Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Retrofit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions on future and extreme weather data for building simulation and analysis in a changing climate

Weather plays a significant role in building operations as it directly influences HVAC loads and in turn the building energy and thermal performance. In a changing climate, future trends and extreme weather events become critical concerns in the global building decarbonization and clean energy transition. This paper aims to address ten key questions concerning extreme and future weather data for building applications, and more importantly to identify research gaps and guide the curation and selection of future and extreme weather data for use in building performance simulation and assessment. The paper intends to inform architects and engineers, operators, owners, policy makers, and other stakeholders on considering the impacts of future and extreme weather data and adopting strategies for selecting and applying this data in various use cases related to building design, operation, and retrofit for energy efficiency, electrification, and climate resilience.

Yan, Da↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Nondestructive neutron imaging diagnosis of acidic gas reduction catalyst after 400-Hour operation in natural gas furnace

Residential natural gas furnaces are the primary space-heating devices in US homes, leading to substantial environmental impact caused by the acidic components in the furnace combustion gases. Here, to experimentally demonstrate acidic gas reduction in a furnace, a monolithic catalyst was fabricated and was called the AGR. A commercially-available condensing furnace was retrofitted with the AGR, and a 400-hour reliability and durability test was conducted. The results showed that the AGR significantly reduced acidic gases in the flue gas and produced condensate with neutral pH. Challenges were also revealed: inappropriate condensate drainage caused incomplete combustion and amorphous carbon deposits. To nondestructively survey the internal state of the AGR, neutron computed tomography (NCT) was employed to produce spatially resolved 2D and 3D representations of the 2-L, aged AGR component. The NCT results confirm the integrity of the AGR component, which consists of two blocks, without deformation or damage to AGR channels. The distribution of the particle accumulation in the middle of the top block was visibly heavier than the entrance and exit of the top block. The representative cross-section views revealed significant aggregation in the central region but not at the rim. The spatially resolved details provide in-depth diagnosis, evaluation, and understanding of the AGR. The insights can enable new AGR designs that realize a uniform and self-cleaning flow pattern, alleviate significant particle aggregation, and thus enhance AGR-enabled furnace performance. The neutron imaging method demonstrates the good potential that can diagnose faults and improve the design, optimization, and production processes of novel catalysts and other components or systems with heavy metal shell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unlocking naphtha from polyolefins using Ni-based hydrocracking catalysts

Naphtha (C 5 -C 12 alkanes) is a platform feedstock in the petroleum industry and an ideal target for reutilizing plastic waste at scale. Hydrocracking has emerged as a promising technology for deconstructing polyolefins to naphtha. However, contemporary catalysts rely on Pt to achieve high rates, while earth-abundant metals (EAM) perform poorly. Herein, we develop high-performance Ni/BEA catalysts for polyolefin hydrocracking, achieving complete low-density polyethylene (LDPE) deconstruction with 80 % maximum naphtha yield within 12 h at 250 °C, 60 bar H 2 , and a catalyst-to-polymer ratio of 1:100. These catalysts are versatile, accommodating virgin resins and commercial polymer products, and are directly reusable and regenerable. Comparative analysis highlights that 5Ni/BEA(25) exhibits the highest naphtha productivity of 11.4 $\huge{(}$$\frac{g_{Naphtha}}{g_{cat}{•h}}$$\huge{)}$, surpassing previously reported Pt- and EAM-based catalysts by 2.5–6.2x. Technoeconomic and life-cycle analyses reveal naphtha from LDPE hydrocracking is economically and environmentally competitive to fossil-fuel-derived naphtha. In conclusion, these advancements pave the way for the industrial implementation of earth-abundant Ni-based catalysts in polyolefin hydrocracking, followed by retrofitting steam crackers to address plastics waste at scale.

Circular Economy↗

A scoping review of non-destructive testing (NDT) techniques in building performance diagnostic inspections

Understanding building envelope thermodynamics is an essential foundation of building sciences, mainly due to the envelope’s role as a boundary layer for exterior environments, as well as a container and regulator of internal microclimates. This paper presents a scoping literature review of select Non-destructive Testing (NDT) techniques for building envelope scanning and surveying for thermodynamic diagnostics. The investigation focuses specifically on reviewing six NDT techniques: Ground Penetrating Radar (GPR), Light Detection and Ranging (LiDAR)/Laser Scanning, Thermography, Ultrasound, Close-Range Photogrammetry and Through Wall Imaging Radar (TWIR). The aim is to identify knowledge gaps in terms of their use in accurately characterizing envelope compositions for further integration in Building Energy Modeling (BEM). Each technique was evaluated according to set categories imbibed from the American Society of Heating, Refrigerating, and Air Conditioning Engineering (ASHRAE) Standard 211P that showcase the technique’s ability to extract various relevant information. A framework is then developed to inform users on how to use hybrid NDT-based workflows applied in building envelope energy audits. The study concludes by discussing possibilities of utilizing NDT in large-scale audit automation, BEM integration, and developing built environment policies focusing on increasing existing building performance through retrofitting design.

36 MATERIALS SCIENCE↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

Resilient cooling strategies – A critical review and qualitative assessment

The global effects of climate change will increase the frequency and intensity of extreme events such as heatwaves and power outages, which have consequences for buildings and their cooling systems. Buildings and their cooling systems should be designed and operated to be resilient under such events to protect occupants from potentially dangerous indoor thermal conditions. This study performed a critical review on the state-of-the-art of cooling strategies, with special attention to their performance under heatwaves and power outages. We proposed a definition of resilient cooling and described four criteria for resilience—absorptive capacity, adaptive capacity, restorative capacity, and recovery speed —and used them to qualitatively evaluate the resilience of each strategy. The literature review and qualitative analyses show that to attain resilient cooling, the four resilience criteria should be considered in the design phase of a building or during the planning of retrofits. The building and relevant cooling system characteristics should be considered simultaneously to withstand extreme events. A combination of strategies with different resilience capacities, such as a passive envelope strategy coupled with a low-energy space-cooling solution, may be needed to obtain resilient cooling. Finally, a further direction for a quantitative assessment approach has been pointed out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correlating and Simulating Socio-Demographically Driven Residential End-Use Activity Schedules

Incorporating socio-demographic and behavioral considerations into decision-support tools is crucial for identifying gaps and addressing consumer needs to ensure reliable and affordable energy solutions. In energy simulation models, the correlation between socio-demographics and time-use behavior is not well-captured. Thus, we developed a large-scale simulation workflow to generate schedules for 10 residential activities across 24 population segments defined by age, income, and employment status. Using pre-pandemic 2015-2019 American Time Use Survey (ATUS) data, we used ANOVA to confirm the correlation between demographic factors and time use. We explored three k-modes clustering methods-backward, forward, and a new hybrid approach-to delineate the occupancy patterns based on demographics. Using the probability of cluster membership for each population segment and a time inhomogeneous Markov chain to generate activity transition probabilities for each cluster, we simulated 50,000 schedules per segment and validated them against the ATUS data. The hybrid method produced the most socio-demographically differentiated clusters while demonstrating comparable performance to other approaches, with an overall root mean square error of 0.12 for both weekday and weekend schedules. Thus, the hybrid method, where each cluster is dominated by certain demographic segments and occupancy patterns, offers more modeling versatility in terms of scenario analysis. The new workflow improves the socio demographic differentiation of energy consumption by considering differences in time use. This approach enables future research on demographically segmented time of use (TOU) energy consumption, including impacts of TOU utility bills and rate analysis, long-run marginal emissions, and energy retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AI-Based Analytics and Energy Modeling Framework for Characterizing Urban Energy Systems

Developing location-specific district energy models is essential for understanding energy patterns and supporting efficient management and planning decisions. However, accurately characterizing these models remains challenging due to gaps in building characteristics and labor-intensive traditional modeling workflows. To address these challenges, we develop an AI-based framework that integrates top-down and bottom-up building energy data to automate urban energy model characterization. The framework trains multimodal deep learning models using heterogeneous ResStockTM datasets to infer missing building characteristics from varying levels of known information and generate simulation-ready inputs for district-scale energy modeling. It also employs a conditioning-based injection approach to generate ”what-if” scenarios, enabling users to explore retrofit, efficiency, and technology-upgrade pathways. Integrated within URBANoptTM, a bottom-up district energy modeling platform for simulating co-located buildings, the framework infers detailed building-level inputs required for bottom-up simulations. Both localized and generalized AI models are developed to learn relationships across categorical, numerical, and time-series data, enabling reconstruction of missing attributes and generation of targeted upgrade scenarios. We demonstrate this methodology on a residential neighborhood in Baltimore, MD, assessing internal consistency against ResStock reference data and URBANopt simulation, and comparing selected attributes against real-world building characteristics. Results show strong overall predictive accuracy in data completion and scenario generation, with localized and generalized models offering complementary trade-offs between precision and scalability. Overall, our automated framework streamlines energy modeling and provides a reliable framework for urban building energy characterization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Building thermal dynamics modeling with deep transfer learning using a large residential smart thermostat dataset

Understanding thermal dynamics and obtaining the computational model of residential buildings enable its scaled application in energy retrofits, control optimization and decarbonization. In this paper, we present a deep learning approach to model building thermal dynamics with smart thermostat data collected from residential buildings, with the goal to investigate model generalizability. In the first stage, we developed and compared different Deep Learning architectures including Convolutional Neural Networks (CNN), Long Short-Term Memory (LSTM) models and CNN-LSTM to predict indoor air temperature in a multi-step time horizon. In the second stage, we implemented a Transfer Learning (TL) process, which aims to improve the prediction performance on a new set of buildings (targets), exploiting the knowledge of related or similar buildings (sources). Different TL strategies and source model identification methods were investigated. The study showed that the CNN-LSTM performed the best among the architectures compared, with an average Mean Absolute Error (MAE) of 0.26 °C for one-hour-ahead (twelve 5-min future steps) predictions. Furthermore, the results showed that freezing the LSTM layer and fine-tuning the other layers of the CNN-LSTM achieved the best performance among four TL strategies, which further improved the performance with respect to a machine learning approach by 10%, and proving the effectiveness and generalizability of the proposed approach. A comparison of three different source model identification methods showed that randomly selecting source models constrained by similar building characteristics can provide good TL performance while retaining simplicity comparing with other quantitative source identification methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational analysis of flame initiation, quenching, and re-ignition in a prechamber natural gas engine under varying EGR-dilution levels

The on-road natural-gas (NG) fueled transportation relies on stoichiometric spark-ignition engines for the advantages of simple after-treatment system despite the efficiency penalty relative to lean-burn combustion strategies. Exhaust gas recirculation (EGR) has the potential to reduce this efficiency gap at low to moderate loads without the need for complex lean-exhaust aftertreatment systems. However, EGR dilution leads to reduced combustion stability and increased cycle-to-cycle variability. A promising technology that has the potential to achieve reliable operation under diluted conditions is the prechamber ignition (or turbulent jet ignition) which uses chemically active turbulent jets generated from combustion inside a prechamber to initiate, stabilize and accelerate combustion of the mixture inside the main chamber. The present work focusses on developing a RANS-based CFD approach to accurately reproduce in-cylinder phenomena in a stoichiometric NG prechamber-assisted heavy-duty engine without relying on complex combustion models that account for turbulence-chemistry interactions. This is necessary because reactive prechamber jets at high EGR dilution tend to extinguish while emerging into the main chamber, which is followed by a phase of re-ignition — a phenomenon that conventional G-equation or well-stirred reactor combustion models cannot reproduce. With addition of a damping multiplier to the well-stirred reactor model, the predictions are seen to show good agreement with experimental pressure evolution and combustion images acquired from a single cylinder Cummins N-14 optical diesel engine retrofitted with a prechamber ignition system. Model predictions of local heat release in the flame and temperature evolution inside the flame are used to investigate combustion dynamics in the prechamber and the main chamber. It is seen that the well-stirred reactor model with the inclusion of damping is able to reproduce the temporary reduction in heat release within the flame, which can be considered equivalent to quenching of jets, and the subsequent re-ignition of the flame inside the main chamber. The delay between quenching and re-ignition depends on the amount of dilution, as explained by an illustration of flame evolution in a Borghi diagram.

Prechamber ignition↗