Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Program Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

West Village Community: Quality Management Processes and Preliminary Heat Pump Water Heater Performance

West Village, a multi-use project underway at the University of California Davis, represents a ground-breaking sustainable community incorporating energy efficiency measures and on-site renewable generation to achieve community-level Zero Net Energy (ZNE) goals. When complete, the project will provide housing for students, faculty, and staff with a vision to minimize the community’s impact on energy use by reducing building energy use, providing on-site generation, and encouraging alternative forms of transportation. This focus of this research is on the 192 student apartments that were completed in 2011 under Phase I of the West Village multi-year project. The numerous aggressive energy efficiency measures implemented result in estimated source energy savings of 37% over the B10 Benchmark. There are two primary objectives of this research. The first is to evaluate performance and efficiency of the central heat pump water heaters as a strategy to provide efficient electric water heating for net-zero all-electric buildings and where natural gas is not available on site. In addition, effectiveness of the quality assurance and quality control processes implemented to ensure proper system commissioning and to meet program participation requirements is evaluated. Recommendations for improvements that could improve successful implementation for large-scale, high performance communities are identified.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuisance Odors: Is there a Concern - 12340

Nuisance odors are generally thought of as just being annoying or unpleasant and not causing any physiological harm to our internal organs or other biologic systems. Yet during an excavation of buried animal remains, field workers experienced a multitude of symptoms that are associated with exposures to toxic materials. An examination of the decomposition process revealed that there is a potential off-gassing of a number of common, yet harmful chemicals including ammonia, mercaptans, hydrogen sulfide, butyric acid and phenol. In addition, other compounds, that have limited information such as established health data and occupational exposure limits, were also potential contaminants-of-concern. While a variety of monitoring and sampling techniques were used to assess worker exposures, all results indicated non-detectable airborne concentrations. Nevertheless, workers were experiencing such symptoms as nausea and headaches. As such, protective measures were necessary for field personnel to continue work while having confidence that the project was instituting sincere steps to ensure their health and safety. Researching the possible reasons for the causes of workers exhibiting adverse health effects from nuisance odors revealed that such exposures initiate electrochemical pathways, starting from the olfactory bulb to the brain, followed by a transfer of information to such biologic systems as the hypothalamus and pituitary gland. These systems, in turn, secrete hormones that cause a number of involuntary reactions; many of which are observed as typical adverse health effects, when in fact, they are merely reactions caused by the brain's memory; most likely created from previous experiences to unpleasant odors. The concern then focuses of how the Occupational Safety and Health community shall respond to such workplace exposures. Future work in this area may need to focus on the viability of current occupational exposure limits and the possibility of revising these standards. Another area of consideration would be whether nuisance odors will need separate and distinct criteria with regards to hazard identification and control. While evidence suggests that odorants do not cause direct toxicological effects to the various biologic systems, they can be influential by initiating symptoms that are associated with known toxins. The difference between the classic toxic systemic reactions and those initiated by nuisance odors can be summarized as one causing a dysfunction of a target organ or system as opposed to triggering a message to the brain which causes a physical reaction. While strong odors may exist at HAZWOPER work sites, their particular risk of pathogenic disease has yet to be established. This leaves many unanswered questions; the most obvious being, 'can an odorous chemical that can result in headaches, nausea, changes in blood pressure, body temperature, etc., be considered a toxin even if biological systems remain unaffected and sampling/monitoring protocol negative stimuli, thereby causing symptomatic experiences; will such disciplines as psychology need to be considered as part of the expertise within the field a environmental and occupational health? In the classic text, 'The Fundamentals of Industrial Hygiene' industrial hygiene has been defined as 'that science and art devoted to the anticipation, recognition, evaluation, and control of those environmental factors or stressors arising in or from the workplace that may cause sickness, impaired health and well-being, or significant discomfort among workers or among the citizens of the community'. Based on this definition, it is indeed the responsibility of the occupational health professional to move forward and to provide an effective program to 'anticipate, recognize, evaluate, and control' such airborne contaminants that may not be adequately controlled based on current knowledge and technology. The question is, 'Is the industrial hygiene community equipped to carry out this responsibility?' 'Are new assessment methods and tools necessary? Are alternate exposure limits needed and can they be adequately implemented? As more of the non-traditional health hazards become recognized, it appears that it shall be essential for more sophisticated methods to be part of the standard practice used to assess human health. Whether that means more sensitive equipment that has greater detection capabilities, or the development of new technologies designed specifically for these hazards, at present can only be left to speculation. While the occupational health community may wrestle with these questions, the responsibility of the safety and health community must maintain its diligence. As such, persons within the discipline of environmental and occupational health must continue to communicate the hazards and controls to the work force. Through such efforts, the workforce shall become engaged in the process of hazard identification, assessment and control, which, in turn, will create a greater appreciation and acceptance for field assessment methods as well as the processes by which workplace controls are designed to protect them. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Historical Data Analysis Supporting the Data Quality Objectives for the INL Site Environmental Soil Monitoring Program

This document represents the initial evaluation and soil monitoring proposed by Battelle Energy Alliance, LLC (BEA) in 2015. The evaluation included analyses of historical soil monitoring data and soil inventories, current emission estimates, and modeled potential deposition/accumulation patterns. The initially proposed monitoring included a 5-year rotation of in-situ gamma measurements augmented by soil sampling with laboratory analyses near each major active and some inactive facilities. It also proposed rotational in-situ gamma measurements and soil sampling at two centrally located onsite air monitoring locations coinciding with sampling at the traditional offsite soil monitoring locations. The chosen alternative includes only physical soil sampling with laboratory analysis and only at the Radioactive Waste Management Complex (RWMC), the two air monitors and the offsite locations as documented in Data Quality Objectives Supporting the Environmental Soil Monitoring Program for the Idaho National Laboratory (INL) Site, INL/EXT-15-34909, Revision 0, February 2016. The data and evaluations in this document are valid for comparisons with future soil data that may be collected in many INL site locations.

54 ENVIRONMENTAL SCIENCES↗

Evaluating the Impact of E15 on Snowmobile Engine Durability and Vehicle Driveability: September 22, 2010 - August 15, 2013

The objective of this study was to evaluate the effects of E15 on current and legacy snowmobile engines and vehicles that could occur due to misfueling by the vehicle owner. Three test scenarios were conducted to evaluate the impact of E15, including cold-start performance and emissions, on-snow vehicle driveability, and laboratory exhaust emissions over the useful life of the engine. The eightengines tested represent current and legacy product that may exhibit sensitivity to increased ethanol blended in gasoline. Because a limited number of snowmobile engines were evaluated for this test program, the results are not statistically significant. However, the broad range of engine and mixture preparation technologies, combined with the various test scenarios provide preliminaryinformation to assess potential issues with E15 use in snowmobiles. Cold-start tests were performed at -6.7 degrees C (20 degrees F), -17.8 degrees C (0 degrees F), and -28.9 degrees C (-20 degrees F). The evaluation included time to start or number of pulls to start, engine speed, exhaust gas temperature, and start-up engine emissions concentrations. Statistically significant differences instarting times were not observed for most vehicles. Snowmobile driveability was analyzed using a subjective evaluation on a controlled test course. The drivers could not easily discern which fuel the snowmobiles were using during the subjective evaluation. Durability tests were conducted to measure the emissions and performance of the snowmobiles over the useful life of the vehicles (5,000miles). There were no fuel-related engine failures on E0 or E15. Carbon monoxide emissions were generally reduced by E15 relative to E0, by from 10% to 35%. Occasional misfueling of snowmobiles with E15 is not likely to cause noticeable or immediate problems for consumers. E15 is not approved for snowmobile use, and observations made during this study support the U.S. Environmental ProtectionAgency's decision to not approve E15 for snowmobiles.

33 ADVANCED PROPULSION SYSTEMS↗

Solid-State Lighting: Early Lessons Learned on the Way to Market

The purpose of this report is to document early challenges and lessons learned in the solid-state lighting (SSL) market development as part of the DOE’s SSL Program efforts to continually evaluate market progress in this area. This report summarizes early actions taken by DOE and others to avoid potential problems anticipated based on lessons learned from the market introduction of compact fluorescent lamps and identifies issues, challenges, and new lessons that have been learned in the early stages of the SSL market introduction. This study identifies and characterizes12 key lessons that have been distilled from DOE SSL program results.

CFLs↗

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level—split-core current transformers (CTs) and power monitoring meters—have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces (API). NREL evaluated Meazon’s single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Developing a Human Factors Engineering Program Plan and End State Vision to Support Full Nuclear Power Plant Modernization

The Light Water Reactor Sustainability (LWRS) Program, which is sponsored by the United States (U.S.) Department of Energy (DOE), conducts research and development (R&D) to establish the technical bases to sustain U.S. nuclear assets. One area in the LWRS program is the Plant Modernization pathway, which includes human factors R&D, human factors engineering (HFE), and ergonomics. LWRS program researchers in this pathway conduct targeted R&D to address aging and reliability concerns with the legacy instrumentation and control (I&C) and related information systems in commercial nuclear power plants (NPPs). One key aspect of this pathway is to develop a strategy for full nuclear plant modernization, which previous LWRS plant modernization milestone reports have begun to describe. To further support this comprehensive plan and vision for full plant modernization, additional details need to be further developed. In particular, a core aspect of a strategy for full nuclear plant modernization is an HFE program plan and an end state vision for plant modernization that is well-integrated with both 1) a technically defensible approach to migrating the existing, mostly analog I&C infrastructure to a digital I&C infrastructure, and 2) a valid business case methodology to cost-justify the modernization activity. Thus, the purpose of this LWRS R&D activity and milestone report is threefold. First, the report provides guidance for operating commercial NPPs to support their development and evaluation of an HFE program management plan (HFE PMP) and an end state vision for plant modernization. The report presents best practices and lessons learned related to HFE PMPs based on MCR modifications in which analog systems were replaced by digital I&C systems. Second, the report summarizes the rationale for full digital I&C integration, highlights a number of factors that are critical to consider, and describes how HFE should merge with full digital I&C integration. Finally, the report summarizes and integrates the economic factors that must be considered to cost-justify HFE involvement in plant modernization.

99 GENERAL AND MISCELLANEOUS↗

Failure mode and effects analysis based risk profile assessment for stereotactic radiosurgery programs at three cancer centers in Brazil

Purpose: The goal of this study was to evaluate the safety and quality management program for stereotactic radiosurgery (SRS) treatment processes at three radiotherapy centers in Brazil by using three industrial engineering tools (1) process mapping, (2) failure modes and effects analysis (FMEA), and (3) fault tree analysis. Methods: The recommendations of Task Group 100 of American Association of Physicists in Medicine were followed to apply the three tools described above to create a process tree for SRS procedure for each radiotherapy center and then FMEA was performed. Failure modes were identified for all process steps and values of risk priority number (RPN) were calculated from O, S, and D (RPN = O × S × D) values assigned by a professional team responsible for patient care. Results: The subprocess treatment planning was presented with the highest number of failure modes for all centers. The total number of failure modes were 135, 104, and 131 for centers I, II, and III, respectively. The highest RPN value for each center is as follows: center I (204), center II (372), and center III (370). Failure modes with RPN ≥ 100: center I (22), center II (115), and center III (110). Failure modes characterized by S ≥ 7, represented 68% of the failure modes for center III, 62% for center II, and 45% for center I. Failure modes with RPNs values ≥100 and S ≥ 7, D ≥ 5, and O ≥ 5 were considered as high priority in this study. Conclusions: The results of the present study show that the safety risk profiles for the same stereotactic radiotherapy process are different at three radiotherapy centers in Brazil. Although this is the same treatment process, this present study showed that the risk priority is different and it will lead to implementation of different safety interventions among the centers. Therefore, the current practice of applying universal device-centric QA is not adequate to address all possible failures in clinical processes at different radiotherapy centers. Integrated approaches to device-centric and process specific quality management program specific to each radiotherapy center are the key to a safe quality management program.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technology Validation: Fuel Cell Bus Evaluations

Presented at the U.S. Department of Energy Hydrogen and Fuel Cells Program 2015 Annual Merit Review and Peer Evaluation Meeting, June 8-12, 2015, in Arlington, Virginia.

30 DIRECT ENERGY CONVERSION↗

Removal of deuterium retained in boron powder by oxygen or high-temperature bakeout

Fuel retention in dust accumulated in fusion devices is a potential operational hazard. Boronization is one of the leading wall-conditioning candidates for future fusion devices. Fuel retention characteristics of boron dust must be studied to accurately understand the potential hazards of boron dust in fusion devices. We evaluated the retention of deuterium (D) in commercially available boron powder as a proxy for tritium retention in boron dust. Diffuse reflectance infrared Fourier transform spectroscopy revealed that boron powder between 300 and 500 K exposed to neutral hydrogen (H 2 ) gas retains H via B-H bonding. We utilized D 2 exposures of 17,400 L on the boron powder, which led to retention on the order of 0.5 g D per 100 kg B or 1.2 g D per m 2 B, as estimated from temperature programmed desorption measurements. We evaluated how powder bakeouts under ultra-high vacuum (UHV), or in an oxygen (O 2 ) or H 2 gas backfilled environment can remove the retained fuel. Bakeouts below 523 K under UHV exhibited poor D removal, promoting recapture of D 2 present as background gas in the chamber. Higher temperature bakeouts led to the removal of over 80% of the retained D within 3 days (623 K) or 1 h (723 K). Bakeouts at 423 K under an O 2 gas environment removed ∼150% more retained D from the boron powder, when compared to bakeouts conducted under UHV. These results suggest that efficient fuel removal from boron dust can be achieved by high-temperature bakeout (>623 K) or by bakeouts at lower temperature (423 K) under an O 2 environment.

Bakeout↗

ATRIUM{sup TM} 11 operating experience

AREVA NP developed the ATRIUM{sup TM}11 BWR fuel assembly to address the industry need for substantial improvements in fuel reliability and economic performance. The product development effort initially consisted of analytical design assessments and out-of-pile testing of prototype fuel assemblies and components. An integral component of the development project is a comprehensive in-pile demonstration program designed to fully exercise the new fuel assembly under a variety of operating conditions and to provide performance measurements of new design features. Fuel vendors, reactor operators, and regulators have successfully relied upon irradiation feedback derived from in-pile demonstration programs to safely introduce new features in reload quantities. The primary ATRIUM{sup TM} 11 in-pile demonstration program consists of 40 lead fuel assemblies (LFA) operating among five BWR reactors globally, covering the range of operational regimes and licensing environments necessary to confirm reload applications for the product. Since the initial irradiation in 2012, multiple pool-side inspection examinations have been performed. The inspection activities primarily focused on the new design features; including the spacer, fuel rod array, upper tie plate and fuel channel. These inspections have resulted in the collection of a substantial set of visual images, dimensional measurements, and performance feedback that are of general interest to the industry. Results from the inspections are compared to the database for existing products and to predetermined acceptance criteria. This paper provides details of the global in-pile demonstration program and the characteristics of the LFAs. Results of the inspection campaigns will be presented, including a summary of the technical assessment of specific new design features and the overall performance of the ATRIUM{sup TM} 11 product. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Synthesis of Findings from an Integrated Hatchery Program after Three Generations of Spawning in the Natural Environment

Abstract The Cle Elum Supplementation and Research Facility in the Yakima River basin, Washington, is an integrated spring Chinook Salmon Oncorhynchus tshawytscha hatchery program designed to test whether artificial propagation can increase natural production and harvest opportunities while keeping ecological and genetic impacts within acceptable limits. Only natural-origin (naturally spawned) fish are used for hatchery broodstock. Spawning, incubation, and early rearing occur at a central facility; presmolts are transferred for final rearing, acclimation, and volitional release at sites adjacent to natural spawning areas, where returning adults can spawn with natural-origin fish. The first wild broodstock were collected in 1997, and age-4 adults have returned to the Yakima River since 2001. An unsupplemented population in the adjacent Naches River watershed provides a reference for evaluating environmental influences. The program has been comprehensively monitored from its inception. A synthesis of findings, many already published, is as follows: supplementation increased the harvest, redd counts, and spatial distribution of spawners; natural-origin returns were maintained; straying to nontarget systems was negligible; natural-origin females had slightly higher breeding success (production of surviving fry) in an artificial spawning channel, while the behavior and breeding success of natural- and hatchery-origin males were similar; hatchery-origin fish showed differences in morphometric and life history traits; high rates of hatchery age-2 (minijack) production were reported, but the observed proportions of out-migrating juvenile and adult (ages 4 and 5) returning males were comparable for hatchery- and natural-origin fish; hatchery smolts did not affect the levels of pathogens in natural smolts; and the ecological interactions attributed to the program were within adopted guidelines. Continued study is required to assess the long-term impacts on natural production and productivity.

Fast, David E.↗

Achieving Cooperative Community Equitable Solar Sources (ACCESS) (Final Technical Report)

Since 2011, solar has grown from a niche technology to a widely accessible source of power for homes and businesses across the United States and has become a fundamental part of the modern grid. There are still challenges, however, in learning how to integrate and use PV most effectively and how to make PV universally available. Most low- and moderate-income (LMI) customers cannot currently afford PV; capital costs and financing costs are too high to drive significant penetration. Providing access to LMI individuals and communities is a critical and immediate priority, and the focus of this project. The overall objective of the Achieving Cooperative Community Equitable Solar Sources (ACCESS) project is to explore and amplify the use of innovative, cost-effective energy access programs to serve co-ops’ LMI members1. ACCESS will research at least three financing mechanisms and at least six LMI program designs including LMI engagement strategies to maximize participation for these hard-to-reach audiences. ACCESS evaluated the financial mechanisms and program designs from field tests sited at diverse co-ops that provide recognizable models for the broader co-op community to identify optimal solutions for small utilities. The research with these cooperatives allowed testing of concepts and development of models and tools for other utilities to adapt to their own program designs and expansions. ACCESS published results and developed an “ACCESS Solar Access Toolkit” consisting of program designs, LMI engagement strategies, how-to guidance, and other tools to facilitate replication at small utilities across the country. Through the dissemination practices of the ACCESS project team, all NRECA member co-ops (~900) were made aware of the “ACCESS Solar Access Toolkit” and all other ACCESS resources. NRECA and its partners developed innovations to expand co-ops’ solar energy offerings to provide all of a co-op’s members—especially those who struggle to pay their bills—with cost-effective options that meet their needs. ACCESS specifically explored utility financing mechanisms and program designs that, independently or used in combination, increase solar access for rural electric cooperatives’ LMI members/ratepayers and that reduce LMI member/ratepayers’ electricity costs by at least 10%. LMI engagement strategies focused on maximizing the number of members who receive benefits and on the cost savings to LMI participants.

14 SOLAR ENERGY↗

CEERP SM3 Research, Monitoring, and Evaluation Workshop: Summary Report

The Columbia Estuary Ecosystem Restoration Program (CEERP) workshop, “CEERP Synthesis Memorandum (SM3): Research, Monitoring, and Evaluation,” was held in Portland, Oregon on June 24–25 2024. A diverse group of 26 domain experts with demonstrated knowledge and experience working in the Lower Columbia River Estuary (LCRE) participated. The workshop supported development of the forthcoming third Synthesis Memorandum for CEERP. The workshop furthered the collaborative understanding of the state of the science regarding the LCRE, helped to identify remaining knowledge gaps and uncertainties, and assisted in the prioritization of future restoration research and monitoring.

54 ENVIRONMENTAL SCIENCES↗

Inter-digital capacitive sensor for evaluating cable jacket and insulation aging

An inter-digital capacitive (TDC) sensor has previously been used to measure dielectric properties of cable insulation polymer material when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket. The dielectric properties of many cable jacket and insulation polymers are known to change due to thermal and radiation exposure-related damage. These dielectric properties frequently track with other measures of cable aging, such as tensile elongation-at-break and indenter modulus that have been broadly established as cable insulation polymer assessment methods. The external jacket of a cable is likely to have a different permittivity from the underlying insulation, and frequently the jacket material exhibits more severe damage than the insulation material due to environmental exposure. Because the jacket serves primarily to guard the cable during installation, as long as the underlying insulation condition is acceptable, the jacket condition is relatively unimportant in service. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, a set of tools has been developed including (1) a parallel-plate sensor to directly measure the permittivity spectrum of flat sheet material and (2) an TDC and fixture to measure the effect of cable polymer dielectric property change on the sensor response. The TDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. The electrodes are printed on one side of a flexible substrate that can be conformed to the surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad-frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. By finite element modeling (FEM) and experimentation, this study investigates the effect of tine spacing and other design parameters associated with the TDC on the voltage (potential) distribution and electric field depth of penetration. The TDC measurement of an unshielded ethylene-propylene rubber (EPR)-insulated cable is shown to track with the degree of aging and quantities obtained by established methods. For jacketed cable systems, the TDC response is dominated by the jacket but, by analyzing measurements from TDC sensors with different depths-of-field penetration into the cable under test, the influence of the chlorinated polyethylene (CPE) cable jacket material degradation can be separated from an assessment of the cable insulation thereby enabling assessment of the insulation beneath/through the jacket.

Cable NDE, Interdigital Capacitance, Cable test↗

Evaluation of the Radiological Characterization for Off-Site Source Recovery Program Waste Streams LA-OS-00-01.001, LA-OS-00-03, and LA-OS-00-04

The purpose of this memorandum is to satisfy the requirements of Section 4.4 of the CCP Acceptable Knowledge Documentation procedure CCP-TP-005 (Ref. 1). This evaluation is updating the previously issued memo NEN3:24-045 issued in August 2024. CCP-TP-005 requires an AK Expert and the OSRP group to evaluate the radionuclide characterization of a waste stream and prepare the NDA Memorandum (letter to CCP Records). This NDA memorandum was written with input from the OSRP group, as required by CCP-TP-005. This memo includes a discussion of the limitations for the radiological characterization and a description of the characterization method.

07 ISOTOPE AND RADIATION SOURCES↗

DOE/DOT Crude Oil Characterization Research Study, Task 2 Test Report on Evaluating Crude Oil Sampling and Analysis Methods, Revision 1 - Winter Sampling

The Crude Oil Characterization Research Study is designed to evaluate whether crude oils currently transported in North America, including those produced from “tight” formations, exhibit physical or chemical properties that are distinct from conventional crudes, and how these properties associate with combustion hazards that may be realized during transportation and handling. The current report presents results from Task 2, investigating which commercially available methods can accurately and reproducibly collect and analyze crude oils for vapor pressure and composition, including dissolved gases. This issue, Revision 1 – Winter Sampling, incorporates additional seasonal data and compositional analysis results that have become available since publication of a prior report, SAND2017-12482, released in December 2017. Both reports compare performance of commercially available methods to that of a well-established mobile laboratory system that currently serves as the baseline instrument system for the U.S. Strategic Petroleum Reserve Crude Oil Vapor Pressure Program. The experimental matrix evaluates the performance of selected methods for (i) capturing, transporting, and delivering hydrocarbon fluid samples from the field to the analysis laboratory, coupled with (ii) analyzing for properties related to composition and volatility of the oil, including vapor pressure, gas-oil ratio, and dissolved gases and light hydrocarbons. Several combinations of sample capture and analysis were observed to perform well in both summer and winter sampling environments, though conditions apply that need to be considered carefully for given applications. Methods that perform well from Task 2 will then be utilized in subsequent Task 3 (combustion studies) and Task 4 (compositional analyses of multiple crude types), to be addressed in subsequent reports.

02 PETROLEUM↗

Technoeconomic Evaluation of MEA versus Mixed Amines for CO 2 Removal at Near-Commercial Scale at Duke Energy Gibson 3 Plant

Carbon emissions in the power sector remains an important goal for both US and Chinese decision makers and industrial leaders. In order to deeply reduce their greenhouse gas emissions, many utilities are considering carbon capture, utilization, and sequestration (CCUS). For the existing US and Chinese coal-burning fleets, post-combustion capture (PCC) is the only viable approach. While companies provide technology for PCC retrofits, typically solvent-based absorption systems involving amine solutions, the costs and performance of these systems remain largely untested in commercial settings. As such power generation companies have very few technical or economic data sets on which to base large capital decisions. In support of gaining this information, the world’s largest power company, Huaneng Power Group, has developed and deployed several PCC systems as retrofits to Chinese coal-fired power plants. Duke Energy Inc., North America’s largest power generator, is considering options for CCUS retrofits and has created a partnership with Huaneng to assess the viability of a retrofit project on one of its US plants. In support of this effort, and in partnership with Duke and Huaneng under the US-China Clean Energy Research Program (CERC), LLNL has evaluated the economics of a novel amine-solvent technology for removal of CO 2 from flue gas developed by Huaneng’s Clean Energy Research Institute (Huaneng CERI). This technology is being considered for implementation by Duke Energy at their Gibson-3 unit in Indiana.

01 COAL, LIGNITE, AND PEAT↗