Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A measurement concept for hot-spot BRDFs from space

Several concepts for canopy hot-spot measurements from space have been investigated. The most promising involves active illumination and bistatic detection that would allow hot-spot angular distribution (BRDF) measurements from space in a search-light mode. The concept includes a pointable illumination source, such as a laser operating at an atmospheric window wavelength, coupled with a number of high spatial-resolution detectors that are clustered around the illumination source in space, receiving photons nearly coaxial with the reto-reflection direction. Microwave control and command among the satellite cluster would allow orienting the direction of the laser beam as well as the focusing detectors simultaneously so that the coupled system can function like a search light with almost unlimited pointing capabilities. The concept is called the Hot-Spot Search-Light (HSSL) satellite. A nominal satellite altitude of 600 km will allow hot-spot BRDF measurements out to about 18 degrees phase angle. The distributed are taking radiometric measurements of the intensity wings of the hot-spot angular distribution without the need for complex imaging detectors. The system can be operated at night for increased signal-to-noise ratio. This way the hot-spot angular signatures can be quantified and parameterized in sufficient detail to extract the biophysical information content of plant architectures.

Reflectivity↗

Identification of background limitations to ultra-sensitive $\mathrm{LSC}$ counting through $\mathrm{ICP}$-$\mathrm{MS}$ assay of $\mathrm{LSC}$ cocktails

We report the performance of LSC cocktails in ultra-sensitive applications was evaluated. Backgrounds from radioactive contaminations in commercially available and in-house developed liquid scintillation cocktails were measured and compared to the predicted background levels of the ultra-low background liquid scintillation counter. Through the ICP-MS assay of the cocktails and their constituents, potassium impurities in the surfactant component were identified as a significant source of background, potentially limiting the use of LSC counting in ultra-sensitive applications. This work lays the groundwork for future research towards ultrapure LSC cocktails for ultrasensitive LSC counting

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observations regarding inclusions in the growth of $\mathrm{Cs}$ 2 $\mathrm{HfCl}$ 6 single crystal scintillators

Cs 2 HfCl 6 (CHC) is a promising high density, high-Z, non-hygroscopic, and high energy resolution scintillator. In CHC, many crystals have CsCl inclusions that form during growth. In this paper, we investigate how material synthesis, growth rate, and thermal gradient affect the formation of CsCl inclusions and their effect on scintillation performance. First, precursor material was made through a methanol synthesis process both with and without hydrochlorination. Next, five crystals were grown using Bridgman method, at growth rates of 1 or 0.5 mm/h, and thermal gradients of 21 °C or 34 °C per millimeter. The best overall performance was observed in a 22 mm diameter crystal produced using hydrochlorination which was grown at 1 mm/h in a thermal gradient of 34 °C per millimeter. It had a light yield of 36,000 photons/MeV and an energy resolution of 4.0% at 662 keV. Finally, we have also shown that poorer scintillation performance in the lower quality crystals is most likely due to reduced light collection caused by a higher concentration of inclusions.

36 MATERIALS SCIENCE↗

Effects of magnetic fields on HPGe tracking detectors

Here, we present a study of magnetic fields effects on the position resolution and energy response of hyper-pure germanium detectors. Our results provide realistic estimates of the potential impact on the resolving power of tracking-arrays from (fringe) magnetic fields present when operating together with large spectrometers. By solving the equations of motion for the electron and holes in the presence of both electric and magnetic fields, we analyzed the drift trajectories of the charge carriers to determine the deviations in the positions at the end point of the trajectories, as well as changes in drift lengths affecting the energy resolution and peak shift due to trapping. Our results show that the major effect is in the deviation of the transverse (to the electric field direction) position and suggest that, if no corrective action is taken in the pulse-shape and tracking data analysis procedures, a field strength ≳ 0.1 T will start to impact the intrinsic position resolution of 2 mm (RMS). At fields above ~1 T, the degradation of the energy response becomes observable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hierarchical Bayesian model for background variation in radiation source localization

In this paper, we apply a new model to account for varying background radiation in radiological source localization. We present a hierarchical Bayesian model that simultaneously infers background and source location parameters without requiring separate estimation of the background radiation at each detector location. We employ a simplified photon transport model to reduce the computational expense of Bayesian model calibration. Furthermore, we demonstrate the model accuracy by localizing a cesium-137 source in a simulated city block, and we analyze experimental field measurements with varying background. In both cases, the model provides sufficient fidelity that we can locate the source while simultaneously estimating background radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving the characterization of fusion in a MuSIC detector by spatial localization

Multi-Sampling Ionization Chambers (MuSIC) provide an efficient means of measuring nuclear reactions with low beam rates (< 10 6 pps). However, in comparison to thin-target measurements, prior measurements using MuSIC detectors all manifest fusion excitation functions with wide error bars in the energy dimension. This uncertainty limits the applicability of these devices in measuring near and sub-barrier fusion cross-sections. Key to overcoming this limitation is spatial localization of the fusion in the detector. By comparing the measured ionization in the MuSIC detector with accurate energy loss calculations the position of the fusion in the detector is determined. The analysis not only provides the desired improvement in energy resolution, but it also allows extraction of the atomic number of the evaporation residues following fusion. Furthermore, the effectiveness of this approach is demonstrated for 18 O+ 12 C measured with MuSIC@Indiana.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid neutron and gamma-ray source localization using machine learning

Rapid localization of radiation sources is critical for applications including nuclear emergency response, safeguards, and security. However, conventional imaging systems such as neutron scatter cameras and Compton cameras depend on rare coincidence events, which often result in long acquisition times. In this work, we address the challenge of rapid source localization by developing a machine learning approach to predict the direction of a single radiation source using only count rates from an array of neutron and gamma-ray detectors. The proposed model is a fully connected neural network (FCNN) trained using Monte Carlo simulation data from a 252 Cf source. The model hyperparameters are optimized with a small set of routine 252 Cf measurements. We benchmarked the performance of the trained and optimized machine learning model using additional 252 Cf , 137 Cs , and PuBe measurements under laboratory conditions with varying source-detector configurations. For these measurements, the machine learning model achieved a mean localization error smaller than 30° with 3 x 10 3 system counts, corresponding to 8 s measurement time for the imaging system used in this work. In this low-statistics regime, the method outperformed traditional scatter-based imaging by more than 75% in localization accuracy for the evaluated measurement configurations. These results demonstrate that a machine learning-based approach can significantly reduce the time required for accurate single-source localization, providing a robust and computationally efficient alternative to traditional imaging systems in time-critical nuclear security and emergency response scenarios.

Gamma-ray imaging↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Progress in end-to-end optimization of fundamental physics experimental apparata with differentiable programming

In this article we examine recent developments in the research area concerning the creation of end-to-end models for the complete optimization of measuring instruments. The models we consider rely on differentiable programming methods and on the specification of a software pipeline including all factors impacting performance — from the data-generating processes to their reconstruction and the inference on the parameters of interest — along with the careful specification of a utility function well aligned with the end goals of the experiment. Building on previous studies originated within the MODE Collaboration, we focus specifically on applications involving instruments for particle physics experimentation, as well as industrial and medical applications that share the detection of radiation as their data-generating mechanism. This report illustrates the most recent advancements in the area, and outlines, for each of the discussed applications as well as for automatic differentiation itself, ongoing and future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal Growth Scale-Up and Stability of RbSr 2 X 5 :Eu Scintillators

The discovery and development of new scintillation materials support national security needs. In these applications, large volumes of scintillator crystals are needed to achieve efficient screening for contraband. Therefore, one important step in the discovery of new scintillator compositions is testing their feasibility for scale-up and their stability. In this work, high-quality Ø22 mm crystals of two new scintillators RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu were grown via the Vertical Bridgman method, and their scintillation properties were characterized. Here, the Ø22 mm RbSr 2 I 5 :Eu crystals could be grown with fast translation rates up to 3.5 mm/h. Both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu had high scintillation performance, including light yields of 46,000 and 61,000 ph/MeV, respectively, for Ø22 × 35 mm crystals. Additionally, properties related to physical stability were investigated, including the coefficients of thermal expansion via high-temperature X-ray diffraction (HTXRD) as well as moisture sensitivity. HTXRD confirmed the absence of solid–solid phase transitions and showed that RbSr 2 Br 5 had minimal thermal expansion anisotropy compared to RbSr 2 I 5 and some other inorganic metal halide scintillators, which favors the growth of large-sized crystals.

36 MATERIALS SCIENCE↗

Light-Induced Currents at Domain Walls in Multiferroic BiFeO3.

Multiferroic BiFeO3 (BFO) films with spontaneously formed periodic stripe domains can generate above-gap open circuit voltages under visible light illumination; nevertheless the underlying mechanism behind this intriguing optoelectronic response has not been understood to date. Here, we make contact-free measurements of light-induced currents in epitaxial BFO films via detecting terahertz radiation emanated by these currents, enabling a direct probe of the intrinsic charge separation mechanisms along with quantitative measurements of the current amplitudes and their directions. In the periodic stripe samples, we find that the net photocurrent is dominated by the charge separation across the domain walls, whereas in the monodomain samples the photovoltaic response arises from a bulk shift current associated with the non-centrosymmetry of the crystal. The peak current amplitude driven by the charge separation at the domain walls is found to be 2 orders of magnitude higher than the bulk shift current response, indicating the prominent role of domain walls acting as nanoscale junctions to efficiently separate photogenerated charges in the stripe domain BFO films. These findings show that domain-wall-engineered BFO thin films offer exciting prospects for ferroelectric-based optoelectronics, as well as bias-free strong terahertz emitters.

36 MATERIALS SCIENCE↗

Laser Scribing for Electrode Patterning of Perovskite Spectrometer-Grade CsPbBr 3 Gamma-ray Detectors

Making semiconductor radiation detectors that work at room temperature relies heavily on the deposition and pixelation of electrodes. Electrode patterning of perovskite solar cells widely implements laser scribing techniques, which is a convenient, scalable, and inexpensive technique. However, this method has not found its application in radiation detector patterning yet, and the question whether laser scribing can achieve high-quality patterns with minimum damage to a detector crystal and low interpixel cross-talk remains largely unanswered. To prove that laser scribing is a practical method for electrode patterning on perovskite CsPbBr 3 detectors, we use the material to create a variety of patterns. A very low lateral leakage current (60 nA at 10 V) and high mobility-lifetime product (9.7(3) x 10 -4 cm 2 /V) were observed between the pixel and the guard ring in tests of single-pixel devices with a separation of 200 or 100 μm between the central electrode and the guard ring. The 122 and 136 keV photopeaks in 57 Co gamma-ray spectra were very well resolved with an energy resolution of up to 6.1% at 122 keV. Finally, a further reduction in gap size to 50 mu m is conceivable, but more process optimization is needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plastic Scintillators via Rapid Photoinitiated Cationic Polymerization of Vinyltoluene

Cationic photopolymerization is applied for the rapid curing of a vinyltoluene and fluorophore solution into an efficient plastic scintillator. A hard solid is obtained via UV light-initiated polymerization of vinyltoluene, diaryliodonium salt, 9,9-dimethyl-2-phenylfluorene (PhF), and 9,9-dimethyl-2,7-distyrlfluorene (SFS) at ambient conditions with high conversion rates under a range of cationic photoinitiator concentrations, fluorophore concentrations, and light intensities. Insight into photopolymerization kinetics via photo differential scanning calorimetry (photoDSC) revealed photocuring time scales similar to those achieved in a commercial 3D printing resin. Furthermore, scintillator samples prepared cationically performed well compared to samples of equivalent compositions prepared by a lengthy thermally initiated radical polymerization.

36 MATERIALS SCIENCE↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation Source Localization Using Surrogate Models Constructed from 3-D Monte Carlo Transport Physics Simulations

Recent research has focused on the development of surrogate models for radiation source localization in a simulated urban domain. We employ the Monte Carlo N-Particle (MCNP) code to provide high- delity simulations of radiation transport within an urban domain. The model is constructed to employ a source location (x, y, z) as input and return the estimated count rate for a set of speci ed detector locations. Because MCNP simulations are computationally expensive, we develop e cient and accurate surrogate models of the detector responses. We construct surrogate models using Gaussian processes (GP) and neural networks (NN) that we train and verify using the MCNP simulations. The trained surrogate models provide an e cient framework for Bayesian inference and experimental design. We employ Delayed Rejection Adaptive Metropolis (DRAM), a Markov Chain Monte Carlo (MCMC) algorithm, to infer the location and intensity of an unknown source. The DRAM results yield a posterior probability distribution for the source's location conditioned on the observed detector count rates. The posterior distribution exhibits regions of high and low probability within the simulated environment identifying potential source locations. In this manner, we can quantify the source location to within at least one of these regions of high probability in the considered cases. Employing these methods, we are able to reduce the space of potential source locations by at least 60%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise absolute 𝛾–ray intensities following the 𝛽 decay of 156 Eu

The most recent 𝛽-decay data for 156 Eu is over 40 years old, and the 𝛾-ray intensities are only known with a fractional precision of about 10% or worse. Here, in this work, we present new results for the absolute intensities of more than 60 𝛾 rays emitted following the 𝛽 decay of 156 Eu with many measured to ≲1% accuracy, representing an order-of-magnitude improvement in precision. This was achieved by leveraging the fission-product beams produced at the CARIBU facility to create radio-pure samples and detecting the radiation with a 4⁢𝜋 𝛽-particle counter coupled with a precisely efficiency-calibrated HPGe detector at Texas A and M University.

Physics - Nuclear physics and radiation physics↗

Prototype for Unclassified Algorithm

Continuing previous efforts to investigate and develop the Unclassified Radioisotope Algorithm, the goal of the FY19-FY20 effort was to develop a prototype detector system which uses the algorithm to confirm warhead attributes related to the presence of either weapons grade plutonium (WGPu) or highly enriched uranium (HEU). The final deliverable is a prototype attribute measurement system built with common, commercially available gamma radiation detector components, capable of confirming the presence of specific, complex radioactive sources of interest, without the collection and storage of gamma energy spectra. This is accomplished by processing each gamma pulse as it is received, applying weight values based on the energy and incrementing or decrementing scalar counters which can be compared with expected values to determine if the measured source is consistent with WGPu or HEU. This report documents the design of the prototype system as well as the development of the algorithm and performance testing results. While the previously conceptualized, simple algorithm resulted in a prohibitive amount of false positives, the goal for a simple attribute measurement system capable of verifying Ba-133 and Ra-226 (weapons grade plutonium and highly enriched uranium surrogate testing sources) at over 95% accuracy with sub 5% false positive rate was demonstrated.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗