Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resource Size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Geostationary platform study: Advanced ESGP/evolutionary SSF accommodation study

The implications on the evolutionary space station of accommodating geosynchronous Earth Orbit (GEO) facilities are assessed. These facilities include unmanned satellites and platforms, manned elements, and transportation and servicing vehicles/elements. The latest existing definitions of typical unmanned GEO facilities and transportation and servicing vehicles/elements are utilized. The physical design, functional design, and operations implications at the space station are determined. Various concepts of the space station from past studies are utilized ranging from the IOC Multifunction Space Station to a branched transportation node space station and the implications of accommodating the GEO infrastructure at each type are assessed. Where possible, parametric data is provided to show the implications of variations in sizes and quantities of elements, launch rates, crew sizes, etc. The use of advanced automation, robotics equipment, and an efficient mix of manned/automated support for accomplishing necessary activities at the space station are identified and assessed. The products of this study are configuration sketches, resource requirements, trade studies, and parametric data.

Source record↗

Geostationary platform study: Advanced ESGP/evolutionary SSF accommodation study

The implications on the evolutionary space station of accommodating geosynchronous Earth Orbit (GEO) facilities including unmanned satellites and platforms, manned elements, and transportation and servicing vehicles/elements. The latest existing definitions of typical unmanned GEO facilities and transportation and servicing vehicles/elements are utilized. The physical design, functional design, and operations implications at the space station are determined. Various concepts of the space station from past studies are utilized ranging from the IOC Multifunction Space Station to a branched transportation node space station, and the implications of the accommodation the GEO infrastructure of each type are assessed. Where possible, parametric data are provided to show the implications of variations in sizes and quantities of elements, launch rates, crew sizes, etc. The use of advanced automation, robotics equipment, and an efficient mix of manned/automated support for accomplishing necessary activities at the space station are identified and assessed. The products of this study are configuration sketches, resource requirements, trade studies, and parametric data.

Source record↗

MiGRIDS

MiGRIDS is a software that models islanded microgrid power systems with different controls and components. For example, using load and resource data from a microgrid, you could model it with additional wind turbines, battery etc. You could also try out different dispatch schemes to see which one worked best. MiGRIDS is designed to help optimize the size and dispatch of grid components in a microgrid. While a grid connect feature is expected to be added in the future, islanded operation is the focus. Note that this is a basic implementation and more features and functionality (such as a GUI) are coming! MiGRIDS runs time-step energy balance simulations for different grid components and controls. In smaller microgrid environments, dispatch decisions are being made on the order of seconds. In order to fully capture their effect, this tool lets you run simulations on the order of seconds. The end result is a more realistic representation of what can be achieved by integrating different components and control strategies in a grid.

Morgan, Tawna↗

Evaluating the Curtailment Risk of Non-Firm Utility-Scale Solar Photovoltaic Plants under a Novel Last-In First-Out Principle of Access Interconnection Agreement

With the increasing share of distributed energy resources on the electric grid, utility companies are facing significant decisions about infrastructure upgrades. An alternative to extensive and capital-intensive upgrades is to offer non-firm interconnection opportunities to distributed generators, via a coordinated operation of utility scale resources. This paper introduces a novel flexible interconnection option based on the last-in, first-out principles of access aimed at minimizing the unnecessary non-firm generation energy curtailment by balancing access rights and contribution to thermal overloads. Although we focus on solar photovoltaic (PV) plants in this work, the introduced flexible interconnection option applies to any distributed generation technology. The curtailment risk of individual non-firm PV units is evaluated across a range of PV penetration levels in a yearlong quasi-static time-series simulation on a real-world feeder. The results show the importance of the size of the curtailment zone in the curtailment risk distribution among flexible generation units as well as that of the “access right” defined by the order in which PV units connect to the grid. Case study results reveal that, with a proper selection of curtailment radius, utilities can reduce the total curtailment of flexible PV resources by up to more than 45%. Findings show that non-firm PV generators can effectively avoid all thermal limit-related upgrade costs.

14 SOLAR ENERGY↗

Forecasting distributed energy resources adoption for power systems

Failing to incorporate accurate distributed energy resource penetration forecasts into long-term resource and transmission planning can lead to cost inefficiencies at best and system failures at worst. We have developed an open-source tool that employs an advanced Bass specification to calibrate and forecast technology adoption. The advanced specification includes geographic clustering, exogenously estimated market size, and dynamic time steps. Training on historical adoption of rooftop photovoltaics at the U.S. county-level and using detailed techno-economic estimates, our model achieves a two-year average mean-absolute-percentage-error of 19% in predicting system counts at the county-level, weighted by population. Model error was negatively correlated with market maturity - the error was 12% for counties in states with at least 28 W-per-capita of installed capacity. The advanced specification significantly reduces unweighted forecasting percent error compared to a conventional Bass specification: from 196% to 25% for capacity and from 226% to 22% for system count.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Challenges and Technology-Driven Opportunities for Safeguarding Microreactors

Nuclear microreactors (MRs) represent a new class of reactors characterized by their compactness, portability, and low power output. These features enable MRs to supply electricity and process heat to remote areas like military bases; inaccessible locations; small grids, such as on islands; or disaster impacted areas. Compared to traditional light water reactors, MRs have a unique set of attributes that need to be considered for the implementation of safeguard strategies. Current safeguard methodologies are reactor technology specific and are employed on large, stationary reactors where there is easy access by safeguards inspectors and where safeguard equipment can be easily installed and retrofitted. While there are numerous benefits to MRs, their compact size, portability, scalability, and operational lifetime create challenges to the traditional safeguard approaches, thus needing novel safeguard strategies. Here, this paper addresses the unique challenges posed by MRs to the international nuclear safeguards regime, including limited human resources, and explores how technology advancements can help mitigate these challenges. Specifically, it examines novel technologies that could contribute to establishing a comprehensive safeguards framework for MRs. These safeguards-enabling technologies encompass safeguards by design, remote sensing and monitoring technologies, applications of artificial intelligence and machine learning algorithms, utilization of digital twins, and system of systems assessments. While each of these safeguards-enabling technologies offers partial solutions to the challenges posed by MRs for the international safeguards regime, none of them alone can entirely address these challenges. Consequently, a combination of the safeguards-enabling technologies outlined in this paper is recommended to establish a robust safeguards regime for MRs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cognitive IoT and Edge Computing for Intrusion Detection with Federated TinyML

Internet of Things (IoT) and Edge Computing (EC) are rapidly becoming an integral part of the modern society. By 2030, there is estimated to be over 40 billion active and connected IoT devices [1]. This rapid progress also comes with a significant implication on cybersecurity. Back-end infrastructure and systems have a much broader attack than they did previously due to vulnerable IoT/EC devices being connected to wireless networks. This expanding attack surface is a growing concern because IoT/EC are increasingly being used in critical systems such as power grids, health care, and smart homes. To effectively address a problem of this scale, cognitive cyber methods—which can autonomously detect and react to cyber attacks as they develop—are needed. To address this, we bring Artificial Intelligence (AI) and Machine Learning (ML) to IoT/EC devices, using tinyML to monitor voluminous IoT data against cyber threats, and using Federated Learning (FL) to share local detection knowledge across the system while preserving privacy. We propose a novel three-layer architecture: (1) an IoT layer for tinyML-based inference, (2) an edge layer for ML model training, and (3) a cloud layer for FL operations. Using the publicly available 11-class N-BaIoT dataset [2], we demonstrate that this architecture mitigates resource constraints at the IoT layer while improving detection accuracy over standard two-layer designs. An outlier-resistant scaler, feature reduction, and quantization enable the tinyML model to maintain detection accuracy with a reduced model size. Additionally, federated learning that only utilizes the intersection (across heterogenous devices) of the reduced feature set achieves superior detection accuracy compared to locally trained models.

Li, Mingyan [ORNL] (ORCID:0009000569532640)↗

Evaluation of residue management practices on barley residue decomposition

Optimizing barley (hordeum vulgare L.) production in Idaho and other parts of the Pacific Northwest (PNW) should focus on farm resource management. The effect of post-harvest residue management on barley residue decomposition has not been adequately studied. Thus, the objective of this study was to determine the effect of residue placement (surface vs. incorporated), residue size (chopped vs. ground-sieved) and soil type (sand and sandy loam) on barley residue decomposition. A 50-day(d) laboratory incubation experiment was conducted at a temperature of 25°C at the Aberdeen Research and Extension Center, Aberdeen, Idaho, USA. Following the study, a Markov-Chain Monte Carlo (MCMC) modeling approach was applied to investigate the first-order decay kinetics of barley residue. An accelerated initial flush of residue carbon(C)-mineralization was measured for the sieved (Day 1) compared to chopped (Day 3 to 5) residues for both surface incorporated applications. The highest evolution of carbon dioxide (CO 2 )-C of 8.3 g kg -1 dry residue was observed on Day 1 from the incorporated-sieved application for both soils. The highest and lowest amount of cumulative CO 2 -C released and percentage residue decomposed over 50-d was observed for surface-chopped (107 g kg -1 dry residue and 27%, respectively) and incorporated-sieved (69 g kg -1 dry residue and 18%, respectively) residues, respectively. There were no significant differences in C-mineralization from barley residue based on soil type or its interactions with residue placement and size (p >0.05). The largest decay constant k of 0.0083 d -1 was calculated for surface-chopped residue where the predicted half-life was 80 d, which did not differ from surface sieved or incorporated chopped. In contrast, incorporated-sieved treatments only resulted in a k of 0.0054 d -1 and would need an additional 48 d to decompose 50% of the residue. Future residue decomposition studies under field conditions are warranted to verify the residue C-mineralization and its impact on residue management.

59 BASIC BIOLOGICAL SCIENCES↗

Surface Atmosphere Integrated Field Laboratory (SAIL) Science Plan

Mountains are the natural water towers of the world, effectively turning water vapor into readily available fresh water through precipitation, snowpack, and runoff. Unfortunately, Earth system models (ESMs) have persistently been unable to predict the timing and availability of water resources from mountains because the source(s) of model error are difficult to isolate in complex terrain with limited atmospheric or land-surface observations. Further complications arise from the gross scale mismatch between ESM grid box sizes and the relevant scales of mountainous hydrological processes. The mountain hydrometeorology community has repeatedly called for integrated atmospheric and land observations of water and energy budgets in complex terrain that span these scales to establish benchmarks against which scale-dependent models can be further developed.

54 ENVIRONMENTAL SCIENCES↗

Abstract for CRADA between NETL and H2 Resources Pty Ltd.

NETL and H2 Resources Pty Ltd. will collaborate under this CRADA project to evaluate and design a scaled-up microwave assisted coal gasification process on Australian low-rank coal. This project will include parametric studies on the top size of feed coal using continuous feed microwave capabilities at NETL.

01 COAL, LIGNITE, AND PEAT↗

Reticular Materials and AI-Driven Computer Simulations for Seawater Mining of Valuable Metals (Final Technical Report)

This Final Technical Report describes our exploratory efforts that combine reticular materials synthesis (hydrolytically robust metal–organic frameworks, MOFs) with AI‑enabled molecular simulations to develop mechanistic, quantitative design rules for recovering lithium and other alkali-metal ions from highly dilute, competitive aqueous resources (e.g., seawater). The central outcome is a joint experimental–computational study of ion uptake in MOF‑808 (Chemical Science, 2025) that quantifies both thermodynamics and kinetics of Li + , Na + , and K + uptake and identifies how pore size, pore hydration state, dehydration penalties, and pore-window transport barriers govern selectivity. Guided by these insights, we synthesized and tested functionalized MOF‑808 and multivariate MOFs incorporating ion-recognition motifs (including carboxylates and crown-ether linkers) and evaluated uptake in synthetic seawater, highlighting framework topology and pore chemistry as levers for improved Li + /Na + discrimination. We also developed transferable simulation models, enhanced-sampling protocols, and automated workflows that enable systematic screening of porous sorbents.

42 ENGINEERING↗

Performance Characterization of InCharge™ ICE-66 V2X Bidirectional DC Fast Charger

Vehicle-to-grid (V2G) technology extends the role of Plug-in Hybrid Vehicle’s (PHEV) and Battery Electric Vehicle’s (BEV) batteries beyond transportation by enabling bidirectional power transfer between the vehicle's onboard energy storage and the utility grid. Modern battery-powered vehicles are equipped with high-capacity battery packs that remain stationary and underutilized for the majority of their operational life. A vehicle used for daily commuting may be parked and connected to charging infrastructure for 18–20 hours per day, representing a significant untapped energy resource. When considered at scale, the aggregated storage capacity of a modest fleet of 10–15 vehicles within a single parking facility can reach the MWh range, sufficient to partially offset peak demand for a mid-size commercial building or contribute meaningful ancillary services to the local grid. The ability to charge during off-peak periods when electricity prices are low and discharge during peak demand when prices are high positions EV batteries as distributed energy arbitrage assets, with the potential to offset vehicle ownership and charging costs. Beyond energy arbitrage, V2G-capable assets can provide ancillary grid services through active and reactive power injections. Active power supports grid frequency regulation, while reactive power supports local voltage regulation. Together, these capabilities establish V2G as a technically promising and economically relevant pathway toward greater integration of battery-powered vehicles into the broader energy system.

33 ADVANCED PROPULSION SYSTEMS↗

Analysis of the quality of image data acquired by the LANDSAT-4 thematic mapper and multispectral scanners

Image products and numeric data were extracted from both TM and MSS data in an effort to evaluate the quality of these data for interpreting major agricultural resources and conditions in California's Central Valley. The utility of TM data appears excellent for meeting most of the inventory objectives of the agricultural resource specialist. These data should be extremely valuable for crop type and area proportion estimation, for updating agricultural land use survey maps at 1:24,000-scale and smaller, for field boundary definition, and for determining the size and location of individual farmsteads.

Colwell, R. N.↗

Common Habitat Base Camp for Moon and Mars Surface Operations

The Common Habitat uses the SLS Core Stage Liquid Oxygen tank as the primary structure (similar to Skylab) and has an internal architecture compatible with microgravity, lunar gravity, and Mars gravity, such that identical versions of the same design can be used in all three environments. Applying the large dimensions and eight-person crew size of the Common Habitat to a surface architecture leads to a unique base camp configuration. A notional such base camp is described in this analysis. The base camp includes four distributed zones – habitation, landing, power, and resource production. The base camp is deployed and assembled in three phases: site preparation, element staging, and habitat delivery, each of which are briefly discussed. Crew arrival and departure is discussed, including variations caused by orbital mechanics-induced differences between the Moon and Mars base camps. Trash and logistics operations are described. Finally, crew operations within the base camp are described.

Lunar Outpost↗

Maximizing the Benefits of On-Site Renewable Energy Generation Using On-Site Energy Storage

The commercial and industrial building sectors have a major role to play in a U.S. low-carbon future. Building owners can make a difference by deploying on-site renewable generation and storage technologies, which facilitates future-proofing their buildings as well as more effectively meeting the service requirements of the building. This resource provides an overview of common generation, storage, and load management technologies in behind-the-meter systems, and serves as a primer to demonstrate the impact on net building loads required from the grid for different sizes of renewable generation along with on-site electrical and thermal storage. These discussions can help commercial building owners communicate the value of these systems to project teams and develop innovative behind-the-meter solutions to achieve their energy goals.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Impact of system parameters and geospatial variables on the reliability of residential systems with PV and energy storage

A reliable power supply is the foundation of modern society, enabling technologies used to function within a society. Residential systems are places where the end users directly consume power, enabling technologies to sustain life. With the emergence of behind-the-meter resources, the end-users have some control over power supply reliability. The intermittency and variability of these resources impact residential system reliability. In this work, we study the reliability performance of a grid-supplemented residential system with behind-the-meter Distributed Energy Resources(DER) subject to various system parameters and geospatial variables. We propose a multistate reliability model for the behind-the-meter microinverter-based Photo Voltaic (PV) system and integrated inverter-based energy storage (ES) system. A sequential Monte Carlo method is then presented to evaluate the reliability indices for the residential system with behind-the-meter DERs as the main supply and the grid as the backup. The sequential Monte Carlo method is used to analyze the reliability performance of the residential model at the top 100 populous counties of the United States, where actual load and solar irradiance data at the counties is used. In the analysis, the sensitivity of indices to system parameters such as DER size and the sensitivity of the indices to climate zone and gross horizontal irradiation (GHI), which affects the load conditions and the PV output of the residential system, is performed. The analysis results show that the system parameters and the geospatial variables significantly impact the residential system’s reliability. The insights from this analysis will be of immense value to the distribution system planners to provide zone-specific guidelines for DER system sizing and toward the evolution of utility business models. Finally, the methodology developed can be used to extend the analysis to other locations.

14 SOLAR ENERGY↗

Wind and Solar Hybrid Power Plants for Energy Resilience

Wind-solar-storage hybrid power plants represent a significant and growing share of new proposed projects in the United States (U.S.). Their uptake is supported by increasing renewable energy market share, technical abilities for dispatch and control, and decreasing wind, solar, and battery storage costs. Simultaneously, generation and storage resources are increasingly used in distributed power systems. While concerns around the reliability of the aging, transforming U.S. electric grid are growing, diversifying energy resources through hybridization or spatial distribution provides an opportunity to enhance power system resilience compared to single-source generation. Understanding where to build hybrids for resilience value, rather than bulk power supply, has not been fully explored in previous studies. Therefore, in this study, we complete a national complementarity analysis to identify areas in the U.S. that are particularly suited for wind-solar hybrid power plant development. We show the importance of seasonal and diurnal patterns in assessing complementarity, and identify that regions in the Great Plains, Midwest, and Southeast are particularly suited for hybrid power plants. We demonstrate the resilience value of hybridization for a reference system based near Memphis, Tennessee, and show optimal sizing of wind, solar, and storage assets given 1.0 and 0.9 critical load factors. Results indicate that pairing wind and solar assets better meet constant load demand and reduce storage requirements compared to solar alone. These results enable future work integrating complementarity metrics in resilience frameworks and indicate a need for more finer resolution of local resource, demand, and hazard data.

14 SOLAR ENERGY↗

Optimizing and Exploring Untapped Micro-Hydro Hybrid Systems: a Multi-Objective Approach for Crystal Lake as a Large-Scale Energy Storage Solution

Increasing electricity demand and concerns about climate change and fossil fuel consumption have highlighted the importance of renewable energy resources and storage systems. This paper proposes a method for exploring untapped pumped hydro storage potentials to accommodate intermittent renewable energy generation profiles. Hourly measured data from 2022 in Benzie County, Michigan, United States, were gathered for system sizing and a thorough, realistic analysis. By employing the multi-objective grey wolf optimization algorithm, we formulated optimal sizing and energy-management strategies for three different scenarios. Unlike similar studies, the 3rd with triple objective functions (OFs) scenario aims to maximize both reliability and ecological OFs while minimizing the cost OF. It has shown promising results with multiple solutions, considering economic, environmental, and reliability factors. A case study conducted in Crystal Lake, Michigan, revealed that although Crystal Lake would function only as a micro-hydro power facility, it is a promising and huge storage unit with a substantial storage capacity of around 14.9734GWh. The system investigated is significant in the USA due to its rapid deployment capabilities, minimal construction requirements, and ease of integration with the distribution grid. The fuzzy logic method was employed to identify the best non-dominant solution among the other solutions. Furthermore, these outcomes include a notably low levelized cost of energy at 0.046147$/kWh, a robust index of reliability of 99.705%, and a significant reduction in CO₂ emissions amounting to 7.9142×10 3 tons/year, when considering the triple OFs. The paper’s methodology provides valuable insights for regions aiming to utilize renewable energy from untapped storage sources.

13 HYDRO ENERGY↗