Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Techniques for TPC Calibration: Application to Liquid Ar-TPCs

Large liquid argon TPCs are playing an increasingly important role in neutrino physics, and their calibration will be an essential component of their capability to reach the required performance and precision. Natural sources are extensively used but present limitations, since natural radioactivity from 39 Ar is of low energy, and the rate of cosmic ray muons is low when the detectors are placed deep underground. Argon gas TPCs have been calibrated with ionizing laser beams for several decades, and more recently the technique has been further developed for use in liquid TPCs. Other recent ideas include the use of external neutron generators creating pulses that propagate into the detector. This paper reviews the development of the laser and neutron methods for the calibration of argon TPCs and describes their planned implementation in the upcoming DUNE experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implanted telemeter for electrocardiogram and body temperature

Measuring system requiring one blocking oscillator to generate modulated pulse repetition rate is implantable in the bodies of small animals. Device has life of two years and transmission range of about three feet. EKG sensing unit also is used to sense electromyogram or electrooculogram of laboratory animals.

Barrows, W. F.↗

Experimental and theoretical investigation of stress wave attenuation in fiber reinforced composites.

The propagation of an initialrcidrical pressure pulse through a linear elastic fiber reinforced composite medium is analysed, both experimentally and analytically. In the experiment, tests were performed on plates with single and multiple circular inclusions embedded in a matrix of lower characteristic impedance. Sharp compression pulses were generated at an edge of the plate. Strain gages were mounted on various positions of the plate to determine the attenuation of the transient stress in the fiber reinforced composite. The qualitative analytical treatment is based on the methods of propagating stress discontinuities. Computer programs were written to numerically determine the changes in the shape of the leading wave front and the stresses immediately behind it. Experimental results for the attenuation of stress wave on steel-aluminum and steel-brass fiber-matrix composites compared very well with the computed analytical results when the applied pressure is generated by small explosive charges. The results did not compare well when the applied pressure is generated by projectile impact.

Yang, J. C. S.↗

OFO experimental techniques and preliminary conclusions - Is artificial gravity needed during prolonged weightlessness.

The technique of single unit recording from body systems generating electrical pulses coherent with their basic function (CNS, muscles, sense organs) has been proved feasible during the OFO A orbital flight, an automatic physiological experiment. The results of recording 155 hours of orbital flight of pulses from the nerve fibres of four vestibular gravity sensors in two bull frogs indicate that the vestibular organ adjusts to zero g. As all the other biological changes observed during orbit are due to lack of exercise, it is concluded that artificial gravity might not be necessary during prolonged space missions or on low gravity celestial bodies.

Gualtierotti, T.↗

Low phase-noise digital frequency divider

Digitally generated countdown pulse at submultiple frequency is applied to one electrode of FET gate to establish threshold state; gate cannot function until desired portion of reference half-wave pulse which is to be passed appears on second electrode.

Lutes, G. F., Jr.↗

Technique for extending the frequency range of digital dividers

A technique for extending the frequency range of a presettable digital divider is described. The conventional digital divider consists of several counter stages with the count of each stage compared to a preselected number. When the counts for all stages are equal to the preselected numbers, an output pulse is generated and all stages are reset. For high input frequencies, the least significant stage of the divider has to be reset in a very short time. This limits the frequency that can be handled by the conventional digital divider. This invention provides a technique in which the second least significant and higher stages are reset and the least significant stage is permitted to free-run. Hence, the time in which the reset operation can be performed is increased thereby extending the frequency range of the divider.

Long, W. C.↗

Fast scan control for deflection type mass spectrometers

A high speed scan device is reported that allows most any scanning sector mass spectrometer to measure preselected gases at a very high sampling rate. The device generates a rapidly changing staircase output which is applied to the accelerator of the spectrometer and it also generates defocusing pulses that are applied to one of the deflecting plates of the spectrometer which when shorted to ground deflects the ion beam away from the collector. A defocusing pulse occurs each time there is a change in the staircase output.

Yeager, P. R.↗

Exploratory laser experiments

Experiments are described which were undertaken to explore the application of various dye laser methods for generating laser pulses which could be tuned over H2O absorption lines in the visible and near infrared. Specific topics discussed include: operation of a long pulse dye laser with a tunable, narrow band output at high energies near the 5915 A water vapor absorption bands; assembly and operation of a short duration dye laser near the 5915 A water vapor absorption bands; construction of a dye laser to be pumped to operate in the red and near infrared; and preliminary studies of the beam divergence of the output of the a laser-pumped system. Results are summarized.

Source record↗

ULF wave generation through particle precipitation induced by VLF transmitters

The paper examines the feasibility of a technique to simulate ULF waves in the ionosphere using controlled particle precipitation. In the proposed model of micropulsation generation, a pulse from a VLF ground transmitter (or satellite transmitter) is injected into the magnetosphere and follows the earth's static magnetic field lines to a region near the magnetic equatorial plane where it begins to interact strongly with energetic electrons through gyroresonance. VLF emissions are produced in the gyroresonance interaction, and numerous energetic electrons are scattered into the loss cone, proceeding down the magnetic field lines and precipitating into the lower ionosphere where they create large-scale enhancements of ionization. The results lend support to the idea of attempting to produce detectable ULF waves by using ground- or satellite-based VLF transmitters.

Bell, T. F.↗

Measurement of bit-error rate

Error rate of RF digital communication link is measured at low signal-to-noise ratios using this technique. In this method, identical pseudo-random sequences of pulses are generated at transmitter and receiver of link. However, comparison of two sequences at receiver involves integration that makes bit-tracking threshold depend on length of pseudo-random sequence, rather than on actual rate of transmission of individual bits.

Fowler, J.↗

Computerized thermal transient test console

A system for nondestructively testing electroexplosive devices by the thermal transient test technique is described. The signal, which is generated by pulsing the electroexplosive device bridgewire is reduced to digital form. The data is then interpreted by an appropriate program and the essential electrothermal parameters are resolved. The system is fast, eliminates arbitrary interpretation of the analog, and lends itself to production testing.

Menichelli, V. J.↗

High-accuracy range measurements to the moon

The lunar ranging station at the University of Texas McDonald Observatory has made more than 1800 range measurements to the four lunar retroreflectors during the first six years of its operation. Each range consists of a normal point constructed of from 5 to 20 single photoelectron returns. Normal point accuracies to about four parts in 10 to the tenth plus or minus 10 cm have become routine. The availability of excellent commercial timing equipment means that the error for such a measurement is primarily dependent on the width of the transmitted laser pulse. Second generation systems using mode-locked subnanosecond lasers can probably achieve routine normal point accuracies approaching one part in 10 to the tenth plus or minus 2 cm. High speed pockel cells may permit such accuracies to be realized with conventional Q-switched lasers.

Silverberg, E. C.↗