Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOACTIVE CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Reducing the Risk of Airborne Contamination through Intelligent Container Surveillance

DOE Manual 441.1-1 provides a set of performance criteria that nuclear material storage containers must achieve to provide protection to the worker, public, and environment. At Los Alamos National Laboratory, the SAVY-4000 is the container of choice for nuclear material storage, meeting all Manual requirements. At the outset, polymer components of the SAVY 4000 were considered to be life-limiting components due to their performance degradation resulting from radiation exposure. However, recent annual surveillance results revealed another life-limiting phenomenon for the container: a deterioration of the package integrity through corrosion of the stainless steel components, primarily the body. Container surveillance remains the choice method of observing, measuring, and tracking container health in service.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Emulsified Oil Bio-Barrier to Remediate CEE in the Distal Portion of a Groundwater Plume - 20210

A non-time critical (NTC) removal action (RA) was designed at the Savannah River Site (SRS) to inject an emulsified oil mixture with a bioaugmentation culture to prevent trichloroethylene (TCE) discharging to surface water above maximum contaminant levels (MCLs). The emulsified oil mixture is expected to sequester the TCE and then be broken down into harmless compounds through microbial biodegradation. At 15 locations 8,290 L (2,190 gal) of oil mixture, buffer and chase water were injected into the subsurface creating two bio-barriers. At each location half of the oil mixture was injected, then 2 L (0.528 gal) of an enriched bioaugmentation culture was injected, and then the second half of the oil mixture was injected into the subsurface. Finally, at each location 151 L (40 gal) of buffer mixed with 575 L (200 gal) of dilution water was then injected followed by 1,135 L (300 gal) of chase water. SRS estimates this created two emulsified oil barriers totaling 73 m (240 ft) long, approximately 3 m (10 ft) high and 4.9 m (16 ft) wide in the subsurface. Similar emulsified oil barriers have been effective for 3 to 5 years, and SRS anticipates a similar longevity for these barriers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Role of uncertainties in protecting ecological resources during remediation and restoration

Cleanup of contaminated waste sites is a National priority to protect human health and the environment, while restoring land to productive uses. While there are uncertainties with under standing risk to individuals from exposure, the aim of this study was to focus on uncertainties and complexities for ecological systems, complicated by hundreds of species occupying any remediation site which participate in multiple-interacting food webs. The ability to better predict the effectiveness of remediation in fostering future ecosystems might facilitate remedy selection and improve strategic environmental management. This investigation examined (1) uncertainties in ecosystem processes, (2) uncertainties in exposure from contamination before remediation, and (3) uncertainties during remediation. Two Department of Energy sites Hanford Site and Savannah River Site were used as case studies to illustrate how the uncertainties affect eco-receptors. Several types of ecological, physical, and human dimension uncertainties are defined. Ecological uncertainties include temporal, spatial, individual, developmental, and exogenous types. Physical uncertainties are weather-related, watershed variations, slope/aspect, soil/sediment structure and form, unforeseen events, and temporal patterns. Human dimension uncertainties include current land use, future land use, extractive and non-extractive recreation. The effects of remedial strategies varied between the two sites because Hanford is a primarily arid shrub-steppe ecotype, while Savannah River is a wet forest ecotype. Defining the associated ecological sensitivities and uncertainties and providing examples might help policy-makers, managers, planners, and contractors to be aware of issues to consider throughout planning, remediation, and restoration. Adding ecological uncertainty analysis to risk evaluations and remediation planning is analogous to using safety factors in human health risk assessment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Natural attenuation of uranium in a fluvial Wetland: Importance of hydrology and speciation

A nuclear fuel fabrication facility released 43,500 kg of uranium into a riparian wetland located on the Savannah River Site between 1955 and 1988. Studies were undertaken to evaluate hydrological and geochemical processes influencing uranium accumulation in the wetland. Gamma-radiation-mapping surveys were conducted by systematically walking over the contaminated wetland with backpacks equipped with global positioning systems and NaI gamma detectors. Based on maps compiled from >700,000 gamma spectra and eight sediment uranium depth profiles, it was determined that 94% of the released uranium remained in the wetland. The uranium in the wetland is concentrated in five multi-hectare areas along the stream, accounting for ~11% of the land area adjacent to the stream. While land type (upland or wetland) and topography provided a reasonable first approximation of where much of the uranium was deposited, hydrological watershed modeling revealed that the stream velocity was especially slow through many of the hot spots. Here, using autoradiography combined with SEM/EDX measurements of contaminated sediments, surprisingly few hot particles were detected. Instead, uranium was evenly distributed throughout the sampled sediment, suggesting that dissolved uranium had bound to sediment particles that became suspended and later deposited in low energy (low flow velocity) portions of the stream. EXAFS suggested that U atoms were present as individual ions in disordered complexes within the sediment. Furthermore, linear combination analyses suggested that the predominant component of the U(VI) was adsorbed to sediment minerals (~70%) and a minor component (~30%) was associated with organic matter phases. Furthermore, these studies show that wetlands can be extraordinarily effective at binding and retaining uranium, thereby providing a natural barrier to the transport of uranium out of a watershed. However, significant anthropogenic or climatic changes to wetlands, such as those associated with flooding, forest fires, or land use, may disrupt the complex hydrological and biogeochemical balance necessary to maintain long-term immobilization of uranium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of Speciation Determination Measurements of Insulating Sulfur Hexafluoride Gas

Under the direction of the NNSA NA-231 Mo-99 Program, SRNL has provided technical assistance to U.S. companies under cooperative agreements. One such area of technical assistance has been for the recommendation for contamination management methods in the eventuality that tritium contaminates the insulating gas of a high-voltage ion source used in the accelerator-based process developed by SHINE Medical Technologies to produce Mo-99. The SHINE accelerator process uses tritium as the target of a deuterium ion beam, where the ion beam is produced within a high-voltage ion source insulated with sulfur hexafluoride (SF 6 ), and is separated from the tritium target by an extensive pump train. Normal operating conditions preclude the conditions necessary for contamination of the insulating gas, however certain atypical conditions could result in a tritium contamination event. Accelerator based processes for medical isotope production represent an anomalous tritium contamination challenge due to the presence of SF 6 . SF 6 decomposes through normal use as an insulator gas, and the exact speciation of the decomposition byproducts depends on a variety of factors. This creates a scenario where the anticipation of species present in the insulating gas mixture is difficult. In turn, the fate of tritium within such a chemical system is unclear. This document discusses the results of measurements made in-situ of the SF 6 insulating gas in use within a SHINE Medical Technology’s high-voltage ion source. This was done in an effort to determine the chemical speciation of the gas, allowing for the recommendation of management strategies in the event that tritium contaminates the insulating gas. The results of the measurements reported in this work suggest that tritium contamination in the insulating gas may result in two chemical forms of tritium in the system, tritiated water and molecular tritium. These two forms of tritium would be captured by two methods. Tritiated water may be captured and removed from the SF 6 by an adsorbent canister already present within the pressure vessel that houses the insulating gas while in use. It may also be separated from the SF 6 during routine purification of the SF 6 , which is performed by SHINE personnel routinely. The purification cart will perform all non-embedded systems cleanup necessary to remediate tritiated species in the system. The purification cart passes the insulating gas through several filters, followed by the liquefication of the SF 6 . The filters will separate tritiated water from the SF 6 at this stage. It is expected that molecular tritium will accumulate in the gas-phase during the liquification step, which is separated and stored. Tritium may be recovered from this mixture through more conventional hydrogen purification methods such as a palladium diffuser.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Guidance for Monitoring Passive Groundwater Remedies Over Extended Time Scales

Passive remediation can be appropriate where natural processes and actions such as institutional controls mitigate exposure to contaminated groundwater, achieving remedial action objectives and protectiveness of human health and the environment. Monitored natural attenuation (MNA) is a prevalent passive remediation strategy supported by a regulatory framework and monitoring design guidance. MNA can also be used after active remediation has been completed (e.g., pump-and-treat) as a polishing step to reach ultimate remedial action objectives. However, MNA and existing monitoring guidance primarily target situations where the remedial action objectives are met within a few decades. When timescales for passive remediation extend to many decades, a corresponding change in monitoring strategy is needed to adapt to the extended time scale. This document provides guidance for implementing an extended-scale monitoring (ESM) approach appropriate for long-duration passive remediation. Extended-scale is defined in this document with respect to time (i.e., a long duration of remediation) and a large enough physical scale such that receptors will not be impacted within the remediation timeframe.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ALARA Review for Venting of Flanged Tritium Waste Containers (FTWCs) at TA-54

This project will vent headspace hydrogen and oxygen from specialized high-pressure storage vessels called flanged tritium waste containers (FTWCs). There are four of these containers located in Los Alamos National Laboratory’s (LANL’s) Technical Area 54 (TA-54), Building 1028. This building is in the southwest corner of LANL’s Material Disposal Area G. The vented headspace gas is expected to contain tritium in the form of water vapor, elemental hydrogen or a combination of both. The venting operation is expected to take place in 2025. There will be a series of operational readiness reviews prior to venting activities commencing. The FTWCs at TA-54 contain tritium-contaminated metal parts and molecular sieve media, which is a pebble-like material used to absorb water vapor from the air. This molecular sieve media inside the FTWCs is contained in metal canisters, along with some loose media material in bags. Over time, tritiated water vapor that had been adsorbed onto the media can become liberated into the FTWC headspace gas. Radiolysis can cause separation of the water vapor into its hydrogen and oxygen components, resulting in the potentially hazardous gas mixture within the FTWC. LANL has determined that continued tritium storage in these containers can pose an unsafe condition due to possible hydrogen and oxygen gas buildup within the FTWCs with a potential for explosion if sparks are generated within the FTWCs. To mitigate this hazard, the FTWCs will be stabilized by venting them in-place to remove hazardous gases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building 100 Groundwater Bioremediation at the Former DOE Pinellas Plant, Florida: Review of Progress and Opportunities

Weapons research, development, and production operations at the former Pinellas Plant, which includes the Building 100 area, released chlorinated organic solvents into the subsurface, contaminating the underlying soil and groundwater. The site was sold to Pinellas County and is now home to a thriving industrial park known as the Young - Rainey Science, Technology, and Research (STAR) Center. The US Department of Energy (DOE) has applied bioremediation at the Building 100 Area as a key technology to clean up the chlorinated volatile organic compound (cVOC) contamination in soil and groundwater. The monitoring data indicate significant progress toward remedial objectives over the past two decades. Starting conditions in the 1980s-1990s included areas containing residual undissolved dense nonaqueous phase liquids (DNAPLs) and the associated presence of an extensive high concentration plume in the groundwater. The original parent cVOCs were primarily tetrachloroethene (PCE) and trichloroethene (TCE). After several informative pilot studies, bioremediation was implemented at the Building 100 Area of the site and relies on reductive biological pathways and the sequential removal of chlorine from the parent cVOCs forming dichloroethane (DCE) and chloroethene (vinyl chloride, VC). As bioremediation sites evolve toward cleanup, the trends in VC concentrations often serve as a critical indicator for progress and remediation timeframe because VC typically has a lower concentration target remedial objective (nominally 1 to 2 μg/L) compared to PCE and TCE (nominally 3 to 5 μg/L).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential Advantages to Employing an Onsite Laboratory at FUSRAP Sites Contaminated with Radionuclides and Metals - 20353

Various factors that support an evaluation of the relative costs, advantages and disadvantages of utilizing an onsite laboratory or an offsite laboratory for remediation of Formerly Utilized Sites Remedial Action Program (FUSRAP) sites contaminated with radionuclides and metals are presented. In terms of how much more quickly an onsite laboratory provides results versus an offsite laboratory, the results of this study provide tools for calculating the amount of cost savings per day for excavation of contaminated soils for various scenarios including: - State, municipal or local property remediation where the remediation schedule becomes time-critical due to the extra cost and inconvenience to the town or municipality caused by the need for increased security and safety personnel, possible road closures and detours, and the inconvenience to the public due to modified or decreased services of State or municipal facilities; - Residential property where the remediation schedule becomes time-critical due to the inconvenience to the homeowner as well as the importance of maintaining good community relations; - Commercial property where the remediation schedule becomes time-critical due to the hardship and potential loss of revenue endured by the property owner; - Open area where treatment of excavation water is required, and - Open area where treatment of excavation water is not required. For every scenario, the number of matrices, radionuclide and metal contaminants of concern and the project duration are important factors. The costs for the onsite laboratory included the capital costs associated with setting up the lab such as trailer(s) or building(s), power and water hookup, analytical testing equipment, balances, computers, desks and bookcases; support equipment such as hot plates, filtration assemblies, safety equipment, ovens, etc.; and supplies such as glassware, pipettes, filters, etc. and ongoing costs such as labor, chemicals and reagents, standards, cost of the laboratory obtaining certification and maintenance. Offsite laboratory sample testing costs are generally very competitive and typically substantially lower than onsite laboratory costs if only the sample testing costs are considered. The great disadvantage of using an offsite laboratory is that they often cannot guarantee rapid turnaround times for results which creates project delays associated with the remediation process including delays determining the completeness of the characterization and remediation processes, delays in backfilling a property and additional costs for treating wastewater (excavation water, stormwater or both). These costs will vary greatly depending upon the area of the country in which the project is located due to the wide range of labor costs for the onsite laboratory and field workers, as well as the contaminants of interest, matrices and most importantly the size of the impacted area and the number of properties located in that area. This paper provides guidelines for calculating the cost savings that may be realized if an onsite laboratory can generate results more quickly than an offsite laboratory by estimating the costs associated with the remediation process for the various scenarios noted above such as work crew labor costs, excavator and dump truck equipment rentals, wastewater treatment costs (if applicable) and the additional costs incurred by homeowners, commercial property owners and towns/municipalities that are reimbursed by the potentially responsible parties. Key assumptions involve the typical quickest turnaround time provided by the onsite and offsite laboratories. Costs for the operation of a wastewater treatment system and the remediation of a site area or property were provided by personnel who have been involved in the operation of a large FUSRAP site in New Jersey for many years. This study provides valuable information for determining the most cost-effective approach for analysis of project samples and therefore may be used on upcoming FUSRAP projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Center for Performance and Design of Nuclear Waste Forms and Containers (WastePD) Energy Frontier Research Center (Final Report)

The DOE Office of Environmental Management is responsible for high level nuclear waste that must be safely isolated from humans and the environment for extremely long periods. The waste forms and containers are made of glass, ceramics, and metals. Verified safe disposal requires understanding the fundamental mechanisms of waste form degradation and the design of new waste forms with improved performance, which comprise the goals of the Energy Frontier Research Center known as the Center for the Performance and Design of Nuclear Waste Forms and Containers, WastePD. WastePD was constructed to develop innovative approaches and solutions to those goals through the synergistic interactions of individuals who are experts in the degradation behavior, modeling, and design of glasses, ceramics and metal alloys. WastePD is the first center ever created to address this diverse group of materials in a comprehensive and coordinated manner. The science goals are grouped into three common topics: corrosion mechanisms via advanced characterization, environmental impacts, and materials design. Synergistic interactions in these areas were a key component of WastePD. The fundamental understanding of the degradation mechanisms of the waste forms and containers as well as the development of new materials with improved properties will allow DOE to prevent environmental contamination and to explore totally new repository concepts. WastePD was operational from August 2016 through July 2022, but the DOE support was drastically reduced for the last two years. This final technical report covers the full period of performance. However, much of what was accomplished in the first four years is nicely summarized in a review paper published in 2021, which is appended to this report. Therefore, this final report focuses on the technical findings from the last two years of WastePD activities. Considerable progress was made in the areas of a) the environmental and compositional impacts on the corrosion of borosilicate and aluminosilicate glasses, b) the mechanism of glass corrosion and the structure and evolution of the surface alteration layer, c) the effects of environment and composition on the corrosion of pyrochlore, perovskite, hollandite, and other oxide ceramics, d) the corrosion mechanism of multi-principal element metallic alloys, and e) a new framework for understanding the pitting corrosion of metals.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FX Hg Fogging Fixative Deployment for Mercury Vapor Suppression

Idaho National Laboratory’s (INL) FX Hg fixative solution was deployed at the Y-12 Complex in Oak Ridge, Tennessee to support disposal of mercury-contaminated metal debris. The fixative was dispensed via fogging. Fogging infiltrates non-line-of-sight areas improving fixative coating on complex geometries such as debris piles. FX Hg is the mercury vapor controlling derivative of INL’s FX2 fixative. FX2 was jointly developed with the National Nuclear Laboratory of the United Kingdom, and INL developed the FX Hg derivative to suppress mercury vapor generation. The Y-12 deployment was performed in concert with cleanup contractor UCOR. A dumpster filled with debris was fogged with FX Hg. The material was acceptable as municipal landfill waste, save for the mercury vapor levels measured. If the mercury vapor generation rate could be sufficiently reduced, disposal costs for this waste would be dramatically reduced. FX Hg had previously proven effective at significantly reducing mercury vapor generation rates in bench scale testing at INL. This deployment was the first field scale deployment of the method. Efficacy results were underwhelming, but interpretation of the outcome is complicated by a paucity of hard data. Methods for improving data capture and analysis are analyzed. Operational difficulties associated with scaling the process up and process improvements for future deployments are discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Incorporating geological structure into sensitivity analysis of subsurface contaminant transport

Simulating subsurface contaminant transport at the kilometer-scale often entails modeling reactive flow and transport within and through complex geologic structures. These structures are typically meshed by hand and as a result geologic structure is usually represented by one or a few deterministically generated geological models for uncertainty studies of flow and transport in the subsurface. Uncertainty in geologic structure can have a significant impact on contaminant transport. In this study, the impact of geologic structure on contaminant tracer transport in a shale formation is investigated for a simplified generic deep geologic repository for permanent disposal of spent nuclear fuel. An open-source modeling framework is used to perform a sensitivity analysis study on transport of two tracers from a generic spent nuclear fuel repository with uncertain location of the interfaces between the stratum of the geologic structure. The automated workflow uses sampled realizations of the geological structural model in addition to uncertain flow parameters in a nested sensitivity analysis. Concentration of the tracers at observation points within, in line with, and downstream of the repository are used as the quantities of interest for determining model sensitivity to input parameters and geological realization. Finally, the results of the study indicate that the location of strata interfaces in the geological structure has a first-order impact on tracer transport in the example shale formation, and that this impact may be greater than that of the uncertain flow parameters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Test Bed for Vadose-Zone Monitoring Approaches - 20404

In the Central Plateau at the U.S. Department of Energy Hanford Site, a large inventory of contaminants resides in unsaturated sediments within the approximately 100-meter-thick vadose zone, posing a potential continuing risk to groundwater. Vadose zone remedies used to address these contaminants will require performance monitoring to provide feedback during implementation and for long-term verification that remedial action objectives have been met. Passive approaches may also need long-term monitoring to demonstrate that the flux of contaminants from the vadose zone to the groundwater are below thresholds established to meet groundwater protection goals. Collection of physical (e.g., groundwater or sediment) samples is a common method for identifying contaminant concentration distributions, but this approach is limited by the number of locations and the frequency with which data can be collected. In situ vadose zone measurements have evolved over the past few years to include key measurements of water content, soil water pressure, temperature, and chemical concentration. However, the current generation of sensors is designed for relatively short-term use in near-surface soils or sediments. Geophysical methods have been evolving but are also limited in that they have not been designed for the specific long-term vadose zone monitoring needs at the Hanford Site. Overall, monitoring under unsaturated conditions can be difficult due to the need to install and maintain instrumentation over a large area and depth and the need to identify preferential flow pathways due to geologic and chemical heterogeneities over long periods. Thus, a vadose zone monitoring test bed was initiated to address these challenges and identify cost-effective approaches for implementation and postclosure monitoring of the deep vadose zone. The monitoring test bed is expected to provide valuable field-scale information for the design of vadose zone monitoring systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical and Hydraulic Properties of RCRA Borehole Samples from the Hanford Site : Final Report, Fiscal Years 2023-2024

Sediment from 44 core samples collected from Resource Conservation and Recovery Act (RCRA) boreholes drilled in the 200 East and 200 West areas of the Hanford Site were characterized for physical and hydraulic properties (Table S.1). Characterization data included gravimetric water contents and matric potentials, grain-size distributions, saturated hydraulic conductivity, water retention characteristics, and unsaturated hydraulic conductivity. These properties provide site-specific data and parameters that can be used in subsurface flow and contaminant transport models to assess the transport and fate of contaminants in the vadose zone and underlying aquifer systems. The analyzed core samples come from specific areas and depth intervals at the Hanford Site that were targeted for sampling to address data gaps identified by site contractors (Khaleel 2020). X-ray computed tomography (XCT) was used to evaluate the general textural characteristics of the samples and to determine which samples to use for further physical and hydraulic property characterization. Subsequent sample selection was determined by consensus after review of the XCT images by Pacific Northwest National Laboratory, Central Plateau Cleanup Company, and INTERA staff.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of a Null-Space Monte Carlo Flow Model Set to the Composite Analysis Base Case Fate and Transport Modeling

The Plateau to River Groundwater Model (P2R Model) is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by CH2M HILL Plateau Remediation Company at the Hanford Site in Washington State. Figure 1-1 illustrates the P2R Model extents, discretization, and boundary conditions. The P2R Model is utilized in the Composite Analysis (CA) for the Hanford Site as the computational engine for computing F&T predictions as described in CP-60406, Hanford Site Composite Analysis Technical Approach Description: Groundwater. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. CP-57037, Model Package Report for the Plateau to River Model Version 8.3, documents the current version of the P2R Model including a description of the conceptual site model, model development and calibration, and limitations to the model application. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation is to describe the application of the hydraulic property fields and recharge parameters documented in ECF-HANFORD-20-0027, Null Space Monte Carlo Evaluation of the Plateau to River Model, to the CA flow and fate and transport simulation results to quantify the uncertainty in the simulated results due to input parameter selection. Use of numerical groundwater models is always accompanied with uncertainty in the results produced by a model because models are approximations of reality. Thus, by definition, models lack the detail to fully represent observed behavior. Use of numerical techniques, such as a NSMC analysis, can help in identifying and quantifying the potential uncertainties associated with a numerical model such as the P2R Model. The result of NSCM analysis is a set of F&T simulations that provide an estimate of the range of possible outcomes that are used to quantify the uncertainty in simulated concentrations produced using the base case simulations. The simulated concentrations from all simulations will support calculation of the uncertainty of the total dose calculated in a separate calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Functions for 200 West Pump-and-Treat SCADA Sensor Data

Historical operations at the U.S. Department of Energy’s Hanford Site included disposal of waste fluids to the subsurface in the 200 West Area on the Hanford Central Plateau. Subsequent infiltration of fluids has resulted in groundwater contamination with carbon tetrachloride, nitrate, uranium, technetium-99, and other contaminants. A pump-and-treat (P&T) system, with an extraction/injection well network and an aboveground treatment plant, was implemented as part of interim and final remedies in the 200 West area. The HYPATIA single-page web application (part of the SOCRATES suite) is being developed to provide access to and analysis of chemistry and treatment facility sensor data for this 200 West P&T system. For the web application, analytical algorithms were developed to perform summing, differencing, smoothing, outlier detection, change-point detection, mass flow rate, and injectivity calculations on the data. Candidate algorithms were identified and tested, with the best-performing algorithms then assembled for implementation in HYPATIA. Because HYPATIA is hosted on the Amazon Web Services (AWS) cloud computing platform, algorithms were implemented in a back-end AWS Lambda function that can be called by the HYPATIA front end. The Lambda function applies the requested data processing to specified data via functions written in R, Python, and JavaScript. Development, testing, and review of the data analysis algorithms was completed under an NQA-1 quality program. This new HYPATIA functionality will provide information to support site decisions regarding P&T system performance and optimization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗