Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Detection of the 158 Micrometers[CII] Transition at z=1.3: Evidence for a Galaxy-Wide Starburst

We report the detection of 158 micron [C II] fine-structure line emission from MIPS J142824.0+352619, a hyperluminous ( L(sub IR) approximates 10(exp 13) L (sub solar)) starburst galaxy at z = 1.3. The line is bright, corresponding to a fraction L(sub [Cu II] L(sub Fir) approximates 2 x 10(exp -3) of the far-IR (FIR) continuum. The [C II], CO, and FIR continuum emission may be modeled as arising from photodissociation regions (PDRs) that have a characteristic gas density of n approximates 10(exp 4.2) /cm(exp 3) , and that are illuminated by a far-UV radiation field approximately 10(exp 3.2) times more intense than the local interstellar radiation field. The mass in these PDRs accounts for approximately half of the molecular gas mass in this galaxy. The L(sub [CII])/L(sub FIR) ratio is higher than observed in local ultralummous infrared galaxies or in the few high-redshift QSOs detected in [C II], but the L(sub [CII])/L(sub FIR) and L(sub CO)/L(sub FIR) ratios are similar to the values seen in nearby starburst galaxies. This suggests that MIPS J142824.0+352619 is a scaled-up version of a starburst nucleus, with the burst extended over several kiloparsecs.

Hailey-Dunsheath, S.↗

Modeling the Fundamental Radiation Chemistry of the Organic Diluent, and the Effect of Metal Ion Complexation on the Radiochemical Behavior of Active Compounds

All used nuclear fuel (UNF) reprocessing technologies must operate efficiently in the presence of an intense, multi-component (predominantly alpha, beta, and gamma) radiation field. Consequently, radiation-induced degradation of reprocessing systems is of concern, as it negatively impacts process performance over time due to the destruction of both active compounds (ligands, phase modifiers, holdback agents, etc.) and the formation of degradation products. Reprocessing solvent system radiolysis has been linked to changes in separation efficiency and physical properties of solvent mixtures, solvent-recycle longevity, crud formation, and other unexpected outcomes that impact the efficient recovery of valuable materials (e.g., the actinides) and the volume of hazardous radioactive waste for final disposal, i.e., in a geological repository. Consequently, a fundamental understanding of radiolytic processes and their effects on reprocessing solvent system performance is critical for: (i) the cost-effective development and innovation of separation technologies; (ii) the design and implementation of predictive radiation chemical models for process monitoring and lifetimes; and (iii) potentially the ability to exploit radiolytic phenomenon to our benefit, e.g., strategic radiolysis of active molecules to liberate specific degradation products that aid subsequent process stages. Despite extensive investigation into the radiolytic behavior of active solvent system compounds, little attention has been given to understanding (i) the radiation chemical behavior and modification of the organic diluent and (ii) the effect of metal ion complexation on the radiochemical behavior of active compounds.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radiological characterization and Decommissioning of Research and Power Reactors - 15602

The production of the detailed activity and dose rate atlases (ADAs) is one of the indispensable measures in the decommissioning process of nuclear reactors which allows to determine the radiation field for optimal radiation protection as well as to quantify and characterize nuclear waste for disposal. High-detailed simulation models capable of performing neutron and radiation transport calculations at different levels of precision and details are applied for this purpose. Within the framework of the research project 'Decommissioning of Research and Power Reactors', funded by the German Federal Ministry of Education and Research (BMBF), and implemented by the Institute of Nuclear Engineering and Technology Transfer (NET) -RWTH Aachen, sophisticated simulation tools are developed. The enhances capability of these tools for the generation of the activity and dose rate distribution are tested and demonstrated on the shutdown German research reactor FRJ-2. To achieve the project goal different computational steps were required: 1. Development of a calculational CAD-based model for Monte Carlo neutron and gamma transport simulation using converter tool McCad 2. Design of the neutron source which reproduce the neutron distribution leaving the core 3. Enhancement of the simulation performance by using the hybrid deterministic Monte Carlo variance reduction methods 4. Calculation of N-flux distribution in the entire geometry 5. Development of couple codes between MCNP5 and the activation code ORIGEN2.2 This paper describes the main significant project milestones. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron dose per fluence and weighting factors for use at high energy accelerators

In June 2007, the United States Department of Energy incorporated revised values of neutron weighting factors into its occupational radiation protection Regulation 10 CFR Part 835 as part of updating its radiation dosimetry system. This has led to a reassessment of neutron radiation fields at high energy proton accelerators such as those at the Fermi National Accelerator Laboratory (Fermilab). Values of dose per fluence factors appropriate for accelerator radiation fields calculated elsewhere are collated and radiation weighting factors compared. The results of this revision to the dosimetric system are applied to americium-beryllium neutron energy spectra commonly used for instrument calibrations. A set of typical accelerator neutron energy spectra previously measured at Fermilab are reassessed in light of the new dosimetry system. The implications of this revision are found to be of moderate significance.

43 PARTICLE ACCELERATORS↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-C-BRB-01: Development of Dynamic Gimbaled X-Ray Head Swing Irradiation Technique

Purpose: The Vero4DRT has a unique gimbaled x-ray head with rotating around orthogonal two axes. The purpose of this study was to develop a new irradiation technique using the dynamic gimbaled x-ray head swing function. Methods: The Vero4DRT has maximum field size of 150Χ150 mm2. The expanded irradiation field (expanded-field) for the longitudinal direction which is vertical to the MLC sliding direction, was created by the MLC motion and the gimbaled x-ray head rotation. The gimbaled x-ray head was rotated ± 35 mm, and the expanded-field size was set as 150Χ220 mm2. To irradiate uniform dose distribution, the diamond-shaped radiation field was created and continuously moved for the longitudinal direction. It was achieved by combination of opening and closing of the MLC and gimbal swing rotation. To evaluate dosimetric characteristic of the expanded-field, films inserted in water-equivalent phantoms at 100 mm depth were irradiated and the field size, penumbra, flatness and symmetry were analyzed.In addition, the expanded-field irradiation technique was applied to virtual wedge irradiation. Wedged beam was acquired with the delta–shaped radiation field. 150Χ 220 mm2 fields with 15, 30, 45, and 60 degree wedge were examined. The wedge angles were measured with irradiated film and compared with assumed wedge angles. Results: The field size, penumbra, flatness and symmetry of the expanded-field were 150.0 mm, 8.1–8.4 mm, 2.8% and −0.8% for the lateral direction and 220.1 mm, 6.3–6.4 mm, 3.2% and −0.4% for the longitudinal direction at 100 mm depth. The measured wedge angles were 15.1, 30.2, 45.2 and 60.2 degrees. The differences between assumed and measured angles were within 0.2 degrees. Conclusion: A new technique of the gimbal swing irradiation was developed. To extend applied targets, especially for whole breast irradiation, the expanded-field and virtual wedge irradiations would be effective.

60 APPLIED LIFE SCIENCES↗

Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields

The Geant4 toolkit was used to develop a Monte Carlo (MC)-based engine for accurate dose calculations in small radiation field sizes. The Geant4 toolkit (version 10.1.p02) was used to simulate 6-MV photon beam of a Varian2100C linear accelerator that is being used for stereotactic radiosurgery (SRS) treatment with small radiation fields. Geometric models of 3 in-house designed radiosurgical divergent cones, with the diameters of their projections at the isocenter being 10, 20, and 30 mm, were simulated. The accuracy of the MC simulation technique was examined by reproducing several different simulated dosimetric parameters of the primary beams with the experimental data. The dose distributions are first checked for single beams for each cone, then standard multiple field (SMF) techniques are applied. A sample set of DICOM files from computed tomography (CT) scan imaging of a patient's head was converted to the Geant4 geometry format to implement MC-based engine for a clinical test. To validate the accuracy of the MC-based calculations for SMF arrangements, the isodose lines from MC simulation in water phantom were compared with the measured isodose lines using EBT3 Gafchromic film in Solid Water phantoms. Agreements between measured and simulated depth dose values and beam profiles for SRS cones were generally within 2%/2 mm. For output factors, the largest discrepancy was observed for 10 mm SRS cone, which was 1.7%. For SMF techniques, in SRS cones, the MC simulation and EBT3 Gafchromic film dosimetry were in acceptable agreement (5%/5 mm). Excellent agreement between the results of the MC-based and measured dose values for both single and SMF techniques in SRS cones indicates the ability of the Geant4 toolkit to be applied as the platform for treatment planning of advanced radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A decay database of coincident γ–γ and γ–X -ray branching ratios for in-field spectroscopy applications

Current fieldable spectroscopy techniques often use single detector systems heavily impacted by interferences from intense background radiation fields. These effects result in low-confidence measurements that can lead to misinterpretation of the collected spectrum. To help improve interpretation of the fission products and short-lived radionuclides produced in a composite sample, a coincidence-database is being developed in support of a robust portable and X-ray coincidence detector system concurrently under development at the Pacific Northwest National Laboratory for in-field deployment. Hitherto, no database exists containing coincident γ–γ and γ–X-ray branching-ratio intensities on an absolute scale that will greatly enhance isotopic identification for in-field applications. As part of this project, software has been developed to parse all radioactive-decay data sets from the Evaluated Nuclear Structure Data File (ENSDF) archive to enable translation into a more useful JavaScript Object Notation (JSON) formats that more readily supports query-based data manipulation. The coincident database described in this work is the first of its kind and contains coincidence γ–γ and γ–X-ray intensities and their corresponding uncertainties, together with auxiliary metadata associated with each decay data set. The new JSON format provides a convenient and portable means of data storage that can be imported into analysis frameworks with relatively low overhead allowing for meaningful comparison with measured data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microwave holographic metrology for antenna diagnosis

Advances in antenna diagnostic methodologies have been very significant in recent years. In particular, microwave holographic diagnostic techniques have been applied very successfully in improving the performance of reflector and array antennas. These techniques use the knowledge of the measured amplitude and phase of the antenna radiated fields and then take advantage of the existing Fourier transform relationships between the radiated fields and the effective aperture or current distribution to eventually determine the reflector surface or array excitation coefficients anomalies. In this paper an overview of the recent developments in applying microwave holography is presented. The theoretical, numerical and measurement aspects of this technique is detailed by providing representative results.

Rahmat-Samii, Y.↗

Winds from accretion disks - Ultraviolet line formation in cataclysmic variables

Winds from accretion disks in cataclysmic variable stars are ubiquitous. Observations by IUE reveal P Cygni-shaped profiles of high-ionization lines which are attributed to these winds. We have studied the formation of UV emission lines in cataclysmic variables by constructing kinematical models of biconical rotating outflows from disks around white dwarfs. The photoionization in the wind is calculated taking into account the radiation fields of the disk, the boundary layer, and the white dwarf. The 3D radiative transfer is solved in the Sobolev approximation. Effects on the line shapes of varying basic physical parameters of the wind are shown explicitly. We identify and map the resonant scattering regions in the wind which have strongly biconical character regardless of the assumed velocity and radiation fields. Rotation at the base of the wind introduces a radial shear which decreases the line optical depth and reduces the line core intensity. We find that it is possible to reproduce the observed P Cygni line shapes and make some predictions to be verified in high-resolution observations.

Shlosman, Isaac↗

Accelerator-Based Studies of Heavy Ion Interactions Relevant to Space Biomedicine

Evaluation of the effects of space radiation on the crews of long duration space missions must take into account the interactions of high energy atomic nuclei in spacecraft and planetary habitat shielding and in the bodies of the astronauts. These heavy ions (i.e. heavier than hydrogen), while relatively small in number compared to the total galactic cosmic ray (GCR) charged particle flux, can produce disproportionately large effects by virtue of their high local energy deposition: a single traversal by a heavy charged particle can kill or, what may be worse, severely damage a cell. Research into the pertinent physics and biology of heavy ion interactions has consequently been assigned a high priority in a recent report by a task group of the National Research Council. Fragmentation of the incident heavy ions in shielding or in the human body will modify an initially well known radiation field and thereby complicate both spacecraft shielding design and the evaluation of potential radiation hazards. Since it is impractical to empirically test the radiation transport properties of each possible shielding material and configuration, a great deal of effort is going into the development of models of charged particle fragmentation and transport. Accurate nuclear fragmentation cross sections (probabilities), either in the form of measurements with thin targets or theoretical calculations, are needed for input to the transport models, and fluence measurements (numbers of fragments produced by interactions in thick targets) are needed both to validate the models and to test specific shielding materials and designs. Fluence data are also needed to characterize the incident radiation field in accelerator radiobiology experiments. For a number of years, nuclear fragmentation measurements at GCR-like energies have been carried out at heavy ion accelerators including the LBL Bevalac, Saturne (France), the Synchrophasotron and Nuklotron (Dubna, Russia), SIS-18 (GSI, Germany), the Alternating Gradient Synchrotron at Brookhaven National Laboratory (BNL AGS) and the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan. Until fairly recently most of these experiments were done to investigate fundamental problems in nuclear physics, but with the increasing interest in heavy charged particles on the part of the space flight, radiobiology and radiotherapy communities, an increasing number of experiments are being directed at these areas. Some of these measurements are discussed in references therein. Over the past several years, our group has taken cross section and fluence data at the AGS and HIMAC for several incident beams with nuclear charge, Z, between 6 and 26 at energies between 290 and 1050 MeV/nucleon. Iron (Z = 26) has been studied most extensively, since it is the heaviest ion present in significant numbers in the GCR. Targets have included tissue-equivalent and proposed shielding materials, as well as a variety of elemental targets for cross section measurements. Most of the data were taken along the beam axis, but measurements have been made off-axis, as well. Here we present selected data and briefly discuss some implications for spacecraft and planetary habitat design.

Miller, J.↗

Evolved Late-Type Star FUV Spectra: Mass Loss and Fluorescence

This proposal was for a detailed analysis of the far ultraviolet (FUV) photoionizing radiation that provides crucial input physics for mass loss studies, e.g., observations of the flux below 10448, allow us to constrain the Ca II/Ca III balance and make significant progress beyond previous optical studies on stellar mass loss and circumstellar photochemistry. Our targets selection provided good spectral-type coverage required to help unravel the Ca II/Ca III balance as the mass-loss rates increase by over three orders of magnitude from K5 III to M5 III. We also explored the relationship between the FUV radiation field and other UV diagnostics to allow us to empirically estimate the FUV radiation field for the vast majority of stars which are too faint to be observed with FUSE, and to improve upon their uncertain mass-loss rates.

Harper, Graham M.↗

ORIGIN OF SPATIAL VARIATIONS OF SCATTERING POLARIZATION IN THE WINGS OF THE Ca I 4227 A line

Polarization that is produced by coherent scattering can be modified by magnetic fields via the Hanle effect. This has opened a window to explorations of solar magnetism in parameter domains not accessible to the Zeeman effect. According to standard theory the Hanle effect should only be operating in the Doppler core of spectral lines but not in the wings. In contrast, our observations of the scattering polarization in the Ca I 4227 A line reveal the existence of spatial variations of the scattering polarization throughout the far line wings. This raises the question whether the observed spatial variations in wing polarization have a magnetic or nonmagnetic origin. A magnetic origin may be possible if elastic collisions are able to cause sufficient frequency redistribution to make the Hanle effect effective in the wings without causing excessive collisional depolarization, as suggested by recent theories for partial frequency redistribution (PRD) with coherent scattering in magnetic fields. To model the wing polarization we bypass the problem of solving the full polarized radiative transfer equations and instead apply an extended version of the technique based on the 'last scattering approximation'. It assumes that the polarization of the emergent radiation is determined by the anisotropy of the incident radiation field at the last scattering event. We determine this anisotropy from the observed limb darkening as a function of wavelength throughout the spectral line. The empirical anisotropy profile is used together with the single-scattering redistribution matrix, which contains all the PRD, collisional, and magnetic field effects. The model further contains a continuum opacity parameter, which increasingly dilutes the polarized line photons as we move away from the line center, and a continuum polarization parameter that represents the observed polarization level far from the line. This model is highly successful in reproducing the observed Stokes Q/I polarization (linear polarization parallel to the nearest solar limb), including the location of the wing polarization maxima and the minima around the Doppler core, but it fails to reproduce the observed spatial variations of the wing polarization in terms of magnetic field effects with frequency redistribution. This null result points in the direction of a nonmagnetic origin in terms of local inhomogeneities (varying collisional depolarization, radiation-field anisotropies, and deviations from a plane-parallel atmospheric stratification)

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation study of geometric shape factor approach to estimating earth emitted flux densities from wide field-of-view radiation measurements

A study was performed on the use of geometric shape factors to estimate earth-emitted flux densities from radiation measurements with wide field-of-view flat-plate radiometers on satellites. Sets of simulated irradiance measurements were computed for unrestricted and restricted field-of-view detectors. In these simulations, the earth radiation field was modeled using data from Nimbus 2 and 3. Geometric shape factors were derived and applied to these data to estimate flux densities on global and zonal scales. For measurements at a satellite altitude of 600 km, estimates of zonal flux density were in error 1.0 to 1.2%, and global flux density errors were less than 0.2%. Estimates with unrestricted field-of-view detectors were about the same for Lambertian and non-Lambertian radiation models, but were affected by satellite altitude. The opposite was found for the restricted field-of-view detectors.

Weaver, W. L.↗

Derivation of coupled Maxwell-Schroedinger equations describing matter-laser interaction from first principles of quantum electrodynamics

We study the general problem of matter-laser interaction within the framework of nonrelativistic quantum electrodynamics, with particular emphasis on strong laser field effects. Consequently, we formulate a well-defined approximation leading in a straightforward manner toward the conventional semiclassical mode of description. Namely, we arrive naturally to two coupled equations of motion: (i) the Schroedinger equation which governs the quantum dynamics of an atomic system driven by classically described radiation field (composed of an incoming laser pulse plus radiation emitted from the atom), and (ii) the classical Maxwell wave equation which describes the emission of radiation from the mentioned atomic source. Employing the formalism of adiabatic Floquet theory, we derive a simple criterion of validity of the just described semiclassical approach. It shows that the semiclassical treatment is justified in most situations. On the other hand, it turns out that the semiclassical approximation breaks down completely in certain special but realistic cases, regardless of the fact that the incoming laser pulse contains a huge number of photons. Under such special circumstances, we anticipate new effects arising due to the quantized nature of the radiation field, to be observable, for example, in harmonic generation spectra. Our considerations are illustrated more explicitly using a simple model of a two-level atom strongly driven by a laser. The quantum dynamics of this model problem is resolved within the framework of quantum electrodynamics while adopting well-defined and physically justifiable approximations. As an outcome, analytic formulas are found serving as a quantitative criterion of (non)applicability of the semiclassical approach and demonstrating the breakdown of semiclassical theory under well-defined conditions. An illustrative numerical calculation is provided.

74 ATOMIC AND MOLECULAR PHYSICS↗

On the theory of diffraction radiation

A macroscopic theory of diffraction radiation emerging when a charged point particle moves in the vicinity of a perfectly conducting screen is developed. The integral equations derived for radiation fields form the basis for analyzing the similarity and difference of diffraction of electromagnetic radiation and diffraction radiation from a charged particle. It is shown that in the case considered here, the widely used model in which the radiation field can be represented as the field of surface current has more stringent limits of application as compared to the classical theory of diffraction. This considerably restricts the applicability of the results obtained earlier using the double-layer method to only ultrarelativistic energies and to transit angles of particles close to the direction of the normal to the screen surface. The method developed here is used for analyzing familiar problems of diffraction radiation, such as radiation emerging during normal transit of a particle along the axis of a circular aperture in the screen, radiation emitted during oblique transit near a perfectly conducting half-plane, and radiation emitted during oblique transit of a particle through a rectangular slit in an infinitely large screen. In the latter case, the results obtained after the limiting transition to zero width of the slit completely coincide with the theory of transition radiation for arbitrary energies of the particle and its angle of incidence to the screen.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A radiation quality correction factor k{sub Q} for well-type ionization chambers for the measurement of the reference air kerma rate of {sup 60}Co HDR brachytherapy sources

Purpose: The aim of this study was to investigate whether a chamber-type-specific radiation quality correction factor k{sub Q} can be determined in order to measure the reference air kerma rate of {sup 60}Co high-dose-rate (HDR) brachytherapy sources with acceptable uncertainty by means of a well-type ionization chamber calibrated for {sup 192}Ir HDR sources. Methods: The calibration coefficients of 35 well-type ionization chambers of two different chamber types for radiation fields of {sup 60}Co and {sup 192}Ir HDR brachytherapy sources were determined experimentally. A radiation quality correction factor k{sub Q} was determined as the ratio of the calibration coefficients for {sup 60}Co and {sup 192}Ir. The dependence on chamber-to-chamber variations, source-to-source variations, and source strength was investigated. Results: For the PTW Tx33004 (Nucletron source dosimetry system (SDS)) well-type chamber, the type-specific radiation quality correction factor k{sub Q} is 1.19. Note that this value is valid for chambers with the serial number, SN ≥ 315 (Nucletron SDS SN ≥ 548) onward only. For the Standard Imaging HDR 1000 Plus well-type chambers, the type-specific correction factor k{sub Q} is 1.05. Both k{sub Q} values are independent of the source strengths in the complete clinically relevant range. The relative expanded uncertainty (k = 2) of k{sub Q} is U{sub k{sub Q}} = 2.1% for both chamber types. Conclusions: The calibration coefficient of a well-type chamber for radiation fields of {sup 60}Co HDR brachytherapy sources can be calculated from a given calibration coefficient for {sup 192}Ir radiation by using a chamber-type-specific radiation quality correction factor k{sub Q}. However, the uncertainty of a {sup 60}Co calibration coefficient calculated via k{sub Q} is at least twice as large as that for a direct calibration with a {sup 60}Co source.

60 APPLIED LIFE SCIENCES↗

Integration of the ITER Tokamak C-model with the Building Model

The pellet injector system is designed to accommodate the requirement of continuous plasma refueling during ITER Tokamak operations. Through pellet flight tubes/injection lines, the pellets can directly reach the interior of the tokamak vacuum vessel. The pellet injector system is located at a port cell outside of the Tokamak bio-shield. The plasma radiation source in the tokamak vacuum vessel, together with the highly activated surrounding water in port cells, present major radiation challenges for the pellet injector system during ITER operation and after shutdown. These sources produce a radiation field encompassing the entire Tokamak complex. The ITER neutronics reference model C-model is an ITER radiation transport model. It represents a 40 deg. regular torus sector out to the bio-shield, which consists of 38 individual systems. The Monte Carlo N-Particle (MCNP) input of the C-model consists of more than a hundred thousand cell definitions and surface definitions, and over three hundred material compositions. The latest tokamak complex MCNP model is significantly more detailed than any previous releases. It consists of 36,863 cell definitions, 57,105 surface definitions, and a total of 21 different types of materials. The C-model and tokamak building model share the bio-shield as the boundary between them. In general, the radiation fields in the building due to the plasma source during tokamak operation are determined by generating the radiation source in the inner faces of the bio-shield. An inherent limitation of this approach is that it can only approximate the directions in which streaming paths are produced through the bio-shield plugs. To better estimate the shutdown dose rate for the pellet injector system due to the plasma source, we have decided to integrate the tokamak model (C-model) with the complex building model. Both MCNP models are provided by the ITER International Organization (IO) to the Oak Ridge National Laboratory (ORNL) Radiation Transport (RT) group.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗