Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SATELLITE INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A Slow Retrieval Algorithm for Satellite and Surface Based Instruments

We present results of a retrieval algorithm for satellite and ground based instruments using the Arizona radiative transfer code. A state vector describing the atmospheric and surface condition is iteratively modified until the calculated radiances match the observed values. Elements of the state vector include: aerosol concentrations, radius, optical properties, mass-weighted altitudes, chlorophyll concentration and wind speed. While computationally expensive, many assumptions used in other retrieval algorithms are not invoked. We present co-located retrievals for MODIS, SEAWIFS and nearby AERONET sites. MODIS AQUA and SEA WIFS: Ten MODIS (.412 - 2.110 microns) and eight SEA WIFS (.412-.865 microns) radiances (.412-.865 microns) include channels where aerosols absorb and reflect radiation. We focus on retrieving bio-mass burning aerosols that are advected over open ocean. Since chlorophyll absorbs at frequencies where black carbon absorbs, our retrieval algorithm accounts for chlorophyll absorption by simultaneously retrieving both aerosol and chlorophyll amount. Our retrieved chlorophyll concentrations are similar to those from the Ocean Color Group. AERONET: Both Almucantar and Principle plane radiances are used to retrieve the state of the atmosphere and ocean conditions. Our retrieved aerosol size distributions and optical properties are consistent with the aerosol inversions from the AERONET group.

Weaver, C.↗

Space Qualification of Laser Diode Arrays

Laser instruments have great potential in enabling a new generation of remote-sensing scientific instruments. NASA s desire to employ laser instruments aboard satellites, imposes stringent reliability requirements under severe conditions. As a result of these requirements, NASA has a research program to understand, quantify and reduce the risk of failure to these instruments when deployed on satellites. Most of NASA s proposed laser missions have base-lined diode-pumped Nd:YAG lasers that generally use quasi-constant wave (QCW), 808 nm Laser Diode Arrays (LDAs). Our group has an on-going test program to measure the performance of these LDAs when operated in conditions replicating launch and orbit. In this paper, we report on the results of tests designed to measure the effect of vibration loads simulating launch into space and the radiation environment encountered on orbit. Our primary objective is to quantify the performance of the LDAs in conditions replicating those of a satellite instrument, determine their limitations and strengths which will enable better and more robust designs. To this end we have developed a systematic testing strategy to quantify the effect of environmental stresses on the optical and electrical properties of the LDA.

Troupaki, Elisavet↗

Evaluating Multi-Sensor Agreement of Satellite Particulate Backscatter Retrievals by Validatin Against In-Water Measurement

Biogeochemical-Argo profiling floats have increased in situ data density across multiple water types, creating new opportunities to evaluate satellite instrument-to-instrument differences in particulate back scattering coefficient(bbp). Retrievals of bbp from identical GIOP algorithm configurations differ between satellite instruments due to1)algorithm input differences and 2) radiometric differences. 3.Instrument-to-instrument differences must be considered before creating a merged timeseries of satellite ocean color products,in order to distinguish real, environmental contributions from spurious algorithmic or radiometricones

Scott, Joel P.↗

The Vector Electric Field Instrument on the C/NOFS Satellite

We provide an overview of the Vector Electric Field Instrument (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA GSFC instrument designed 1) to investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) to determine the electric fields associated with abrupt, large amplitude, density depletions and 3) to quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions or Equatorial Spread-F. The VEFI instrument includes a vector electric field double probe detector, a Langmuir trigger probe, a flux gate magnetometer, a lightning detector and associated electronics. The heart of the instrument is the set of double probe detectors designed to measure DC and AC electric fields using 6 identical, mutually orthogonal, deployable 9.5 m booms tipped with 10 cm diameter spheres containing embedded preamplifiers. A description of the instrument and its sensors will be presented. If available, representative measurements will be provided.

Pfaff, R.↗

An improved rocket ozonesonde (ROCOZ-A). II - Preparation of stratospheric ozone profiles

The ROCOZ-A radiometer measures ozone by long pathlength photometry in the stratosphere and lower mesosphere. After a rocket launch to an apogee of 70 km, the instrument measures the solar ultraviolet irradiance over its four filter wavelengths as it descends on a parachute. The fundamental values from ROCOZ-A are ozone overburdens versus radar altitude from 53 to 20 km. The slope of these values gives ozone number density. At one standard deviation the repeatability of the ozone overburden measurements averages 2.4 percent. For ozone number density the repeatability averages 3.2 percent with a significant increase at altitudes below the ozone number density maximum. The accuracy limits for overburden and number density are estimated at 5-7 percent. With auxiliary measurements of pressure and temperature, ozone results are also produced in terms of ozone mixing ratio, albeit with a slight broadening of the estimated accuracy limits. The vertical response of ROCOZ-A ozone measurements (full width at half maximum) is 4 km. The assembly of ROCOZ-A profiles can be used to compare with measurements from each of the current NASA and NOAA satellite ozone instruments. In addition, the repeatability of ROCOZ-A allows the use of this instrument as a transfer standard between satellite instruments with different fundamental ozone measurements.

Barnes, Robert A.↗

Numerical Model of the Plasma Sheath Generated by the Plasma Source Instrument Aboard the Polar Satellite

The plasma sheath generated by the operation of the Plasma Source Instrument (PSI) aboard the POLAR satellite is studied by using a 3-dimensional Particle-In-Cell (PIC) code. When the satellite passes through the region of low density plasma, the satellite charges to positive potentials as high as 4050Volts due to the photoelectrons emission. In such a case, ambient core ions cannot accurately be measured or detected. The goal of the onboard PSI is to reduce the floating potential of the satellite to a sufficiently low value so that the ions in the polar wind become detectable. When the PSI is operated, an ion-rich Xenon plasma is ejected from the satellite, such that the floating potential of the satellite is reduced and is maintained at about 2Volts. Accordingly, in our 3-dimensional PIC simulation, we considered that the potential of the satellite is 2Volts as a fixed bias. Considering the relatively high density of the Xenon plasma in the sheath (approx. 10 - 10(exp 3)/cc), the ambient plasma of low density (less than 1/cc) is neglected. In the simulations, the electric fields and plasma dynamics are calculated self-consistently. We found that an "Apple" shape positive potential sheath forms surrounding the satellite. In the region near the PSI emission, a high positive potential hill develops. Near the Thermal Ion Detection Experiment (TIDE) detector away from the PSI, the potentials are sufficiently low for the ambient polar wind ions to reach it. In the simulations, it takes about a hundred electron gyroperiods for the sheath to reach a quasi-steady state. This time is approximately the time taken by the heavy Xe(+) ions to expand up to about one average Larmor radius of electrons from the satellite surface. Using the steady state sheath, we performed trajectory calculations to characterize the detector response to a highly supersonic polar wind flow. The detected ions' velocity distribution shows significant deviations from a shifted Maxwellian in the ambient polar wind population. The deviations are caused by the effects of electric fields on the ions' motion as they traverse the sheath.

Leung, Wing C.↗

Numerical Model of the Plasma Sheath Generated by the Plasma Source Instrument Aboard the Polar Satellite

The plasma sheath generated by the operation of the Plasma Source Instrument (PSI) aboard the Polar satellite is studied by using a three-dimensional particle-in-cell (PIC) code. When the satellite passes through the region of low-density plasma, the satellite charges to positive potentials as high as 40-50 V, owing to the photoelectron emission. In such a case, ambient core ions cannot accurately be measured or detected. The goal of the onboard PSI is to reduce the floating potential of the satellite to a sufficiently low value so that the ions in the polar wind become detectable. When the PSI is operated, ion-rich xenon plasma is ejected from the satellite, such that the floating potential of the satellite is reduced and is maintained at approximately 2 V. Accordingly, in our three-dimensional PIC simulation we considered that the potential of the satellite is 2 V as a fixed bias. Considering the relatively high density of the xenon plasma in the sheath (10-10(exp 3)/cc), the ambient plasma of low density (<1/cc) is neglected. In the simulations the electric fields and plasma dynamics are calculated self-consistently. We found that an 'apple'-shape positive potential sheath forms surrounding the satellite. In the region near the PSI emission a high positive potential hill develops. Near the Thermal Ion Dynamics Experiment detector away from the PSI, the potentials are sufficiently low for the ambient polar wind ions to reach it. In the simulations it takes only about a couple of tens of electron gyroperiods for the sheath to reach a quasi steady state. This time is approximately the time taken by the heavy Xe(+) ions to expand up to about one average Larmor radius of electrons from the satellite surface. After this time the expansion of the sheath in directions transverse to the ambient magnetic field slows down because the electrons are magnetized. Using the quasi steady sheath, we performed trajectory calculations to characterize the detector response to a highly supersonic polar wind flow. The detected ions' velocity distribution shows significant deviations from a shifted Maxwellian in the ambient polar wind population. The deviations are caused by the effects of electric fields on the ions' motion as they traverse the sheath.

Singh, N.↗

Common Calibration Source for Monitoring Long-term Ozone Trends

Accurate long-term satellite measurements are crucial for monitoring the recovery of the ozone layer. The slow pace of the recovery and limited lifetimes of satellite monitoring instruments demands that datasets from multiple observation systems be combined to provide the long-term accuracy needed. A fundamental component of accurately monitoring long-term trends is the calibration of these various instruments. NASA s Radiometric Calibration and Development Facility at the Goddard Space Flight Center has provided resources to minimize calibration biases between multiple instruments through the use of a common calibration source and standardized procedures traceable to national standards. The Facility s 50 cm barium sulfate integrating sphere has been used as a common calibration source for both US and international satellite instruments, including the Total Ozone Mapping Spectrometer (TOMS), Solar Backscatter Ultraviolet 2 (SBUV/2) instruments, Shuttle SBUV (SSBUV), Ozone Mapping Instrument (OMI), Global Ozone Monitoring Experiment (GOME) (ESA), Scanning Imaging SpectroMeter for Atmospheric ChartographY (SCIAMACHY) (ESA), and others. We will discuss the advantages of using a common calibration source and its effects on long-term ozone data sets. In addition, sphere calibration results from various instruments will be presented to demonstrate the accuracy of the long-term characterization of the source itself.

Kowalewski, Matthew↗

Tropical Tropospheric Ozone: A Multi-Satellite View From TOMS and Other Instruments

New tropospheric ozone and aerosol products from the TOMS (Total Ozone Mapping Spectrometer) satellite instrument can resolve episodic pollution events in the tropics and interannual and seasonal variability. Modified-residual (MR) Nimbus 7 tropical tropospheric ozone (TTO), two maps/month (1979-1992, 1-deg latitude by 2-deg longitude) within the region in which total ozone displays a tropical wave-one pattern (maximum 20S to 20N), are available in digital form at http://metosrv2.umd.edu/~tropo. Also available are preliminary 1996-1999 MR-TTO maps based on real-time Earth-Probe (EP)/TOMS observations. Examples of applications are given.

Thompson, Anne M.↗

The Upper Atmosphere Research Satellite microwave limb sounder instrument

The microwave limb sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) is the first satellite experiment using limb sounding techniques at microwave frequencies. Primary measurement objectives are stratospheric ClO, O3, H2O, temperature, and pressure. Measurements are of thermal emission: all are performed simultaneously and continuously and are not degraded by ice clouds or volcanic aerosols. The instrument has a 1.6-m mechanically scanning antenna system and contains heterodyne radiometers in spectral bands centred near 63, 183, and 205 GHz. The radiometers operate at ambient temperature and use Schottky-diode mixers with local oscillators derived from phase-locked Gunn oscillators. Frequency tripling by varactor multipliers generates the 183- and 205-GHz local oscillators, and quasi-optical techniques inject these into the mixers. Six 15-channel filter banks spectrally resolve stratospheric thermal emission lines and produce an output spectrum every 2 s. Thermal stability is sufficient for 'total power' measurements which do not require fast chopping. Radiometric calibration, consisting of measurements of cold space and an internal target, is performed every 65-s limb scan. Instrument in-orbit performance has been excellent, and all objectives are being met.

Barath, F. T.↗

Air Pollution Trends Measured From Terra: CO and AOD Over Industrial, Fire-prone, and Background Regions

Following past studies to quantify decadal trends in global carbon monoxide (CO) using satellite observations, we update estimates and find a CO trend in column amounts of about −0.50 % per year between 2002 to 2018, which is a deceleration compared to analyses performed on shorter records that found −1 % per year. Aerosols are co-emitted with CO from both fires and anthropogenic sources but with a shorter lifetime than CO. A combined trend analysis of CO and aerosol optical depth (AOD) measurements from space helps to diagnose the drivers of regional differences in the CO trend. We use the long-term records of CO from the Measurements of Pollution in the Troposphere (MOPITT) and AOD from the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument. Other satellite instruments measuring CO in the thermal infrared, AIRS, TES, IASI, and CrIS, show consistent hemispheric CO variability and corroborate results from the trend analysis performed with MOPITT CO. Trends are examined by hemisphere and in regions for 2002 to 2018, with uncertainties quantified. The CO and AOD records are split into two sub-periods (2002 to 2010 and 2010 to 2018) in order to assess trend changes over the 16 years. We focus on four major population centers: Northeast China, North India, Europe, and Eastern USA, as well as fire-prone regions in both hemispheres. In general, CO declines faster in the first half of the record compared to the second half, while AOD trends show more variability across regions. We find evidence of the atmospheric impact of air quality management policies. The large decline in CO found over Northeast China is initially associated with an improvement in combustion efficiency, with subsequent additional air quality improvements from 2010 onwards. Industrial regions with minimal emission control measures such as North India become more globally relevant as the global CO trend weakens. We also examine the CO trends in monthly percentile values to understand seasonal implications and find that local changes in biomass burning are sufficiently strong to counteract the global downward trend in atmospheric CO, particularly in late summer.

carbon monoxide↗