Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RECOILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Low-Energy Backgrounds in Solid-State Phonon and Charge Detectors

Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy depositions, uncovering previously unseen low-energy excess backgrounds. While some arise from known processes such as thermal radiation, luminescence, and stress, others remain unexplained. This review examines these backgrounds, their possible origins, and parallels to low-energy effects in solids, an understanding of which is essential for interpreting particle interactions at and below the eV scale.

coherent neutrino–nucleus scattering↗

SCULPT (Supervised Clustering and Uncovering Latent Patterns with Training) v1

SCULPT (Supervised Clustering and Uncovering Latent Patterns with Training) is a comprehensive data visualization and analysis application focused on working with COLTRIMS (COLd Target Recoil Ion Momentum Spectroscopy) data, which is used in atomic and molecular physics experiments. The application offers several powerful features: - Data uploading and processing capabilities for COLTRIMS files - Multiple visualization methods using UMAP (Uniform Manifold Approximation and Projection) for dimensionality reduction - Interactive selection of data points across multiple views - Feature engineering through various methods: - Manual feature selection from calculated physics parameters - Deep autoencoder for dimension reduction - Genetic programming for discovering meaningful features - Mutual information-based feature selection - Multiple clustering approaches (DBSCAN, KMeans, Agglomerative) - Quality metrics for evaluating clustering results - Export capabilities for selections and generated features

Daoud, Hazem [Lawrence Berkeley National Laborator↗

Development of 225Ac-doped biocompatible nanoparticles for targeted alpha therapy

Abstract Targeted alpha therapy (TAT) relies on chemical affinity or active targeting using radioimmunoconjugates as strategies to deliver α-emitting radionuclides to cancerous tissue. These strategies can be affected by transmetalation of the parent radionuclide by competing ions in vivo and the bond-breaking recoil energy of decay daughters. The retention of α-emitting radionuclides and the dose delivered to cancer cells are influenced by these processes. Encapsulating α-emitting radionuclides within nanoparticles can help overcome many of these challenges. Poly(lactic- co -glycolic acid) (PLGA) nanoparticles are a biodegradable and biocompatible delivery platform that has been used for drug delivery. In this study, PLGA nanoparticles are utilized for encapsulation and retention of actinium-225 ([ 225 Ac]Ac 3+ ). Encapsulation of [ 225 Ac]Ac 3+ within PLGA nanoparticles (Z ave = 155.3 nm) was achieved by adapting a double-emulsion solvent evaporation method. The encapsulation efficiency was affected by both the solvent conditions and the chelation of [ 225 Ac]Ac 3+ . Chelation of [ 225 Ac]Ac 3+ to a lipophilic 2,9-bis-lactam-1,10-phenanthroline ligand ([ 225 Ac]AcBLPhen) significantly decreased its release (< 2%) and that of its decay daughters (< 50%) from PLGA nanoparticles. PLGA nanoparticles encapsulating [ 225 Ac]AcBLPhen significantly increased the delivery of [ 225 Ac]Ac 3+ to murine (E0771) and human (MCF-7 and MDA-MB-231) breast cancer cells with a concomitant increase in cell death over free [ 225 Ac]Ac 3+ in solution. These results demonstrate that PLGA nanoparticles have potential as radionuclide delivery platforms for TAT to advance precision radiotherapy for cancer. In addition, this technology offers an alternative use for ligands with poor aqueous solubility, low stability, or low affinity, allowing them to be repurposed for TAT by encapsulation within PLGA nanoparticles. Graphical Abstract

60 APPLIED LIFE SCIENCES↗

Cherenkov and Transition Radiation as Low-Energy Background Sources in SuperCDMS Detectors

The Weakly Interacting Massive Particle (WIMP) has historically been a prime candidate for dark matter due to its elegant compatibility with the Minimally Supersymmetric Standard Model (MSSM). Recent dark matter experiments have ruled out much of the GeV-TeV mass range predicted by the MSSM, however, and the newest generation of direct detection experiments, such as SuperCDMS SNOLAB, have begunto explore sub-GeV dark matter. As experiments push towards lower masses, sensitivity to eV-scale electron recoil events has become increasingly important. A variety of unexplained excesses at energy deposits of 1-100 eV have been found inmany such low-mass experiments, across different detection techniques and at different excess rates. These low-energy events are not thought to be dark matter, and they must be understood and effectively removed to further improve detector energy resolution. This thesis will outline the simulation of one possible source of low-energy excess at SuperCDMS: optical photons produced from charges in uniform motion, specifically from Cherenkov radiation (CR), transition radiation (TR), and the intermediate hybrid transition-Cherenkov radiation (HR). In the latter case, the standard formulae for HR contain divergences at certain angles in transparent media, which are an artifact of their derivation and become problematic to simulate. To rsolve this, we present a novel approach to normalize the divergent HR peaks, which allows HR to transition smoothly between TR and CR in a numerical simulation. We also add TR and CR as a physics process to the SuperCDMS Monte Carlo simulation package SuperSim, based on the Geant4 simulation toolkit. To verify the physics of our addition, we show some test simulations in comparison to theoretical predictions of optical radiation intensity. We also use the simulation to make some preliminary predictions on the contribution of TR and CR to the low energy background, with the expectation that more thorough analyses will be conducted in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expansion of the Fast Neutron Hodoscope at TREAT to Support Fuel Safety Experiments

In 2024 the Fuel Motion Monitoring System (FMMS), or Hodoscope, at the Transient Reactor Test Facility, is being expanded from 96 viewing channels to 192 viewing channels, effectively doubling the FMMS field of view. Here, this increase in capability will allow the FMMS to support larger scale fuel tests, encompassing height-of-core test devices, test devices with multi-pin fuel assemblies, and test devices with recirculating coolant flow. Work supporting the expansion included refurbishing 96 additional proton recoil scintillator (PRS) detectors, doubling the data acquisition system (DAS) installed architecture, improving time synchronization in the DAS, and new research to measure the PRS detector energy-dependent, fast-neutron detection efficiency. In addition, laboratory activities have produced an improved benchtop testing capability for assessing the DAS, time synchronization, and external start triggering, along with an updated capability to scan PRS detectors to develop a preliminary flat-field normalization prior to deployment to TREAT.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Even lighter particle dark matter

We report on recent progress in the search for dark matter particles with masses from 1 Mev c ^{-2} − 2 to 1 Gev c ^{-2} − 2 . Several dark matter candidates in this mass range are expected to generate measurable electronic-recoil signals in direct-detection experiments. We focus on dark matter particles scattering with electrons in semiconductor detectors since they have fundamentally the highest sensitivity due to their low ionization threshold. Charge-coupled device (CCD) silicon detectors are the leading technology, with significant progress expected in the coming years. We present the status of the CCD program and briefly report on other efforts.

Chavarria, Alvaro E.↗

Dark matter searches and energy accumulation and release in materials

Efforts to identify dark matter by detecting nuclear recoils produced by dark matter particles reveal low-energy backgrounds of unknown origin in different types of detectors. In many cases, energy accumulation and delayed burst-like releases of stored energy could provide an explanation. These dynamics follow Prigogine’s ideas on systems with energy flow and the general Self-Organized Criticality scenario. We compare these models with properties of excess backgrounds in cryogenic solid-state detectors, relaxation processes in glasses and crystals, our observations of delayed luminescence in NaI(Tl), and make predictions for more phenomena present in these systems and in superconducting photon detectors and qubits. Experiments to create accurate phenomenological models are needed.

Pereverzev, Sergey↗

Study of light nuclei by polarization observables in electron scattering

Electron-induced proton, neutron and deuteron knock-out remains the most versatile probe of the electro-magnetic properties and spin structure of light nuclei. The advent of highly polarized beams and targets and improvements in recoil polarization methods, as well as analysis and simulation techniques, have enabled us to study the static and dynamical properties of few-body systems with unprecedented precision. Recent experiments at Jefferson Lab and MAMI are presented and put into perspective of state-of-the art Faddeev calculations, with focus on the ^\mathbf{3}\mathbf{He} 3 𝐇 𝐞 nucleus.

Sirca, Simon↗

Surface Analysis and Hydrogen Permation Measurements for Super-Permeating Membrane Materials

In this report, we summarize preliminary surface characterization results for Nb surfaces, using low energy ion scattering, direct recoil spectrometry, and Auger electron spectroscopy. While most surface analysis tools cannot detect hydrogen, the low energy ion beam techniques described here are among the few techniques that are directly sensitive to it. For this study, we examined chemisorption using both molecular and atomic hydrogen (using an heated tungsten capillary to dissociate the hydrogen.) To complement these results, we have been performing ex-situ spectroscopic ellipsometry as a means of detecting the surface oxide.

36 MATERIALS SCIENCE↗

Effects of nitrogen on tungsten surfaces investigated with low energy ion scattering

The effect of nitrogen on the surfaces of polycrystalline ITER-grade tungsten and a tungsten single crystal were studied with low energy ion scattering (LEIS) and direct recoil spectroscopy (DRS). LEIS and DRS measurements on both tungsten surfaces were performed in an ultra-high vacuum system as various quantities of N 2 were introduced into the chamber through a variable leak valve. The obtained ion energy spectra reveal that nitrogen was readily adsorbed onto the surface, in turn limiting the amount of hydrogen that could be adsorbed onto the surface. These results not only provide insight into how the presence of nitrogen on tungsten surfaces may play a role in hydrogen adsorption and retention, but also serve to benchmark models being developed to describe the H-N-W system.

36 MATERIALS SCIENCE↗

Cryogenic Detector Development for SuperCDMS

The dark matter (DM) problem is currently one of the most pressing issues facing physics. This thesis presents some of my work and contributions to the detectors employed by the Super Cryogenic Dark Matter Search (SuperCDMS), one of the many experiments currently investigating DM. First, we present an overview of astrophysical and cosmological observations to give insight into our current understanding of DM and its role in the universe. Some potential particle DM candidates are also discussed. Then we describe the SuperCDMS experiment and relevant detector technologies. We go into particular detail in discussing the phonon sensors, deriving the relationships that define their fundamental working principles and describing their practical deployment. We also discuss the main noise contributions to the phonon sensors which can limit experimental sensitivity. We then present some work related to reconstruction of event position in the detectors, including new analysis techniques and a n ovel cryogenic calibration source mover we have developed and tested. We also present tests of improving experimental scalability by increasing individual detector masses using the largest-diameter cryogenic Si detectors yet operated. We present first experimental results from the novel use of $(n,\gamma)$ processes to calibrate the low energy nuclear recoil energy scale. This work is essential to understand how DM-nuclear interactions will manifest in semiconductor detectors. We also take a short look at the newest, most sensitive detectors currently operated by SuperCDMS and discuss how they are allowing new insights into critical physics processes in all SuperCDMS detectors. Finally, we demonstrate how some of the various improvements discussed in this work can improve the experimental reach of the next generation of SuperCDMS at SNOLAB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Contributions to the BeEST sterile neutrino search

Sterile neutrinos are hypothetical right-handed leptons that have been postulated as extensions to the Standard Model to help explain the origin of neutrino masses and the matter-antimatter asymmetry in the Universe. Sterile neutrinos with keV-scale masses are also a promising candidate for dark matter. LLNL and the Colorado School of Mines are developing an experiment to search for sterile neutrinos by measuring the \Beryllium-7 Electron capture in Superconducting Tunnel junctions (STJs)" (the \BeEST" Experiment). When 7 Be implanted into STJ radiation detectors decays by electron capture, the neutrino escapes and the energy of the recoiling 7 Li nucleus can be measured with high accuracy. Using conservation of energy and momentum, the mass of the emitted neutrino can then be found. Sterile keV neutrinos would generate additional peaks in the spectrum, and the experiment uses high-resolution STJs to observe such a potential signal. During my internship, I contributed to different aspects of the BeEST experiment. I designed a UHV setup for X-ray spectroscopy analysis with STJs. It will allow high-resolution X-ray spectroscopy of different materials to examine the broadening in the BeEST spectra, the origins of which are unknown but may be related to material effects inside the STJ detectors. The design accounts for the specific demands of the BeEST project, but provides a degree of flexibility that makes it useful for other potential STJ projects. Additionally, to test the accuracy of the electronics and data analysis routine, an arbitrary waveform generator (AWG) will be used to generate simulated spectra that contain sterile neutrino signals of a specified mass and admixture. For this I programmed an AWG to output random STJ signals whose amplitudes follow the appropriate user-de ned probability distribution. The AWG signals can be input into the 32-channel preamplifier to simulate any spectrum of interest and test the uniformity of the amplifier chain, as well as the sensitivity of the data analysis.

42 ENGINEERING↗

Search for dark matter decaying to two displaced muons produced in proton-proton collisions at 13 TeV with the CMS detector, and for dark photons produced in electron-positron fixed-target collisions at 500 MeV with the PADME detector

Two novel searches for dark matter using particle accelerators are presented. The first is a search for inelastically-coupled dark matter with the CMS detector at CERN, relying on 137 fb$^{-1}$ of proton-proton collision data collected at 13 TeV center-of-mass energy between 2016 and 2018. The search strategy exploits the striking signature expected of inelastic dark matter: a pair of displaced, soft, and narrow muons collimated with missing transverse momentum and recoiled off an initial-state radiation jet. This is the first search for inelastic dark matter at a hadron collider. The second experiment is PADME, a small-scale detector to search for dark photons located in Frascati, Italy. PADME seeks to detect the production of dark photons in positron-electron collisions with a stationary diamond target and a 500 MeV positron beam. The missing-mass technique employed in the experiment relies on constraining all four-momenta in the system except for the dark photon and lookin g for a bump in the resulting invariant mass distribution corresponding to the dark photon's mass. The projected sensitivity for both experiments is compared in the context of highlighting the need for a comprehensive experimental search program for dark matter. Both analyses expect first public results by the end of 2020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Spectrum and 10B(n,α) Measurements in ZPPR-15

Neutron spectra were measured at the core center with proton recoil spectrometers in ZPPR15A loading 66, ZPPR-15B loading 90 and ZPPR loading 186. In addition, neutron spectra were measured in the SSNA shield configuration in ZPPR-15B loading 121 and in the BCNA shield configuration in ZPPR-15B loading 126. The ZPPR-15 neutron spectrum measurement and data processing techniques were described and analyzed. Total uncertainties were derived for all five spectrum measurements. A back-to-back proportional counter was used to measure the 10 B(n,α) reaction rate at six locations in the simulated shield, radial reflector and outer core in the ZPPR-15B BCNA shield experiment. The measurements were described and analyzed. A total uncertainty was derived for the 10 B(n,α) reaction rate measurements. The ZPPR-15 experimental records were used to develop detailed as-built Monte Carlo models for the five neutron spectrum measurement configurations and for the six 10 B(n,α) measurement configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Laboratory and Astrophysical Probes of Physics Beyond the Standard Model (Final Technical Report)

The first of these directions centers on new ideas in dark matter detection. As experimental scrutiny narrows the window for new physics at the weak scale, it has become apparent that the solution to the dark matter mystery may not reside there. Theoretical developments such as the hidden sector/valley paradigm have, at the same time, shown that compelling theories of dark matter reside below the weak scale. Searching for dark matter at lower mass scales requires looking beyond the current paradigm of dark matter direct detection based on nuclear recoils. It is the goal of this project to provide new ideas to guide the experimental program looking for light dark matter. I am actively proposing ideas for detecting dark matter as light as a meV, well beyond the current focus of GeV-TeV scale dark matter. Some of the ideas I have proposed, such as superconducting, superfluid, and polar material targets, are actively being developed into experiments. My group will provide the relevant calculations to determine dark matter reach, providing crucial input to experiment on which targets should be developed. We will also provide an effective field theory framework to understand which types of experiments are most sensitive to each interaction type. The second of these directions is on probes of dark matter substructure as a mean to constrain, or observe, models of dark matter. The standard ΛCDM paradigm assumes that the dark matter density perturbations are adiabatic, scale invariant, and produced during inflation. However, many standard models of dark matter will produce modifications of this prediction, such as axion models with symmetry broken below the inflationary scale. Remarkably, we have limited direct measurements of the dark matter clumpiness at mass scales below dwarf galaxies. This allows for the possibility of observing modifications from vanilla ΛCDM due to particle dynamics. In many cases, simulations of dark matter structure in the presence of non-scale invariant fluctu- ations are understudied or completely lacking. I plan to develop both theoretical predictions for small scale structure in models with additional matter power on small scales, as well as observa- tional probes of small scale halos or clumps. One idea I have been recently focused on is pulsar timing, though my group will pursue a variety of lensing and astrometric probes. Lastly, the most risky direction involves spacetime fluctuations from quantum gravity. I showed that if one assumes that metric fluctuations in the Minkowski vacuum, at a surface separating a region in and out of causal contact (which we call a “horizon”), are determined by standard thermodynamic considerations at horizon, these metric fluctuations are large enough to observe in an interferometer with similar sensitivity to LIGO. In a follow-up paper we showed that these assumption holds for the vacuum in AdS/CFT. In future work, I plan to connect this work to recent soft graviton results, to frame this work in a concrete Randall-Sundrum model, and to work out concrete phenomenological predictions from the model. This work unquestionably takes a less trodden path, and works well as part of a well-rounded portfolio of less and more risky ideas. Particle physics is currently at a juncture which requires bold exploration of qualitatively new directions. This proposal outlines some of my plans over the coming years in these directions, leaving room also for surprises.

79 ASTRONOMY AND ASTROPHYSICS↗

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ellipsoidal Fitting Methodology for Defect Clusters in Gallium Arsenide

In assessing the initial spatial distribution of defects from neutron or heavy ion irradiation, it is useful to have a reliable, automated, and fast-running tool to evaluate characteristic metrics such as the number of sub-clusters or the overall cluster volume. The latter metric, for instance, can be utilized to estimate a reference neutron fluence level at which inter-cluster interaction effects begin to become significant. This paper details a methodology to fit an arbitrarily complex defect map with a set of ellipsoids (one per identified sub-cluster) in which the constituent defects of a sub-cluster are determined using fuzzy degree-of-membership analysis. Specifically, a parameterized model is developed for point defects in gallium arsenide. Cluster volume calculations based on the model are compared against convex hull and single- ellipsoid representations. Results show that the parameterized sub-cluster model begins to deviate from the two reference models at a recoil energy of about 100 keV in GaAs, with the convex hull and single-ellipsoid representations increasingly overestimating the volume thereafter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hunting Sub-GeV Dark Matter with Diamonds and Magnetic Microcalorimeters Principle

This project is to study feasibility of a new concept for the sub-GeV dark matter (DM) detection using diamond crystals and magnetic microcalorimeters (MMCs). Diamond crystals are made of low mass carbon constituent that maximize kinetic energy of nuclear recoils from sub-GeV DM scattering due to their relatively similar masses. MMC is employed as a sensitive phonon sensor to measure athermal phonons that are produced by DM scattering in diamond crystals with 100 ns timing resolution and ~10 eV energy resolution. MMC’s fast timing resolution allows high precision phonon pulse shape analysis to separate out unwanted background or noise signals in the low energy region at E < 1 keV. Especially, the low energy excess (LEE) problems have been reported in the dark matter detection community and the proposed diamond-MMC detector might be able to provide important information to understand the origins of LEE signals in DM detectors. In this project a diamond-MMC detector has been built for proof-of-concept experiments and athermal phonon collection efficiencies have been investigated for single crystal and poly-crystal chemical-vapour-diamonds (SC and PC CVDs) as well as reference sapphire crystals are tested in the same geometries to quatify athermal phonon propagation and their collection to the MMC phonon sensors. Athermal phonon collection efficiencies and their lifetime in the diamond and sapphire crystals are successfully measured in the same geometry and experimental setup for comparison. SC CVD crystals exhibit poorer performance than the sapphire reference crystals in athermal phonon collection, while the PC CVD crystal exhibit better result than the sapphire. PC CVD with MMC phonon sensors would be feasible for sub GeV DM detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗