (HGA) on MGS and received by a beam-waveguide (BWG) R&D 34-meter antenna located in NASA's Goldstone Deep Space Network (DSN) complex near Barstow, California. The projected 5-dB link advantage of Ka-band relative to X-band was confirmed in previous reports using measurements of MGS signal strength data acquired during the first two years of the link experiment from December 1996 to December 1998. Analysis of X-band and Ka-band frequency data and difference frequency (f(sub x)-f(sub ka)/3.8) data will be presented here. On board the spacecraft, a low-power sample of the X-band downlink from the transponder is upconverted to 32 GHz, the Ka-band frequency, amplified to I-W using a Solid State Power Amplifier, and radiated from the dual X/Ka HGA. The X-band signal is amplified by one of two 25 W TWTAs. An upconverter first downconverts the 8.42 GHz X-band signal to 8 GHz and then multiplies using a X4 multiplier producing the 32 GHz Ka-band frequency. The frequency source selection is performed by an RF switch which can be commanded to select a VCO (Voltage Controlled Oscillator) or USO (Ultra-Stable Oscillator) reference. The Ka-band frequency can be either coherent with the X-band downlink reference or a hybrid combination of the USO and VCO derived frequencies. The data in this study were chosen such that the Ka-band signal is purely coherent with the X-band signal, that is the downconverter is driven by the same frequency source as the X-band downlink). The ground station used to acquire the data is DSS-13, a 34-meter BWG antenna which incorporates a series of mirrors inside beam waveguide tubes which guide the energy to a subterranean pedestal room, providing a stable environment for the feed and electronics equipment. A dichroic plate is used to reflect the X-band energy and pass the Ka-band energy to another mirror. The RF energy for each band is then focused onto a feed horn and low-noise amplifier package. After amplification and RF/IF downconversion, the IF signals are sent to the Experimental Tone Tracker (ETT), a digital phase-lock-loop receiver, which simultaneously tracks both X-band and Ka-band carrier signals. Once a signal is detected, the ETT outputs estimates of the SNR in a I -Hz bandwidth (Pc/No), baseband phase and frequency of the signals every I -sec. Between December 1996 and December 1998, the Ka-band and X-band signals from MGS were tracked on a regular basis using the ETT. The Ka-band downlink frequencies described here were referenced to the spacecraft's on-board USO which was also the X-band frequency reference (f(sub ka)= 3.8 f(sub x)). The ETT estimates of baseband phase at I -second sampled time tags were converted to sky frequency estimates. Frequency residuals were then generated for each band by removing a model frequency from each observable frequency at each time tag. The model included Doppler and other effects derived from spacecraft trajectory files obtained from the MGS Navigation Team. A simple troposphere correction was applied to the data. In addition to residuals, the USO frequencies emitted by the spacecraft were estimated. For several passes, the USO frequencies were determined from X-band data and from Ka-band data (referred to X-band by dividing by 3.8) and were found to be in good agreement. In addition, X-band USO frequency estimates from MGS Radio Science data acquired from operational DSN stations were available for comparison and were found to agree within the I Hz level. The remaining sub-Hertz differences were attributed to the different models and software algorithms used by MGS Radio Science and KaBLE-11. A summary of the results of a linear fit of the USO frequency versus time (day of year) is presented in Table I for an initial segment of passes.

Morabito, D.↗

Tensor Decomposition Analysis for UAV Anomaly Detection

Vibrational anomalies can provide valuable insights into the health status of an unmanned aerial vehicle, potentially indicating system degradation including propeller, motor, or sensor damage, as well as environmental anomalies such as strong wind gusts and turbulence. However, many causes for vibrational anomalies are not related to vehicle health, such as sharp shifts in velocity or direction of flight. Thus, depending strictly on vibration signals to detect anomalies can result in false positives for failures. Hence, it is important to include additional telemetries in detecting and diagnosing in-flight anomalies. This paper considers an approach to anomaly detection based on tensor decompositions that incorporates information from vibration signals, as well as additional flight data such as velocity, current draw, voltage drop, and attitude. Using experimental flight data collected by the University of Notre Dame, we construct third-order tensors then apply the CANDECOMP/PARAFAC decomposition to identify trends within each flight and classify flights as nominal or anomalous.

unmanned aviation↗

Ulysses observations of auroral hiss at high Jovian latitudes

During the Ulysses flyby of Jupiter, a whistler-mode emission was periodically detected by the unified Radio and Plasma wave (URAP) experiment during intervals when the spacecraft extended to high magnetic latitudes. The signal was detected between the local electron plasma frequency and lower hybrid resonance and appears as a funnel-shaped structure on frequency-versus-time spectrograms; these characteristics are very reminiscent of whistler-mode auroral hiss observed at high latitudes at Earth. Ray tracing of the emission occurrences suggests the emission source is on magnetic field lines extending out to at least 65 R(sub J). This location associates the emission with the boundary between open and closed field lines -- not the Io torus. The emission radiates about 10(exp 7) W of power. Consequently, the auroral input power derived from the solar wind to drive the emission is believed to be 10(exp 10-12) W (or about 1% of the energy associated with Io torus electrical processes).

Farrell, W. M.↗

Development of an airborne laser bathymeter

An airborne laser depth sounding system was built and taken through a complete series of field tests. Two green laser sources were tried: a pulsed neon laser at 540 nm and a frequency-doubled Nd:YAG transmitter at 532 nm. To obtain a depth resolution of better than 20 cm, the pulses had a duration of 5 to 7 nanoseconds and could be fired up to at rates of 50 pulses per second. In the receiver, the signal was detected by a photomultiplier tube connected to a 28 cm diameter Cassegrainian telescope that was aimed vertically downward. Oscilloscopic traces of the signal reflected from the sea surface and the ocean floor could either be recorded by a movie camera on 35 mm film or digitized into 500 discrete channels of information and stored on magnetic tape, from which depth information could be extracted. An aerial color movie camera recorded the geographic footprint while a boat crew of oceanographers measured depth and other relevant water parameters. About two hundred hours of flight time on the NASA C-54 airplane in the area of Chincoteague, Virginia, the Chesapeake Bay, and in Key West, Florida, have yielded information on the actual operating conditions of such a system and helped to optimize the design. One can predict the maximum depth attainable in a mission by measuring the effective attenuation coefficient in flight. This quantity is four times smaller than the usual narrow beam attenuation coefficient. Several square miles of a varied underwater landscape were also mapped.

Kim, H., H.↗

Vibration detection of component operability

In order to prevent catastrophic failure and eliminate unnecessary periodic maintenance in the Space Shuttle Orbiter dynamic components, instrumentation for detecting incipient failure in these components is required. This study investigated the utilization of vibrational phenomena as one of the principal physical parameters on which to base the design of this instrumentation. Baseline vibration data was collected from three aircraft type fans and two aircraft type pumps over a frequency range from a few Hertz to greater than 300 kHz. The baseline data included spectrum analysis of the vibration and detected carrier signals, as well as several non-spectrum parameters. Several defects were introduced into the five test items, and all defects were detected by at least one of the parameters with a margin of at least 2:1 over the worst case baseline.

Baird, B.↗

A photoelastic fiber optic strain gage

This paper reports on the development of a photoelastic fiber optic strain gage sensitive to transverse strain. The sensing element is made from an epoxy resin which is stress frozen to passively achieve the quadrature condition. Light, emitted from an LED operating at 820 nm, is transmitted to and from the sensing element via multimode fibers and the signal is detected using a dual channel operational photodiode/amplifier. This unique combination of optics and electronics produces a fiber optic sensor having a high signal to noise ratio which is lead-in/out insensitive. Results show that strains on the order of 1 microstrain can be measured over an 800 microstrain range and that dummy gages can be used for temperature compensation.

Su, Wei↗

Radio frequency strain monitor

A radio frequency strain monitor includes a voltage controlled oscillator for generating an oscillating signal that is input into a propagation path. The propagation path is preferably bonded to the surface of a structure to be monitored and produces a propagated signal. A phase difference between the oscillating and propagated signals is detected and maintained at a substantially constant value which is preferably a multiple of 90.degree. by changing the frequency of the oscillating signal. Any change in frequency of the oscillating signal provides an indication of strain in the structure to which the propagation path is bonded.

Heyman, Joseph S.↗

Principles of communication engineering.

Textbook on communication engineering emphasizing random processes, information and detection theory, statistical communication theory, applications, etc

COMMUNICATION THEORY↗

Polarization of the Cosmic Microwave Background: Are These Guys Serious?

The polarization of the cosmic microwave background (CMB) could contain the oldest information in the universe, dating from an inflationary epoch just after the Big Bang. Detecting this signal presents an experimental challenge, as it is both faint and hidden behind complicated foregrounds. The rewards, however, are great, as a positive detection would not only establish inflation as a physical reality but also provide a model-independent measurement of the relevant energy scale. I will present the scientific motivation behind measurements of the CMB polarization and discuss how recent experimental progress could lead to a detection in the not-very-distant future.

Kogut, Alan↗

A Possible Organic Contribution to the Low Temperature CO2 Release Seen in Mars Phoenix Thermal and Evolved Gas Analyzer Data

Two of the most important discoveries of the Phoenix Mars Lander were the discovery of approx.0.6% perchlorate [1] and 3-5% carbonate [2] in the soils at the landing site in the martian northern plains. The Thermal and Evolved Gas Analyzer (TEGA) instrument was one of the tools that made this discovery. After soil samples were delivered to TEGA and transferred into small ovens, the samples could be heated up to approx.1000 C and the gases that evolved during heating were monitored by a mass spectrometer. A CO2 signal was detected at high temperature (approx.750 C) that has been attributed to calcium carbonate decomposition. In addition to this CO2 release, a lower temperature signal was seen. This lower temperature CO2 release was postulated to be one of three things: 1) desorption of CO2, 2) decomposition of a different carbonate mineral, or 3) CO2 released due to organic combustion. Cannon et al. [3] present another novel hypothesis involving the interaction of decomposition products of a perchlorate salt and calcium carbonate.

Archer, P. D. Jr.↗

Recursive ideal observer detection of known M-ary signals in multiplicative and additive Gaussian noise.

This paper presents the derivation of the recursive algorithms necessary for real-time digital detection of M-ary known signals that are subject to independent multiplicative and additive Gaussian noises. The motivating application is minimum probability of error detection of digital data-link messages aboard civil aircraft in the earth reflection multipath environment. For each known signal, the detector contains one Kalman filter and one probability computer. The filters estimate the multipath disturbance. The estimates and the received signal drive the probability computers. Outputs of all the computers are compared in amplitude to give the signal decision. The practicality and usefulness of the detector are extensively discussed.

Painter, J. H.↗