Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCORE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Satellite and Ground System Solutions at Your Fingertips

In the summer of 1998, the blockbuster action movie Armageddon captivated audiences with a thrilling doomsday plot about a meteor the size of Texas that was racing towards the Earth. Though the premise of the movie was purely fictional, the unfortunate reality is that near-Earth asteroids such as the one portrayed in the film do exist. On December 23, 2004, NASA announced that an asteroid it anticipated to pass near the Earth on April 13, 2029, had been assigned the highest score to date on the universally used Torino Impact Hazard Scale. At first, the flyby distance for the asteroid, dubbed MN4, was uncertain and an Earth impact could not be ruled out. The odds of impact were initially believed to be 1 in 300, high enough to merit special monitoring by astronomers around the world, but were then escalated to 1 in 37 on December 27. NASA officials noted, however, that these odds should not be of public concern, since they were likely to change on a day-to-day basis as new data were received. The officials were correct in their assertion, as any chances of an impact with Earth in 2029 were completely ruled out later that same day. Integral Systems, Inc., a leading provider of satellite ground systems and the first company to offer an integrated suite of commercial-off-the-shelf software products for satellite command and control, is helping NASA keep a careful watch for any close-encountering asteroids with its tracking technology. The company supported the first NASA Discovery mission, the Near Earth Asteroid Rendezvous (NEAR) program, back in 1996, and has expanded its business by building more ground systems for a greater variety of satellites than any other company in the world. (NASA has since launched seven more Discovery missions, with the eighth lifting off earlier this year.) The experience gained from the company s participation in developing satellite command and control ground systems for the NEAR program has bolstered its flagship product line, the EPOCH Integrated Product Suite (IPS), first featured in Spinoff 1997, and led to the creation of its latest product, the Skylight Direct Broadcast Ground Terminal.

Source record↗

High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

Source record↗

The Effect of Sensory Noise Created by Compliant and Sway-Referenced Support Surfaces on Postural Stability

The purpose of the present experiment was to compare in normal human subjects the differential effects on postural stability of introducing somatosensory noise via compliant and/or sway-referenced support surfaces during quiet standing. The use of foam surfaces (two thicknesses: thin (0.95cm) and thick (7.62cm)) and sway-referenced support allowed comparison between two different types of destabilizing factors that increased ankle/foot somatosensory noise. Under some conditions neck extensions were used to increase sensory noise by deviating the vestibular system from its optimal orientation for balance control. The impact of these conditions on postural control was assessed through objective measures of instability. Thick foam and sway-referenced support conditions generated comparable instability in subjects, as measured by equilibrium score and minimum time-to-contact. However, simultaneous application of the conditions resulted in greater instability, suggesting a higher level of generated sensory noise and thus, different receptor types affected during each manipulation. Indeed, sway-referenced support generated greater anterior-posterior center-of-mass (COM) sway, while thick foam generated greater medio-lateral COM sway and velocity. Neck extension had minimal effect on postural stability until combined with simultaneous thick foam and sway-referenced support. Thin foam never generated enough sensory noise to affect postural stability even with noise added by sway-reference support or neck extension. These results provide an interesting window into the central integration of redundant sensory information and indicate the postural impact of sensory inputs is not solely based on their existence, but also their level of noise.

Forth, Katharine E.↗

Induction and quantification of gammma-H2AX foci following cx- and gamma-irradiaton

Following DNA damage the histone H2AX becomes phosphorylated and can be visualised by immunofluorescence as an indicator of DSBs in individual cells. Using a wild type hamster cell line (V79-4) exposed to either a-particles or to Co-60 gamma-rays to induce DNA DSBs at different doses (20-200OmGy), the dose dependent induction of gamma-H2AX foci were scored both manually (by eye) and using image analysis. A linearly dependence on dose was found for both radiations. The number of DSBs determined by image analysis after a post-irradiation period of 30 minutes at 37 C, is 16.6 foci/cell/Gy for alpha-irradiation and 12.2 foci/cell/Gy for gamma-irradiation; the latter being 3-4 times the levels observed by eye and comparable to gamma-radiation-induced levels of prompt DSBs more recently reported using pulse field gel electrophoresis (approx. 16 DSBs/Gy). The average size of the gamma-H2AX foci induced by alpha-irradiation (0.30 square micrometers) is approximately 1.5 times larger than those induced by gamma-irradiation (0.19 square micrometers). The timescale of induction and removal of DSBs up to 24 hours post-irradiation, was investigated with gamma-H2AX foci levels found to remain significantly higher than controls for 4 or 6 hours in gamma-irradiated samples or alpha irradiated samples, respectively. These results demonstrate that not only gamma radiation but also alpha-radiation induce phosphorylation of the H2AX histone in response to DSBs even at low doses (20mGy for gamma-rays, 1 track/cell on average for alpha-particles) and the variation in size and dephosphorylation of the induced foci is dependent on radiation quality (LET).

Leatherbarrow, E. L.↗

Convective Weather Forecast Quality Metrics for Air Traffic Management Decision-Making

Since numerical weather prediction models are unable to accurately forecast the severity and the location of the storm cells several hours into the future when compared with observation data, there has been a growing interest in probabilistic description of convective weather. The classical approach for generating uncertainty bounds consists of integrating the state equations and covariance propagation equations forward in time. This step is readily recognized as the process update step of the Kalman Filter algorithm. The second well known method, known as the Monte Carlo method, consists of generating output samples by driving the forecast algorithm with input samples selected from distributions. The statistical properties of the distributions of the output samples are then used for defining the uncertainty bounds of the output variables. This method is computationally expensive for a complex model compared to the covariance propagation method. The main advantage of the Monte Carlo method is that a complex non-linear model can be easily handled. Recently, a few different methods for probabilistic forecasting have appeared in the literature. A method for computing probability of convection in a region using forecast data is described in Ref. 5. Probability at a grid location is computed as the fraction of grid points, within a box of specified dimensions around the grid location, with forecast convection precipitation exceeding a specified threshold. The main limitation of this method is that the results are dependent on the chosen dimensions of the box. The examples presented Ref. 5 show that this process is equivalent to low-pass filtering of the forecast data with a finite support spatial filter. References 6 and 7 describe the technique for computing percentage coverage within a 92 x 92 square-kilometer box and assigning the value to the center 4 x 4 square-kilometer box. This technique is same as that described in Ref. 5. Characterizing the forecast, following the process described in Refs. 5 through 7, in terms of percentage coverage or confidence level is notionally sound compared to characterizing in terms of probabilities because the probability of the forecast being correct can only be determined using actual observations. References 5 through 7 only use the forecast data and not the observations. The method for computing the probability of detection, false alarm ratio and several forecast quality metrics (Skill Scores) using both the forecast and observation data are given in Ref. 2. This paper extends the statistical verification method in Ref. 2 to determine co-occurrence probabilities. The method consists of computing the probability that a severe weather cell (grid location) is detected in the observation data in the neighborhood of the severe weather cell in the forecast data. Probabilities of occurrence at the grid location and in its neighborhood with higher severity, and with lower severity in the observation data compared to that in the forecast data are examined. The method proposed in Refs. 5 through 7 is used for computing the probability that a certain number of cells in the neighborhood of severe weather cells in the forecast data are seen as severe weather cells in the observation data. Finally, the probability of existence of gaps in the observation data in the neighborhood of severe weather cells in forecast data is computed. Gaps are defined as openings between severe weather cells through which an aircraft can safely fly to its intended destination. The rest of the paper is organized as follows. Section II summarizes the statistical verification method described in Ref. 2. The extension of this method for computing the co-occurrence probabilities in discussed in Section HI. Numerical examples using NCWF forecast data and NCWD observation data are presented in Section III to elucidate the characteristics of the co-occurrence probabilities. This section also discusses the procedure for computing throbabilities that the severity of convection in the observation data will be higher or lower in the neighborhood of grid locations compared to that indicated at the grid locations in the forecast data. The probability of coverage of neighborhood grid cells is also described via examples in this section. Section IV discusses the gap detection algorithm and presents a numerical example to illustrate the method. The locations of the detected gaps in the observation data are used along with the locations of convective weather cells in the forecast data to determine the probability of existence of gaps in the neighborhood of these cells. Finally, the paper is concluded in Section V.

Chatterji, Gano B.↗

Metrics for Linear Kinematic Features in Sea Ice

The treatment of leads as cracks or discontinuities (see Coon et al. presentation) requires some shift in the procedure of evaluation and comparison of lead-resolving models and their validation against observations. Common metrics used to evaluate ice model skills are by and large an adaptation of a least square "metric" adopted from operational numerical weather prediction data assimilation systems and are most appropriate for continuous fields and Eilerian systems where the observations and predictions are commensurate. However, this class of metrics suffers from some flaws in areas of sharp gradients and discontinuities (e.g., leads) and when Lagrangian treatments are more natural. After a brief review of these metrics and their performance in areas of sharp gradients, we present two new metrics specifically designed to measure model accuracy in representing linear features (e.g., leads). The indices developed circumvent the requirement that both the observations and model variables be commensurate (i.e., measured with the same units) by considering the frequencies of the features of interest/importance. We illustrate the metrics by scoring several hypothetical "simulated" discontinuity fields against the lead interpreted from RGPS observations.

Levy, G.↗

Sensitive Quantitative Assessment of Balance Disorders

Computerized dynamic posturography (CDP) has become a standard technique for objectively quantifying balance control performance, diagnosing the nature of functional impairments underlying balance disorders, and monitoring clinical treatment outcomes. We have long used CDP protocols to assess recovery of sensory-motor function in astronauts following space flight. The most reliable indicators of post-flight crew performance are the sensory organization tests (SOTs), particularly SOTs 5 and 6, which are sensitive to changes in availability and/or utilization of vestibular cues. We have noted, however, that some astronauts exhibiting obvious signs of balance impairment after flight are able to score within clinical norms on these tests, perhaps as a result of adopting competitive strategies or by their natural skills at substituting alternate sensory information sources. This insensitivity of the CDP protocol could underestimate of the degree of impairment and, perhaps, lead to premature release of those crewmembers to normal duties. To improve the sensitivity of the CDP protocol we have introduced static and dynamic head tilt SOT trials into our protocol. The pattern of postflight recovery quantified by the enhanced CDP protocol appears to more aptly track the re-integration of sensory-motor function, with recovery time increasing as the complexity of sensory-motor/biomechanical task increases. The new CDP protocol therefore seems more suitable for monitoring post-flight sensory-motor recovery and for indicating to crewmembers and flight surgeons fitness for return to duty and/or activities of daily living. There may be classes of patients (e.g., athletes, pilots) having motivation and/or performance characteristics similar to astronauts whose sensory-motor treatment outcomes would also be more accurately monitored using the enhanced CDP protocol. Furthermore, the enhanced protocol may be useful in early detection of age-related balance disorders.

Paloski, Willilam H.↗

Gamma-Ray Pulsar Candidates for GLAST

The Gamma-ray Large Area Space Telescope (GLAST) will be launched less than a year from now, and its Large Area Telescope (LAT) is expected to discover scores to hundreds of gamma-ray pulsars. This poster discusses which of the over 1700 known pulsars, mostly visible only at radio Erequencies, are likely to emit greater than l00 MeV gamma rays with intensities detectable by the LAT. The main figure of merit used to select gamma-ray pulsar candidates is sqrt(E-dot)/d^2, where E-dot is the energy loss due to rotational spindown, and d is the distance to the pulsar. The figure of merit incorporates spin-down flux at earth (proportional to E-dot/d^2) times efficiency, assumed proportional to 1/sqrt(E-dot). A few individual objects are cited to illustrate the issues. Since large E-dot pulsars also tend to have large timing noise and occasional glitches, their ephemerides can become inaccurate in weeks to months. To detect and study the gamma-ray emission the photons must be accurately tagged with the pulse phase. With hours to days between gamma-ray photon arrival times from a pulsar and months to years of LAT exposure needed for good detections, GLAST will need timing measurements throughout the continuous gamma-ray observations. The poster will describe efforts to coordinate pulsar timing of the candidate gamma-ray pulsars.

Thompson, David J.↗

Tracking The Double Eagle

Last summer a trio of aeronauts made aviation history. Ben Abruzzo, Maxie Anderson and Larry Newman, all of Albuquerque, New Mexico, piloted their balloon Double Eagle I1 from Presque Isle, Maine to Miserey, France, some 50 miles from Paris. They were the first to negotiate a successful Atlantic crossing in a freeflying balloon after a score of attempts over a span of more than a century. A year earlier, Abruzzo and Anderson had made an unsuccessful try in their predecessor balloon Double Eagle. On that occasion, a NASA-developed satellite beacon helped save their lives. Carried aboard the balloon, the simple, seven-pound beacon continuously transmitted signals to NASA's Nimbus-6 satellite. Nimbus relayed the signals to monitors at Goddard Space Flight Center, enabling Goddard to compute the balloon's position. Position reports were then telephoned regularly to Double Eagle's control center at Bedford, Massachusetts. This monitoring system proved invaluable when the balloon encountered trouble several days after liftoff.

Source record↗

Bonded Lubricants

Another spinoff to the food processing industry involves a dry lubricant developed by General Magnaplate Corp. of Linden, N.J. Used in such spacecraft as Apollo, Skylab and Viking, the lubricant is a coating bonded to metal surfaces providing permanent lubrication and corrosion resistance. The coating lengthens equipment life and permits machinery to be operated at greater speed, thus increasing productivity and reducing costs. Bonded lubricants are used in scores of commercia1 applications. They have proved particularly valuable to food processing firms because, while increasing production efficiency, they also help meet the stringent USDA sanitation codes for food-handling equipment. For example, a cookie manufacturer plagued production interruptions because sticky batter was clogging the cookie molds had the brass molds coated to solve the problem. Similarly, a pasta producer faced USDA action on a sanitation violation because dough was clinging to an automatic ravioli-forming machine; use of the anti-stick coating on the steel forming plates solved the dual problem of sanitation deficiency and production line downtime.

Source record↗

Multi-channel System for Beat to Beat QT Interval Variability and its Use in Screening for Coronary Artery Disease and Cardiomyopathy

We investigated the ability of beat-to-beat QT interval variability (QTV) and related parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). For this purpose we developed a PC-based ECG software program that in real time, acquires, analyzes and displays QTV in each of the eight independent channels that constitute the 12-lead conventional ECG. The system also analyzes and displays the QTV from QT interval signals that are derived from multiple channels and from singular value decomposition (SVD) to substantially reduce the effect of noise and other artifacts on the QTV results. It also provides other useful SVD-related parameters such as the normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)rho(sub 1^2). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. All QTV parameters that were studied for their accuracy in detecting CM and CAD significantly differentiated both CM and CAD from controls (p less than 0.0001). Retrospective areas under the ROC curve (AUC) of SDNN-QTV, rmsSD-QTV, and QTV Index (QTVI) for CM vs. controls in the lead V5 were 0.85, 0.90, and 0.99, respectively, and those for CAD vs. controls in the lead II were 0.82, 0.82, and 0.89. Other advanced ECG parameters, such as HFQRS RAZ score, LF Lomb of RRV or QRS-T angle, differentiated both CM and CAD from controls less significantly, with the respective AUC values of 0.89, 0.88 and 0.98 for CM vs. controls, and 0.73, 0.71 and 0.80 for CAD vs. controls. QTV parameters (especially QTVI, which is QTV as indexed to RRV) were, diagnostically speaking, amongst the best performing of the advanced ECG techniques studied thus far.

Starc, V.↗

Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead high-fidelity ECG employing and combining the results of several advanced ECG software techniques shows great promise as a rapid and inexpensive tool for screening of heart disease.

Schlegel, T. T.↗

A Portable Universal Hazardous Gas Detector

Experimental work on the Miniature Mass Spectrometer (MMS) at JPL has resulted in a 'table top' configuration with a CCD detector that has demonstrated a detection limit of 50 parts per billion. The CCD detector operates at ambient temperature. Intelligent Ion, Inc., a commercial instrument developer, has taken out a license on the JPL technology and has built a prototype using a Faraday Cup Array detector as a placeholder detector. The prototype instrument was tested at Kennedy Space Center and demonstrated detection limits in the parts per million range. The test results are presented as well as detailed photographs of the prototype instrument. A presentation of the MMS was made to an expert review panel for 'On-Board Environmental Monitoring Systems for the International Space Station (ISS).' The scores obtained by the MMS system are presented. The prototype instrument will be retro fitted with a CCD array detector in August 2004 and will again be tested at KSC. The instrument is expected to show a detection level for hydrazines of 10 ppb and a detection level for solvents below 10 ppb.The expectations are based on raw data from the first batch of CCD's that was tested.

spacecraft fuels↗

Artificial Gravity as a Multi-System Countermeasure: Effects on Cognitive Function

The Space Flight Cognitive Assessment Tool for Windows (WinSCAT) is a medical requirement on the International Space Station, and its purpose is to evaluate cognitive functioning after physical insult (e.g., head trauma, decompression sickness, exposure to toxic gases, medication side effects). The current objective is to assess cognitive functioning in a long duration space mission analog environment where Artificial Gravity is being applied as a countermeasure in a Bed Rest study. Methods: Fifteen male subjects (8 treatment and 7 control) who participated in 21 days of -6 degree head-down bed rest were assessed. Three practice and three baseline WinSCAT test sessions were administered during the pre-bed rest phase of study participation. During the bed rest phase, the WinSCAT test was scheduled every other day, following the centrifuge, for a total of 10 test sessions. (The treatment group received 60 minutes of centrifugation each day during the 21 days of bed rest. The control subjects were strapped to the centrifuge for the same length of time as the treatment group but were not spun.) During the post-bed rest (reconditioning) phase, the test was administered 4 times. Results: Individual differences were found both within and between the treatment and control groups. After controlling for the number of subjects in each group, the treatment group accounted for more off-nominal WinSCAT scores than the control group. Conclusions:There is some preliminary evidence that centrifuge spinning might negatively impact cognitive functioning. However, due to sample size limitations, it cannot be ascertained whether there were significant differences in cognitive performance between the treatment and control groups. If centrifugation had a negative effect on cognitive functioning, consistent decrements would be expected to be found with all treatment subjects across time. Individual differences in underlying cognitive ability and motivation level are other possible explanations for the results found in this study.

Sipes, Walter E.↗

Physiological Self-Regulation and Adaptive Automation

Adaptive automation has been proposed as a solution to current problems of human-automation interaction. Past research has shown the potential of this advanced form of automation to enhance pilot engagement and lower cognitive workload. However, there have been concerns voiced regarding issues, such as automation surprises, associated with the use of adaptive automation. This study examined the use of psychophysiological self-regulation training with adaptive automation that may help pilots deal with these problems through the enhancement of cognitive resource management skills. Eighteen participants were assigned to 3 groups (self-regulation training, false feedback, and control) and performed resource management, monitoring, and tracking tasks from the Multiple Attribute Task Battery. The tracking task was cycled between 3 levels of task difficulty (automatic, adaptive aiding, manual) on the basis of the electroencephalogram-derived engagement index. The other two tasks remained in automatic mode that had a single automation failure. Those participants who had received self-regulation training performed significantly better and reported lower National Aeronautics and Space Administration Task Load Index scores than participants in the false feedback and control groups. The theoretical and practical implications of these results for adaptive automation are discussed.

Prinzell, Lawrence J.↗

Varicella Zoster Virus in Saliva of Patients With Herpes Zoster

Background. VZV DNA is present in saliva of healthy astronauts and patients with Ramsay Hunt syndrome (geniculate zoster). We hypothesized that a prospective analysis of patients with zoster would detect VZV in saliva independent of zoster location. Methods. We treated 54 patients with valacyclovir. On the first treatment day, 7- and 14-days later, pain was scored and saliva examined for VZV DNA. Saliva from six subjects with chronic pain and 14 healthy subjects was similarly studied. Results. Follow-up data was available for 50/54 patients. Pain decreased in 43/50 (86 percent), disappeared in 37 (74 percent), recurred after disappearing in three (6 percent) and increased in four (8 percent). VZV DNA was found in every patient the day treatment was started, decreased in 47/50 (94 percent), transiently increased in three (6 percent) before decreasing, increased in two (4 percent) and disappeared in 41 (82 percent). There was a positive correlation between the presence of VZV DNA and pain, as well as between the VZV DNA copy number and pain (P<0.0005). Saliva of two patients was cultured, and infectious VZV was isolated from one. VZV DNA was present in one patient before rash and in four patients after pain resolved, and not in any control subjects. Conclusion. VZV DNA is present in saliva of zoster patients.

Mehta, Satish K.↗

Middleware Trade Study for NASA Domain

This presentation presents preliminary results of a trade study designed to assess three distributed simulation middleware technologies for support of the NASA Constellation Distributed Space Exploration Simulation (DSES) project and Test and Verification Distributed System Integration Laboratory (DSIL). The technologies are: the High Level Architecture (HLA), the Test and Training Enabling Architecture (TENA), and an XML-based variant of Distributed Interactive Simulation (DIS-XML) coupled with the Extensible Messaging and Presence Protocol (XMPP). According to the criteria and weights determined in this study, HLA scores better than the other two for DSES as well as the DSIL

Bowman, Dan↗

Orbital Debris Quarterly News, Vol. 11, No. 3

Inside - New NASA Procedural Requirement and Technical Standard for Limiting Orbital Debris Generation - Another Collision Avoidance Maneuver Made by NASA Satellite - Two Minor Satellite Fragmentations Identified in the Third Quarter - ISS Zarya Control Module Impact Damage - Three New Satellite Impact Tests - A Preliminary Active Debris Removal Study - Abstracts from the NASA Orbital Debris Program Office - Space Missions and Orbital Box Score

J.-C. liou↗